| 1 | Demolition of cement concrete (reinforced) of any desorption and in any position not otherwise specifically provided for, including cleaning, removal and disposal of rubbish / waste materials from premises, complete all as specified and as directed by Engineer-in-Charge. |
| 2 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exe 15cm. tickness below or above ground level complete all as specified and as directed by Engineer-in-Charge. |
| 3 | M& L for Cement concrete in foundations , Type D2 in CM 1:4: 8 using (40mm graded stone aggregate) filling andmass-concrete all as specified and directed. |
| 4 | M& L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter for rough finished Flat surface of concrete all as specified and directed. |
| 5 | M&L for Formwork to faces of walls, retaining walls, abutments, parapets and staircase railing and similar work including attached pillasters, buttresses, etc.; vertical or to batter to fair finished services , complete all as specified and directed. |
| 6 | M&L for Reinforcement cement concrete M-25 (Design Mix) in Foundations, including rafts, footings, foundation beams; plinth beams and wall bands ; bases for columns, etc; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed. |
| 7 | M&L for Reinforcement cement concrete M-25 (Design Mix) in Walls, retaining walls, basement walls, and the like; any thickness; above top of footings; including attached pilasters and buttresses, complete all as specified and directed. |
| 8 | M&L for TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 9 | M&L for TMT Mild steel bars 6 to 8mm dia bars, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 10 | M& L for roughening surface of concrete wall and rendering 10 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:4) finished even and smooth without using extra cement complete all as specified and directed. |
| 11 | Supply only integral water proofing compound. |
| 12 | M&L for Preparing surfaces of plastering or unplastered surfaces on walls andapplyingtwo coats of cement base paintover a coat of alkali resistance primer, complete all as specified and directed. |
| 13 | S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors all as specified and directed. |
| 14 | M& L for Framed brackets of angle or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and weldinig angles, as neceessary, Gusset plates, riveting, etc, n exc 10 Kg each brackets, conforming to Fe-410-0 or Fe-310-0 all as specifed and directed |
| 15 | M& L forPreparation of new steel surfaces over 10cm width or girth not otherwise described appling two coats of synthetic enamel paint over a coat of red oxide etc all as specified and directed by Engr-in-Charge |
| 16 | S&F Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strainingbolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. (each line wire to be measured) complete all as specified and directed. |
| 17 | S&F Concertina coil: 600 mm Dia/56 Loops/2.5 mm core wire. Coil Diameter: 600 mm. Type of Strip: Heavy Galvanized (IS 1730). Type of Core wire. Heavy Galvanized (15 280-2006). Core wire Diameter: 2.50 mm Dia. Zinc Coating to Strip. Minimum 200 GSM/Sqmm. Zine Coating on wire: Minimum 275 GSM/Sqmm (IS 6745-1972 reaffirmed 2006). Tensile Strength of wire: 1400-1500 N/Sq mm. Weight: 6-8 kg (+5%). Number of Loops 56 Blade Length: 22 mm. Barb Profile: Medium Blade (MBBT) Distance Between Barb: 35 mm. Stretchable length: 10-12 mirs, Type of clip Hardened Steelin Galvanized steel. all as speciified and directed by Engr-in-Charge |
| 18 | M&L for Pre-painted galvalume aluminum zinc coating Gl based plain steel sheet 50mm thick of any colourhaving tensile strength of 550 Mpa as in cladding to wall, fixed with self tapping screws as specified. |
| 19 | Supply only 25mm thick pre formed filler for crumple joints. |
| 20 | Excavation over areas, n exc 1.5 m deep and getting out in any type of soil all as specified and directed. |
| 21 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and directed. |
| 22 | Removing excavated material (Soil) n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed. |
| 23 | Note : Deduction of Schedule of Credit (Sch A Part II) to be made of Rs 2,28,656.30 form the total quoted amount of BOQ while accepting the bid. Details of Schedule of credit is given in Tender Documents. |