Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | M&L for complete removal of existing waterproofing treatment (APP and tiles) of any description and in any position, including cleaning, wire brushing, washing and watering, as directed by Engineer-in-Charge, complete all as specified and directed. |
| 2 | Demolition of plain concrete of any description and in any position, not otherwise specifically provided for, complete all as specified and directed by Engr-in-Charge. |
| 3 | M&L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in roof/chajja padding for maintaining roof/chajja slope, complete all as specified and directed by EIC. |
| 4 | Supply only ready-mix micro-concrete, to be mixed with PCC as directed, complete all as specified and directed by EIC. |
| 5 | M&L for rendering 15 mm thick pre-polymer modified ready-mixed cement-based plaster over roof top to maintain proper slope.Plaster shall have minimum cement:sand composition of 1:4, using fully treated dry, well-graded natural sand conforming to IS-383, having low rebound properties, low water demand, and mechanically mixed with water in metal tray to achieve proper workability and consistency as per manufacturer’s specification.Applied over concrete/brick masonry surfaces; richer mix shall be used for forming corners where required. Complete all as specified and directed. |
| 6 | Supply only integral waterproofing compound (3% by weight of cement) complete all as specified and directed. |
| 7 | M&L for preparing plastered surfaces of roof slabs/chhajjas, removing dust by brooming and washing, and applying one coat of approved bituminous primer @ 0.20 kg/sqm, complete all as specified and directed by EIC. |
| 8 | M&L for APP-based polymeric membrane waterproofing treatment, minimum 3 kg/sqm, minimum 3 mm thick, reinforced with polyester non-woven fabric (minimum 150 gsm), laid over primed surface by torch application, complete all as specified and directed by EIC.Notes:(a) Side overlaps shall be minimum 75 mm and end laps minimum 100 mm. All joints shall be sealed as per manufacturer’s instructions.(b) The membrane shall be inserted into the wall at a height of 300 mm by cutting a groove and finishing with membrane flashing.(c) Quoted rate shall include disconnection and refixing of existing AC units including necessary fittings if damaged. |
| 9 | M&L for cement concrete tiles 25 cm × 25 cm × 22 mm, machine-pressed (grey cement, no pigments), set, jointed and pointed in neat cement slurry, including cutting and polishing; and including 15 mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 10 | M&L for preparation of roof/walls and applying two coats of chemical waterproofing treatment (Raincoat of Pidilite or equivalent) on walls, chajjas, terraces and parapet wall junctions such as Flexcoat, Beckcoat Exshield or equivalent, including filling cracks with Crack-X of Pidilite or equivalent as per manufacturer’s instructions, complete all as specified and directed. |
| 11 | M&L forDisconnecting existingtanks of capacity exc 1000 lit and n exc 2000 lit capacity, setting aside (orloweringif required)forrepairs, cleaning, etc. andhoisting if requiredreconnecting and re-fixing inposition complete. |
| 12 | Dismantling floor, hearth or wall tiling, including cement mortar bedding but not backing, removing serviceable tiles to store and disposing of rubbish off the premises, complete all as specified and directed. |
| 13 | M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, with and including 15 mm thick screed bed in CM 1:4, complete all as specified and directed |
| 14 | M&L for coloured glazed ceramic tiles in vertical surfaces, area of each tile exceeding 0.18 sqm, set and jointed in neat cement paste and pointed in coloured cement to match the shade of the tiles, with and including 10 mm thick backing coat in CM 1:4 and triangular filleting at skirting junction, complete all as specified and |
| 15 | M&L for premium quality vitrified ceramic tiles 9–10 mm thick (square/rectangular), polished, area of each tile exceeding 0.36 sqm, set and jointed in neat cement slurry and pointed in white/coloured cement to match, with and including 20 mm thick screed bed or bedding layer in CM 1:4, complete all as specified and directed.Note: Sample of tile shall be selected by Engr-in-Charge from latest catalogue. |
| 16 | Ditto_ as per Item No. 15.00 above but in skirting/vertical surfaces, with 10 mm thick backing coat in CM 1:4, complete all as specified and directed. |
| 17 | M&L for applying a tack coat of industrial bitumen 85/25 @ 1.2 kg per sqm, including cleaning the surface, complete all as specified and directed. |
| 18 | M&L for nominal mix PCC type E2 (1:5:10,) using graded stone aggregate (lean concrete) as in foundations/bed layers, complete all as specified and directed. |
| 19 | M&L for PCC 1:3:6 type C-2, 100 mm thick as in sub-base for sunken slab/floor, mixed with waterproofing compound (WPC) @ 3% by weight of cement, finished even and smooth (without using extra cement), complete all as specified and directed.Note: WPC shall be measured and paid separat |
| 20 | M&L for 20 mm thick cement screed in CM 1:3, mixed with liquid waterproofing compound FOSROC’s Complast 421 IC @ 130 ml per bag of cement, including applying a bonding coat of FOSROC NitoBond AR cement slurry for sunken slab/floor, complete all as specified and directed.Note: Liquid waterproofing compound shall be measured and paid separately. |
| 21 | M&L for chipping and removing concrete carefully by low-impact hammer/breaker, without damaging structural members, removing loose concrete, cleaning the surface and disposing of debris outside the premises, complete all as directed by Engr-in-Charge.Note: Hard concrete shall not be removed by force. |
| 22 | M&L for cleaning existing reinforcement with wire/rotary wire brush, removing loose rust/dirt, applying two coats of alkaline rust-converting primer FEOVERT (ASTM-B-117) on reinforcement, with minimum 6 hours interval between coats, including wire-brushing, removing loose rust spalls, and applying protective coating IPNET-RB, complete all as specified and directed. |
| 23 | M&L for applying structural grade EPIBOND-21-LP prior to application of any type of mortar plaster, conforming to ASTM-C-882-91 (Arizona Slant Shear Test) to ensure proper bond between old and new concrete, complete all as specified and directed. |
| 24 | Taking down cement plaster or cement lime plaster on brick or stone walls, including raking out joints, hacking for key and scrubbing down with water, complete all as specified and directed. |
| 25 | M&L for rendering 15 mm thick on fair faces of brickwork or concrete surfaces in CM 1:6, finished even and smooth (without using extra cement), including erection and dismantling of scaffolding for heights up to 1 to 4 storeys, complete all as specified and directed. |
| 26 | M&L for rendering 10 mm thick in CM 1:3 on ceiling, finished fair and even.(The ceiling height shall be included up to the top slab of the building.)Complete all as specified and directed. |
| 27 | M&L for rendering 15mm thick in cement mortar (1:4) on external wall surfaces, finished even and smooth without using extra cement, including WPC @ 3% by weight of cement (WPC measured and paid separately), and including erection and dismantling of scaffolding for work up to 1 to 4 storeys, complete all as specified and directed. |
| 28 | M&L for rendering 15mm thick using ready-mixed cement-based plaster, minimum cement:sand ratio 1:4, using fully treated dry, well-graded natural sand conforming to IS-383, having low rebound loss and low water demand; mixed mechanically with water to obtain required workability and applied over masonry/concrete surfaces; including scaffolding for work up to 1 to 4 storeys, complete all as specified and directed. |
| 29 | M&L for preparation of newly plastered wall surfaces and applying two coats of acrylic antifungal exterior-grade paint @ 1.67 litre/10 sqm over and including one coat of exterior primer @ 2.20 kg/10 sqm, including erection and dismantling of scaffolding for work up to 1 to 4 storeys, complete all as specified and directed. |
| 30 | M&L for preparing new plastered wall surfaces and applying two coats of oil-bound distemper over and including one coat of alkali-resistant primer, including necessary scaffolding, complete all as specified and directed. |
| 31 | M&L for preparation of new plastered ceiling surfaces and applying three coats of whitewash including necessary scaffolding, complete all as specified and directed by Engineer-in-Charge. |
| 32 | M&L for applying 3mm thick wall care putty over plastered wall surfaces including sanding and cleaning to obtain an even and smooth surface prior to painting, complete all as specified and directed. |
| 33 | M&L for preparation of old decorated wall surfaces and applying one coat of acrylic antifungal exterior-grade paint @ 1.67 litre/10 sqm over and including primer @ 2.20 kg/10 sqm, including erection and dismantling of scaffolding for work up to 1 to 4 storeys, complete all as specified and directed. |
| 34 | M&L for preparation of old decorated wall surfaces and applying two coats of acrylic antifungal exterior-grade paint @ 1.67 litre/10 sqm over and including primer @ 2.20 kg/10 sqm, including erection and dismantling of scaffolding for work up to 1 to 4 storeys, complete all as specified and directed. |
| 35 | M&L for preparation of old ceiling surfaces and applying one coat of oil-bound distemper including necessary scaffolding, complete all as specified and directed by Engineer-in-Charge. |
| 36 | M&L for preparation of old wall surfaces of any description and applying one coat of oil-bound distemper including necessary scaffolding up to mezzanine floor level, complete all as specified and directed. |
| 37 | M&L for drilling 12mm dia holes, 75mm deep at 0.6m c/c at junctions of beams and columns for inserting/pouring resin-latex polymer and cement slurry by pressure grouting for beams, columns and slabs, and sealing holes with CM (1:3), complete all as specified and directed by Engineer-in-Charge. |
| 38 | Material & labour for jacketing to columns/beams/other RCC members using micro-concrete (Molith-MC or equivalent), including required lifts, shuttering, drilling for shear anchors, fixing deficient reinforcement, cleaning, and applying micro-concrete as per manufacturer’s specifications; rates to include formwork and micro-concrete. (Reinforcement measured and paid separately). |
| 39 | M&L for TMT (CRS) mild steel bars 10mm dia and over, cut to length, bent to required shape including cranking, spiral bending for hooping, hooking ends and binding with annealed mild steel wire of dia not less than 0.9mm, or securing with clips, conforming to Fe-410-S or Fe-410-0, complete all as specified. |
| 40 | All as per Item No. 39 above but for TMT bars 6 to 8mm dia used as stirrups. |
| 41 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar works, vertical or inclined, to obtain a rough-finished flat surface of concrete, complete all as specified and directed. |
| 42 | Formwork to sides of pillars, posts, struts and columns, rough-finished surface of concrete of square, rectangular or polygonal sections, complete all as specified and directed. |
| 43 | Dismantling battens for tiles, shingles, or similar roofing elements of any size, including removal of tilting fillets, complete all as specified and directed by Engineer-in-Charge. |
| 44 | M&L for Mangalore pattern roofing tiles, interlocking at side joints, laid dry over battens, complete all as specified and directed. |
| 45 | M&L for ridge or hip tiles to suit the Mangalore pattern of roofing tiles, bedded and jointed in lime mortar (1:3) or cement mortar (1:6), complete all as specified and directed. |
| 46 | Dismantling stone slabs or tiles of any description or thickness, laid, bedded and pointed in any mortar in floors, aprons or similar areas, complete all as specified and directed. |
| 47 | M&L for 20 mm thick machine cut mirror polished granite (of any type), table rubbed and polished, used in steps, jambs, pillars, window cills, cooking platforms, working tables, etc., laid over 20 mm thick screed bed in CM (1:4), including pointing in white cement (1:2) with marble dust and pigments to match the shade of granite, complete all as specified and directed. |
| 48 | M&L for 20 mm thick machine cut mirror polished granite in skirting/dado, laid over 10 mm thick backing coat in CM (1:3), jointed with grey cement slurry and pointed with white cement with pigment to match granite shade, including grinding and polishing, complete all as specified and directed (colour of granite as approved by GE/Engr-in-Charge). |
| 49 | M&L for beewax polishing on marble, granite, Kota stone, stone work or mosaic tiles wherever required to obtain a high-gloss finish, complete all as specified and directed. |
| 50 | M&L for 20–22 mm thick machine-cut Kota stone slab, used in floors, steps, landings etc., set and jointed in neat cement slurry and pointed in coloured cement to match the slab shade, including cutting, rubbing, polishing and 20 mm thick screed bed in CM (1:4), complete all as specified and directed. |
| 51 | Dismantling wall and ceiling boards (fibre, pulp, insulation), false ceiling, wall panelling and partition boards including bonded wool/blanket slab and aluminium grid framework, complete all as specified and directed. |
| 52 | M&L for anodised aluminium snap grid framework for false ceiling of grid size 605 × 605 mm with 2 mm dia G.I. hangers (up to 1200 mm length), fixed to roof slab using ceiling cleats made from G.I. flat 40 × 3 mm, 60 mm long, with expansion holdfasts 12.5 mm dia × 40 mm long, including cement board fixing for 600 × 600 mm ceiling panels, complete all as specified and directed (Make: Everest or equivalent as approved by GE). |
| 53 | Taking down chowkats or frames exceeding 1.5 sqm but not exceeding 4 sqm each, with shutters (without removing shutters from the frame), complete all as specified and directed. |
| 54 | Taking down chowkats or frames not exceeding 1.5 sqm each, with shutters (without removing shutters from the frame), complete all as specified and directed. |
| 55 | Supply & fixing in repairs powder coated aluminiumsections for partitions, windows, ventilators and doors including fabrication of frame/shutters and fixing to walls/floors with necessary lugs, cleats etc including all accessories such asglazing clips, handles, tower bolts, rollers rubber beadings for fixing glass panes in frame including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required complete all as specifiedNote: - (i) Glass panes will be measured & paid separately. (ii)The rate quoted shall be inclusive of neoprene beading, glazing clips, screws, etc. as requiredbut shall not be measured for arriving of weight.(iii) Minimum thickness of powder coating shall be 25 micron. (iv) The rate shall be inclusive of the locking arrangement including complete packing with silicon gel around contacting surface of aluminium work with matching existing area.(v)The size of aluminium sections shall be as perHQ CE(N) MZ TD drawing No TD/2021/01 to 05 |
| 56 | S&F in repairs 4 mm thick frosted glass sheet of ordinary quality, glazed in square panes not exceeding 0.5 sqm each, fixed to aluminium windows/ventilators, complete all as specified and directed. |
| 57 | S&F in repairs 4 mm thick frosted glass sheet of ordinary quality, glazed in square panes exceeding 0.5 sqm each, fixed to aluminium windows/ventilators, complete all as specified and directed. |
| 58 | M&L for 4 mm thick plain glass sheets of ordinary quality, in square panes not exceeding 0.5 sqm each, fixed with rubber beading to aluminium windows/doors, complete all as specified and directed. |
| 59 | M&L for 4 mm thick plain glass sheets of ordinary quality, in square panes exceeding 0.5 sqm each, fixed with rubber beading to aluminium windows/doors, complete all as specified and directed. |
| 60 | S&F in repairs anodised aluminium grill (Deco Grill DG–103, 7.5 mm thick,fixed with suitable “F” section, fabricated and riveted to aluminium windows, complete all as specified and directed by Engr-in-Charge. |
| 61 | S&F in repairs 12 mm thick pre-laminated Medium Density Fibre Board (MDF), both sides decorative interior-grade lamination, fixed in aluminium/wooden framework, complete all as specified and directed. |
| 62 | S&F stainless steel wire cloth with 0.36 mm nominal wire diameter and average aperture width of 1.4 mm, complete all as specified and directed. |
| 63 | S&F in repairs 4 mm thick bakelite sheet with decorative laminated finish on both sides, complete all as specified and directed. |
| 64 | M&L for applying one coat of Hydrolock waterproofing compound by brush, without dilution, over the finished surface, complete all as specified and as directed by the Engr-in-Charge. |
| 65 | Taking down PVC waste and rainwater pipes of any size or pattern, including removal of all fittings such as heads, shoes, bends, swan-necks, etc., complete all as specified and as directed. |
| 66 | Supply & Fixing in repairs 160mm bore PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls with dash through fastners and rain water bracketsuitable for 110mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified. |
| 67 | S&F 160mm dia bore PVC (SWR) bends any radius complete all as specified and as directed |
| 68 | Supply & Fixing 110mm bore PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls with dash through fastners and rain water bracketsuitable for 110mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified. |
| 69 | Supply & Fixing 75 mm bore PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls with dash through fastners and rain water bracketsuitable for 75 mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified. |
| 70 | S&F 110 mm bore PVC (SWR) bends any radius complete all as specified and as directed |
| 71 | S&F 75 mm bore PVC (SWR) bends any radius complete all as specified and as directed |
| 72 | S&F in repair 75mm dia of outler cast iron nahani trap , with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed. |
| 73 | S&F in repairs 100mm dia of outler cast iron nahani trap , with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed. |
| 74 | M&L for taking up or taking down existing 15mm bore GI water tubing, including cleaning for refixing or removal to store, complete all as specified and directed.. |
| 75 | M&L for taking up or taking down existing 20mm bore GI water tubing, including cleaning for refixing or removal to store, complete all as specified and directed.. |
| 76 | S&F GI tubing, medium grade, 15mm bore, with all fittings such as tee, bend, elbow etc., fixed to walls or ceilings with saddles/spacers, complete all as specified and directed. |
| 77 | S&F GI tubing, medium grade, 20mm bore, with all fittings such as tee, bend, elbow etc., fixed to walls or ceilings with saddles/spacers, complete all as specified and directed. |
| 78 | S&Fin repairs vitreous china urinal, half-stall type, complete, including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm brass screws, pointing around urinal back in cement, fixing with brackets, flush pipes, inlet and outlet connections, complete all as specified and directed. |
| 79 | S&F in repairs 32mm dia PVC waste pipe for WHB and urinals, fixed complete all as specified and directed. |
| 80 | S&F in repairs fancy-type bib tap, chromium-plated cast copper alloy, 15mm bore, with crutch or butterfly handle, screwed down and fixed, complete all as specified and directed. |
| 81 | S&F in repairs wash hand basin, vitreous china, flat-back type, size 550 × 400 mm, including brackets for fixing, waste brass chromium plated with long screwed shanks and 32mm fly nuts, including bottle trap, complete all as specified and directed. |
| 82 | S&F fancy-type pillar taps, cast copper alloy, lift-type lever head, chromium plated, screwed down, suitable for high-pressure supply, lettered HOT or COLD, with long screwed shanks and fly nuts, screwed for 15mm bore iron pipe and fixed in repairs, complete all as specified and directed. |
| 83 | S&F vitreous china water closet (squatting pan), “Orissa” pattern, size 580 × 440 mm, white, with integral foot rest and ‘P’ trap (excluding flushing cistern), but including PVC flush pipe and provision of lime concrete bedding, fixed in repairs, complete all as specified and directed. |
| 84 | S&F vitreous china wash-down water closet pan (pedestal pattern), white, excluding flushing cistern and flush pipe, fixed as in repairs, complete all as specified and directed. |
| 85 | S&F in repairs seat cover for pedestal pan, plastic water closet seat, black or white, closed pattern with flat bottom and cover, with mild-steel chromium-plated or aluminised hinging device, complete all as specified and directed. |
| 86 | S&F in repairs 10-litre capacity PVC valveless syphonic-action flushing cistern, high or low level, white, complete with inlet ball valve, float and handle (exclusive of brackets), complete all as specified and directed. |
| 87 | S&F in repairs brass chromium-plated towel rail, 20mm dia, D-type, 600mm long between flanges, fixed complete all as specified and directed. |
| 88 | S&F in repairs brass chromium-plated shower rose, 125mm size, complete all as specified and directed. |
| 89 | S&F in repairs stainless steel sink with drainage board made of 1mm thick stainless steel, for kitchen or laboratory use, with plugs, washers and waste fittings, including bedding in cement mortar to dwarf wall or fixing with cantilever brackets, and connecting union to pipe; overall size 915mm × 460mm, bowl size 410mm × 330mm × 160mm, complete all as specified and directed. |
| 90 | S&F in repairs 15mm dia PVC connection pipe, 450mm long, complete all as specified and directed. |
| 91 | M&L for 600 × 450mm beveled-edge mirror, 5mm thick selected quality glass, mounted on 6mm thick AC building board, fixed to wall with wooden plugs, chromium-plated brass screws and cup washers, fixed as in repairs, complete all as specified and directed. |
| 92 | S&F solid PVC door frame, size 50mm × 47mm, made out of 5mm wood-grain printed PVC sheet reinforced with MS square tube, with edges painted to match printed sheet, complete all as specified. |
| 93 | S&F factory-made solid panel PVC door shutter, 30mm thick, consisting of MS tube frame for top and bottom rails. MS frame covered with heat-moulded plain-colour PVC \"C\" channel, with 20mm PVC sheet strip bonded inside using solvent cement for stiles, and plain-colour PVC sheet for top and bottom rails. PVC sheet panelling fitted inside the MS frame, welded/sealed to stiles and rails with suitable PVC sheet bedding, joints bonded with solvent cement; supplying and fixing in frame at site complete all as specified and directed. |
| 94 | S&F 75mm butt hinges with stainless steel hinge pin, bright-polished finish, type B-11, fixed complete all as specified and directed. |
| 95 | S&F 150mm long aluminium anodised barrel tower bolts made from extruded sections, fixed complete all as specified and directed. |
| 96 | S&F in repairs 150mm long aluminium anodised barrel tower bolts of extruded sections, fixed complete all as specified and directed. |
| 97 | S&F 300mm long aluminium alloy anodised sliding door bolts with hasp and staple (bolt type), including fixing clips of sheet/extruded sections and fixing bolts; sliding bolt of extruded or cast aluminium alloy, complete all as specified and directed. |
| 98 | S&F in repairs 300mm long aluminium alloy anodised sliding door bolts with hasp and staple (bolt type), including fixing clips of extruded sections and fixing bolts; sliding bolt of extruded or cast aluminium alloy, complete all as specified and directed. |
| 99 | S&F for 140mm long floor door stopperof aluminium alloy body and tongue, anodised with hard drawn steel spring fixed in floor complete all as specified and as directed |
| 100 | S & F 150mm extruded aluminium alloy handles, cast type as fixed complete all as specified and directed. |
| 101 | S&F in repairs 150mm extruded aluminium alloy handle, cast type, fixed complete all as specified and directed. |
| 102 | S & F 100mm extruded aluminium alloy handles, cast type as fixed complete all as specified and directed. |
| 103 | S&F in repairs 100mm extruded aluminium alloy handle, cast type, fixed complete all as specified and directed. |
| 104 | Dismantling wrought iron or mild steel work of any description not otherwise specifically provided for, complete all as specified and as directed. |
| 105 | S&F framed work such as grills, gratings, sunshades, with bar ends shouldered and/or riveted, welded or forged into spikes; framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, water-tank framework and similar items, conforming to Fe-410-0 or Fe-310-0 steel grade, complete all as specified and as directed. |
| 106 | M&L for structural steel work in roof trusses (framed or trussed), purlins, crane gantries, rails and fastenings, and heavy bracket framing using beams, tees, angles, channels or flat sections, including distance pieces, cleats, etc., complete all as specified and directed by Engineer-in-Charge. |
| 107 | Supply and fix rolled mild steel sections of Grade Fe-410-W (Grade E-250), Quality-A, including plates (plain or chequered), channels for manhole covers, etc., square-cut or notched (ordinary or countersunk) for forming holes, without attachments, complete all as specified. |
| 108 | M&L for preparing new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed. |
| 109 | M&L for preparation of old steel surfaces exceeding 10cm width or girth and applying one coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 110 | S&F expanded metal weighing not exceeding 4.00 kg per sqm, bent to required shape and tied with and including annealed mild steel wire not less than 0.90mm dia, or fixed using galvanised steel staples, supplied and fixed complete to wood or steel members, complete all as specified. |
| 111 | Demolition of stone/brick masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings dressed stone work and pre cast concrete articles complete all as specified and directed. |
| 112 | M&L brickwork with sub class \"B\" bricks , straight or curved on planexc 6m mean raidus built in cement mortar 1:6 complete all as specified and directed |
| 113 | M&L for double action floor spring hydraulically regulated made up of minium 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed all as per manufacturer\"s instruction. |
| 114 | S&F solar control film, 25-micron reflective type, applied to glass panes complete as per manufacturer’s instructions, complete all as specified and directed. |
| 115 | S&F push-type taps for urinals, cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down, suitable for 15 mm dia iron pipe or brass ferrule, and fixed in repairs complete all as specified and directed. |
| 116 | S&F in repairs PVC tube health faucet (ABS body), mild-steel chromium plated, suitable for 15 mm dia pipe, with 1.25 m long flexible tube and ABS wall hook, including making connections and fixing in position, complete in all respects as specified and directed. |
| 117 | S & F Toughened glass, 10 mm thick, used in hinged doors, partitions, automatic doors and similar works, including cutting to shape and drilling holes as required, complete all as specified and directed. |
| 118 | Dismantling plain or corrugated steel sheeting, any gauge or thickness incl Nainital or similar pattern roof coverings all as specified and directed. |
| 119 | S&F pre-painted hot- dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.5 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor for height of building exceeding 10 metres but not exceeding 20 metres complete all as specified and as directed. |
| 120 | S&F pre-painted hot- dip aluminium-zinc alloy metallic coated plain steel sheet, corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.5 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor for height of building exceeding 10 metres but not exceeding 20 metres complete all as specified and as directed. |
| 121 | M & L for 1.5 mm thick galvanised steel sheet as in facia of roof, window chajja and Valley gutters fixed with rivets or other suitable arrangements over MS brackets inany shape/design as required profile with desired slope, including cutting holes, make design etccomplete all as specified and as directed by Engr-in-Charge.(Note: The MS work shall be measured and paid seperatly). |
| 122 | S&F 2 mm thick fibre-glass reinforced translucent plain/corrugated sheeting, with two-corrugation side lap, fixed using L-type / J-type / cranked hooks in lieu of screws, as in roofing or wall cladding, complete all as specified and directed. |
| 123 | S&F in repairs roller-type venitian blinds, made of standard approved-texture cloth with all necessary accessories, complete all as specified and directed. |
| 124 | S&F mirror of selected quality glass, 6 mm thick, bevelled edge, mounted on 6 mm thick AC building board or commercial plywood, including mirror brackets, complete all as specified and directed.ed. |
| 125 | S & F Solid PVC wall lining / panelling, consisting of 5 mm thick plain-colour solid/hollow PVC sheet, inclusive of solvent cement and fixing at site on PVC frame, complete as per specifications and drawing. |
| 126 | S & F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing. |
| 127 | M&L for PCC 100mm thick type D-2 (1:4:8) using 40mm graded aggregate as in sub base all as specified and as directed. |
| 128 | Removing debris exc. 1.50 Km but n exc. 20 Km and depositing where directed, in soil outside MD land. |
| 129 | M&L for preparation of old plastered or unplastered decorated wall surfaces including cornices, pilasters etc., and applying one coat of whitewash, including necessary scaffolding up to mezzanine floor level, complete all as specified and directed. |
| 130 | M&L for preparation of old plastered or unplastered decorated surfaces of ceiling and applying one coat of whitewash, including necessary scaffolding up to mezzanine floor level, complete all as specified and directed. |
| 131 | M&L for complete removal of existing treatment from wall surfaces, preparing and sanding the surfaces to an even and smooth finish, applying one coat of wall primer, and finally applying one coat of oil-bound distemper of approved tint including necessary scaffolding up to mezzanine floor level, complete all as specified and directed. |
| 132 | M&L for complete removal of existing treatment from wall surfaces, preparing and sanding the surfaces to an even and smooth finish, applying one coat of wall primer, and finally applying two coats of oil-bound distemper of approved tint, complete all as specified and directed. |
| 133 | M&L for preparation of old decorated surfaces of wall/ceiling over 10 cm width or girth, stopping of painted surfaces, and applying one coat of plastic emulsion paint, complete all as specified and directed. |
| 134 | M&L for preparation of old decorated surfaces of wall/ceiling over 10 cm width or girth, stopping of painted surfaces, and applying two coats of plastic emulsion paint, complete all as specified and directed. |
| 135 | M&L for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed. |
| 136 | M&L for preparation of old painted steel surfaces of any description not otherwise described, over 10 cm width or girth, and applying one coat of synthetic enamel paint, complete all as specified and directed. |
| 137 | M&L for applying 1.5 mm thick wall-care putty in one coat on wall/ceiling surfaces to achieve an even finish, complete all as specified and directed. |
| 138 | M&L for French polishing on surfaces of any description, width or girth, including cleaning, preparing the surface, applying one coat of wood filler, and one or more coats of French polish on old works, complete all as specified and directed. |
| 139 | M&L for preparation (grinding/brushing/brooming) of PCC flooring and applying 2 mm thick self-levelling epoxy flooring of any colour, including filling of cracks and holes, over a coat of primer, complete all as specified and directed. |
| 140 | M&L for providing false ceiling made of 595×595×4 mm thick fibre-cement board/tiles, fixed on deep-panel suspension system made of powder-coated GI sections: main tee 23.5×38×0.63 mm, cross tee 23.5×23.5×0.63 mm, angle 19×19×0.63 mm, including 3 mm GI wire for suspension, bolts, washers, nuts, cleats, pin hooks etc., complete for securing framework to ceiling grid; including forming required openings for lights/fans and making recesses/patterns as required, complete all as specified and directed. |
| 141 | M&L for preparation of PCC flooring and applying one coat of Indigo floor paint, complete all as specified and directed. |
| 142 | M&L for PCC 75 mm thick, Type D-2 (1:4:8) using 40 mm graded aggregate, as in sub-base, complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail