| 1 | Demolition and breaking up 150 mm dia drain pipes (SGSW/ AC/RCC) including hunching and benching set in cement mortar and removal of debris out side from MoD land complete all as specified and as directed. |
| 2 | Demolition and breaking up 200 mm dia drain pipes (SGSW/ AC/RCC) including hunching and benching set in cement mortar and removal of debris out side from MoD land complete all as specified and as directed. |
| 3 | Demolition and breaking up 300 mm dia drain pipes (SGSW/ AC/RCC) including hunching and benching set in cement mortar and removal of debris out side from MoD land complete all as specified and as directed. |
| 4 | Excavation in trenches not exc 1.5m wide and not exceeding 1.5 mtr in depth for foundation etc shaft, cesspits, manholes sewage line etc not exc. 10 Sqm on plan and getting out complete all as specified and directed. |
| 5 | -ditto- all as per item No 4have in before but depth exceeding 1.5mts and not exc 3mtr all as specified and directed. |
| 6 | Returning, filling in, trenches with soil in layers not exc 25 cm thick, watering and well ramming complete all as specified and directed. |
| 7 | Removal of surplus soil to a distance not exc 50 mtr away & deposting where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 8 | M&L for PCC 1:4:8 type D-2(using 40mm graded crushed stone aggregates) bedding forsewage lines of 150mm dia incl packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed. |
| 9 | All as per sl item No 8 above but for bed of sewage line of 200mm dia all as specified and directed. |
| 10 | M& L for PCC 1:4:8 type D2 (using 40 mm grade stone aggregate)as in bed to drain pipe 300 mm bore including forming cradles complete all as specified and directed. |
| 11 | M & L for 150 mm bore of RCC hume pipe class NP2 laid and and jointed complete with colleres and laid in trenches with laying pipeslevel and testedcomplete all as specified and as directed. |
| 12 | M & L for 200 mm bore of RCC hume pipe class NP2 laid and and jointed complete with colleres and laid in trenches with laying pipeslevel and testedcomplete all as specified and as directed. |
| 13 | M & L for 300 mm bore of RCC hume pipe class NP2 laid and and jointed complete with colleres and laid in trenches with laying pipeslevel and testedcomplete all as specified and as directed. |
| 14 | S&F DWCPE (SN8) nominal size 150 mm (internal dia) mm including all fixing accessories or fittings like socket/spigot joint with elastomeric sealing ring,rubber ring, SILAID rubber lubricants required for laying of pipes, laid in trenches, complete all as specified and as directed. |
| 15 | S&F DWCPE (SN8) nominal size 200 mm (internal dia) including all fixing accessories or fittings like socket/spigot joint with elastomeric sealing ring,rubber ring, SILAID rubber lubricants required for laying of pipes, laid in trenches, complete all as specified and as directed. |
| 16 | S&F DWCPE (SN8) nominal size 200 mm (internal dia) including all fixing accessories or fittings like socket/spigot joint with elastomeric sealing ring,rubber ring, SILAID rubber lubricants required for laying of pipes, laid in trenches, complete all as specified and as directed. |
| 17 | Cutting opening in PCC floor (surface area not exceeding0.09Sqm each hole) and removing materials in sunken floor filling, repairing/replacing the nahni traps/floors traps using quick setting cement and filling back in the sunken floor portion using with PCC1:5:10 type E-2 (using 40mm graded crushed stone aggregate) including provision ofnon skid ceramic coloured tiles 300mm x 300mm x 7mm thick in flooring over 10mm screed bed in cement mortar 1:4, complete all as specified and as directed at site by Engineer-in-Charge. (Note : Nahani trap/Floor trap shall be measured and paid seperately) |
| 18 | Cutting in to existing manholes for connecting new drains, making good to pipe & rendering cutting out existing benching for and forming branch channel in cement concrete1:2:4 type B-1 smooth finished and reforming benching as required for 150 mm bore drain pipe complete all as specified and as directed. |
| 19 | Cutting in to existing manholes for connecting new drains, making good to pipe & rendering cutting out existing benching for and forming branch channel in cement concrete1:2:4 type B-1 smooth finished and reforming benching as required for 200 mm bore drain pipe complete all as specified and as directed. |
| 20 | Cutting in to existing manholes for connecting new drains, making good to pipe & rendering cutting out existing benching for and forming branch channel in cement concrete1:2:4 type B-1 smooth finished and reforming benching as required for 300 mm bore drain pipe complete all as specified and as directed. |
| 21 | M & L for PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in surface channels and drains all as specified and directed. |
| 22 | M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation etc,complete all as specified& directed |
| 23 | Cleaning of sewage line.Mechanically operated 25 tonne truck mounted desludger with 12000Ltr capacity tankerhaving water fitted high pressure jetmachine for cleaning and desludging of sewage line, shall be used by the contractor as per scheduled programme in writingand completion of each jobto the entire satisfaction of Engineer-in-Charge as instructed.( NOTE : In case contractor fails to deploy the machine as per scheduled programme a recovery of Rs 500/- per day shall be deducted from his payment.) |
| 24 | Demolition of brick work built in cement mortar of any description incl cleaning & stoking serviciable brick complete all as specified and directed. |
| 25 | M&L for brick work with sub-class \"B\" bricks (old size)straight or curved on plan exceeding 6 mtrs mean readius built in CM 1:4 complete all as specified and directed. |
| 26 | All as per aboveitem No 25 except bricks. (By using brick obtained from srl. item No. 24) |
| 27 | M&L for rendering 15mm in cement mortar 1:4 mixed with WPC @ 3% by weight of cement or as per manufacturer\"s instructions(whicherver may be higher)to fair faces of brick or conrete surfaces finished even and smooth without using extra cement complete all as specified and directed. (WPC sall be measured & paid for speparately ) |
| 28 | Supply only integral water proofing compound ISI marked complete all as specified and directed. |
| 29 | Taking down cement plaster of any description on brickwalls, etc including raking out joints, hacking for key scrubbing down with water etc |
| 30 | M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces (Cement plaster 1:4) finished even and smooth without using extra cement |
| 31 | M&L for applying two coats of cement base paint over a coat of cement primer on newly plastered surfaces of wall complete all as specified and directed. |
| 32 | M&L for preparationof new plastered/unplastered external surface of wall and two coats ofweatherproof exterior emulsion paint of Asian or equivalent as per approved make list in Particular Specification, incl one coat of primer as specified and all as directed.(The work shall be exicuted in G+ 8th floor Height)Note:- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes.2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. NOTE (a)The work mentioned in aboveitemsshall be carried out including in multi storied buildings (G+8) which may require scaffolding or Jhulla arrangements or any other T&P items are included in the quoted rates by the contractor. |
| 33 | M&L for preparation external wall and ceiling surface old/new by complete removal of existing treatment of walls for upto 4 storey buildings by mechanised sander of Berger Paints or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools and applying a layer of 1mm thick wall care putty, again sand papering thus making surface smooth and applying one coat of primer andapplying two coats of weather proofing exterior acrylic emulsion paint premium quality of make berger or equivalent as per approved make list in Particular specification on wall surfaces complete all as specified and directed by Engr-in-charge. Note : 1. Stage for prepration of surfaces shall be approved from GE before applying the finishes.2. Material shall be procured from manufacturer and work shall be executed through authorised applicator. 3. The work will be also executed at Highrise bldgs and necessary T&P, scaffoling is included in Quoted rates. |
| 34 | S&F Precast Plastic fibre reinforced concrete manhole cover medium duty of size 1000mm x 500mm x 70mm confoming to IS- 12592incldimolition of old RCC work , complete all as specified and directed. |
| 35 | S&F in repairs oval access doors suitable for bend/branches pieces for 100mm bore CI pipe NOTE:-The work will be also executed at Highrise bldgs and necessary T&P, scaffoling is included in Quoted rates. |
| 36 | S&F in repairs oval access doors suitable for bend/branches pieces for 75mm bore CI pipe. NOTE:-The work will be also executed at Highrise bldgs and necessary T&P, scaffoling is included in Quoted rates. |
| 37 | Taking down eaves gutters and rain water pipes ( any size or pattern) , including all fittings , heads, shoes, bends, swan necks, etc., including cleaning or refixing or removal to store ( measured overall as fixed along the centre line over fittings and accessoriesNOTE:-The work will be also executed at Highrise bldgs and necessary T&P, scaffoling is included in Quoted rates. |
| 38 | S&F 75mm bore PVC (SWR) pipes, single socketed, in any length, with rubber ringsfixed to walls or laid in floors/trenches complete all as specified and directed NOTE:-The work will be also executed at Highrise bldgs and necessary T&P, scaffoling is included in Quoted rates. |
| 39 | S&F 110mm bore PVC (SWR) pipes, single socketed, in any length, with rubber ringsfixed to walls or laid in floors/trenches complete all as specified and directed NOTE:-The work will be also executed at Highrise bldgs and necessary T&P, scaffoling is included in Quoted rates. |
| 40 | M&L in repair 75mm bore PVC (SWR) floor/nahanitrap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 41 | S&F PVC (SWR) bend any radius provided with access doors complete allas specified and directed. Bore 75mm |
| 42 | S&F PVC (SWR) bend any radius provided with access doors complete allas specified and directed. Bore 110mm |
| 43 | S & F Sand cast iron soil waste and vent pipes 100mm dia, in any length, with cement joints, laid in trenches/floors, fixed to walls/floors with CI/MSclamps and conforming to IS-1729, complete all as specified and as directed.NOTE:-The work will be also executed at Highrise bldgs and necessary T&P, scaffoling is included in Quoted rates. |
| 44 | S&F Sand cast iron soil waste and vent pipes75 mm dia, in any length, with cement joints, laid in trenches/floors, fixed to walls/floors with CI/MS clamps and conforming to IS-1729, complete all as specified and as directed.NOTE:-The work will be also executed at Highrise bldgs and necessary T&P, scaffoling is included in Quoted rates. |
| 45 | S&F CI bend for 100mm bore any radius, diminishing pieces or tapers (larger bore measured), fixed to walls, complete all as specified and as directed. |
| 46 | S&F CI bend for 75mm bore any radius, diminishing pieces or tapers (larger bore measured), fixed to walls, complete all as specified and as directed. |
| 47 | S&F CI Branch pieces with access door , single (equal or unequal ), ordinary or inverted ) (spigot or socket type ) or with parallel branches complete all as specified & directed.Bore of pipe 75 mm |
| 48 | S&F CI Branch pieces with access door , single (equal or unequal ), ordinary or inverted ) (spigot or socket type ) or with parallel branches complete all as specified & directed.Bore of pipe 100 mm |
| 49 | M&L in repair 75mm bore CI floor trap/nahani trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 50 | S&F in repair vitreous ChinaSquatting pan \"Orrisa\" pattren size 580x440mm white with integral foot rest completeMake CERA/HINDWARE/PARRYWARE |
| 51 | S& f in repair10ltrs PVC valveless, syphonic ac-tion type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed. |
| 52 | S&F in repairs vitreous china wash down water closet pan pedestal pattern white including fixing bolts (excluding flushing cistern and flush pipe). Make: CERA/HINDWARE/PARRYWARE |
| 53 | . Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish of the premises. |
| 54 | . S&F non skid ceramic cloured tiles (300x300mm)x7mm thick, in floors etc, set and jointed in neat cement slurry and pointed in white or cloured cement to match the colour of tiles including 15 mm thk screed bed in CM 1:6 complete all as specified and directed |
| 55 | M&L for glazed coloured ceremic tiles sizes 600x300x 7mm thk tileson vertical surfaces , such as skirting/dado ,set and jointed in neat cement slurry and pointed in white or coloured cement to match the shadeof the tilesincluding 10 mm thk rendering in CM 1:4complete all as specified and directed. |
| 56 | Cutting shrubs wild gorwth/treesand removing complete vegetation growth from walls including taking out roots from roof/brick work or concrete surfaces and making good the distrubed surfaces with PCC 1:2:4 type B-0, using 12.5mm graded crushed stone aggregate and disposing the rubbish from the site (MOD land) for a block up to 9 storey, complete all as specified.( Note : Rate in this item include cutting tress and shrub in each block any number of time during the currency of contract.) |
| 57 | Dismantling posts or struts (woo,steel, or RCC) any section, incl taking out embedded portion & making good disturbed ground,post embedded in concrete , brick work, masonary etc. |
| 58 | M & L for mild steel work , Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat ironfillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 including erection in ground complete all as specified and directed. |
| 59 | S&F Mild steel screw bolts 5 to 10 mm dia( machine made) with hexagonal or square heads at oneend and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut , n exc 5 cm long complete all as specified . |
| 60 | Expanded metal n .exc 4 ks/sqm, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9 mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified. |
| 61 | S&F for Mild steel work as in tubular trusses including special shaped washer etc. complete using ERW or induction butt weldedtubes conforming to I. S.1161- 1979 grade St.-240 including cutting etc complete all as specified. |
| 62 | M&L for steel gate Ornamental type/Grill work including hold fasts, pintels, stoppers running rails, bushes and all as CI decorative pieces, locking arrangement etc complete all as per design approved and as directed by Engr-in-charge work conforming to Fe-410-O etc complete. |
| 63 | Supply only Chain link MS galvanisd fencing any size or type ( approved by GE)including line wires, any mesh, size and type to any of standards , rails , stainingbolts, etcincluding provision of bindings wire complete all as specified and directed. |
| 64 | Fixing only Chain link MS galvanisd fencing any size or type ( approved by GE)including line wires, any mesh, size and type to any of standards , rails , stainingbolts, etcincluding provision of bindings wire complete all as specified and directed. |
| 65 | M&L two coat of synthetic enamel paint (finishing coat) over one coat of primer to newsteel surfaces of any description over 10 cm width or girth incl prepration of surfaces complete all as specified. |
| 66 | M&L for repair to existing steel rolling shutters by repairing/welding/oiling/greasing to anchoring rod,springs,side guide channel etc incl dismantling existing steel rolling shutters of any width and refixing after making serviceable after adjusting springs complete all as spd and directed. |
| 67 | S&F in repair ball bearing for rolling shutter complete all as specified and directed |
| 68 | S&F in repair springfor rolling shutter complete all as specified and directed |
| 69 | M & L for Machine pressed precast conctete interlocking paver block of any shape and size with gray cement and pigment (Two colour combination) confirming to IS 15658-2006 of 80 mm thick, M-35 Gradelaid dry in floor/pathincluding50 mm thick sand bedding layercomplete all as specified and as directed. |
| 70 | M & L for Machine pressed rubber moulded vibro compacted precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade with Grey cement and pigment over 25 mm thick sand coushioning complete all as specified. |
| 71 | M & L for OUT DOOR coloured ceramic chequeredtiles 8 to 9 mm thick (square/rectangular) area of each tiles exceeding 0.06sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified. |
| 72 | Demolition of cement concrete in ground floors and paving not exceeding 15 cm thickness ( below or above ground level)complete all as specified and directed. |
| 73 | M & L for factory made kerb stone ofM-25 grade cement concretein position to the rtequried line level and curvature jointed with cement mortar 1:3 (1 cement 3 coarse sand)includingmaking joints with or without grooves, (thickness of jointsexcept at sharp curve shall not to more than 5 mm)including drainge opening wherever required ( size and pattern as approved by GE) complete all as spd and directed, |
| 74 | M&L for 40mm thick PCC 1:2:4 type B-1(using 20mm graded stone aggregate as in floor Finishing fair and even without using extra cement complete. |
| 75 | M&L for 75mm thick cement concrete 1:3:6 type C2 using 40mm graded stone aggregate as in floors, plinth protection, Path etc (finished even and fair) laid in panels including joints filled with sealing compound grade \"A\" complete all as directed by Engr-in-Charge |
| 76 | Materials and labour for 75mm thick plain cement concrete (1:4:8) Type D2 using 40mm graded aggregate in sub base of floor complete all as specified and directed. |
| 77 | M & L for applying one coat of synthetic enamel ordinary tint paint on old steel or iron surfaces of any description, over 10cm in width or grith, not otherwise described incl preparation of steel surfaces complete all as specified. |
| 78 | S&F in repair cover suitable for 500lt to 1000 ltrr capacity water storage tank complete all as specified and directed. |
| 79 | S & F Aluminium Composite panel (ACP Sheets colour as approved by GE) of 3/4 mmthick joint with cilicon/ adhesive as per manufacturer instruction including necessary aluminium framed work as required shape and size by welding etcfixing to wall / ceiling/ RCC column/boarding/Gates/Name Plates on gates with necessary fixing arrangements upto a height of 10 Mtrs complete all as specified and as directed. |
| 80 | S & F for 2mm thick fibre glass reinforced translucent plain sheeting with two corrugation side lap fixed with coach screw and washer in roof, wall etc including taking dowown old unserviceable fibre sheet complete all as specified. |
| 81 | S&F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified. |
| 82 | M & L for providing precast cement concrete1:2:4 type B0 using 12.50mm graded aggregate louvres and jallies, 40mm thick (measured solid), including all mouldings but excluding frame (precast frame shall be measured separately) set in CM 1:4 complete all as specified |
| 83 | M&L PCC (1:2:4) type C-1 (20mm graded aggtt) as in kerbs/coping and the like including weathering, slightly rounded or chamfered angles and throating , as directed complete |
| 84 | Excavation in post holes (or similar holes) in soft/loose soil each not exceeding 0.5 cum getting out, returning, filling in ramming earth or broken rubble in layers not exceeding 25 cm, watering and removing of surplus soil to a distance not exc 50m and making good surfaces, complete all as specified and as directed. |
| 85 | M/L for cleaning/de-silting of loose mud, rubbish etc from drain bed including uprooting of vegetative growth throughly and wire brushing including flushing with water so as to achieve smooth flow of water in drain of bed width up to 60 cmand anydepth etc complete all as directed by Engineer in charge. |
| 86 | S & F for wall cladding tiles of size 300mm x 600mmx 8-12mm thick on vertical surfaces of wall , such as skirting, dados , etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match and over 10 mm thick screed bedin CM 1:3 and as per sample approved by GEcomplete all as specified and as directed. |
| 87 | Taking down cement plaster / duster bed PCC of Column, chajja, Parapets of roof, facia, drops etc and making good with cement plaster 10mm thick in CM 1:3 with PCC 1:2:4, (average thickness of PCC 25mm) as required, brushing neat cement slurry with 3.0kg of cement per sq. metreincluding necessary form work and scaffolding upto 2nd floor including fixing of wire netting where required to match the existing surfaces. (Note: The quoted rates are included of steel shuttering and steel scafolding. Wk shall be measured under this item above 4th storeyed bldg only).NOTE: Steel Scafolding / Steel Shuttering/ Jhulla shall be considered included in quoted rates and up to 8 stories bldg against the item). |
| 88 | M&L for providing PMMincluding demolition(Polymer modified cementitious mortar) :-(i) Dry sub strate surface and free of debris & dust(ii) Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible.(In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes).(iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) of 25 mm thickness.Note :Application of PMM shall be preferably be in coats of appx 10mm thickness. PMM work shall be executed in fairely rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use.(iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufactuer complete all as specified and directed. |
| 89 | Providing services on related to welding & black smith work based on day to day complaints on all working days (except Sunday and gazetted Holiday ) from 0900 hours 1700 hours complete all as specified and directed.Note- 1.The above task shall be carried out by deploying minimum 01 welder having black smith skills and 01 Helper on daily basis.2) Necessary T&P, ladders,minor consumable viz welding rods/extras , equipments and safety gear shall be provided by the contractors. 3) All replaceble material shall be issued from MES store. |
| 90 | S&Fin repair Gun metal gate valve with iron wheel head screed both ends for iron pipe and fixed 25 mmm bore complete |
| 91 | S&Fin repair Gun metal gate valve with iron wheel head screed both ends for iron pipe and fixed 40 mmm bore complete |
| 92 | Removal of plant growth by injecting with chemical (glyphosphate solution of 4% concentration) @ 20ml per injection or till refusal by cut stem of plants or roots injected at 30mm distance on the girth. The area shall then be sprayed with25ml (glyphosphate solution 4% concentration) diluted with 1ltr of water. The size of block shall be of 2 Qtrs on each floor and vary in number of floors. All roots of plants shall be removed completely and making good the disturbed surface by plastering and applying two coats of cement based paint or acrylic paint, complete all as specified and as directed.(NOTE: Steel Scafolding / Steel Shuttering/ Jhulla shall be considered included in quoted rates and up to 8 stories bldg against the item). |
| 93 | S & F framed work such as in door frame, door shuters / gate of angel or other sectionwith gusset plates, rails, braces, etc complete , drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hings or steel hanging door fittings,including hings hold fast of Fe 410-W (Gde E-250 quality) etc complete all as specified. |
| 94 | M & L for Washed stone grit plaster on exterior walls in two layers (colour and design as approved by GE), under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square meter, top layer 15 mmwhite cement plaster 1:1/2:2 (1 white cement: 1/2 coarse sand : 2 stone (white) chipping 10mm nominal size) in panels with groove all around as per approved patternincluding scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed(Payment for providing grooves shall be made seprately). |
| 95 | Forminggroove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer -in -Charge |
| 96 | M & L for two coat of floor painton any type of surface including preprationof new/old surface make ;- Indigo floor paint and or equivalent as approved by GE) complete all as specified and directed. |
| 97 | M & L for Demolition of mud in roof, any thickness, including plastering and leaping upto six storey bldg incl necessary scaffolding arrangement complete all as specified and directed (whether full thickness removed or only a part there of) and removing from cantonment area or as directed complete all as directed by Engr in charge and specified. |
| 98 | Dismantling / taking out ofexisting roof treatment with APP membrane of any thickness including taking out existing screed bed / rendering and PCC Paddingof any thicknesswith all necessary arrangements complete all as specified and directed. |
| 99 | Disconnecting existing tanks, ( 500 Ltr) setting aside (or lowering of required) for repairs , cleaning, etc. and hoisting if required reconnecting and refixing in position ( cleaning repairing, etc. measured separately ) comple all as specified and directed. |
| 100 | Disconnecting existing tanks,(1000 ltr) setting aside (or lowering of required) for repairs , cleaning, etc. and hoisting if required reconnecting and refixing in position ( cleaning repairing, etc. measured separately ) comple all as specified and directed. |
| 101 | M&L for cement concrete 1:2:4 type B0 (using 12.50 mm graded stone aggregate) as in levelling coarse over RCC slab to bring the desired slope up to six storied Bldg, using water proofing compound as per manufacturer instruction complete all as specified & directed.Note:- Water proofing compound shall be measured and paid separately. |
| 102 | M&L for APP based polymeric membrane plain finish minimum weighting 3 kg/Sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) over one coat of 85/25 bitumen @1.2 kg/sqm and paste the membrane with torching method and again apply a coat of 85/25 bitumen @ 1.2 kg/sqm at overlapping joints |
| 103 | S & F for Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface up to 3 cuts complete, including providing skirting up to 150 mm height along the parapet walls in the same manner. |
| 104 | Supply and fixing factory made 24 mm thick RAJSHRI/ COBRA\" Brand factory or equivalent made WPC WPC railingcombing WPC board fancy designer type grtingand including WPC frame 100 % solid (wood polymer composite) railing / frame of required length and height2\" x 2.5\" height, comprisingof virgin PVC resinof K value58 - 60 (suspension grade) Calcium carbonate and natural fibres (wood powders/rice husk/wheat husk) and non toxic additives,made from single extrsion process, WPC foam board with having minimumdensity 650 kg/cbm and WPC framehaving minimum density 780 kg/cbm manufactured by\"RAJSHRI\" AN iso 9001-015 certified company having good screw holding capacity minimum comprising of 50N/mm2 Modules of elasticity850N/mm2 and resistance of speed of flae of class A catagory for WPCjali to be fixed with inclWPC frame of size75x50 mm with necessary supporting lengths at vertical as well as horizontalat wallframes to be fixed with 3\"x3\" GI L or SS cleats to support vertical frame length etc incl taking down old RCC jali/railing complete all as spd ans as directed |