| 1 | Excavationin trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and taking outHard/dense-soileomplete all as specified and directed |
| 2 | Returning and filling including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified and directed . |
| 3 | Removing excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specifed and directed . |
| 4 | M&L for PCC 1:3:6 type C2 (using 20 mm graded crushed stone aggregate)filling,in hard standing/ plinth protection, suporttomain raw water supply line and similar work complete all as specified and directed. |
| 5 | M&L for Repair tobroken brick masonry valve pit of approx size 0.75 x 0.75 x 0.75 mtrto 1.1 x 1.1 x 1.1 mtr and remove the old plaster and rendering with CM 1:4including PCC 1:2:4 type B-1 forcopping and providing new MS sheetcover of suitable size.angle iron frame and MS sheet cover two side openwith 2 Nos hinges each side and 2 Nos lifting handle and in built locking arrangement including lock and key prepare surfacewith two coats of synthetic blackpaint over a coats of red oxide primer including necessary excavation in any type of soil, all as specified and directed |
| 6 | M&L for attending underground pipe line leakage complaints of pipe of dia 80 mm to 150 mm upto 0.5 mtr depth line in any type of soil/ hard standing/ under road including earth work/welding work and labour charges complete all as specified and directed by Engr in Charge. Note : any pipe/ pipe fittings/rubber packing/any type of joint required for stop the leakage up to 5 mtr length of pipe included in the same rate. |
| 7 | M&L for attending underground pipe line leakage complaints of pipe of dia 80 mm to 150 mm upto 1 mtr depth line in any type of soil/ hard standing/ under road including earth work/welding work and labour charges complete all as specified and directed by Engr in Charge. Note : any pipe/ pipe fittings/rubber packing/any type of joint required for stop the leakage up to 5 mtr length of pipe included in the same rate. |
| 8 | M&L for attending underground pipe line leakage complaints of pipe of dia 80 mm to 150 mm upto 1.5 mtr depth line in any type of soil/ hard standing/ under road including earth work/welding work and labour charges complete all as specified and directed by Engr in Charge. Note : any pipe/ pipe fittings/rubber packing/any type of joint required for stop the leakage up to 5 mtr length of pipe included in the same rate. |
| 9 | M&L for attending underground pipe line leakage complaints of pipe of dia 80 mm to 150 mm upto 2.0 mtr depth line in any type of soil/ hard standing/ under road including earth work/welding work and labour charges complete all as specified and directed by Engr in Charge. Note : any pipe/ pipe fittings/rubber packing/any type of joint required for stop the leakage up to 5 mtr length of pipe included in the same rate. |
| 10 | M&L for attending underground pipe line leakage complaints of pipe of dia 40 mm to 80 mm upto 0.5 mtr depth line in any type of soil/ hard standing/ under road including earth work/welding work and labour charges complete all as specified and directed by Engr in Charge. Note : any pipe/ pipe fittings/rubber packing/any type of joint required for stop the leakage up to 5 mtr length of pipe included in the same rate. |
| 11 | M&L for attending underground pipe line leakage complaints of pipe of dia 40 mm to 80 mm upto 1.0 mtr depth line in any type of soil/ hard standing/ under road including earth work/welding work and labour charges complete all as specified and directed by Engr in Charge. Note : any pipe/ pipe fittings/rubber packing/any type of joint required for stop the leakage up to 5 mtr length of pipe included in the same rate. |
| 12 | M&L for attending underground pipe line leakage complaints of pipe of dia 40 mm to 80 mm upto 1.5 mtr depth line in any type of soil/ hard standing/ under road including earth work/welding work and labour charges complete all as specified and directed by Engr in Charge. Note : any pipe/ pipe fittings/rubber packing/any type of joint required for stop the leakage up to 5 mtr length of pipe included in the same rate. |
| 13 | M&L for attending underground pipe line leakage complaints of pipe of dia 40 mm to 80 mm upto 2 mtr depth line in any type of soil/ hard standing/ under road including earth work/welding work and labour charges complete all as specified and directed by Engr in Charge. Note : any pipe/ pipe fittings/rubber packing/any type of joint required for stop the leakage up to 5 mtr length of pipe included in the same rate. |
| 14 | M&L for attending underground pipe line leakage complaints of pipe of dia 40 mm to 80 mm upto 2 mtr depth line in any type of soil/ hard standing/ under road including earth work/welding work and labour charges complete all as specified and directed by Engr in Charge. Note : any pipe/ pipe fittings/rubber packing/any type of joint required for stop the leakage up to 5 mtr length of pipe included in the same rate. |
| 15 | M&L for attendingline leakage complaints of rising pipe of dia 40 mm to 50 mm in high rising bldg upto G+15 including suitable size of clamp/welding work and labour charges complete all as specified and directed by Engr in Charge. Note : any fitting such as tee, socket, union , belding work, clamps, reducer of other minor parts included in the quoted rate. Only pipe will be measured and paid separately. |
| 16 | Supply and Fix in repair GI tubing 40 mm bore medium grade, of bldg height upto G+15 including provision of fitting and accessories in trenches/wall/shaft for diversion and improvement in Raw water supply line complete all as specified and directed by Engineer-in-Charge for the following sizes:- |
| 17 | Dittoas per item no 16.00 here in before but 50 mmbore |
| 18 | Dittoas per item no 16.00 here in before but 80 mmbore |
| 19 | Dittoas per item no 16.00 here in before but 100 mmbore |
| 20 | Supply and Fix in repairs 40 mm bore gun metal gate valveISImaked with iron wheel head screwed both ends for GI ppe including fittings ie union socket etc complete all as specified and directed . |
| 21 | Dittoas per item no 20.00 here in before but 50 mmbore |
| 22 | Dittoas per item no 20.00.here in before but 80 mmbore |
| 23 | Supply and Fix in repair sluice valve, 80 mm borecast iron body flanged end drilled and non rinsing type brass spindle with long body, class P N 1.6, conforming to IS 14846of 2000 including flange joint with rubber or fiber board, bolts, nuts and washers complete including pumping out accumulated water all as specified and directed |
| 24 | Dittoas per item no 23 here in before but 100 mmbore |
| 25 | Suply and fix in repair PVC float valve 40 mm bore (ISI marked ) high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwwed for iron pipe and fixed. ( Minimum weight 40mm- 690 Grams 50mm- 830 Grams including necessary GI fittings such as elbow, reducer, nipple etc complete all as specified and directed. |
| 26 | Suply and fix in repair PVC float valve 50 mm bore (ISI marked ) high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwwed for iron pipe and fixed. ( Minimum weight 40mm- 690 Grams 50mm- 830 Grams including necessary GI fittings such as elbow, reducer, nipple etc complete all as specified and directed.- |
| 27 | Taking down old unserviceable PVC water tanks of bldg height upto G+15 of any capacity and Supply and firxingrotational moulded polyethylene water storage tanks of 5000 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position with GI fittings complete all as specified and directed. |
| 28 | Taking down old unserviceable tanks of bldg height upto G+15 of any capacity and Supply and firxingrotational moulded polyethylene water storage tanks of 2000 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position with GI fittings complete all as specified and directed by Engineer-in-Charge. |
| 29 | Taking down old unserviceable tanks any capacitySupply and fix PVC polythene water storage tank lid of any capacity as specified and directed. |
| 30 | Taking down old unserviceable tanks of bldg height upto G+15 of any capacity and Supply and firxingrotational moulded polyethylene water storage tanks of 3000 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed . |
| 31 | Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 32 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete all as specified and directed by Engineer-in-Charge.Make As approved |
| 33 | Earthing complete with galvanized steel earth plate electrode 600x600x6mm burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead strip of 32 x 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC 1:2:4 in pit with pre- cast RCC 1:2:4 cover reinforced with XPM not less than 4 Kg Sqm, test pointetc. all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal to a distance not exc. 50m, testing on completion complete all as specified and directed. |
| 34 | Taking down old/ unsserviceable foot valve from sewage collection tank/ treated water sump Supply and fix new foot valve along with screen filter of size 100 mm as specified and directed |
| 35 | Material and labour for attending Raw water supply complaints and rectification as mentioned below here in afterInternal complaint (in side Room) Including Flush tank Cleaning 2 nosNote for item No35.00 to 39.00(a) Scaffolading if any requiredduring the progress of work the contractor shall provide the same with out any extra cost to the department the rates quoted shall bedeemed inclusive ofthis provision(b) Necessary complaint book shall be provided and maintained by the contractor, complaint slip shallbe deposited very next day in the complaint cell of NOFRA w/s duly signed by the accupant(c) Rates for small fittings and parts are deemed to be included in item rate however pipes, valves, PVC connection shall be measured and paid for separately under relevent items of schedules. |
| 36 | Ditto all as per itmem No 35.00 here in beforebut External complaint upto 4th floor |
| 37 | Ditto all as per itmem No 35.00 here in beforebut External complaint upto 8th floor |
| 38 | Ditto all as per itmem No 35.00 here in beforebut External complaint upto 12th floor |
| 39 | Ditto all as per itmem No 35.00 here in beforebut External complaint upto 16th floor |
| 40 | Supply and fix steel water tubing 25 mm bore galvanised medium grade (ISI Marked) of following size, with all fitting fixed complete to walls and ceilings or laid in floor/wall/ceiling (in high rise building including scafolding) complete all as specified and directed . |
| 41 | Supply and fix steel water tubing 20 mm bore galvanised medium grade (ISI Marked) of following size, with all fitting fixed complete to walls and ceilings or laid in floor/wall/ceiling (in high rise building including scafolding) complete all as specified and directed. |
| 42 | Supply and fix steel water tubing 15 mm boregalvanised medium grade (ISI Marked) of following size, with all fitting fixed complete to walls and ceilings or laid in floor/wall/ceiling (in high rise building including scafolding) complete all as specified and directed. |
| 43 | Supply and fix in repair gun metal gate valve 25 mm bore ISI marked, with iron wheel head, screwed both ends for GI pipe of following sizes, with union, (ISI Marked) fixed in existing line and in position complete all as specified and directed . |
| 44 | Supply and fix in repair gun metal gate valve 20 mm bore ISI marked, with iron wheel head, screwed both ends for GI pipe of following sizes, with union, (ISI Marked) fixed in existing line and in position complete all as specified and directed. |
| 45 | Supply and fix in repair gun metal gate valve 15 mm bore ISI marked, with iron wheel head, screwed both ends for GI pipe of following sizes, with union, (ISI Marked) fixed in existing line and in position complete all as specified and directed. |
| 46 | Supply andfixin repairs angular stop valve cast copper alloy ,screwed down ,high pressure or butterfly handle screwed both ends for iron pipe or for union and fix of size 15 mm bore. |
| 47 | Supply and Fix in repairsPVCValveless, syphonic action type,flushing cistern low level coloured with inlet ball valve \,float and handlre including bracket, fixed in positon complete all as specified and directed . |
| 48 | Supply and fix in repair 450 mm long PVC connectors with brass adapters, washers etc complete all as specified and directed. |
| 49 | Supply and fixin repair concealed stop valve of brass CP 15mm bore complete all as specified and directed Make : as approved |
| 50 | Supply and fixin repair stop valve brass CP15mm bore fixed to pipe lineall as specified and directed. Make : As approved. |
| 51 | M&L for seven stage cleaning and sterilization of inside the RCC/ PVC water storage tank top of the bldg of height upto G+15of capacity 2000 to5000 Ltr of any description and in any position comprising following cleaning and sterilization of water tanksthrough bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY.seven stages are as under plants:-(a). First Stage is to drain out the water by using exit valve or high capacity dewatering system.(b). Second stage is cleaning all the algae formation inside the tank by using TERBAC G10/ Inoxi-60/NB-69 a laboratory tested branded chemical of the company ans scrubbing the walls of the tanks.(c). Third strage is fresh water cleaning by high speed jet pump.(d). Fourth stage and first bacteria screening is decertification by using TERBAC-G5/ Inohor-5/NB-10a Govt Laboratory certified brannded halogen compound.(e). Fifth stage is cleaning the floor of water tank by industrial vaccum cleaner. (f) . Sixth stage is the second bacterio screening and sterilizing method by using ultra violet ray within the tnk and kills all suspended bacteria. (g)Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified, branded strong oxidizing agent TERBAC-G65/Inoxi-60/NB-69 .NOTE:-(i) COMPANY WILL SUBMIT GOVERNMENT LABORATORY TEST CERTIFICATE OF TERBAC-G5/INCHOR-5/NB-10, TERBAC-G65/ INOXIi-60/NB-69, BEFORE CLEANING, FIX THE STICKER MENTIONING THE DATE OF CLEANING & NAME OF SITE AND ALSO PROVIDE CERTIFICATE CONFIRMING THE COMPLETION OF STERILIZATION OF WATER TANKS MENTIONING THE NAME OF STATION AND DATE OF CLEANING. ALL THE CLEANING & STERILIZATION STAFFS SHOULD BE UNDER ACCIDENTAL INSURANCE COVERAGE) (ii) OUTLET PIPE OF OHT SHOULD BE PLUGGED BEFORE CLEANING THE OHT TO AVOID.ENTERING SCALS AND THE SAME SHELL BE RECONNECTED AFTER CLEANING THE OHT AND THE QUOTED RATE IS DEEMED TO INCLUDE FOR THE ROVISION . (III) STERILIZATION TEAM WILL BE COMPRISED OF AT LEAST 30% MEMBERS WHO ARE MINIMUM03 MONTS CERTIFICATE HOLDER IN WATER TANKS STERILIZATION. (IV) CONTRACTOR WILL BE RESPONSIBLE FOR RECTIFICATION OF COMPLAINTS OCCURRED DURING CLEANING THE TANK IE. NO WATER IN TANK/OVER FLOW DUE TO BROKEN OF FLOAT VALVE/ BLOCKAGE TO BE INCLUDED IN QUOTED RATE. NOTE:- THE WORK SHALL BE CARRIED THROUGH SPECILIZED AGENCY RAYS CLEANTECH/ INUS WATERTECH/ SATYA ENTERPRISE. |
| 52 | Material and Labour for cleaning of GI pipes of 50 mm bore by opening of fittings, removing mud, sludge, etcand refixing as stated above for pipes of size in side and outside of the bldg height up to G+15.NOTE:for attending compaints contractor has to arrange one qualified Plumber with one Helper daily report to Complaint Cell for repair/replacement of pipe line including plumbing works, attending complaints of leakage, air lock in pipe line ect (including Sunday & holiday) and rates to be included in Unit Rate. |
| 53 | Material and Labour for cleaning of GI pipes of 40 mm bore by opening of fittings, removing mud, sludge, etcand refixing as stated above for pipes of size in side and outside of the bldg height up to G+15.NOTE:for attending compaints contractor has to arrange one qualified Plumber with one Helper daily report to Complaint Cell for repair/replacement of pipe line including plumbing works, attending complaints of leakage, air lock in pipe line ect (including Sunday & holiday) and rates to be included in Unit Rate. |
| 54 | Material and Labour for cleaning of GI pipes of 25 mm bore by opening of fittings, removing mud, sludge, etcand refixing as stated above for pipes of size in side and outside of the bldg height up to G+15.NOTE:for attending compaints contractor has to arrange one qualified Plumber with one Helper daily report to Complaint Cell for repair/replacement of pipe line including plumbing works, attending complaints of leakage, air lock in pipe line ect (including Sunday & holiday) and rates to be included in Unit Rate. |
| 55 | Material and Labour for cleaning of GI pipes of 20 mm bore by opening of fittings, removing mud, sludge, etcand refixing as stated above for pipes of size in side and outside of the bldg height up to G+15.NOTE:for attending compaints contractor has to arrange one qualified Plumber with one Helper daily report to Complaint Cell for repair/replacement of pipe line including plumbing works, attending complaints of leakage, air lock in pipe line ect (including Sunday & holiday) and rates to be included in Unit Rate. |
| 56 | Material and Labour for cleaning of GI pipes of 15 mm bore by opening of fittings, removing mud, sludge, etcand refixing as stated above for pipes of size in side and outside of the bldg height up to G+15.NOTE:for attending compaints contractor has to arrange one qualified Plumber with one Helper daily report to Complaint Cell for repair/replacement of pipe line including plumbing works, attending complaints of leakage, air lock in pipe line ect (including Sunday & holiday) and rates to be included in Unit Rate. |
| 57 | Supply and fix HDPE material green cloth for open sewage collection and ariation chambers mimimum weight 100 g/m2 complete all as specified and directed . |
| 58 | Material and labour for rewinding the electric motor of capacituy 40 HP TO 60 HPcapacity, disconnecting the electtic connection of motor, earth connections, decoupling motor and pump, removing foundation nuts/bolts and removing the motor from its existing position to workshop (Note:- following workds deemed to be included in the quoted rates.) (a) Removing the split case/body cover of motor, seperate stator/rptar and cutting the complete burnt/defective copper winding.(b) Cleaning the stator body complete by rubbing and paper removal all carbons.(c) Insert insulating materials such as insulating paper sleeves.(d) Rewinding the stator with existing size of super enameled copper winding, varnishing and heaating up at desired temperature for achieve the particular Ohm resistance.(e) Clean the rotor and assembling in motor.(f) Connecting/coupling the motor with pump, connect all electric/earth connection foundation nuts.bolts at its original position and testing on load and complete all as specified and directed. |
| 59 | Material and labour for rewinding the electric motor of capacituy 20 HP to 30 HP capacity, disconnecting the electtic connection of motor, earth connections, decoupling motor and pump, removing foundation nuts/bolts and removing the motor from its existing position to workshop (Note:- following workds deemed to be included in the quoted rates.) (a) Removing the split case/body cover of motor, seperate stator/rptar and cutting the complete burnt/defective copper winding.(b) Cleaning the stator body complete by rubbing and paper removal all carbons.(c) Insert insulating materials such as insulating paper sleeves.(d) Rewinding the stator with existing size of super enameled copper winding, varnishing and heaating up at desired temperature for achieve the particular Ohm resistance.(e) Clean the rotor and assembling in motor.(f) Connecting/coupling the motor with pump, connect all electric/earth connection foundation nuts.bolts at its original position and testing on load and complete all as specified and directed. |
| 60 | M&L for disconnecting the unserviceable centrifugal/ monoblock pump set of capacity 40 0 HPto 60 HP any make fromthe pump foundationafter opening nuts/bolts, transporting from site to workshop, dismantling pump, removing worn out impeller, ball bearing, gasket, and replacene the unserviceable parts , gland packing, greasing, transporting back to pump house and refixing on the existing foundation, connecting the electrilc connection to the motor and testing complete to entire satisfaction of Engineer-in-Charge. |
| 61 | M&L for disconnecting the unserviceable centrifugal/ monoblock pump set of capacity 20 to 30 HP any make fromthe pump foundationafter opening nuts/bolts, transporting from site to workshop, dismantling pump, removing worn out impeller, ball bearing, gasket, and replacene the unserviceable parts , gland packing, greasing, transporting back to pump house and refixing on the existing foundation, connecting the electrilc connection to the motor and testing complete to entire satisfaction of Engineer-in-Charge. |