Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | PART - I : CIVIL & STRUCTURAL WORKS |
| 2 | Demolition of Brick/Stone masonry |
| 3 | Site clearance by demolition of Brick/stone masonry/ in walls, stone soling, RCC, PCC, pavior blocks in flexible/rigid pavements etc., removing the debris or any type of material and disposal of serviceable or unserviceable material to any lead as per technical specifications and directions of the Engineer-in-charge. |
| 4 | Dismantling of Bolted/ welded structural steel fencing |
| 5 | Dismantling of existing bolted /welded steel fencing erected on 1.50 m high brick wall complete in all respect and disposal of serviceable or unserviceable material to any lead as per technical specifications, tender documentand direction of Engineer-in-charge |
| 6 | Temporary Barricading: Providing and fixing temporary barricading using GI sheets and ISA 50x50x6 mm, grouting of angle etc. complete in all respect as pertechnical specifications, tender documentand direction of Engineer-in-charge |
| 7 | Surface Dressing |
| 8 | Surface Dressing of ground including removing vegetaltion tress of girth upto 40 cm removing all inequalities not exceeding 15 cm deep and disposal fo rubbish to any lead as pertechnical specifications, tender documentand direction of Engineer-in-charge |
| 9 | Earth work in excavation/site grading |
| 10 | Earth work in excavation in all kinds of soil except rock in any plan dimension up to 3.0 M depth including disposal of excavated earth up to any lead in all conditions, and disposal of surplus and unserviceable earth. Soil to be leveled and neatly dressed complete in all respect as per scope of work, detailed construction drawings, as per technical specifications and directions of the Engineer-in-charge. |
| 11 | Earth work in excavation same as above but beyond 3.0m and upto 6.0m |
| 12 | Earth work in hard rock: |
| 13 | Excavation in hard rock including PCC, RCC, pavior blocks in flexible/rigid pavements etc., removing the debris or any type of material and disposal of serviceable or unserviceable material to any lead as per technical specifications and direction of EIC |
| 14 | (The Contractor shall take into account in his rate, the provision for excess excavation for necessary working space, slope etc., required for excavation and other allied works and refilling the side slopes and working space) |
| 15 | Earthwork in filling: |
| 16 | Earth work in filling with good quality imported earth from approved source in the layers of 150 mm and compacted up to 95% to its MDD up to 4 m depth and any plan dimension including all testing, watering, rolling each layer with 1/2 tonne roller or wooden or steel rammers, and every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing / filling up ground depressions etc. complete in all respect as per scope of work, detailed construction drawings, as per technical specifications and directions of the EIC. |
| 17 | Supplying and filling Sand in 150 mm thicklayers watering, rolling, ramming, consolidating and dressing the surface including cost of sand (zone-II/Zone-III sand only) complete in all respect as per scope of work, detailed construction drawings as per technical specifications and directions of the Engineer-in-charge. |
| 18 | Stone Soling / Rubble massonry |
| 19 | Providing and laying stone ballast 115 to 150 mm size in layers of 300 mm thickor 1: 4 rubbly massonry with spreading & blinding material like sand, stone grit and compaction with mechanical means, watering etc. including cost of material complete in all respect as per scope of work, detailed construction drawings as per technical specifications and directions of the Engineer-in-charge. |
| 20 | Brick Work in foundation with CM 1:4 |
| 21 | Providing, construction and handing over of brick masonry foundations below DPC including weepholes, plastering of 15 mm thickness in CM 1:4 on exposed surfaces, mudmat, excavation and backfilling with serviceable earth, complete in all respects as per scope of work, detailed construction drawings, technical specifications and direction of Engineer-in-charge. |
| 22 | Brick Work in superstructure with CM 1:4 |
| 23 | Providing, construction and handing over of brick walls of superstructure plastering of 15 mm thickness in CM 1:4 on both the faces complete in all respects as per scope of work, detailed construction drawings, technical specifications and direction of Engineer-in-charge. |
| 24 | PCC |
| 25 | Providing, laying in position, construction and handing over of PCC in foundations, substructure, superstructure and under floor, etc complete in all respects as per scope of work, detailed construction drawings, technical specifications and direction of Engineer-in-charge. |
| 26 | a) PCC 1:2:4[1 Cement: 2 coarse sand : 4 stone aggregate 20 mm nominal size] |
| 27 | b) PCC 1:3:6[1 Cement: 3 coarse sand : 6 stone aggregate 20 mm nominal size] |
| 28 | c) PCC 1:4:8[1 Cement: 4 coarse sand : 8 stone aggregate 40 mm nominal size] |
| 29 | RCC in foundation |
| 30 | M-20 gr (1:1.5:3) |
| 31 | Providing, laying in position, construction and handing over of RCC 1:1.5 :3 in foundations, substructure and under floor including shuttering inserts/ anchor bolts, sleeves, two coats of bitumen paint on surfaces in contact with soil etc complete in all respects as per scope of work, detailed construction drawings, technical specifications and direction of EIC. |
| 32 | RCC in foundation |
| 33 | M-25 gr (1:1:2) |
| 34 | Providing, laying in position, construction and handing over of RCC 1:1 :2 in foundations, substructure and under floor including shuttering inserts/ anchor bolts, sleeves, two coats of bitumen paint on surfaces in contact with soil etc complete in all respects as per scope of work, detailed construction drawings, technical specifications and direction of EIC |
| 35 | RCC in superstructure |
| 36 | Providing, construction and handing over of RCC M25 GR in superstructure elements such as walls, retaining walls, columns, beams etc. includingshuttering inserts, conduits, openings, accesses, edge protection etc. complete in all respects as per scope of work, detailed construction drawings, technical specifications and direction of Engineer-in-charge. |
| 37 | [1. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as minimum 43 grade cement, coarse sand and coarse aggregates, other minor construction materials, shuttering, staging, shoring/strutting, finishing, testing etc.all bye works and sundry works.] |
| 38 | Reinforcement steel |
| 39 | Supplying and Fabricating and Fixing in position HYSD Steel Reinforcements/ TMT Grade Fe-500 D conforming toIS1786-1985 at all levels and positions including the Cost of transport, Straightening, Cutting, Bending, Cranking, Binding, Welding, Provision of necessary Chairs and Spacers, Preparation of bar bending schedule Drawings, getting the same approved etc., as per Drawings and Specifications and including Cost of binding wire, Labour etc., all complete in all respects as per scope of work, detailed construction drawings, technical specifications and direction of Engineer-in-charge. The chairs and spacer bars provided will not be Measured for payment. |
| 40 | Compound wall |
| 41 | Providing, constructing and finishing of compound wall in brick masonry/ RCC Wall 250 thk with RCC 460 square pillar at interval of 3 mt or as specified in construction drawings, and height 3 mt m as per scope of workdetail construction drawings, including plastering, coping, painting, GI Pipe,whitewash, finishes all complete as per technical specifications and direction of the Engineer-In-Charge. |
| 42 | BUILDING WORKS |
| 43 | RCC framed structure building [Refer PREAMBLE BUILDING WORKS RCC FRAMED STRUCTURE BUILDING]. |
| 44 | Providing, construction and handing over of RCC framed structure building, including reinforcing steel, finishes, fittings, fixtures, complete in all respects as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-in-charge. |
| 45 | SOAK PIT AND SEPTIC TANK |
| 46 | Providing and construction of septic tank and soak pit in brick masonry and base and top slab in RCC M20 complete in all respect as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-in-charge. |
| 47 | [1.Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as minimum 43 grade cement including chemical resistant paint for sub-structures, bricks, inserts, bolts, covers, aggregates/ sand fill conduits, finishes, bitumen, other minor construction materials, shuttering , staging, earthwork in excavation and backfilling using serviceable/ borrow earth in all conditions, shoring/strutting, bailing and pumping out water, masonry work, plastering, plumbing, sanitation, etc. with all bye works and sundry works.] |
| 48 | UNDER GROUND WATER TANK |
| 49 | Providing and construction of underground water tank in RCC/BM and base and top slab in RCC M-30 complete in all respect as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-in-charge. |
| 50 | [1.Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as minimum 43 grade cement including chemical resistant paint for sub-structures, bricks, inserts, bolts, covers, aggregates/ sand fill conduits, finishes, bitumen, other minor construction materials, shuttering, staging, earthwork in excavation and backfilling using serviceable/ borrow earth in all conditions, shoring/strutting, bailing and pumping out water, masonry work, plastering, plumbing, sanitation, etc. with all bye works and sundry works.] |
| 51 | RCCFLOORING IN FORECOURT |
| 52 | Providing construction and handing over of 150 mm thick RCC 1:1:2 (Nominal mix strength not less than 25 N/mm2 conforming to IS) forecourt over 100 mm thick PCC (1:3:6) & 150 mm thick Brick bat soling ( 63mm to 90mm) including reinforcement steel complete in all respects as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-in-charge. |
| 53 | CNG Area FLOORING |
| 54 | DWAY .WBM 150 mm THIK |
| 55 | PAVER BLOCK FLOORING IN FORECOURT |
| 56 | Supply, construction and handing over of CC inter locking paver block 80 mm thick, I shape, rough finish, M-40 strength with epoxy coating of approved brand laid over the sand bed of minimum 75 mm thick. The CC interlocking blocks to be of uniform Grey colour or as approved by EIC complete in all respects as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-in-charge. |
| 57 | Single SS Tube Trench in Forecourt |
| 58 | Providing and construction ofSingle SS tube trench in RCC/ CQ Plate Cover over the 100 mm thick PCC (1:4:8)base with precast SFRC cover of 600x550X 70 mm thk alongwith edge angle (ISA 75x75x6) and fixing of ISA 50x50x6 for supporting pipetrays @ spacing of 1000 mm c/c along the trench, including 12 mm in CM 1:5 plastering of walls of trenches complete in all respect as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-in-charge. |
| 59 | Double SS Tube Trench in Forecourt |
| 60 | Same as above for Double SS tube trench. |
| 61 | External sewerage and Water Piping |
| 62 | Supply, laying and commissioningRCC pipes of 300 dia including earth cutting, filling, disposal of surplus earth, bed concrete, RCC pipe, SW gully trap/ chamber, grease trap, all complete in all respects as per scope of work, detailed drawings, technical specification and directions of the EIC. |
| 63 | Supply, laying and commissioningRCC pipes of 150 dia including earth cutting, filling, disposal of surplus earth, bed concrete, RCC pipe, SW gully trap/ chamber, grease trap, all complete in all respects as per scope of work, detailed drawings, technical specification and directions of the EIC. |
| 64 | Electrical & Water Pit chamber Construction: |
| 65 | Providing and construction of Electrical Cable Pit of size 600x600x900 including PCC to be carried out at base, brickwork, SFRC cover and its frame over the chamber, leaving space for GI pipe fixing complete in all respect as per technical specification, construction drawings and direction of EIC. |
| 66 | [1. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials including laying, jointing of pipes, earthwork etc. with all bye works and sundry works |
| 67 | External water piping system (Borewell Connection) |
| 68 | Supply, laying and commissioning GI water supply piping (Heavy Duty, Tata / Jindal / Indus make) with all fitting such as garden irrigation fittings, water meter, water connection, and all other fittings including earth cutting, filling, disposal of surplus earth, bore well 150 mm dia, 250 meter depth and submersible pumps CRI make 3 h.p. including all accessories, panel, wiring all complete in all respects as per scope of work, detailed drawings, technical specificationsand directions of the Engineer-in-Charge. |
| 69 | BLDG PORTA CABINS . PORTA CABINS |
| 70 | Fabricating supply and installation of Porta Cabins as per Drawings The following details are being specified for reference purpose and to be followed on development of Portable cabin. However, mngl reserves the right to effect the minor changes as per site requirement and availability of material. The contractor is requested to understand all details on the construction material as well as arrange to get the porta cabin inspected during fabrication and also on completion.1. Shell : The shell will be fabricated from quality steel duly welded, comprising of base frame, peripheral structure and self draining roof. One entry door and 3windows. The eight corners are sufficiently strengthened to facilitate transportation, lifting and placing.2. Base Frame : The base frame is made of pressed mild steel channel section. The main structural element having 150 mm x 75 mm I beam and cross members are of ISMC 75 #C# channels.3. Side and End Walls : The side and end frame is made out of mild steel pressed sections of suitable profiles / pillars of suitable strength.4. Flooring Systems : On the bottom frame 19 mm thick Marine Plywood, of approved quality is fixed by means of self tapping screw. PVC Vinyl Sheets are fixed on this for Floor covering. 5. Roof : Self draining type rood is made out of 1.6mm thick MS Sheet, Adequate roof bows are provided. Roof is adequately chambered for draining of rain water.6. Insulation : 50 mm Thick Glass Wool/Rock Wool/ PUF / thermo Cole is used for walls and 75 mm thick insulation material is used for roof.7. Inner paneling : The interior will be aesthetically finished so as to give custom built appearance with extremely high quality workmanship.8. Windows : The provision of 2 No. window. |
| 71 | Plaster in CM 1:4 |
| 72 | Providing and laying 12 mm thick cement plaster on walls,RCC beams, columns and chajja etc of mix 1:4 ( I cement, 4 fine sand) including making of typical grooves drip-course including hacking of RCC roof beams and columns surfaces and curing etc. The job includes the cost of supplying and fixing of chicken wiremesh at every joint of brick masonry and RCC before commencing the plastering work complete in all respect as per scope of work, detailed construction drawings, technical specifications and directions of the EIC. |
| 73 | Providing and laying 19mm thick cement plaster on walls,RCC beams, columnsetc of mix 1:4 ( I cement, 4 fine sand) including making of typical grooves drip-course etc including hacking of RCC roof beams and columns surfaces and curing etc. complete. The job includes the cost of supplying and fixing of chicken wiremesh at every joint of brick masonry and RCC before commencing the plastering workcomplete in all respect as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-in-charge. |
| 74 | Painting( APEX / Weathercoat / Weathershield) |
| 75 | Supplying and applying 3 coats of Apex paint of Asian paints /Weathercoat of Berger paints / Weathershield of ICIpaints on external walls surfaces in approved colour at all heights as per scope of work and recommendations of manufacturer including surface preparation, primer putty etc. detailed construction drawings , technical specifications and directions of the Engineer-In-Charge. |
| 76 | [Rate to include priming coat of putty, scaffolding, tools & tackles, consumables etc complete. ] |
| 77 | Painting (OBD) |
| 78 | Supplying and finishing internal walls and ceilings in plaster of paris punning to achieve an even finish and applying 3 coats of Oil Bound Distemper of Asian paints/ Berger/ICIbrandin approved colour including surface preparation, primer, putty etc. as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-In-Charge. |
| 79 | White washing |
| 80 | White washing with Dehradun/Rajasthan lime in 3 or more coats to give an even finish including the cost of adding required adhesive (DDL), blue pigment (Robin Blue) etc. on walls, ceiling etc. complete in all respects as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-in-charge. |
| 81 | Providing and fixing Granite Stone over Dispenser Island& stair case |
| 82 | Providing and fixing 20 mm thick polished, machine cut granite stone for dispenser islands of required size and approved quality laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement , mixed with matching pigment, epoxy touchups, including rubbing, making edge moulding, curing etc all complete as per detailed construction drawings, technical specifications and directions of the Engineer-In-Charge. |
| 83 | IPS Flooring |
| 84 | Providing and laying 60 mm thick cement concrete floor with M-20 (1 cement : 1.5 coarse sand :3 stone aggregate of 12 mm nominal size) with a floating coat of neat cement all complete as per detailed construction drawings, technical specifications and directions of the Engineer-In-Charge. |
| 85 | [Rate to include all labour tools, tackles, hire charges, water charges PVC/glass strips etc complete.] |
| 86 | WEARING COURSE OVER RCC FLOOR |
| 87 | Providing & laying in panels 50 mm thick, 1:1:2 ( 1 cement, 1 fine aggregates, 2 (6mm) coarse aggregate ) screed with wire mesh of 4 mm thick & 75 mm square over RCC floor, all complete as per scope detailed drawings, technical specifications and directions of the Engineer-In-Charge. |
| 88 | Polycarbonate sheeting: |
| 89 | Providing and fixing 4 mm thick multiwall polycarbonate sheets of required canopy roof shapes and sizes and erecting them on roof/facia at proper position, all work as per specification, drawings and direction of EIC. |
| 90 | [1. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials, with all bye works and sundry works]. |
| 91 | Providing and fixing ceramic glazed wall tiles. |
| 92 | Ceramic glazed wall tiles of the approved size and of the appropriate specification shall be fixed in the walls using mortarwith proper finishing as mentioned ias per scope of work, detailed construction drawings, technical specifications and direction of Engineer-in-charge. |
| 93 | Providing and fixing vitrified tiles 600 x 600 mm. |
| 94 | Vitrifiedglazed floorl tiles of the approved size and of the appropriate specification shall be fixed in the floor over the subbase, pointing, cutting, curing and proper finishing as per scope of work, detailed construction drawings, technical specifications and direction of Engineer-in-charge. |
| 95 | [Rate to include all labour, tools, tackles, hire charges, water charges etc complete.] |
| 96 | Steel structure fabrication |
| 97 | Supplying, Fabricating & Erecting in position steel structures fabricated out of MS Girders, channels, Tees, angle, flats, plate, square hollow sections pipes etc. conforming to IS:2062 and/or from pipes conforming to IS:1161 for structural purpose for cascade supporting structure, loading/unloading platform, Gratings for platform, handrails, hoardings for signage, safety signboards,etc. of any size/dial for required design including cutting, welding, bolting,hoisting, fixing in position, and applying two or more coats of approved quality synthetic enamel paint over a priming coat of approved steel primer etc complete as per scope detailed drawings, technical specifications and directions of the EIC. |
| 98 | Providing and fixing Fencing Structure |
| 99 | Supplying, fabricating & fixing steel structural fencing fabricated from pipes conforming to IS:1161 and plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, painting with enamel paint in approved shade including supply of all raw materials, bolts, electrodes, transportation, including making pockets & pouring with PCC (1:2:4) in of block 500x500x500 for fixing of postsetc complete as per enclosed sketch, technical specifications and directions of the EIC. |
| 100 | Fencing height up 2.1 |
| 101 | Providing and fixing Fencing Gates |
| 102 | Supplying, fabricating & fixing fencing gates fabricated from pipes conforming to IS:1161 and plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, painting with enamel paint in approved shade including supply of all raw materials, bolts, electrodes, transportation etc complete as per enclosed sketch, technical specifications and directions of the Engineer-In-Charge. |
| 103 | 2m Wide andfencing height up 2.1 |
| 104 | 4m Wide andfencing height up 2.1 |
| 105 | Providing and fixing chequered plate covers |
| 106 | Providing and fixing chequered plate in approved panel or over steel structure including cutting, welding, hoisting, fixing in position, and applying two or more coats of approved quality synthetic enamel over a priming coat of approved steel primer etc complete as per scope detailed drawings , technical specifications and directions of the Engineer-In-Charge. |
| 107 | Providing and fixing safety guard Dispenser /LCV |
| 108 | Providing and fixing safety guard with 100 mm heavy duty sta.steel Pipe (size 750 deep and 600 width inside) grouted with ready mix high strength grout mortar of approved manufacturer and painted with approved quality paint as per scope of work, detailed construction drawings, technical specifications and directions of Engineer-In-Charge. [Rate to include cost of all labour, tools, tackles etc. complete]. |
| 109 | Supplying, fabricating and erecting structural steel canopy (including canopy fascia with 4 mm thick ACP, Led Company Logo, ACP column cladding 4 mm thick including all signage work & ACM sheeting ) |
| 110 | Supply, fabrication, erection and handing over of structural steel fabricated canopy (85Kg/Sqmt +-15%) including roof sheeting as per specification, Pre-coated Steel false ceiling system with powder coated finishes as per manufacturers instruction and specification, gutters, facia, flashings, Rain water pipes and gutter, painting, complete in all respects as per scope of work, detailed construction drawings, technical specification and directions of Engineer-in-charge. (Plan area shall be considered for measurement.) Rate Included in item for Supply, fabrication, erection and handing over of 4MM thick, 1MM Wide and approximate 68RM ACP Canopy Facia along with approximate 60 SQMT column cladding by 4mm thick ACP sheet. |
| 111 | Providing and fixingAl glazed framing Door. |
| 112 | Supply, transportaion, fixing in place the aluminium glazed framed door of approved make in the masonry wall as per the procedure laid down in the tender document at the locations specified by Engineer In Charge. |
| 113 | [Rate to include all material, labour, tools, tackles, hire charges, water charges etc and all the necessary things that are required for completing the job in all respect .] |
| 114 | Design, Supply, transportation, installation, testing & commissioning of Monolith as per approved design drawings, scope of work, tender document and as per direction of EIC. |
| 115 | Design, supply, transportation, installation, testing and commissioning of monolith : 3mm thick ACM (Aluminium Composite Material) panel router cut cladding on M.S. framework (hollow steel sections as per design requirement) with 4 nos. backlit panels on both sides in 3mm thick PET-G (Spectra Copolymer! Relstar). PET-G panels shall be of appropriate approved colour and cutouts for product names, logos, etc. The body of the monolith shall be in 3mm thick ACM in colour and shape as per approved design. The company logo should be prepared in polycarbonate sheets (GEl LEXAN make) in corporate colours and thermoformed to form the design which shall be in turn fixed in cutouts made in monolith body of ACM. The portions of the monolith to be backlit to make the acrylic polycarbonate portions! logos visible at night. Special spot lights (2 nos. - 400 watts with metal halide lights of Philips make) to be incorporated in design to light up the entire tower with throw from base. The backlit portion of the monolith to be lit with sufficient numbers T5 (28 W) tube lights (Philips make) with electronic choke, mounted on MS tube frames with plastic holders. Multi strand copper conductors with PVC insulation to be used. Steel structural frame to be installed on RCC foundations. All work to be done in line, level and plumb. The total work should be carried out as per approved design drawings, scope of work, tender document and as per direction of EIC. |
| 116 | Note:1. Rate to include designing (including structural design) supply, fabrication and installation of Monolith tower with all material and framework at site, ACM cladding as per the approved design including thermoformed PET-G, acrylic! Polycarbonate sheet, adhesive, rivets, bolts, nuts, screws, washers, tube lights, choke, all civil and structural works, conductors, connectors, etc. all inclusive.2. Item also to include cost of labour, transportation, erection, assembling, hoisting, launching, tools, tackles, jigs, scaffolding, framework, and all other consumable that might be required to complete the job.3. Peal-off protective film of ACM to be removed at site after final inspection.Mode of measurement: Per unit installed at site as per the designs and specifications.4. RCC foundation for monolith will be paid in separate item. (However drawing for the foundation is to be provided by bidder.)5. The above rate are inclusive of all the taxes and duties that are applicable. |
| 117 | Warehouse shed in steel structure with corrugated 0.8mm thik coadted GI sheet.(up to 9 mt Supply, fabrication, erection and handing over of structural steel fabricated Coverd Shed(50Kg/Sqmt +-20%) including roof sheeting as per specification, with powder coated finishes as per manufacturers instruction and specification, gutters, facia, flashings, Rain water pipes and gutter, painting,Lighting ,Cableing ,B/W ,Plaster,painting , Foundation & over All civil electrical work complete in all respects as per scope of work, detailed construction drawings, technical specification and directions of Engineer-in-charge. (Plan area shall be considered for measurement.) Rate Includedin all work. |
| 118 | Kerb stone fixing Providing and fixing kerb stone of approved make (kerb stone blocks shall have niche with reflective material fixed in it) at ground level as per approved pattern and setting in position with cement mortar 1:3 (one cement : 3 coarse sand) including the cost of required centering, shuttering and finishing smooth over 75 mm thick PCC 1:4:8 (1 cement : 4 coarse sand : 8 stone aggregate 40 mm), painting with emulsion paint of approved brand and colour complete in all respects as per scope of work, detailed construction drawings , technical specifications and directions of the Engineer-In-Charge. |
| 119 | [ Rate to include all labour, tools, tackles, shuttering, transportation, water charges, earth work if any , PCC, painting etc complete] |
| 120 | Polysulphide filling in Joints |
| 121 | Providing and placingpolysulphide sealant, over 12x38 mm thickness of Capcell- of supreme make in the expansion joints in the panels of forecourt and other specified locations; including sand fill, edge preparation by machine cut, cleaning, drying complete in all respects as per scope of work, detailed construction drawings, site sketches, technical specifications and directions of Engineer-In-Charge. |
| 122 | Providing and layingCapcell board |
| 123 | Providing and laying Capcell of Supreme make board sealing in expansion joints of 25 mm thickness & depth upto 100 mm at all locations; including sand fill, edge preparation, cleaning, drying complete in all respects as per scope of work, detailed construction drawings, site sketches, technical specifications and directions of Engineer-In-Charge. |
| 124 | EXTERNAL DEVELOPMENT |
| 125 | Providing and planting turfs, Wall other plant material, pesticides, sweet soil as per design and specifications complete in all respects as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-in-charge. |
| 126 | Providing and Construction of Rain Water Harwesting Pit including 40M Deep Bore well 150MM Dia with all Associated Works as per approved design drawings, scope of work, tender document and as per direction of EIC. |
| 127 | Supply, installation & fixing of Speed breaker as per drawing, technical specification, tender document & direction of Engineer in Charge |
| 128 | Supply & laying of G.I. Pipes buried/embedded into ground/ RCC/PCC complete with pipe sockets/ bends etc. as required of following sizes. All pipeshall be of medium grade as per IS:1239. |
| 129 | 100 mm NB |
| 130 | Supply & laying of perforated G.I.trays of following sizes as per technical specification. |
| 131 | 450 mm wide |
| 132 | Supply & laying ofBlack HD PVC. Pipes buriedfor dranege/other work. |
| 133 | 200 mm NB |
| 134 | 150 mm NB |
| 135 | 100 mm NB |
| 136 | ROAD WORK |
| 137 | RCC M-20 in DRIVEWAY (RATE include. cost of 80 -100 kg re-inforcement and shut. With GP2) |
| 138 | DWAY BITU PREMIX CARPET 50TK |
| 139 | DWAY BITU SEAL COAT 25TK |
| 140 | Design, supply, installation, testing & commissioning of Electrical distribution panel as per specifications & single line diagram (Drg. No. MNGL/PANEL/01, MNGL/PANEL/02, MNGL/PANEL/03 & MNGL/PANEL/04). |
| 141 | Power Distribution Board for Mother Station(DEPOT) 800 Amp |
| 142 | Emergency Panel for Mother Station(DEPOT) |
| 143 | Supply, installation, testing and commissioning of Wall Mounted Lighting DB.Double door construction. Constructed with 2 mm sheet steel enclosure along with a housing to mount the entire board. With required hardware, making connections including providing cable glands, lugs, earthing & Painting etc. arrangement for termination of cable / wires, including 3 phase and neutral bus bars etc. complete in all respects as per the tender document, technical specification, drawings and direction of EIC. |
| 144 | LDB - 1 (For Out Door Lighting) |
| 145 | Wall mounted ACDB for UPSIncomer: one no DP MCB 63Amp with Ammeter(Rating-0-30Amp) and indication lamp.Out going: 03 nos.DP MCBs 3 Amp, 4 no.DP MCBs 16Amp and 2 nos.DP MCBs 6Amp |
| 146 | Supply, laying , testing and termination ofPVC insulated & sheathed, 1100V grade,armoured ,Aluminium/copper conductor cable of follwing sizes & type in surfacetrench./on wall/structural surface/in G.I. Pipes/conduit as specified / required as per the tender document, technical specification, drawings and direction of EIC. |
| 147 | 3½ x 300 mm2AYFY |
| 148 | 3½ x 185 mm2 YRY |
| 149 | 3½ x 120 mm2AYFY |
| 150 | 3.5 x 50 mm2 AYFY |
| 151 | 3.5 x 75 mm2 AYFY |
| 152 | 4 x 6 mm2 YRY |
| 153 | 4 x 2.5 mm2 YRY |
| 154 | 2 x 2.5 mm2 YRY |
| 155 | 16 mm2 PVC insulated green colour copper conductor single core wire |
| 156 | Supply, installation, testing & commissioning of Flame Prof Lighting poles of 8 M height as per the enclosed drg. equipped with light fittings of type MRX51 (Philips,Nima or equivalent) 70W (LED FLP) and HPIT lamp complete with Plate earting , J.B. equipped with terminals for incoming/ outgoing cables and 2A, MCB, 4 x 2.5 mm2 YWY armoured cable from juction box to fixture including civil foundation as per the tender document, technical specification, drawings and direction of EIC. |
| 157 | Supply, installation, testing & commissioning of LED Lighting poles of 8 M height as per the enclosed drg. equipped with light fittings of type MRX51 (Philips, or equivalent)70W and HPIT lamp complete with Plate earting , J.B. equipped with terminals for incoming/ outgoing cables and 2A, MCB, 4 x 2.5 mm2 YWY armoured cable from juction box to fixture including civil foundation as per the tender document, technical specification, drawings and direction of EIC. |
| 158 | Supply, installation, testing & commissioning of canopy light with pole / bracket, flameproof fixture and control gear box, internal cable (4x2.5 mm2 YWY) from fitting to junction / control gear box to flameproof fitting, mercury vapour lamp etc. including civil foundation with pipe inserts for cables and connecting work, with all material and labour as per specification, drawings and instruction of Engineer-in-charge. |
| 159 | FLP Canopy lightSP - 13, Fixture : Well glass FLPW - 1095 for 250 W HPMV lamp. |
| 160 | Supply & laying of Copper Strip (for earthing) of following sizes, clamped to wall/structure& laying in trenches (as reqd.) including termination at the required points by welding/nut bolts including all earthing material as per the tender document, technical specification, drawings and direction of EIC. |
| 161 | 25 x 3 mm |
| 162 | Supply & laying of GI Strip (for earthing) of following sizes, clamped to wall/structure& laying in trenches (as reqd.) including termination at the required points by welding/nut boltsincluding all earthing material as per technical specification & drawings. |
| 163 | 40 x6 mm |
| 164 | Construction of Copper earthpit |
| 165 | Construction of Earthpits as per the drawing using GI pipe medium (class-B) 3M long, Copper plate of 600x600x3 mm size including supply of all material required and testing ofearth pits as per latest version of IS:3043, specification and drawing. |
| 166 | Construction of G.I. earthpit |
| 167 | Construction of Earthpits as per the drawing using GI pipe medium (class-B) 3M long,including supply of all material required and testing ofearth pits as per latest version of IS:3043 & specification & drawing. |
| 168 | Suppy, installation and commissioning of 3 KVA UPS |
| 169 | 3KVA non- redundant ,Single manufacturer\"s standard design UPS System suitbale for input power supply voltage of 230V +-20 % Single phase input single phase output with 4 hours batterybackup(VRLA-SMF 12V) and all interconnecting cables between UPS & Battery Bank,Stands for UPS and battery etc. 3KVA UPS system comprisingof 13KW rectifier/charger. |
| 170 | Supply, installation, testing and commissioning of Building Lighting and Power Plug Socket including concealed point wiring with havey duty PVC conduit earth wire,on/off switches etc as required as per technical specification & drawings. |
| 171 | 6/16 Amp Power Socket with 20A MCB,Four in one(Make Seimens or Equi.)4 sq. mm Cu. Conductor PVC insulated point wiring. |
| 172 | 20 Amp 3 Pin Industrial type socket with 20 Amp. SP MCB sheet steel enclosure with 4 sq. mm Cu. Conductor PVC insulated point wiring for air conditioner. |
| 173 | Horading & FCS 31/211 make Philips or equivalent |
| 174 | TMC - 501/136 |
| 175 | TMC - 501/236 |
| 176 | Wall Mounted Fan |
| 177 | Exhaust Fan(Size 300mm,Sweep)Industrial type |
| 178 | Exhaust Fan(Size 300mm,Sweep) |
| 179 | De watering pump (3P x6 H ) |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail