Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | M&L for point wiring complete with multi stranded copper conductor cable of size 1.5 sqmm PVC insulated unsheathed FRLS colour coded 1100 volts grade drawn in and including surface/ concealed stove enamelled medium grade ERW steel conduit of size 19/ 20mm dia or higher size with all fittings such as tees, bends etc. including PVC insulated unshearthed 1.5 sqmm multistranded copper conductor cable FRLS colour code cable1100 volts grade for earth continuity for one light point controlled by one flame proof switchincluding taking down old copper/ aluminium point wiring (light, fan, socket or power) complete, including conduits/ casing capings etc and making good disturbed surface of walls, floors, etc. complete all as specified and directed. |
| 2 | All as per item No 1.00 above but with 2.5 sqmm PVC insulated cables for 3 pin 16 amp multipurpose outlet on independent board including 2.5 sqmm PVC insulated copper wire for earth continuity on independent board complete. |
| 3 | M&L for point wiring using stranded copper conductor FRLSH cable of size 1.5 sqmm, PVC insulated unsheathed complete in existing concealed/surface conduit and sunken terminal boxes and with new 3 mm thick hylam sheet for mounting of switches, sockets, fan regulators etc with screws and 1.5 sqmm PVC insulated stranded copper conductor FRLSH cable as continues earth wire connected to common earth dolly incl taking down old copper/aluminium point wiring (light, fan, socket or power) from existing surface/concealed conduits, casing/caping etc and making good disturbed surfaces of walls, floors etc for the following complete all as specified and directed :- |
| 4 | One light point controlled by one switch/ fan point controlled by one switch . |
| 5 | One three pin 6 amp socket outlet multipurpose on independent board. |
| 6 | One three pin 6 Amp switch socket outlet on the same board with other switches. |
| 7 | All as per item No 3.00 above but with 2.5 sqmm PVC insulated cables for 3 pin 16 amp multipurpose outlet on independent board including 2.5 sqmm PVC insulated copper wire for earth continuity on independent board complete. Sunken terminal boxes, if required, shall be measured and paid separately under respective items |
| 8 | S&F in replacement of switch piano type, flush type, single pole, one way, 6 Amps complete all as specified and directed. |
| 9 | S&F in replacement of socket outlet flush type 2/ 3 pins,6 Amps multipurpose complete all as specified and directed. |
| 10 | S&F in replacement of switch piano type, flush type, single pole, one way, 16 Amps complete all as specified and directed. |
| 11 | S&F in replacement of socket outlet, flush type, multi purpose 3 pin, 6 Amps & 16 Amps, 230 volts complete all as specified and directed. |
| 12 | S&F in replacement ceiling fan regulators, step type, electronic for 1200/ 1400mm sweepcomplete all as specified and directed. |
| 13 | S&F in replacement LED lamp 9 watt complete all as specified and directed. |
| 14 | S&F in repairs ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals, complete all as specified and directed. |
| 15 | S&F in replacement MCB SP 240 volts 6 to 32 Amps \"B\" curve type all as specified and directed. |
| 16 | S&F in replacement MCB SP 240 volts 63 Amps \"B\" curve type all as specified and directed. |
| 17 | S&F in replacement MCB SPN 240 volts 6 to 32 Amps ‘B’ curve complete all as specified and directed. |
| 18 | S&F in replacement MCB TPN 240 volts 32 to 63 Amps ‘B’ curve complete all as specified and directed. |
| 19 | S&F in replacement of MCCB, 4 pole, 400 Amps, 36 KA, 50Hz, 415 volts with Ics= 100% of Icu complete with adjustable typecompleteall specified and directed. |
| 20 | S&F in replacement of MCCB, 4 pole, 250 Amps, 36 KA, 50Hz, 415 volts with Ics= 100% of Icu complete with adjustable typecompleteall specified and directed. |
| 21 | S&F in replacement of MCCB, 4 pole, 200 Amps, 36 KA, 50Hz, 415 volts with Ics= 100% of Icu complete with adjustable typecompleteall specified and directed. |
| 22 | S&F in replacement of MCCB, 4 pole, 160 Amps, 36 KA, 50Hz, 415 volts with Ics= 100% of Icu complete with adjustable typecompleteall specified and directed. |
| 23 | S&F in replacement of MCCB, 4 pole, 125 Amps, 16 KA, 50Hz, 415 volts with Ics= 100% of Icu complete with adjustable typecompleteall specified and directed. |
| 24 | S&F in replacement of MCCB, 4 pole, 100 Amps, 16 KA, 50Hz, 415 volts with Ics= 100% of Icu complete with adjustable typecompleteall specified and directed. |
| 25 | S&F in replacement of MCCB, 4 pole, 63 Amps, 16 KA, 50Hz, 415 volts with Ics= 100% of Icu complete with adjustabletypecompleteall specified and directed. |
| 26 | S&F in replacement of MCCB TP 63 to 100 Amps, 415 volts AC, 16 KA with adjustable thermal and magnetic setting complete all as specified and directed. |
| 27 | S&F in replacement sheet metal enclosure for incoming MCCB and outgoing MCBs factory made double door, VTPN 415 volts 4 ways with 200 Amp bus bar with IP43 protection complete in all aspects all as specified and directed. |
| 28 | S&F in replacement of MCCB FP 100 Amps, 415 volts AC, 25 KA with and including SS enclosure wall mounting type with lockable front door fabricated from 2mm thick CRCA sheet duly powder coatedcomplete all as specified and directed. |
| 29 | S&F in replacement of MCCB FP 100 Amps, 415 volts AC, 25 KA with and including SS enclosure wall mounting type with lockable front door fabricated from 2mm thick CRCA sheet duly powder coatedcomplete all as specified and directed. |
| 30 | S&F in replacement DB sheet metal enclosure double door for MCB’s company made, SPN 240 Volts 8 ways with IP 42 protection with 200 amps rated bus bars complete all as specified and directed. |
| 31 | S&F in replacement DB sheet metal enclosure double door for MCB’s company made, SPN 240 Volts 4 ways with IP 42 protection with 200 amps rated bus bars complete all as specified and directed. |
| 32 | Supply, install, test & commissioning factory made LT feeder pillar box of suitable size with set of 4 strip copper bus bar 300 Amp, 1100 volt grade, 60cm long duly sleeved with relevant colored sleeved cubical outdoor type, weather proof, fabricated out 14 SWG MS sheet, welded on 40mm x40mm x 6mm angle iron frame & having four Nos 120cm long legs made out of 40mm x 40mm x 6mm angle iron below frame grouted on ground in concrete block of size 80mm x 80mm x 100mm built in PCC (1:2:4) of suitable size with front & rear openable door having locking arrangements, bottom space for cable entry with duly internally and externally painted with two coats of dark grey synthetic enamel paint over a coat of red oxide primer including dismantling and taking down existing feeder pillar box complete all as specified and directed. |
| 33 | M&L for submain wiring complete with two runs of 4.0 sqmm single core, multi-stranded, FRLS PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through existing surface/concealed conduits with one run of 4.0 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring complete all as specified. Note: Two runs of 4.0 sqmm multi-stranded cable and one run of 4.0sqmm cable as earth continuity conductorshall be considered as one unit length. |
| 34 | M&L for submain wiring complete with two runs of 6.0 sqmm single core, multi-stranded, FRLS PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through existing surface/concealed conduits with one run of 6.0 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring complete all as specified. Note: Two runs of 6.0 sqmm multi-stranded cable and one run of 6.0sqmm cable as earth continuity conductorshall be considered as one unit length. |
| 35 | M&L for submain wiring complete with two runs of 2.5 sqmm single core, multi-stranded, FRLS PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn in and including surface/ concealed stove enamelled medium grade ERW steel conduit of size 19/ 20mm dia or higher size with all fittings such as tees, bends etc. with one run of 2.5 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring complete all as specified. Note: Two runs of 2.5 sqmm multi-stranded cable, one run of 2.5sqmm cable as earth continuity conductor AND one run ofERW steel conduit shall be considered as one unit length. |
| 36 | S&F in replacement LED street light fitting 150 Watt 230 volts AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 37 | S&F in replacement LED street light fitting 90 Watt 230 volts AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 38 | S&F in replacement of LED flood light luminaries 200W made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP-66 protection system efficacy not less than 110 LPWwith 10 KV complete with electrical connections all as specified and directed. |
| 39 | S&F in replacement LED lights fitting4 feet long 1x 20 W, 220V, AC decorative box batten type with driver, holder etc including electrical connection with ceiling rose complete all as specified and directed. |
| 40 | S&F in replacement flameproof LED light fixture well glass fittingfor 60 watt capacity and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directe |
| 41 | M&L for replacement of LED light fitting 2 x 16/ 20 watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories duly prewired including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed. |
| 42 | S&F in replacement flame proof rotary on/ off switch direct entry in LM6, 16 amp single pole 250 volt complete all as directed. |
| 43 | S&F in replacement flame proof rotary on/ off switch with termination boxin LM6, 16 amp single pole 250 volt complete all as directed. |
| 44 | Supply, laying, jointing and testing LT XLPE cable insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 185 sqmm 3½ core laid in trenches/ passing through GI tubing etc. including taking out existing LT XLPE cable complete as specified and directed. |
| 45 | Supply, laying, jointing and testing LT XLPE cable insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 150 sqmm 3½ core laid in trenches/ passing through GI tubing etc. including taking out existing LT XLPE cable complete as specified and directed. |
| 46 | Supply, laying, jointing and testing LT XLPE cable insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 120 sqmm 3½ core laid in trenches/ passing through GI tubing etc. including taking out existing LT XLPE cable complete as specified and directed. |
| 47 | Supply, laying, jointing and testing LT XLPE cable insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 sqmm 3½ core laid in trenches/ passing through GI tubing etc. including taking out existing LT XLPE cable complete as specified and directed. |
| 48 | Supply, laying, jointing and testing LT XLPE cable insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 sqmm 3½ core laid in trenches/ passing through GI tubing etc. including taking out existing LT XLPE cable complete as specified and directed. |
| 49 | Supply, laying, jointing and testing LT XLPE cable insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 sqmm 3½ core laid in trenches/ passing through GI tubing etc. including taking out existing LT XLPE cable complete as specified and directed. |
| 50 | Supply, laying, jointing and testing LT XLPE cable insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm 3½ core laid in trenches/ passing through GI tubing etc. including taking out existing LT XLPE cable complete as specified and directed. |
| 51 | Supply, laying, jointing and testing LT XLPE cable insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 4 core laid in trenches/ passing through GI tubing etc. including taking out existing LT XLPE cable complete as specified and directed. |
| 52 | Supply, laying, jointing and testing LT XLPE cable insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core laid in trenches/ passing through GI tubing etc. including taking out existing LT XLPE cable complete as specified and directed. |
| 53 | Supply, laying, jointing and testing LT XLPE cable insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 2 core laid in trenches/ passing through GI tubing etc. including taking out existing LT XLPE cable complete as specified and directed. |
| 54 | Supplying and fixing 10sqmm flat twin core heavy duty cable 1100 volts grade PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire including taking down existing cable complete all as specified and directed. |
| 55 | M&L for painting of electric pole upto 9m high complete with cross arm, clamps, channel etc. after cleaning exposed surfaces with two coat super enamelled paint as per existing colour i.e. Silver (Aluminium paint) and writing letters and pole Nos or figures (Block. Roman, Italic or Indian) n. exc. 30 cm high complete all as specified and directed. |
| 56 | S&F in repairs digital type voltmeter 0 to 500 volts panel mounted with selector switch complete all as specified and directed. |
| 57 | Supply and fixing digital type ammeter 0 to 300 ampere panel mounted with selector switch and CTs 300/5A complete all as specified and directed. |
| 58 | S&F in replacement LED indicator lamps in RBY colour complete all as specified and directed. |
| 59 | Excavation in trenches in soft/ loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation of pole, laying of cable etc. and getting out complete all as specified and directed. |
| 60 | Returning and filling in excavated soil in layer not exceeding 25cm thick in including spreading, levelling, watering and well ramming in soft/ loose soil complete all as specified and directed. |
| 61 | Removing excavated surplus soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5mtrs above the starting points complete all as specified and directed. |
| 62 | M&L for sand cushioning to cables with a layer of sand 8cm deep before laying the cable and 15cm depth after laying & stretching of cable) complete all as specified. Note: Punned thickness overall 18cm shall be measured & paid. |
| 63 | Supply and laying old size sub class ‘B’ bricks as in protection of cable laid dry flat perpendicular to direction of cable abutting each other complete all specified and directed. |
| 64 | M&L for boring hole horizontally under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including supply & laying 150mm dia HDPE pipe suitable for 0.4 mpa working pressure complete all as specified and directed. |
| 65 | Supply and laying GI tubing 50mm bore light grade GI tubing with all fitting laid in trenches or fixed to well etc. complete all as specified and directed. |
| 66 | S&F in repairs porcelain/ epoxy insulators of size approximate 50mm x 25mm x 25mm for fixing of roof/ down conductor complete with fixing screws etc. dully fixed in wall/ roof with PVC rawl plugs and fixing screws complete all as directed. |
| 67 | M&L for replacement of aluminium strip 25mm x 3mmfor roof conductor and down conductor above ground complete all as specified and directed. |
| 68 | M&L for replacement of copper strip 20mm x 3mmfor roof conductor and down conductor above ground complete all as specified and directed. |
| 69 | Supply and fixing in replacement 12mm dia, 300mm long end termination aluminium rod fitted with rivets/ nuts & bolts on and including 32mm bore medium grade GI pipe 1.20m long duly grouted in PCC block of size 300mm x 300mm x 450mm built in PCC (1:3:6) type C-2 using graded stone aggregate complete all as specified and directed. |
| 70 | S&F in replacement concealed type flush mounted MS sunken boxes 18 gauge thickness suitable for mounting switch/ sockets including 3mm thick PVC laminated sheet complete with earthing terminal and good quality threads incl making good the disturbed surfaces complete all as directed for the following :- |
| 71 | Size 7\" x 5\" |
| 72 | Size 8\" x 10\" |
| 73 | Size 12\" x 10\" |
| 74 | M&L for danger notice plate of size 20cm x 15cm fabricated out of 1.6mm thick mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size fixed in replacement complete all as specified and directed. |
| 75 | S&F stainless steel (SS-304 grade) friction hinges of size 200mm long fixed to LT panels of approved quality, fixed by welding/ stainless steel screws etc. complete all as specified and directed. |
| 76 | S&F indoor/ outdoor type heat shrinkable type cable jointing kit for LT 1100 volts grade cable for straight through joint complete with accessories suitable for 3½/ 4 core XLPE armoured aluminium conductor cable of size 25 to 50 sqmm complete all as specified and directed. |
| 77 | All as per item No. 70.00 above but for cable of size 70 to 95 Sqmm. |
| 78 | All as per item No. 70.00 above but for cable of size 120 to 150 Sqmm. |
| 79 | M&L in replacement for earthing complete with galvanised steel earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connectionsusing galvanised iron strip of size 25mm x 4mm thick (upto body of equipment) by means of bolts, nut check nuts and washers earth strip protected by galvanized steel pipe 40mm bore (medium grade) connected to test point all as shown in electrical plate No. 3 of SSR - 2009 (Part-I) and including necessary excavation and earth work in any type of soil, 20mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber shall be constructed 500mm away from the edge of earth pit, pit cover of precast RCC (1:1½:3), type B-1, 80mm thick reinforced XPM of weight not less than 4 Kg/ Sqm. complete & connected to earthing test point all as specified or indicated including brazing/ testing on completion complete all as specified and directed. Notes:- (i) The unit rate includes galvanised Iron strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/ test point. (ii) Old earthing may have been burried down to a depth of exceeding 2.25m below ground level. No extra payment will be made if excavation is done beyond 2.25m depth to retrieve the old earthing. |
| 80 | Earthing complete with copper earth plate electrode 60cm x 60cm x 3.15mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to copper earth lead strip 20mm x 3mm by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber (1:3:6) type C-1, pit cover of precast RCC (1:1½:3) type A-1 using graded stone aggregate & reinforced with XPM weighing not less than 4 kg/ sqm and frame, charcoal, salt includingearth lead protected by 40mm dia medium grade GI pipe and 20mm dia medium grade GI Pipe for watering including dismantling existing earthing complete all as specified and directed. Note:- Copper earth lead strip 20mm x 3mm and GI 40mm dia protection pipe upto 7.5 mtr length will be deemed to include in the unit rate quoted. Old earthing shall be conventional type and may have been burried down to a depth of exceeding 2.25m below ground level. No extra payment will be made if excavation is done beyond 2.25m depth to retrieve the old earthing. |
| 81 | Supply, installation, testingand commissioning in replacement LT cubical panel (CPRI Approved) of suitable size factory made, compartment type, dust and vermin proof(IP-65) duly powder coatedoutdoor type suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out 3.15 mm MS Sheet on 50mm x 50mm x 6mm angle iron frame, 120cm long angle iron legs for grouting in floor with cement concrete PCC foundation of suitable size in (1:2:4) and front & rear double door type inclusive locking arrangement & two coat of super enameled first grade quality synthetic enamel paint over coat of red oxide primer with provision of all incoming/ outgoing cable entries alongwith suitable size of double compression type cable gland for incoming & out going cable complete all as specified and comprising the following:- |
| 82 | (a) LT bus bar aluminum 200 Amps, 4 strips, duly sleeved with relevant colored insulation heavy duly mounted on insulators = 1 SetIncoming: (b) Digital MCCB AC, 4 pole, 250 Amps, 36 KA, 50 Hz, 415 volts adjustable type (ICs = 75% of ICu)- 01 No.Outgoing :(c) Digital MCCB AC, 4 pole, 200 Amps, 36 KA, 50 Hz, 415 volts adjustable type (ICs = 100% of ICu)- 1 No.(d) Digital MCCB AC, 4 pole,160 Amps, 36 KA, 50 Hz, 415 volts adjustable type (ICs = 100% of ICu)- 2 Nos.(e) Digital LED ammeter with CT’s 400/5 amps and selector switch- 01 No.(f) Digital LED voltmeter 0-500 volts with selector switch- 1No.(g) Phase indicator lamps RYB- 01 Set.(h) Internal connections with colour code copper cable multistranded of suitable size copper thimbles etc. as per manufacturers design and specifications.(j) Danger notice plate 440 V with conventional skull and bones in red signal colour- 01 No.(k) Spare space for mounting 01 No. extra MCCB. |
| 83 | Supply, installation, testingand commissioning in replacement LT cubical panel (CPRI Approved) of suitable size factory made, compartment type, dust and vermin proof(IP-65) duly powder coatedoutdoor type suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out 3.15 mm MS Sheet on 50mm x 50mm x 6mm angle iron frame, 120cm long angle iron legs for grouting in floor with cement concrete PCC foundation of suitable size in (1:2:4) and front & rear double door type inclusive locking arrangement & two coat of super enameled first grade quality synthetic enamel paint over coat of red oxide primer with provision of all incoming/ outgoing cable entries alongwith suitable size of double compression type cable gland for incoming & out going cable complete all as specified and comprising the following:- |
| 84 | (a) LT bus bar aluminum 200 Amps, 4 strips, duly sleeved with relevant colored insulation heavy duly mounted on insulators = 1 SetIncoming: (b) Digital MCCB AC, 4 pole, 160 Amps, 36 KA, 50 Hz, 415 volts adjustable type (ICs = 75% of ICu)- 01 No.Outgoing :(c) Digital MCCB AC, 4 pole, 63 Amps, 16 KA, 50 Hz, 415 volts adjustable type (ICs = 100% of ICu)- 4 Nos.(d) Digital LED ammeter with CT’s 400/5 amps and selector switch- 01 No.(e) Digital LED voltmeter 0-500 volts with selector switch- 1No.(f) Phase indicator lamps RYB- 01 Set.(g) Internal connections with colour code copper cable multistranded of suitable size copper thimbles etc. as per manufacturers design and specifications.(h) Danger notice plate 440 V with conventional skull and bones in red signal colour- 01 No.(j) Spare space for mounting 01 No. extra MCCB. |
| 85 | Supply, installation, testingand commissioning in replacement LT cubical panel (CPRI Approved) of suitable size factory made, compartment type, dust and vermin proof(IP-65) duly powder coatedoutdoor type suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out 3.15 mm MS Sheet on 50mm x 50mm x 6mm angle iron frame, 120cm long angle iron legs for grouting in floor with cement concrete PCC foundation of suitable size in (1:2:4) and front & rear double door type inclusive locking arrangement & two coat of super enameled first grade quality synthetic enamel paint over coat of red oxide primer with provision of all incoming/ outgoing cable entries alongwith suitable size of double compression type cable gland for incoming & out going cable complete all as specified and comprising the following:- |
| 86 | (a) LT bus bar aluminum 200 Amps, 4 strips, duly sleeved with relevant colored insulation heavy duly mounted on insulators = 1 SetIncoming: (b) Digital MCCB AC, 4 pole, 250 Amps, 36 KA, 50 Hz, 415 volts fixed type (ICs = 75% of ICu)- 01 No.Outgoing :(c) Digital MCCB AC, 4 pole, 125 Amps, 36 KA, 50 Hz, 415 volts fixed type (ICs = 100% of ICu)- 1 No.(d) Digital MCCB AC, 4 pole,100 Amps, 36 KA, 50 Hz, 415 volts fixed type (ICs = 100% of ICu)- 2 Nos.(e) Digital MCCB AC, 4 pole, 63 Amps, 36 KA, 50 Hz, 415 volts fixed type (ICs = 100% of ICu)- 2 Nos.(f) Digital LED ammeter with CT’s 400/5 amps and selector switch- 01 No.(g) Digital LED voltmeter 0-500 volts with selector switch- 1No.(h) Phase indicator lamps RYB- 01 Set.(j) Internal connections with colour code copper cable multistranded of suitable size copper thimbles etc. as per manufacturers design and specifications.(k) Danger notice plate 440 V with conventional skull and bones in red signal colour- 01 No.(l) Spare space for mounting 01 No. extra MCCB. |
| 87 | S&F Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete swan neck type with cast iron base plate, final, taper plug, bolts, nuts and screws as specified,including necessary excavation and earth work , PCC 1:4:8 type D-2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block /coping etc including finishing the exposed surfraces even and smooth without using extra cement and necssary form work, disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps withsynthetic enamel paint and 2 bands with Black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint in and including taking down of old unservicable pole ,complete all as specified and as directed by Engineer in charge.Notes : (i) Cost of Transportation of Pole at location shall deemed to be included in the rate quoted by contractor against this item and nothing extra shall be admissible on this account .(ii) Quoted rate of this item is deemed to inclusive cost of all the itmes mentioned therein such as earth work, PCC ,Form work ,finishes including painting etc and nothing extra shall be admissible on this account . |
| 88 | S&F in replacement 8 Watt bollard light pressure die cast powder coated housing with PC diffuser efficient high output LED with IP65 protection including PCC foundation of suitable sizecomplete all as specified and directed. |
| 89 | S&F in replacement post of lantern LED 50 watt for 360 degree indirect light with IP65 protection, resistant to impact and corrosion, glarefare complete all as specified and directed. |
| 90 | Site clearance including cutting of grass/ trimming of all bushes/ small trees upto a height of 10 feet in surrounding areas of perimeter security lights, E/M installations, panels, bus bar chambers etc. including sprinkling of herbicide solution as per manufacturer\"s instructions complete all as specified and directed. |
| 91 | S&F Hot dip galvanised Octagonalpole 7 metre long ,top dia 70 mm, bottom dia 130mm having sheet thickness 3 mm , base plate 220mmx220mmx12mm(LxBxT) including foundation bolt of size 4x20 mm dia ,225 mm pitch circle dia, 700 mm bolt length, 100 mm projected bolt length, having door opening of size 90x500 mm above GL and having hot dip galvansied double arm plane bracket 1000 mmlong for pole having top 70 mm dia for mounting street light fitting fixed on top with nut ,bolts and washersetcincluding provision of cable 2.5 sqmm, 3 core and cable connector for three phase supply and one no MCB SP of 0.6 Amp to 6 Ampincluding necessary excavation and earth work includingdisposal of surplus soil to a distance not exceeding 50 m, PCC 1:3:6 type C-1and iron works complete all as per the instructions of the manufacturer in and including taking down of old unservicable pole ,complete all as specified and as directed by Engineer in charge.Make : Crompton Model No. HM-1107P or equivalent make of surya/HPL/Bajaj or makesmentioned in Appendix of Makesas approved by GE.Notes : (i) Cost of Transportation of Pole at location shall deemed to be included in the rate quoted by contractor against this item and nothing extra shall be admissible on this account .(ii) Quoted rate of this item is deemed to inclusive cost of all the itmes mentioned therein such as earth work, PCC ,Iron work etc etc and nothing extra shall be admissible on this account . |
| 92 | Supply, fixing, testing and commissioning in replacement of Air Circuit Breaker (ACB) 1000 Amps, 4 pole with microprocessor release IPR 1+ ,50 kA, 415 Volt, manual drawout type conforms to IS/IEC:60947-2 in existing place including removing of LT connection to old ACB and jointing of LT connection to new ACB complete all as specified and directed.Make: Havells Model Titania E series IPR E+ or equivalent in performance in L&T/ Siemens/ ABB as approved by GE.Note: Mentioned work will be carried out by manufacturer\"s representative only to the entire satisfaction of Engineer-in-charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail