| 1 | Dismantling of plain or corrugated steel sheeting any gauge, thicknes, including Naintal or similar pattern roof coverings of any description etc complete all as specified and directed. |
| 2 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed |
| 3 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 5 | S&F roof trusses, framed trussed, purlins, crane gantries, rails and fastening and heavy brackets framing (Beam, tee, angle channel or flat section) incl distance pieces, cleats, nut and bolts conforming to FE-410w (grade 250-E quality A) complete all as specified and directed. |
| 6 | M & L for preparation of new or previously untreated steel and iron surfaces of any description, over 10cm width or girth not other wise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 7 | Demolition of cement or lime concrete (unreinforced) in ground floors and pavings not exc 15 cm thick (below or above ground level ) and removing the debris outside from defence land complete all as specified and directed. |
| 8 | M&L for 75 mm thickPCC 1:3:6 type C-2 (using 40 mm graded stone aggregates) as in sub base/base, path etc completel all as specified and directed. |
| 9 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing fixed over and including 20 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 10 | M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing fixed over and including 10 mm thick rendering in CM 1:4 complete all as specified and directed. |
| 11 | Demolition of brick workor stone boulder masonry built in cement mortar or cement limeincluding all quoins, arches, pillars etc, but excluding ashler facings, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 12 | M&L for brick work with sub class \"B\" bricks straight orcurved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and as directed. |
| 13 | Taking down cement plaster of any description and thickness on walls/ceilings etc including racking out joints, hacking for key, scrubbing down with water etcincluding necessary scaffolding up to four storeys height of bldgs if required and removing of debris out of MoD land complete all as specified and as directed. |
| 14 | M&L for 15mm thick rendering on other than fair faces of brick/ concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed |
| 15 | M&L for 15mm thick rendering on fair faces of brick/ concrete surfaces in CM 1:4finished even and smooth without using extra cement complete all as specified and directed. |
| 16 | M & L for applying three coats of white wash on newly plastered surfaces of walls including preparation of surfaces complete all as specified and as directed. |
| 17 | M&L for preparingof newly plaster surfaces of wall and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/Litre and UV resisitance as per IS 15489:2004, Alkali & fungal resistance dirt resisitance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/10Sqm over and incl priming coat of exterior primer applied @ 0.90 litre/10sqm over new surface complete all as specified and directed. |
| 18 | Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in hard/densesoil complete all as specified and directed. |
| 19 | Returningfilling in, incl spreading, levelling, watering and well ramming in layers n exc 25cm in hard/dense soil complete all as specified and directed . |
| 20 | Removing excavated material (soil) to a distance not exceeding 50M and depositing where directed at a lavel not exceeding 1.5m above the starting point complete all as specified and directed. |
| 21 | M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation and mass concrete complete all as specified and directed. |
| 22 | M&L for 300 mm bore reinforced cement concrete pipes, class NP-2, laid and jointed with collars complete all as specified and as directed. |
| 23 | M & L for PCC 1:2:4 type B-1 using 20mm graded aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed. |
| 24 | M & L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement incl forms, moulds, mi-tred/stopped ends etc. complete all as specified and directed |
| 25 | M&L forPCC 1:3:6 type C-2, (using 40 mm graded stone aggregate) as in surface channels and drains including necessary form work complete all as specified and directed. |
| 26 | Excavation over areas n exc 1.5 m deep and getting out in hard dense soil complete all as specified and as directed. |
| 27 | M&L for walling of random rubble masonary, uncoused,well bonded, bedded and solidly hearted, built in cement mortar 1:4 complete all as specified. |
| 28 | Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface n.exc 40mm to face stones and dressing of face beds and joints as specified of random rubble walling, uncoursed or brought upto courses for Granite or Trap stone complete all as specified and directed. |
| 29 | M&L for PCC 1:2:4, type B-0 (using 12.5mm graded crushed stone aggregate) as in benching, bed plates, copings and the like including necessary formwork, complete all as specified and directed. |
| 30 | M&L for pre cast cement concrete (1:2:4), type B-1 (using 20mm graded crushed stone aggregate)set in cement mortar 1:6 in bond stons for stone masonry and the like including necessary formwork, complete all as specified and directed. |
| 31 | M&L for Flush pointing in cement mortar 1:4 to random rubble masonry ,uncoursed or brought upto courses complete all as specified and as directed. |
| 32 | M&L for boulder filling dry hand packed tightly as in back of wall complete all as specified and as directed. |
| 33 | S & F 110 mm bore PVC (SWR) pipes single socket in any length as in weep holes etc complete all as specified and as directed. |
| 34 | M&L for precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 100 mm thickness, M-50 Grade with grey cement and no pigment including preperation of formation bed over 25 mm thick sand cusion and pointed in colour cement mortar 1:3 complete all as specified and directed. |
| 35 | M&L for hardcore of broken stones gauge not exceeding63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 36 | M&L for chequered cement concrete tiles 30 cm X 30 cm X 22-25 mm thick, set, jointed and pointed in neat cement slurry with grey cement and pigmentsin floors laid over and including 15mm screed bed in CM 1:6 for laying floor finishes/ tiles complete all as specified and directed. |
| 37 | M&L Single pointed air termination Copper rod , 12 mm dia , 300 mm long, complete all as specified and as directed. |
| 38 | M&L for Earthing complete with copper earth plate electrode 600x600×3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to copper earth lead strip 20x3mmby means of bolts, nuts, check nuts and washers of copper / brass all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed. (for Lighting protection system)Note : 1. Upto 7.5 Mtr copper strip included in quoted rate for earthing. Additional copper strip will be measured and paid under respective item.2. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. |
| 39 | Supply and fixing of earth continuity conductor or main earthing leadfixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25 x3mm aluminium strip with saddles / insulators at 50cm distance, complete all as specified and directed. |
| 40 | Supply and fixing of earth continuity conductor or main earthing leadfixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x6mm GI strip for grid with saddles / insulators at 50cm distance, complete all as specified and directed. |
| 41 | M&L for Test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm, drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws, complete all as specified and as directed. |
| 42 | S&F galvanised iron tubing, medium grade, 40 mm bore, for lighting protection rod fixing on roof with plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate, complete all as specified and directed. Note:- PCC shall be measured and paid seperately under respective item. |
| 43 | M&L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) in foundation of pipe supports/platform etc. including necessary form work complete all as specified and as directed. |
| 44 | S&F Rolled mild steel Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lenghts i.e. within 20mm of the length indicated) GDE Fe 410-0 W (Gde E-250) quality \"B\" complete all as specified and directed. |