| 1 | SCHEDULE ‘A’ PART-I (SCHEDULE OF ITEMS) |
| 2 | M&L for Wiring for light point/ fan point/ exhaust fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in conceled/ surface / recessed PVC conduit or Caping-N-Casingwith and includingmodular switch, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required all as specified and directed(Group C) |
| 3 | M&L for Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduitor caping-N-casing including2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required |
| 4 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 5 | Supplying and fixing of 5/6 amps modular switch |
| 6 | 2 way 5/6 Amps modular Switch |
| 7 | 15/16 Amp modular switch |
| 8 | 3/5 Pin 5/6 Amp modular socket out let |
| 9 | 6 Pin 15/16 Amp modular socket outlet. |
| 10 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 11 | Supplying and fixing fowlloing size/ modules GI box along with modules base & cover plate for modular swithes in recessetc as required. (a) 1 or 2 module (75mmx75mm) |
| 12 | (b) 3 modules (100mmx75mm) |
| 13 | (c) 4 modules (125mmx75mm) |
| 14 | (d) 6 modules (200mmx75mm) |
| 15 | (e) 8 modules (125mmx125mm) |
| 16 | (e) 12 modules (200mmx150mm) |
| 17 | Supplying and fixing 3 pin 5amp ceiling rose on the existing junction box/ etc as requied . |
| 18 | Earthing with GI earth plate 600mmx600mmx3mm thick including accessorise and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc with charcoal/ coke and salt as required. |
| 19 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required |
| 20 | Supplying and fixingPVCbatten / angle holder incl connection as reqd complete all as specified and directed |
| 21 | Supply only Exhaust Fan metal body 300mm sweep heavy duty 900RPM complete all as directed by Engr-in-Charge. |
| 22 | Fixing onlyExhaustfan of any sweep/typeincuding making all electric connections complete all as specified anddirected. |
| 23 | Supplying and fixing of 4 way (4 + 12), double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required. |
| 24 | S&F in replacement of MCB \"C\" Curve type, 10 kA, 5 to 32 Amp, Single Pole with over load and short circuit protection complete all as directed. |
| 25 | Supplying and fixing 63 Amps rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 26 | Wiring for circuit/ submain wiring alongwith earth wire with the 2x1.5 sq mm+1x1.5 sq mm earth wire of FRLS PVC insulated copper conductor, single core cable in casing caping as requed.. |
| 27 | Wiring for circuit/ submain wiring alongwith earth wire with the 2x2.5 sq mm+1x2.5 sq mm earth wire of FRLS PVC insulated copper conductor, single core cable in casing caping as required. |
| 28 | Wiring for circuit/ submain wiring along earth wire with the 2x6 sq mm+1x6 sq mm earth wire of FRLS PVC insulated copper conductor, single core cable in casing caping as required. |
| 29 | Supply only Edgepro Surface Round of 18W, Elegantly designed sleek surface mounted pressure die-cast aluminium luminaire in powder coated white finish in square profile with optimized heat sink for efficient heat dissipation and independent electronic LED driver(WW) |
| 30 | Supply only LED , Tube light fitting 20 W, 6500K Intenso AX LED batten aluminium profile self ballasted surface mounted LED Batten extruded aluminium body with PC diffuser in unic shape. >180º wide light distribution. soft glare free light complete accessories. |
| 31 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. |
| 32 | Repair and replacement of Street light 50 Watts white/warm White as per site requirement |
| 33 | Fixing onlypre-wired light fittings of LED of 18W flurecent/compact fluoverscent fittingwith all accessorieson ceiling/wall including connetion with 1.5 sqmm FRLS PVC insulated, copper inductor, single core cable and earthing etc as required all as specified and directed. |
| 34 | Supply only of LT UG Cable PVC Shethed XLPE Cable 70 Sqmm 3.5 Core |
| 35 | Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required |
| 36 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size direct in Open/, Wall/ ground including excavation, sand cushioning, protective covering and refilling the trench above 35 Sqmmupto 95Sqmm complete all as specified and Directed by Engr-In-Charge.Note: As Per Site Condition laying of Cable Open/Wall/Trench |
| 37 | M&L for 2D LED bakelite glow sign board made of acrylic/ACBsheetframing with LED lights (White/Warm white) suitable capacity ofcontrol driver, power connection copper cable 1.5Sqmm x 2 coreincluding GI frame with angle iron stand as per site requirement complet all as specified and directed by Engr-In-Charge. |
| 38 | Supply & fix Bus bar Panel, Size:0.8x0.4x0.4 Mtr,Kisokoutdoor type, CPRI type tested, LT 440 Volts, 50 Hz , 3 Phase4 wire supply , floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 3.14 mm thick MS Sheet CRCA on angle iron 30X30X4mm frame of size suitable to incorporate following accessories with both side opening doors,locking arrangementpowder coated internally and externally, shall have channel base of appropriate size and mounted on PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 typeC-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed by the Engr -in - charge including earth work complete comprising of Bus bar chamber comprising 4 Nos Aluminium strip bus bars PVC insulated made of aluminium strip of size suitable for 250A current & 4 ways. PVC sheathed with colour coding incl 200 Amps 4 Pole MCCB and all as specified and directed by Engr-In-Charge. |
| 39 | Dismantling of existing Refrigeration system installed at site complete with all connecting accossories all as specified and as directed by Enge-in-Charge. |
| 40 | Supply, Installation, testing and commissioning of Refrigeration system inside the PUF Room of size 10 ft x 10 ft x 8 ft for maintaining a stable temperature 2 degree centigrade to 8 degree centigrade including the outdoor condensing unit with indoor evaporator unit with minimum 6 mtr of copper pipe with each unit of capacity 4 KW control panel for operation with R407 Refrigerant complete all as specified and as directed. |
| 41 | Supply, Installation, testing and commissioning of Servo Stablizer of capacity 6 KVA, 3 phase, Air Cooled of working range 300V-480V complete all as specified and as directed. |
| 42 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 43 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 44 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 45 | SCHEDULE ‘A’ PART-II (SCHEDULE OF CREDIT) |
| 46 | Old U/S point wiring including switches (Rate should be quoted Rs. 10.00 per point or more) |
| 47 | Old unserviceable earthing materialsof any size/capacity (Rate should be quotedRs. 65.00 each or more) |
| 48 | Old unserviceable Distrubution Board of any size/capacity (Rate should be quoted Rs. 25.00 each or more) |
| 49 | Old unserviceableMCBsof any size/capacity(Rate should be quoted Rs. 5.00 each or more) |
| 50 | Old unserviceable light fittingof any size/capacity (Rate should be quotedRs. 5.00 each or more) |
| 51 | Old unserviceable Sub Main wiring of any size/capacity (Rate should be quotedRs. 8.00 per RM or more) |
| 52 | Old unsv street light/flood lights of any type(Rate should be quoted Rs. 50.00 each or more) |
| 53 | Old unsv UG cable of any size and capcity(Rate should be quoted Rs. 15.00 RM or more) |