| 1 | M & L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 all as specified and directed. |
| 2 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and fair complete all as specified and directed. |
| 3 | M & L for Providing and applying one coat wall care putty upto achieve the surface even and smooth for painting complete all as specified and directed. |
| 4 | M & L for preparation of plastered surface distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s instructions |
| 5 | Material & Labour for preparation of finished walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. |
| 6 | S&F Solid PVC Wall Lining consisting of 5 to 8 mm thick any colour/ designs ofPVC sheet incluseive of solvent cement and fixing at site on PVC frame as per specifications and drawing including taking down wall panelling and similar work complete all as specified and directed. |
| 7 | S & F 5 mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed. |
| 8 | S & F in Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions and aluminium section joint with tia rod at corner in frame of door) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom andsideswithrequiredEPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Chief including necessary require fitting complete all as specified and directed. |
| 9 | S & F powder coating of any colour (minimum thickness of powder coating not less than 50 micron) anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed. |
| 10 | S&F in repair two(double) legged floor door stopper of aluminum body & tougues with hard drawer steel spring fixed in floor of 140mm complete all as specified and directed. |
| 11 | S & F for 4.8 mm sheet glass ordinary quality and glazing with oil putty in square n exc 0.5 Sqm in each pane including necessary require fitting complete all as specified and directed. |
| 12 | S & F for 4 mm thick Figured glass, pin head type and glazing with oil putty in squares exc 0.5 sq. m in each pane including necessary require fitting complete all as specified and directed. |
| 13 | S&F in repairs \"E\" board everest 600 x 600 x 4mm thick white, prelaminated sett embossed reinforceddesigner ceiling board tiles of approved texture at all height laid on hot dipped GI imposed grid with 24mm wide T sec exposed flanges which shall be pestered coated white.The frame work shall comprise of main runner made from 0.33 mm thick GI sheet of size 24x32x300mm and spaced at 1200 mm C/C securely fixed to be structural soffits by approved hangers at 1200mm C/C.Hanger of GI wire 4 mm dia to be fixed by approved recoil plug, screw etc.The last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall. flash fitting of 1200 mm long cross tec (with double sticking) to be interlocked bet wean main runner at 0600 mm centre from 1200x600 mm to modules cross tec longer than 600 mm to besupported independency 600x600 mm do duels to be formed by filling 600 mm long cross tec centrally between the 1200 mm cross tec. Tec perimeter wall angle shall be of 0.45 mm thick GS sheet of size 19x19 mm and 300 mm long of white colour all as per manufacture instruction complete all as specified and directed. |
| 14 | M&L of Point wiring complete with 1.5 sqmm (nominal area) PVC insulated unsheathed multistranded copper condutor single core cable 1100 volts grade FRLSH ISI marked drawn through and incl non metalic PVC conduit, ISI marked of not less than 20 mm dia,Heavy duty , in PVC Conduit on wall/roof,/ on the surface along the roof as per requiremnt at site etc, with all connected fittings includingMODULAR WHITE COVER PLATE WITH FRAME - 1 module/ 2 module/3 module/4 module/6 module/8 module/12 module, etc., MODULAR METAL FLUSH BOX - 1 module/ 2 module/3 module/4 module/6 module/8 module/12 module, etc., and including FRLSH PVC insulated unsheathed multistranded single core copper conductor cable of size 1.5 sq mm green in colour as in earth continuity conductor connected to common earth dolly and all metal parts of fittings including connected to near by switchboard as specified and directed for the following:-Note:- modular switches, sockets, ceiling rose, regulators, etc shall be measured and paid separately. |
| 15 | One light/fan/point controlled by one switch |
| 16 | One 5 pin socket outlet independent 5 Amps |
| 17 | One socket outlet 5 Amps on the same board with other switches. |
| 18 | All as ser item ser No 14.00 , but for One 6 pin 5/15 Amps socket outlet independent with 2.5 Sqmm size copper conductor cable and2.5 sqmm copper cables as earth wire for Power Socket. |
| 19 | M&L of Sub main wiring with 2 runs of single core FRLSH PVC insulated unsheathed multistranded copper conductor cable of size 2 x 1.5 sqmm (line conductor) & 1x 1.5 sq mm (earth conductor), 1100 V grade drawing in & including heavy duty non metalic PVC conduit, ISI marked, incl accessories not less than 25 mm in dia & along with surface/wall, roof etc including PVC insulated, FRLSH unsheathed single core multistranded copper conductor cable, green in colour as in earth conductor including cutting charges for concealed conduit wiring etc and making good cutting not exceeding 10 cm grith complete all as specified and directed. Note : (i)Two runs of copper conductor cable and one run of copper earth wire including PVC conduit will be measured and paid as one unit only. (ii). Suitable size cable lugs copper fabricated will be measured in the quoted rate only. (iii). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate. |
| 20 | S&FModular switch 1 way 6 A, 1 module type single pole 240 volts and complete all as specified and directed by the Engr-in-charge. |
| 21 | S&F Modular socket 6Amps 2/3 pin combined 2 module240 Volts complete all as specified and directed by the Engr-in-charge. |
| 22 | Supply and fixing ceiling rose bakelite, 63.5mm3 terminals with base plate ISI marked, complete all as specified and directed by Engr-in-charge. |
| 23 | Supply and Fixing ceiling fans complete with blades,hangingrods ,electric regulator and accessories , 230V 1200mm sweep , Min air delivery 210 CFM with service value 6.00 BEE 5 Star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 24 | Supply and Fix Standard Wall Fan (400 mm sweep) 3-speed settings, pull cord operation, 100% copper motor, jerk-free oscillation, white finish as per the direction of engineer in charge. |
| 25 | S&F LEDtube light fittings 1 x 20 W, 230V, complete with all accessories internally prewired and including connecting up with twisted flexible PVC copper conductor cable of 23/0.0076 from ceiling rose all as directed by Engr-In- Charge. |
| 26 | S&F Sheet metal enclosure MCB SPN distribution board, double door, IP 53 class, including suitable size copper bus-bar, 240V,8 Way with shrouded neutral bar, earth bar and incld. cable ties and suitable size blanks, including taking down of existing sheet metal enclosure complete all as specified and directed. NOTE - (a). Cost of suitable size cable lugs and materials required for flush fixing of DB is deemed to be included in the quoted rate. (b). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate. |
| 27 | M&L for earthing complete with galvanized steel earth plate electrode 60×60cm×6mm thick electrode burried directly in ground (earth pit notless than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connected with 25 x 4 mm galvanized iron as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessaryexcavation & earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1, using 20 mm graded stone aggregate, provn of 40 mm RCC with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade GI pipe for watering, 40 mm dia light grade Gl pipe for lead protection in and including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-I (2009) connected to earthing test point all as specified and indicatedincluding testing on completion including retrieving of old GI earth plate, CI cover, GI pipes, angle iron frame from existing earthing as directed by Engineer-in-Charge. NOTE : - (i). Earthing strip GI/copper upto 7.5m will be measured and paid under this item only. (ii). The earth chamber shall be constructed 50 cm away from the edge of earth pit and the cost of the same is deemed to be included in the rate quoted for above item. (ii). Quoted rate is deemed to be inclusive of cost of demolition of old earthing as directed by Engr-in-Charge. (iii). The new earthing so constructed must have resisitance value below 2 ohms. If the aforesaid resistance value is not achieved contractor has to make proper aadditions/alterations to the newly constructed earthing at his own cost. |
| 28 | Supply and fixing MCB SPN 06-32Amps,10 KA \"c\" series 240 V ISI marked.complete all as specified and directed by Engr-in-Charge. Make: |
| 29 | Supply and fixingMCBSP 6 -32 Amps,10 KA,,\"C\" series 240 V ISI marked.complete all as specified and directed by Engr-in-Charge. |
| 30 | M & L MS work( clamp, Hook , nuts, botls for ceiling fan & exhaust fan) etc welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat ofpaintfor hanging with of Ceiling Fanall as specified and directed by Engr-in-Charge |
| 31 | Supply and fixing LED Building security light 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. |