| 1 | Scarifying or picking gravelled, macadam or bituminous macadam surfaces in area not exc 400 Sqm & depth exc 50mm but not exc 100mm deepand removal of retrieved material from site to a distance not exc 50m complete all as specified and as directed. |
| 2 | M&L for preparing existing black top surfaces by brushing with wire brushes for removing caked mud etc sweeping with broom and and finally fanning the cleaned surface with gunny bags to remove all loose dirt/ dust etc and applying evenly a priming / tack coat with bituminous primer using paving bitumen VG 30 @ 5Kg /10 sqmcomplete all as specified and as directed. |
| 3 | M&L for premixbituminous macadam laid / rolled and compacted to required gradient and camber (consolidated thickness 75mm or less) by using paving bitumen, any penetration @ 4 % by weight of total mixcomplete all as specified and as directed. |
| 4 | M&L for 30 mm thick consolidated thickness bituminous premix semi dense asphaltic concrete with 5.50 % binder content (bitumen of grade VG-30) by weight of total mix,laid by mechanical paver,rolled and compactad to required camber and gradientcomplete all as specified and as directed. |
| 5 | Supply and fixing cat eye solar reflective type of metal body alloy of size 100mm x 100 mm x 20 mm with PAMA striplens reflector of model no DA 972.0 Dark eye or equivalent in Greenlite/Oscar/Siner infrastructure/ 3 Mfixed with and incl MS stud of suitable size as per manufactures instruction complete all as specified and as directed. |
| 6 | M & L for preparing bituminous surfaces of road and marking 2.5mm thick centre lines, stop lines, dashes, arrows etc. and the like n. exc 10cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instructioncomplete all as specified and as directed. |
| 7 | Supply and fixsolar cat eye aluminum alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono rystafie solar panel 2.4V/ 0.3 watt one NI-ed rechargeable battery (1.2V/ 1600MA) consisting of super bright LED with 10,000 to 18,000 mcd completed as per manufactures instructions etc complete all as specified and as directed. |
| 8 | Supply and fixing metal tubular dealineator made out of ABS round body fitted with 2 Nos 65 mm dia highly reflective reflectors made out of PMMA and mounted on 45/50 mm dia mild steel pipe of 600 mm height duly powder coated and thermo plastic elastomer 3 bands of green, red and yellow reflector radium tape of 25 mm wide strips with anti theft steel net for reflector protection including embedding in PCC 1:2:4 (150x150x300mm) type B1complete all as specified and as directed. |
| 9 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided forcomplete all as specified and as directed. |
| 10 | M&L providing precast cement concrete in cover slab (for manhole) type B1 1:2:4 (20mm graded aggregate) set in CM 1:4complete all as specified and as directed. |
| 11 | M&L MS TMTbars 10 mm dia and over cut to length, bend to shape etc complete binding with and including mild steel annealed wire not less than 0.09 mm dia conforming TMT barscomplete all as specified and as directed. |
| 12 | Manufacturing, supplying and fixing retro reflective Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm and made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawingcomplete all as specified and as directed. |
| 13 | Dismantling Stone slabs laid dry and tiles of any description or thickness in floors, aprons etc. and rubbish off the premisescomplete all as specified and as directed. |
| 14 | Demolition cement Concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 15 | M&L 75mm thick PCC type D-2, 1:4:8 (40mm aggregate) in floor as sub base complete all as specified and as directed. |
| 16 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed. |
| 17 | M&L Providing and laying at or near ground level factory made kerb stone of M-25 gradeement concrete in position to the required line, level and curvature, jointed withement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever requiredcomplete all as specified and as directed. |
| 18 | Providing, cement concrete Type B1, 1:2:4 (20mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed. |