| 1 | Repair to potholes of any depth, not exc 1 sqm each including sweeping free from dust, mud or water, scoring sunken surfaces in roads, paths, etc. cutting around edges to at least 25 mm in depth, making good by filling in screened & graded road metal, watering well ramming (including supply of road metal) making good by applying tack coat at 5 Kg per 10 sqm putting in premixed bituminous macadam, well rammed and sealed with binder 9.8 kg per 10 sqm, blinded with 0.09 cum of stone chippings, 6.3 mm size and again well rammed (including supply of premixed macadam, binder and chippings), depth of potholes exc 30 mm complete all as specified and directed. |
| 2 | Material and labour for preparation of existing black top surfaces of road by brushing with wire brushes for removing caked mud etc, sweeping with brooms and finally fanning the cleaned surface with compressed air to remove all loose, dirt etc, complete all asspecified and directed. |
| 3 | M&L for applying evenly priming/tack coat with butuminous primer at 5 Kg per 10 Sqm using paving bitumen VG-30 onold bituminous carpet surface complete all as specified and directed |
| 4 | M&L for 7.5 cm thick (compacted thickness) WBM, with coarse aggregate of grading 2 (63 to 40 mm size) or of grading 3(50 to 20 mm size) granite trape or basalt, spread rolled & consolidated to gradient and camber required using vibratory power rolled exceeding 8 tonnes but not exceeding 12 tones capacity complete all as specified and directed. |
| 5 | M&Lfor preparing surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags unsurfaced water black top bound macadam to remove all loose dirt etc. paving bitumen, applying evely a priming/tack coat with bituminous primer at 10 Kg per 10 Sqm metre complete all as specified and directed. |
| 6 | M&L for bituminous premixed semi asphaltic dense concret 40mm thick (consolidated thicknes) with 5.50% binder content (paving bitumen VG-30 grade) by weight of toal mix, mixed in vetical computrized hot mix plant and laid using mechanical self propelled paver and rolled with 8 to 12 tonne power rolller to required camber and gradient all as specified and directed |
| 7 | M&L for applying 25 mm thick mastic asphalt consisting of an intermidiate homogenous mixture on mineral filler, well graded fine and coarse aggregate industrial grade 85/25 bitumen as per IRC 2013 cooked at 170 C to 200 C laid hot trowelled and floated and floated by means of wooden float bitumen mastic afer spreading and while still hot in plastic condition shall spread over with bituminous precoated fine aggregate of size 20mm @ 0.005 Cum per 10 Sqm mixed with 0.17 Kg per Sqm of industrial bitumen grade 85/25 for antistaciding including all material, labour, tools and plants complete all as specified and directed. |
| 8 | M&L for Premis bituminous, macadam with binder content 4% (Paving Bitumen) by wt of total mix laid/rolled and compacted to required gradient and camber (consolidated thickness 75 mm or less) complete all as specified and directed |
| 9 | M&L for preparing bituminous surfaces of road and marking 2.5mm thick centre lines, stop lines, dashes, arrows etc. and the like n.exc 10 cm wide on roads pavements withhot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed. |
| 10 | Spply and fixing for cat for eye solar reflective type of metal body alloy of size 100mm x100mm x 20mm with PAMA striplens reflector of model NO DA 972.0 fixed with and including MS stud of suitable size as per manufacture instructions complete all as specified and directed. |
| 11 | Supply and fix for solar cat eye alumimum alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono rystafie solar panel 2.4V/03 watt one NI-ed rechargeable battery (1.2V/1600MA)) consisting of super bright LED with 10,000 to 18,000 mcd completed as per manufactures instructions etc, all as specified and directed. |
| 12 | M&L for 100mm thick cement concrete (1:2:4), type B2 (using 40mm graded stone aggregate) as in floors finishing the surfaces even and fair without using extra cement complete all as specified and directed. |
| 13 | M&L for hardcore of gauge n exc 63mm, deposited, spread and levelled with broken bricks in layers n exc 15 cm thick, watered and rammed to a true surface with broken bricks complete all as specified and directed. |
| 14 | Providing and laying 60mm thck factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design &pattern as in footpath, parks, lawns drive ways or light traffic parking etc, of required strength, thickness & size / shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. |
| 15 | Providing and layingat or near gound level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 16 | Demolition of Cement concrete of any description and in any position not otherwise specifically provided for complete all specified and directed. |