| 1 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 × 4 sq. mm + 1 × 4 sq. mm earth wire |
| 3 | Supplyof12\"(300mm)sweep1400rpmexhaustfanheavydutycompletewithshutters, blades etc as reqd. |
| 4 | Installationofexhaustfanintheexistingopening,includingmakinggoodthedamage connection testing, commissioning etc. as required.Upto 450 mm sweep |
| 5 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess,includingprovidingandfixing6pin5/6&15/16Amodularsocketoutletand 15/16 A modular switch, connections etc. as required. |
| 6 | SupplyinganddrawingfollowingsizesofFRLS PVC insulatedcopperconductor,singlecore cable in the existing surface/recessed steel/ PVC conduit as required. 3 x 4 sq. mm |
| 7 | SupplyinganddrawingfollowingsizesofFRLS PVC insulatedcopperconductor,singlecore cable in the existing surface/recessed steel/ PVC conduit as required. 6 x 4 sq. mm |
| 8 | Supply of S.P. 5/6 amps, one way modular switch, ISI marked |
| 9 | Supply of S.P. 15/16 amps, one way modular switch, ISI marked |
| 10 | Supply of 3 pin 5/6 amps modular socket outlet, ISI marked |
| 11 | Supply of 6 pin 15/16 amps modular socket outlet, ISI marked |
| 12 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts Ccurve DPMCBcomplete with connections,testing and commissioning etc. As required. |
| 13 | Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditionerscompletewithIndoorunit(IDU),Outdoorunit(ODU),surface/concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipeR-32/R-410/R407GreenRefrigerant,wirelessRemotecontrol,suitableforworking between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and PrintedCircuitBoard(PCB).Mustcomply:ElectricalcableIS694orIS9968temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressorIS10617,heatexchangerIS11329,capacitorIS2993andmotorIS12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operateupto500C (outdoorambienttemperature).InverterType-Coolingonly.1.5TRwith 5 Star BEE Rating |
| 14 | S/I/T/C of stand for split AC |
| 15 | S/I/T/C of copper pipe for split AC |
| 16 | S/I/T/C of Drain Pipe |