| 1 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting outin Soft/loose soilcomplete all as specified and as directed. |
| 2 | Surface dressing n. exc 30cm deep and averaging not exc 15cm deep in soft/loose soil complete all as specified and as directed. |
| 3 | Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting outin Soft/loose soilcomplete all as specified and as directed. |
| 4 | Excavating in post holes (or similar holes) n exe 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/loose soil andwatering and removing surplus soil to a distance complete all as specified and as directed. |
| 5 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and as directed. |
| 6 | Removing excavated material (soil) exc. 50m and not exc 100m depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed. |
| 7 | Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and as directed. |
| 8 | M&L for cement concrete1:3:6 type C2(using 40mm graded stone aggragate) asin foudnationfillingand mass concrete complete all as specified and as directed. |
| 9 | M&L for PCC in cement concrete in foundation, filling and mass concrete type D-2, 1:4:8 using 40mm graded aggregate as in foundation complete all as specified and as directed. |
| 10 | Material and labour for brickwork with fly ash bricks, old size, having compressive strength not less than 75Kg per Sqcm, straight or curved on plan exc 6 M mean radius inbuilt in cement and sand mortar 1:6 complete all as specified and as directed. |
| 11 | M&L for 15 mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm& 5mm) mixed with water proofing compound in top layer at the rate of 200 ml per bag of cement or as per manufacturer\"s instructions finishing the surface fair and even without using extra cement complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately. |
| 12 | Supply only liquid water proofing compound conforming to relevant IS complete all as specified and as directed. |
| 13 | M&L for rendering 15mm thick in CM 1:6 on brick or concrete surface finished fair and evenwithout using extra cement complete all as specified and as directed. |
| 14 | M&L for rolled mild steelwork in tubular trusses such as roof trusses, trussed, purlins, crane gantries, rails and fastenings and heavy bracket framingincluding distance pieces, cleats etcs including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St 240 complete all as specified and as directed. |
| 15 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 16 | M&L for preparation of new or previously untreated steel and Iron surface of any description, not otherwise described over 10 cm width or girth and applying two coats of Synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 17 | M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 18 | M&L for 100 mm thick cement concrete type D2 1:4:8with 40 mm graded stone aggregate as in sub base etc complete all as specified and as directed. |
| 19 | M&L for non skid coloured joint free ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but n. exc. 0.18 Sqm, in floors etc. set and jointed in neat cement slurry over 15mm thick screed bed or bedding layer in CM (1:6) as in floor and pointed in whiter or coloured cement to match complete all as specified and as directed. |
| 20 | Material and labour for glazed ceramic coloured/ digital printed/Elevation tiles of size 300 x 450 mm x 7 mm thick ) as in vertical surfaces of walls such as skirting/dado / riser to steps etc conforming to IS - 13712 grade IB-III set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over andincludingcement screed bed / backing layer of 10mm thick in cement mortar (1:4) complete all as specified and as directed. ( Note: Screed bed shall also deemed to be included in the quoted rate by the contractor ). |
| 21 | M&L for Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mmthick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. |
| 22 | M&L for 75 mm thick cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate in plinth protection finished fair and even without using extra cement including forming necessary joints 12 mm wide to the full depth of PCC at every 3 metres and every change of direction and filling the same with & including bitumen and sand 1:3 by weight of grade \"A\"complete with and including necessary form work etc complete all as specified and as directed. |
| 23 | M&L for PCC machine pressed precast apexstone, kerb stone, or similar articles of PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate), set and jointed and pointed in cement mortar (1:4) finished even & smooth using extra cement complete all as specified and as directed. |
| 24 | M&L for PCC (1:2:4) type B1 (using 20mm graded stone aggregated ) as in copping ,drains, bed plates etc of main holes including necessary form work complete all as specified and as directed. |
| 25 | M&L RCC M25 (design Mix) as in slab supported on walls, beam, columns in floor, roof, shalves complete all as specified and as directed. |
| 26 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc. flat rough finished surface of concrete complete all as specified and as directed. |
| 27 | Material and labour for Mild steel deformed or twisted bars ( TMT)8/10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire ( annealed) not less than0.90 mm dia. or higher complete all as specified and as directed. |
| 28 | M&L for 15 to 18 mm thick granite (of any type) work (table rubbed and polished) in steps, Jambs, pillars, window cills, cooking platforms, corner shelf, Flat shelf and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and including 15 mm thick cement plaster (1:4)including rounding the exposed surfaces of granite complete all as specified and as directed. |
| 29 | M&L forpreparation of new plastered surfaces on wall / ceiling / chajjas and applying Two coats of weather coat exterior pait over one coat of primer as per manufacturer instruction etc. complete all as specified and as directed. |
| 30 | M & L for preparation of surfaces of walls by washing, rubbing down and stopping of distempered and painted surfaces and distempering walls by applying two coats of acrylic based distemper of any tint/shade with roller over a coat of putty including primer complete all as specified and as directed. |
| 31 | M&L for 75 mm thick cement concrete type D2 1:4:8with 40 mm graded stone aggregate as in Sub base etcall as specified and as directed. |
| 32 | M&L for Paver tiles 10mm thick , set jointed and pointed in neat cement slurry over in pavement / footpath / floors over incl 15mm thick screed or bedding layer in CM (1:6) etc completeall as specified and as directed. |
| 33 | M&L for preparation of newly plaster/ concrete surfaces of wall and allying two coats of exteriior weather proof paint over one coat of primer over any tint on chequered cement tiles/ interlocking tiles / kerb stones surfaces including washing floors etc of drops and splashes complete all as specified and as directed. |
| 34 | S&F PVC (SWR) pipes 110 mm single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. |
| 35 | M&L for reinforced cement concrete M-25 (Design Mix) using 20 mm graded stone aggregate as in foundation including rafts,footing,foundation beams ,plinth beams,bases for colums,etc complete all as specified and as directed. |
| 36 | M&L for reinforced cement concrete M-25 (Design Mix) using 20 mm graded stone aggregate as in Columns complete all as specified and as directed. |
| 37 | Use and Waste of formwork for foundations, foundationbeams,lintel beam etc. for rough finished surfaces of concrete complete all as specified and as directed. |
| 38 | Use and waste of formwork to sides of columns,post ,struts,piers columns and stanchions complete all as specified and as directed. |
| 39 | Material and labour for Mild steel deformed or twisted bars ( TMT)6 to 8mmdia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire ( annealed) not less than0.90 mm dia. or higher complete all as specified and as directed. |
| 40 | M&L for reinforced cement concrete M-25 (Design Mix) using 20 mm graded stone aggregate as in floor & roof beams complete all as specified and as directed. |
| 41 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc. flat rough finished surface of concrete complete all as specified and as directed. |
| 42 | M&L for RCC M-25 in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed. |
| 43 | M&L for RCCdesign mixM-25 grade as in chajjas etc complete all as specified and as directed. |
| 44 | M&L for formwork to chajjas including edges in rough finished surface of concrete flat complete all as specified and as directed. |
| 45 | M&L for cement concrete 75mm thick type B-2 1:2:4 (40mm graded aggregate) complete all as specified and as directed. |
| 46 | S&F factory made Pressed steel frames confirming to IS, having profile of size 125 x 60 mm, 1.25 mm thick MS Sheetfor doors with one or more rebates including necessary supply and fixing lugs, lock strike plate, etc. 100 mm size hinges, with one shop coat of zinc chromate primer and fixing complete all as specified and as directed. |
| 47 | S&F of factory made 30mm flush shutter, machine pressed architects veneer designer ply lam both side flush door shutter solid core construction with block board core including 5mm thick teakwood lipping around complete all as specified and as directed |
| 48 | M&L for preparation of new or previously undecorated wooden surface of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of Pink primer complete all as specified and as directed. |
| 49 | S&F for factory made 30mm thick 2nd class hard wood gauged and skeleton shutter open rebated and prepared to received gauge etc (without sash bars) for fly proof door shutter, edges of framing plain, chamfered or rounded, fitted with cut of any mitered beads for securing gauge etc, size of members of shutter as specified in SSR Part-I section 8 clause No.8.23(a) and fitted to chowkats complete all as specified and as directed. |
| 50 | S&F factory made pressed steel windows and ventilators of standard size and section as shown on HQ CE Siliguri Zone Drg No CESZ/2018/TD-07, Sheet 1/3 to 3/3 with double shutter i.e. glazed & wire gauged shutter including all fittings like MS hold fast, box hinges, Handles, MS Tower Bolts, Stoppers, hinges, MS stay with long screw, MS spring latch, MS Guard Bar/ grill etc complete with glazing bars including one shop coat of zinc chrome primer complete all as specified and as directed.Note:- (i) Rate quoted shall be deemed to be including of all fittings fixtures.(ii) Glass, wire mesh and painting only shall be measured and paid separately under relevant items of Sch.(iii) The Drawings referred above are available in the office of Engr-in-Charge and can be refereed in the office working hours if required. |
| 51 | S&F of 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and as directed. |
| 52 | S&F 150 mm long Aluminium anodised barrel tower bolts of extruded section and fixedcomplete all as specified and as directed. |
| 53 | S&F of stainlesssteel butt hinges of size 100mm complete all as specified and as directed. |
| 54 | S&F of aluminium handles cast type anodised 150mm of size complete all as specified and as directed. |
| 55 | S&F in repair Aluminium alloy anodised sliding door bolt 200 mm long with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section complete all as specified and as directed. |
| 56 | S&F of stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned stacks, or galvanised wire staples etc complete all as specified and as directed. |
| 57 | M&L for treating the soil along with external perimeter of building at the rate of 2.25litof emulsion per meter of perimeter wall complete all as specified and as directed. |
| 58 | M&L for treating the backfill in contact with foundation at the rate of 7.5 liters of emulsion per square meter of vertical surface (area of sub structure in contact with backfill to be measured) complete all as specified and as directed. |
| 59 | M&L for treating the top surface of filled earth at the rate of 5 liters of emulsion per square meter of surface complete all as specified and as directed. |
| 60 | M&L for treating the soil under plinth protection at the rate of 5 liters of emulsion per square meter of surface areacomplete all as specified and as directed. |
| 61 | M&L for rendering 5mm thick plastering in CM (1:3) on ceiling, soffits of slabs, chajjas, columns and beams etc and finished the plastered surface even and fair without using extra cement complete all as specified and as directed. |
| 62 | M&L for preparation of new surface applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. |
| 63 | M&L for preparation of old treated surface of ceiling by brooming down or steel wire brushing; scrapping down smoke root, moulds, moss and efflorescent salts and treating oil and greasy spots and applying two coats of colour wash on old decorated surfaces of ceiling including washing floors, cleaning glass, joinery, electrical fittings, wiring etc of drops and splashes complete all as specified and as directed. |
| 64 | M&L for non skid coloured joint free ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but n. exc. 0.38 Sqm, in floors etc. set and jointed in neat cement slurry over 15mm thick screed bed or bedding layer in CM (1:6) as in floor and pointed in whiter or coloured cement to match complete all as specified and as directed. |
| 65 | M&L for 10mm thick screed bed or bedding layer in cement mortar (1:4) mixed with WPC in order to maintain proper slope over existing roof surfaces for applying roof treatment, finished even and smooth without using extra cement complete all as specified and as directed. |
| 66 | M&L for water proofing treatment to sunken floor with the following course of treatment / specification :- (i) Cleaning top surface offloors / slabs and laying 50mm thick (avg) PCC of grade M10 (Nominal mix), mixed with WPC as per manufacturer\"s instruction laid in slope 1:20 towards spouts including coveting corners. (ii) 15mm thick plastering in CM (1:4) on sides mixed with WPC as per manufacturers instruction. (iii) Applying 1st layer of slurry @ 0.488 kg/ sqm mixed with acrylic based polymer modified cementious compound @ 0.253 kg / sqm , this layer shall be allowed to air cured for 4 hrs . ( iv) Applying 2nd layer of slurry @ 0.242 kg/ sqm mixed with acrylic based polymer modified cementious compound @ 0.126 kg / sqm , this layer shall be allowed to air cured for 4 hrs followed with water curing for 48 hrs.(v)Applying a coat of industrial bitumen 85/25 penetration @ 1.50 kg/sqm on plastered and concrete surfaces. (vi) Providing 150 micron thick polyutethene paint in two coats ( each of 75 micron measured dry surface over a coat of PU primer including preparation.(Make of PU primer- Dek guard EP - 302 of m/s Fosroc or techno commerciallyequivalent makeas listed in list of makes and approved by GE. Make of PU paint- Dek guard PU or techno commerciallyequivalent makeas listed in list of makes and approved by GE (vii) Sunken floor shall be tested for water tightness by filling water for 72 hrs before and after treatment work is carried out and ensure that no leakage / seepage exists. (ix) Sunken portion shall be filled with lean concrete of grade M 7.5 stone aggregate. (Note : (i)Treatment shall be carried out by authorised applicator approved by the manufacturer., (ii) Only floor area should be measured for payment) |
| 67 | S&F for solid PVC door frame (single rebated) of size 60x30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer intigral skin with suitable metal stiffner and fixed with 100x8 sheet metal CSK screw complete all as specified and as directed. (Note : Door frame shall be water proof, termite proof eleganr and should have excellent screw holding strength to fix hinges and hold doors properly for a long life.) |
| 68 | M&L factory maded solid PVC profiled panel door shutter 28mm thick intigral skin as frame & 3mm thick high pressure compact laminate on both side of approved colour as infill with \"C\" type GI or 40x20x19 of MS pipe as stiffner & S&F in frame at site complete all as specified and as directed. |
| 69 | S&F 75 mm size butt hinges mild steel medium weight cold rolled complete all as specified and as directed. |
| 70 | S & F 100mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed. |
| 71 | S&F aluminium handles 100mm size cast type anodised complete all as specified and as directed. |
| 72 | M & L for 75mm Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed. |
| 73 | S&F 110mm dia PVC bends of bends of any radius complete all as specified and as directed. |
| 74 | Roughening the surfaces of old concrete floor by picking, sweeping, cleaning and washing down with water to remove dust and brushing neat cement slurry with 3.0 kg of cement per Sqm complete all as specified and as directed. |
| 75 | M&L for machine cut kota stone slab flooring 18-20 mm thick over 15 mm thick cement screed bed cement mortar 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. |
| 76 | All as per item No 75 above but in riser of steps, skirting, dado and pillar etc complete all as specified and as directed. |
| 77 | M&L for sand filling under floors or in foundations including watering and consolidation including Spreading and leveling in layers n exc. 40 mm thick complete all as specified and as directed. |
| 78 | S&F for Pre-painted galvalume aluminum zinc coating GI based Plain or curved crimped steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwsincluding all necessary accessories compete all as specified and as directed. |
| 79 | M&L stone kerb of roughly squared stones of size 20cmx30cm dressed so that the maximum depression from a straight edge against the surface shall not exceed 6mm for top and exposed surfaces of sides and 20mm for the rest of surfaces jointed in cement mortor 1:6 and flush stuck complete all as specified and as directed. |
| 80 | ELECTRIFICATIONM&L for point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including PVC conduit of adequate size with allaccessories (including cutting chases & making good the disturbed surface to its original specification) including MS sunk box, 3mm thick hylum sheet top cover fixed by means of brass machine screw and cap washer including size 1.5 sq mm (nominal cross sectional area) PVC insulated unsheathed single core multistranded copper conductor cable as earth continuity conductor connected to main switches/DB\"s or common earth dolly complete all as specified and directed for the following :- One light point controlled by one way switch 5/6 amps. |
| 81 | All as per item No 80 above but one ceiling fan/Exhaut fan point controlled by one way switch 5/6 amps. |
| 82 | All as per item No 80 above but one socket out let 5/6 amps point on the independent board. |
| 83 | All as per item No 80 above but one socket out let 5/6 amps point on the same board |
| 84 | All as per item No 80 above but wiring with 2.5 sq mm single coremultistranded copper conductorincluding provision of 2.5 Sqmm PVC insulated multistranded unsheated copper conductor cable FR-LS (ISI markd) with proper colour coding as earth continuity conductor connected to common earth dolly , for one socket out let 15/16 amps point on the independent board complete all as specified and directed |
| 85 | S&F of switch piano flush type 5/6 amps single pole one way complete all as specified and as directed. |
| 86 | S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and as directed. |
| 87 | S&F of Switch socket combination2 and 3 Pin, 5/6 amps, multipurpose flush non shutter, non inter locking type white ivory finish with and including taking down existing unserviceable complete all as specified and as directed. |
| 88 | S&F of Switch socket combination2 and 3 Pin, 15/16 amps, multipurpose flush non shutter, non inter locking type white ivory finish with and including taking down existing unserviceable, complete all as specified and directed. |
| 89 | S&F of ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and as directed. |
| 90 | S & F of deluxe fan Electronic regulatorAC 50 Hzs rotary stepwhite/ivory finish complete all as specified and directed. |
| 91 | S&F of LED tube lightfittings 1 x 18/20watts energy efficient T5, 230 Vincl 1x18/20 watt LED tube, epoxy powder coated CRCA sheetbipin holders, connector block etc, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable. |
| 92 | S&F ofLED street light luminaires 35 Watts IP 66 type incl standard fittings pressure die cast aluminium housing with heat reistant toughened glass housing with epoxy powder coated finsh and , complete with Electronic driver and all accessories duly prewired and connecting to cealing Rose with and including GI Pipe 32 mm dia light grade bend to required shape, clamps, bolts and washers complete all as specified and as directed. |
| 93 | S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, Single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\"S/isolators complete all as specified and as directed. |
| 94 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\"S/isolatorscomplete all as specified and as directed. |
| 95 | S&F in repair MCB, Single pole & neutral, 32 amps, 240 volts, ‘C’ curve, 10KA allcomplete as specified and as directed. |
| 96 | S&F MCB, Single pole, 6 to32 amps, 240 volts, ‘C’ curve, 10 KAallcomplete all as specified and as directed. |
| 97 | Material and labour for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, checknuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, includig necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 3 of SSR Part- I including testing on completion all as directed and as specified. |
| 98 | Supply, laying, jointing andtestingLT underground electric power cable crossed linked XLPE insulated, two or more core galvanized steel strip or wire armored / PVC insulated armored cableheavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 6 sqmm 2 core laid in trenches / laid under floor or fixed to walls/on poles / in ducts or passing through pipesetc fixing and connecting accessories such as Aluminium cable lugs, cable glands, nut, bolts, washers etc complete all as specified and as directed.Note:Earth work, excavation, GI pipe, sand cushioning and protection brick shall be measured and paid separately under appropriate items. |
| 99 | Supply and lay dry river sand filling for under ground cable protection with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified and as directed. |
| 100 | Supply and laying sub class B bricks of size 25cmx12.5cmx7.5cm for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed. |
| 101 | Supply & fix Ceiling fans with all accessories 230 V,1200 mm sweep BEE 5 star rated, conforming to IS 374:1979 complete with pre wired with 3 core cable completion all as directed and as specified. |
| 102 | Supply, laying, jointing andtestingLT underground electric power cable crossed linked XLPE insulated, two or more core galvanized steel strip or wire armored / PVC insulated armored cableheavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 10 sqmm 2 core laid in trenches / laid under floor or fixed to walls/on poles / in ducts or passing through pipesetc fixing and connecting accessories such as Aluminium cable lugs, cable glands, nut, bolts, washers etc complete all as specified and as directed.Note:Earth work, excavation, GI pipe, sand cushioning and protection brick shall be measured and paid separately under appropriate items. |
| 103 | M & L for horizontal boring across the existing road without disturbing the road surface for insertingGI pipe of 50mm bore complete all as specified and as directed. Note :- (i) Removal of surplus soil shall be deemed to be include in the unit Rate. (ii) GI pipe will be measured and paid separately under relevant item of Sch \"A\". |
| 104 | M&L for 50 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and as directed. |
| 105 | S&F IP 20, class I, LED light 1X18 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting upcomplete all as specified and as directed. |
| 106 | S&F Sheet metal enclosure for 2 way Distribution Boards (DB’s), double door, Single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\"S/isolators complete all as specified and as directed. |
| 107 | S&F MCB, Single pole & neutral, 35 to 63 amps, 240 volts, ‘C’ curve, 10KA allcomplete as specified and as directed. |