| 1 | Dismantling of ACSR conductors of any size complete all as specified and directed. |
| 2 | Dismantling of earth wire and craddles of any size complete all as specified and directed. |
| 3 | Dismantling of insulators any type any size complete all as specified and directed. |
| 4 | Dismantling of cross arms of MS angle section etc complete all as specified and directed. |
| 5 | Supply, laying and testing in replacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sqmm, 3.5 core including taking down existing unserviceable cable and removing from sitecomplete all as specified and directed. |
| 6 | All as per item No. 5 above but size of 70 sqmm, 3.5 core |
| 7 | All as per item No. 5 above but size of 50 sqmm, 3.5 core |
| 8 | All as per item No. 5 above but size of 35 sqmm, 3.5 core |
| 9 | All as per item No. 5 above but size of 25 sqmm, 4 core |
| 10 | All as per item No. 5 above but size of 16 sqmm, 4 core |
| 11 | All as per item No. 5 above but size of 10 sqmm, 2 core |
| 12 | Taking down and re-laying /re-routing of LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of any size laid in trenches or fixed on wall /floor/poles including taking out old unserviceable /serviceable bricks, cable covers, GI pipe of any size for reuse from trenches for removing complete all as specified and directed. |
| 13 | Excavation in trenches in hard/dense of soilnot exceeding 1.5 metre wide and not exceeding 1.5metre in depth and getting out complete all as specified and directed. |
| 14 | Excavation in trenches in hard/dense of soilnot exceeding 1.5 metre wide and exceeding 1.5metrebut n.exc. 3.0m in depth and getting out complete all as specified and directed. |
| 15 | Returning filling in with excavated soil, including spreading, leveling watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 16 | Removing excavated materials (soil) not exceeding 50metre and depositing where directedat a level not exceeding 1.5 meter above starting point complete all as specified and directed. |
| 17 | M&L for local sand cushioning with dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable and filling the sand in cable duct of inside the sub station building complete all as directed. Note:- Only punned thickness of 180mm shall be measured for payment. |
| 18 | Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250mm x 150mm x 40mm complete all as specified and directed. |
| 19 | Supply, installation, connecting, commissioning and replacement of LT panel with CPRI approvedmainfactory fabricatedLT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos suitable insulated bus bar made of high conductivity aluminium, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etcand comprising of the following:- |
| 20 | (A) INCOMING (i) MCCB, 4 Pole, 415V, 50HZ 250 Amps 25 KA electronic /microprocessor -01 No. (B) OUTGOING (i) Digital Multifuction meter withselector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED TypePhase indicator lamps for three phases set of three - 01 set (iii) Busbar chamber having insulated aluminium busbar, each suitable for 320 Amps for three phases and neutral -01 Set (iv) MCCB, 4 Pole,415V, 50HZ 160 Amps 16 KA fixed thermal and fixed magnetic -01 Nos(v) MCCB, 4 Pole,415V, 50HZ 63 Amps 16 KA fixed thermal and fixed magnetic -04 Nos(vi) Spare space for MCCB of same capacity -01 Nos |
| 21 | Supply, installation, connecting, commissioning and repalcement of LT panel with CPRI approvedmainfactory fabricatedLT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos suitable insulated bus bar made of high conductivity aluminium, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc and comprising of the following :- |
| 22 | (A) INCOMING (i) MCCB, 4 Pole, 415V, 50HZ 250 Amps 25 KA electronic /microprocessor -01 No. (B) OUTGOING (i) Digital Multifuction meter withselector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED TypePhase indicator lamps for three phases set of three - 01 set (iii) Busbar chamber having insulated aluminium busbar, each suitable for 300 Amps for three phases and neutral -01 Set (iv) MCCB, 4 Pole,415V, 50HZ 200 Amps 25 KA fixed thermal and fixed magnetic -01 Nos(v) MCCB, 4 Pole,415V, 50HZ 100 Amps 16 KA fixed thermal and fixed magnetic -04 Nos(vi) Spare space for MCCB of same capacity -01 Nos |
| 23 | Supply and fix40 watt,240 volts,5700 ANSI,decorative LED post top Lantern luminaire with diffuser and painted spun aluminium deflecter complete mounted on cast aluminium capsule type complete fix on suitable dia medium grade GI pipe withscrew/nut including taking out existing light fitting of any descriptions complete all as specified and directed. |
| 24 | Supply,fixing and testingcone LED Bollard light IP 65, 8 Watt complete all as specified and directed. |
| 25 | S & F of EROS POST TOP 70W aesthetically designed IP 66 LED Post top with aluminium enclosure powered with high power LEDs as light source and die casted heat sink exhibiting classic victorian look with symmetrical light distribution , suspended mounting arrangement and excellent heat dissipation for long life complete all as specified and directed. |
| 26 | S & F of EROS DECORATIVE ARMS orbit plus S Round single arms family decorative in different designs, shaped and length to compliment the eros LED Post top and poles family complete all as specified and directed. |
| 27 | S & F of EROS CASTING POLES 3MTRheight family of decorative casting poles in different designs, shaped and heights to compliment the eros LED post top family. These poles can infuse life into roads hight importance and visibility complete all as specified and directed. |
| 28 | S&F in repairs flat copper cable flexible of size 1.5 sqmm 3 core, 1100 volt grading complete all as specified and directed. |
| 29 | S & F of DECO POLES 3MTR pole height top 76mm family of in different designs, shaped and heights to compliment the eros LED post top family. These poles can infuse life into roads hight importance and visibility complete all as specified and directed. |
| 30 | Taking down old unserviceable LT PCC poles & Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP – 31) conforming to IS 2713 (part 1 to 3), 9 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers,including two coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint complete all as specified and directed. (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed).Note:(a) Cost of numbering of pole shall be deemed to included in unit rate.(b) Excavation,Earth work and PCC foundation will be measured and paid for separately.(c) The pole shall be marked with designation, manufacturer\"s identification and year of manufacture |
| 31 | M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) in foundation of PCC poles/struts as specified including necessary form work, complete all as specified & directed. |
| 32 | M&L for plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) in foundation of stay assembly etc including necessary form work, complete all as specified & directed. |
| 33 | M&L for plain cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) for coping around poles, including necessary form work finishing even and smooth without using extra cement, complete all as specified & directed. |
| 34 | Supply and fixing LED street light fitting90 Watt 230 V AC , efficiacy of LED 140 lm/W Sensor streetlight outdoor type with high pressure die cast aluminum hosing and heat resistantcomplete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete. |
| 35 | Supply and fixing in repairs LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 36 | M & L for carrying out boring under the black top road for crossing of LT cable/protection pipe by any means boring machine or otherwise without damaging black top surface of road for fixing of GI pipe 100/80mm bore under the road complete all as specified and directed. |
| 37 | Supply and fixing new 40 mmbore or next suitable size ( forLED fittings)light grade GI bracket 1.20 mtr long bent to shapeby cutting welding and well finishing including MS clamp of flat iron of size 25x5mm suitable length 2 nos complete for steel tubular poles with nuts bolts and painting with two coats of aluminium paint over a coat of primer on MS clampcomplete all as specified & directed. |
| 38 | Taking down old unsvjunction box and Supply and fix junction box Single Pole and neutral enclosure compression gland2with connector and clamp for pole mounting with two nos of nut bolt and washers and socket complete of size not less than 12\"x10\"x4\" complete all as specified by Engineer -in- Charge.Note : The rate quoted shall include cost of MS Clamps, bolts, nuts and washers |
| 39 | Shifting,fixing and testing existing street light high performance LED street light fittings/luminaries of any size/capacity complete all as specified and directed. |
| 40 | Supply & Fixing steel tubing GI light grade40 mm dia for cable protection passing under Road/Floor or for fixing on walls complete all as specified and directed. |
| 41 | Supply & Fixing steel tubing GI light grade50 mm dia for cable protection passing under Road/Floor or for fixing on walls complete all as specified and directed. |
| 42 | Supply & Fixing steel tubing GI light grade100 mm dia for cable protection passing under Road/Floor or for fixing on walls complete all as specified and directed. |
| 43 | Supply, installing, testing and commissioning of factory made and tested bus bar chamber outdoor type with canopy made out of 3.15mm CRCA MS sheet and 40x40x5mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type with apron for cable entry closing locking arrangement of size 450mmx450mmx300mm with 4 Nos, 200 Amps copper bus bar including excavation, earth work and platform for the bus bar chamber with PCC 1:4:8 type D-2 with 40mm graded crushed stone, 15cm thick in foundation, brick work in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6 type C-1 using 20mm graded crused stone aggregate on top and grouting bolts etc for bus bar chamber. The platform shall be such that it is of a height 45cm above the nearest road level. |
| 44 | M&L for earthing completewith galvanized mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtr below ground level connected to galvanized iron strip 25x4mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber) 1:2:4 type B-1 using 20mm graded stone aggregate copy shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 funnel wiht wire gauge of 22 gauge (0.68mm) 8 mesh per liner inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm four MS bars @ 80mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2020) and specified including provision of earth wire protected by 40mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, all excavation and earth work & connectiing the earthing to an earthing test point as specified and testing on complete all as specified & directed by Engr-in-Charge. |