| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for Repair of cable by getting out the any type soil,protection cable cover/bricks/checkerd tile/interlocking tiles/Any other service lines like HT/LT Cable/ Water lines etcand sand kept itin stack, afterlaying of cable all damaged / removed path/ road etc shall be repaired as per existingcondition eplacement of cable etc cost ofmaking good to disturbed surface / services including material required to make it as existing shall be deemed to included in quoted rate complete all as specified and directed. |
| 2 | Returning, filling in including spreading, levelling, watering and well ramming excavated soilin layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested,poles, stays , struts have been erected and tested all as specified and directed. |
| 3 | Removing excavated surplus soil (Soft/hard soil) obtained from excavation to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 4 | Supply and laying sand cushioning for cable protection in trenches 8 cm before laying cable and 15 cm deep over the cable complete all as specified and directed. |
| 5 | Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1, flat with peak, size 250mm x 150mm x 40mm complete all as specified and directed. |
| 6 | Material and labour for Taking outany type light fittings complete all as specified and directed. |
| 7 | M&L for taking outLT cable,after taking electrical shutdown complete f cableXLPE Insulated , galvanized steel strip or wire armoured,heavy dutyLT electric power cables 1100 Volts grade with stranded aluminium conductor of size 4 Core x 16 Sqmm complete all as specifieda and directed. |
| 8 | M&L for taking outLT cable,after taking electrical shutdown complete f cableXLPE Insulated , galvanized steel strip or wire armoured,heavy dutyLT electric power cables 1100 Volts grade with stranded aluminium conductor of size 4 Core x 10 Sqmm complete all as specifieda and directed. |
| 9 | M&L for taking outLT cable,after taking electrical shutdown complete f cableXLPE Insulated , galvanized steel strip or wire armoured,heavy dutyLT electric power cables 1100 Volts grade with stranded aluminium conductor of size 2 Core x 10 Sqmm complete all as specifieda and directed. |
| 10 | M&L for taking outLT cable,after taking electrical shutdown complete f cableXLPE Insulated , galvanized steel strip or wire armoured,heavy dutyLT electric power cables 1100 Volts grade with stranded aluminium conductor of size 2 Core x 6 Sqmm complete all as specifieda and directed. |
| 11 | M&L for taking outLT cable,after taking electrical shutdown complete f cableXLPE Insulated , galvanized steel strip or wire armoured,heavy dutyLT electric power cables 1100 Volts grade with stranded aluminium conductor of size 2 Core x 4 Sqmm complete all as specifieda and directed. |
| 12 | M&L for repair/ replacement of LT cable, laying and testingof cableXLPE Insulated , galvanized steel strip or wire armoured,heavy dutyLT electric power cables 1100 Volts grade with stranded aluminium conductor of size 4 Core x 16 Sqmm complete all as specified and directe. |
| 13 | M&L for repair/ replacement of LT cable, laying and testingof cableXLPE Insulated , galvanized steel strip or wire armoured,heavy dutyLT electric power cables 1100 Volts grade with stranded aluminium conductor of size 4 Core x 10 Sqmm complete all as specified and directe. |
| 14 | M&L for repair/ replacement of LT cable, laying and testingof cableXLPE Insulated , galvanized steel strip or wire armoured,heavy dutyLT electric power cables 1100 Volts grade with stranded aluminium conductor of size 2 Core x 10 Sqmm complete all as specified and directe. |
| 15 | M&L for repair/ replacement of LT cable, laying and testingof cableXLPE Insulated , galvanized steel strip or wire armoured,heavy dutyLT electric power cables 1100 Volts grade with stranded aluminium conductor of size 2 Core x 6 Sqmm complete all as specified and directe. |
| 16 | M&L for repair/ replacement of LT cable, laying and testingof cableXLPE Insulated , galvanized steel strip or wire armoured,heavy dutyLT electric power cables 1100 Volts grade with stranded aluminium conductor of size 2 Core x 4 Sqmm complete all as specified and directed. |
| 17 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to using galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed by Engr-in-charge |
| 18 | M&L for horizontal drilling, in any type of soil, using trenchless technology suitable for insertion of GI pipe /Medium Grade PVCandLT cablesalong the pipe complete all as specified and directed of 50 mm dia of GI Pipe complete all as specified and directed. |
| 19 | Material and Labour for Double Compression cable Gland weatherproof suitable for cable 10 to16 Sqmm complete all as specified and directed. |
| 20 | S&F GI tubing light grade galvanised /Medium Grade PVC with all fittings like Bend Elbow Tee etc& fixed complete wall/pole for 40mm bore complete all as specified and directed. |
| 21 | S&F GI tubing light grade galvanised/Medium Grade PVC with all fittings & fixed complete wall/pole for 50 mm bore complete all as specified and directed. |
| 22 | Supply, installation, commissioning and testing, in repair, Time switch panel , LT (415 Volts, 50 Hz , 3-phase, 4 wire supply),CPRI approved, plinth mounted, factory made, outdoor type of size (1500 x600 x 1000) mm weather and vermin proof (Protection Class IP-54) made out of 50mm x 50mm x 5mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet powder coated with front & back hinged opening, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint (First Quality) over a coat of red oxide primer, grouting panel through angle iron, 0.2 mtr in ground and 0.5 mtr over the ground including excavation & earth work in any type of soil and PCC (1:3:6) type C-2 using 40mm graded stone aggregate complete comprising of the followings:-(a) Incoming supply:- (i) Mains incomer, 63 A, 25 kA, 4-pole MCCB with adjustable thermal-magnetic release - 01 No(ii) Indicating lamp Neon type for R-Y-B - 3 Nos (vi)Extended rotary handle & spreader terminals for above MCCB-01 Nos (vii) 6 A TP MCB-01 NosMAIN BUSBAR SIZE- 25 X 10 mm. EC grade aluminium busbarsMAIN BUSBAR SIZE (For neutral)-25 X10 mm. EC grade aluminium busbarsEARTHING BUS 25 x 10 mm. EC grade aluminium busbarsPANEL MOUNTING-Floor mountedCABLE ENTRY-Bottom for both incoming and outgoingPANEL FABRICATION-From 11G CRCA sheet steelFINISHING-Powder coating (min. 80 micron) after 7-tank process to shade RAL-7035PANEL DIMENSIONS- App. 750 mm. (H) X 700 mm. (W) X 450 mm. (D) |
| 23 | Supply, installation, commissioning and testing, in repair, Junction Box , LT (415 Volts, 50 Hz , 3-phase, 4 wire supply),CPRI approved, plinth mounted, factory made, Indoor type of size (1200 x 900 x 600 ) mm weather and vermin proof (Protection Class IP-54) made out of 50mm x 50mm x 5mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet powder coated with front & back hinged opening, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint (First Quality) over a coat of red oxide primer, grouting panel through angle iron, 0.2 mtr in ground and 0.5 mtr over the ground including excavation & earth work in any type of soil and PCC (1:3:6) type C-2 using 40mm graded stone aggregate complete comprising of the followings:-(a) Incoming supply:- (i)Changeover Switch 250 Amp .with Mains incomer, 250 A, 25 kA, 4-pole MCCB with adjustable thermal-magnetic release - 01 No(ii) Indicating lamp Neon type for R-Y-B - 3 Nos (vi)Extended rotary handle & spreader terminals for above MCCB-01 Nos (vii) 6 A TP MCB-01 Nos MAIN BUSBAR SIZE- 40 X 10 mm. EC grade aluminium busbarsMAIN BUSBAR SIZE (For neutral)-40 X10 mm. EC grade aluminium busbarsEARTHING BUS 40x5 mm. EC grade aluminium busbarsPANEL MOUNTING-Floor mountedCABLE ENTRY-Bottom for both incoming and outgoingPANEL FABRICATION-From CRCA sheet steelFINISHING-Powder coating (min. 80 micron) after 7-tank process to shade RAL-7035PANEL DIMENSIONS- App. 1500 mm. (H) X 700 mm. (W) X 450 mm. (D) |
| 24 | M&L for Repair of CableBy Insertion of Straight through Joint Cold Shrink Typefor LT Cable 10 Sq mm 2 Corewith all accessories complete all as specified and directed. |
| 25 | S&F, aluminum / Tinned lugs for cable size 2.5 to 16 sqmm complete all as specified and directed. |
| 26 | M/L for PCC (1:4:8) type D-2 using 40mm graded aggregate as in foundation/surface repair for pole / Platformetc complete all as specified and directed. |
| 27 | M/L for PCC (1:3:6) typeC-1 using 20mm graded aggregate as in foundation/surface repair for pole / Platformetc complete all as specified and directed. |
| 28 | S&F PVC insulated and PVC sheathed copper conductor cable of size 1.5 Sqmm, 3 core, 1100 volts grade, multistranded, passing throuth pipe, on pole/wall from juntion box to street light fitting complete all as specified and directed. |
| 29 | Supply and fixing LED Out doorunder Water Fountain Light Fittings complete IP-68, 220 Volt Ac50 Hzof RGBColour 36 Watt (12 x 3 ) complete in all respect all as directed. |
| 30 | Supply and fixing Tricolour LED Bollard / Column LightFittings of 1 mtr Height suitable for 220 volt Ac, 50 Hz Supply complete in all Respect all as directed. |
| 31 | Supply and fixing LED Out door land scape ProjectionFlood Light Fitting complete IP-54, 220 Volt Ac50 Hzof RGBColour 36/45 Watt (12/15 x 3 ) complete in all respect all as directed. |
| 32 | Supply and fixing LED Out door land scape ProjectionFlood Light Fitting complete IP-54, 220 Volt Ac50 Hzof RGBColour 60 Watt (20 x 3 ) complete in all respect all as directed. |
| 33 | Supply and fixing TricolourColumn LEDLightFittings of 2 mtr Height suitable for 220 volt Ac 50 Hz Supply complete all as specified and directed. |
| 34 | Supply and fixing LED StripLightFittings of 10 mtrRollwith Driver of Red,Orange,Green., Blue, Voilet,White, Golden , Silver, Pink Colour suitable for 220 volt Ac 50 Hz Supply complete all as specified and directed. |
| 35 | Supply and fixing LED Out door land scape ProjectionFlood Light Fitting complete IP-54, 220 Volt Ac50 Hzof120 Watt complete all as specified and directed. |
| 36 | Supply and Fixing 1 HP Single Phase, 220 volt Ac 50 HzSubmersible motor with Pump complete including starter and control panel with lighting controller |
| 37 | Supply and fixingLED Bollard LightFittings of9 watt suitable for 220 volt Ac 50 Hz Supplycomplete all as specified and directed. |
| 38 | Supply, installation,Lowering andtesting of Submersible motor andpump set60 HP, electric driven415 volt Ac 50 Hz with discharge capacity min 60000 Ltr Per Hour, 12 stage , 170 mtr head Pump and Motor Dia Shlould not be more than 150 mm dia. Capacity will beChanged as per Technical Graph of Manufacturer,before purchase of material all technical data of the submersible pump and motor should be approved by the Accepting officer, Electrical logging with videography of borewell before lowering of new submersible pump including report shall be submitted before lowering the submersible pump and after go-ahead from Engineer-in-Charge. |
| 39 | Supply, installation,Lowering andtesting of Submersible motor andpump set60 HP, electric driven415 volt Ac 50 Hz with discharge capacity min 60000 Ltr Per Hour, 12/ 15stage , 170 mtr head Pump and Motor Dia Should not bemore than 100 mm Capacity will beChanged as per Technical Graph of Manufacturer,before purchase of material all technical data of the submersible pump and motor should be approved by the Accepting officer, Electrical logging with videography of borewell before lowering of new submersible pump including report shall be submitted before lowering the submersible pump and after go-ahead from Engineer-in-Charge. |
| 40 | Supply and lowering 3 mtrLongwith wire locked , Socketthreadedcomplete Column Pipe Super Heavyduty to match the Submersible pump pressuremin 25 Kg/ Sq cm , U PVCof Size 4\" with thick and thin construction technique will be used for manufacturing of pipes with specially designedthread, multiseal rings Bi-axialorientationtechnique will be usedduring pipe extrusion ,which gives higher drop impact and notch impact strength of pipe. Pipe shall be Provided withExpander, Reducingof SSIncluding Two set of Jigs Inner andOuter lowering Fixtureetccostt of lifting lowering tackesand all accessories and mounting shall bedeemed to included in quoted rate ofmake :- ashirvad / Supreme /Finolex .before purchase of material all technical data of the Column pipe 3 mtr long should be approved by the Accepting officer, incl all technical details complete all as specified and directed. |
| 41 | Supply and lowering 3 mtrLongwith wire locked , Socketthreadedcomplete Column Pipe Super Heavyduty to match the Submersible pump pressuremin 25 Kg/ Sq cm , U PVCof Size 5\" with thick and thin construction technique will be used for manufacturing of pipes with specially designedthread, multiseal rings Bi-axialorientationtechnique will be usedduring pipe extrusion ,which gives higher drop impact and notch impact strength of pipe. Pipe shall be Provided withExpander, Reducingof SSIncluding Two set of Jigs Inner andOuter lowering Fixtureetccostt of lifting lowering tackesand all accessories and mounting shall bedeemed to included in quoted rate ofmake :- ashirvad / Supreme /Finolex .before purchase of material all technical data of the Column pipe 3 mtr long should be approved by the Accepting officer, incl all technical details complete all as specified and directed. |
| 42 | M&L for Lifting/ Lowering of Submersible pump setwith column pipe complete includingall special tools and tackles for lifting / loweringon Borewells complete all as specified and directed. |
| 43 | Supply, connectionjointingwith water proofingtape includingtiestrap of submersible copper cable of size 35 Sqmm3 core 1100 volt grade complete all as specified and directed. |
| 44 | M&L for allAccessories and FittingsLike Reducer, Inlarger, Threaded flangedconnection nearPump Mouth and Discharge line complete all as specified and directed. |