| 1 | Excavation in trenches not exceeding 1.5 metre wide and not exc 1.5 metre in depth for foundation of pole/stay, or cable trenches, etc. n. exc. 10 Sqm on plan and getting out in soft/loose soil, complete all as specified and directed. |
| 2 | Returning filling in incl spreading, leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed. |
| 3 | Removing of excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point in any type of soil, complete all as specified and directed. |
| 4 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size16 sqmm 4 core, complete all as specified and directed. |
| 5 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size25 sqmm 3.5 core, complete all as specified and directed. |
| 6 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size35 sqmm 3.5 core, complete all as specified and directed. |
| 7 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size70 sqmm 3.5 core, complete all as specified and directed. |
| 8 | Supply and laying double walled corrugated (DWC) HDPE duct pipe of 40mm dia (outer) conformingto IS, approved colour, complete with fittings for cable protection, complete all as specified and directed. |
| 9 | S & F junction box made from SMC/FRP sheet ready made of size 370 x 270 x 210mm with aluminium bus bar of 100 Amp capacity for RYB and for neutral made in suitable size fixed inside the junction box with necessary supporting insulators, fixed on hylem sheet, MS sheet steel, fixed inside the bottom portion of box to connect the cable gland complete, entire assembly fixed to pole/wall with MS clamp 25 x 5mm and nuts & bolts, or inside the copping of pole/post top including MCB SP 6 Amp 10 KA \"C\" series 240 V - 1 No, with suitable size copper lugs for connecting cables from junction box to fittings, complete all as specified and dirtected. |
| 10 | Supply & installation of octagonal steel poles 8m HOT DIP galvanised, as per IS 4759 : 1996 / IS 2629 : 1985 including 1200mm in built double armed bracket, 3mm section thickness, top dia 70mm, bottom dia 135mm, base plate 225 x 225 x 16mm and its accessories, system including PCC foundation & foundation bolts as per OEM recommendation, complete all as specified and directed.Note : Cost of PCC foundation shall deemed to be included in the unit quoted rate. |
| 11 | S&F LED street light fittings 70 watt, made of pressure dia cast aluminium housing with system efficiency greater than 120 lumen per watt and BIS approved silicon filled potted driver for vibration proof, 4 KV in-built driver and 10 KV surge protection inside housing, IP 66 protection including 70 watt LED lamp, complete all as specified and directed. |
| 12 | Supply, fabrication, installation, testing and commissioning of outdoor type LT feeder pillar box of size 1000(H) x 900(W) x 400(D)mm, factory fabricated, wall/floor mounted double door, dust and vermin proof CPRI approved inner parts made of 2.00mm thick CRCA sheetand outer shell of 3.15mm thick CRCA sheet, having rain canopy type, four side slop top, suported on 50 x 50 x 6mm angle iron base frame and legs of 500mm height, painted with texured powder coated paint of thickness not less than 100 micron, after preparation of surface in 8 tanks sheet process system with aluminium bus bar & strips of size 200 Amp all outgoing switchgears shall have extended strips or extended wire with terminals for easy and comfortable outgoing connection, front and back apenable including locking arrangement including suitable size copper conductor control wiring, necessary cable glands, lugs etc, proper arrangement for ventilation with and including the following accessories :-INCOMING:(i) MCCB 100 Amps, AC, 4 pole 415 Volt, 25 KA Breaking Capacity, thermal magnetic release range 100A, with suitable rotary extendable handle for operation of MCCB-01 No.(ii) CT\"s 500 /5 Amp - Set of three.(iii) Digital multi function Meter 0- 500 Volt (4405 series) - 01 No.(iv) RYB Indicating lamps -03 Nos.(v) MCB SP 6 Amp \"C\" curve, 10 KA - 03 Nos.OUTGOING:(i) MCCB 63 Amps, AC, 4 pole, 415 Volt, 36 KA Breaking Capacity thermal magnetic release range 63A, with suitable rotary extendable handle for operation - 03 Nos.(iii) Astro time switch- 02 Nos.(iv) 3 pole power contactors type MNX - 02 Nos.(v) Auto manual selector switch -02 Nos.(vi) Terminal 4 pole 63A- 03 Nos. |
| 13 | M&L for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping of poles etc including formwork (as required), complete all as specified and directed. |
| 14 | & L for power cable route marker pre-cast RCC of size 1500mm x 300mm x 50mm with top curved portion, 8mm dia round bar reinforcement, emboshing of letter (MES-POWER CABLE) both faces of pre-cast during casting of RCC precast, applying two coats of exterior emulsion paint over a coat of primer, approved colour and painting of emboshed surface with exterior emulsion black paint including earth work for fixing of route marker, complete all as specified and directed. |
| 15 | M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6.0mm thick buried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of earth plate at a depth not less than 1.5 meter below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized earth lead wire 4mm thick dia by means of bolts, nuts and washers of galvanized iron or steel and thimbles and other end of the earth wire connected to earthing test point/equipment and protected by galvanized iron pipe light grade 20mm bore, up to earthing test point/equipment fixed with required number of mild steel clamp made out of 25mm x 3mm flat iron and perforated water pipe 20mm bore. GI medium grade and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC earth pit chamber in PCC (1:2:4) type B-1 and CI cover with frame, excavation & earth work, all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009, including testing on completion, complete all as specified and directed. |
| 16 | Horizontal boring under the road (with manual method) below 1mtr from the road surface and dia of hole not exc. 100mm, without damaging the existing road, getting out and disposal of materials to a distance not exceeding 50m from the site of work, complete all as specified and directed. |
| 17 | S&F in repair LT danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20 x 15cm size, complete all as specified and directed. |
| 18 | S & F 3 core PVC insulated unsheathed multistranded copper conductor cable (FR) of size 1.5 Sqmm for voltage grade upto 1100 V, passing through PVC conduit from junction box to fittings, complete all as specified and directed. |
| 19 | M & L for flame proof point wiring surface/concealed type with 4 Sqmm (nominal cross sectional area) with PVC insulated unsheathed single core stranded copper conductor Zero Halogen Flame Retardant (ZHFR/HFFR) cable of working voltage upto 1100 volts grade conforming to IS-17048 drawn in and including steel surface conduit with all fittings & accessories such as FLP flexible conduit, FLP junction box, brass glands/connector, bends etc. with 1.60mm thick pressed steel or mild steel sheet sunk box, including 4 Sqmm (nominal cross sectional area) PVC insulated unsheathed single core stranded copper conductor (ZHFR/HFFR) cable as earth continuity conductor connected to main switch/ \"DB\"s or common earth dolly for one 16 Amps power socket, complete all as specified and directed. |
| 20 | M & L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 4 Sqmm (nominal area) FRLSH type multi stranded copper conductor, single core drawn in and including 20/25mm PVC casing caping (ISI marked), heavy duty of adequate size including its accessories including pressed steel terminal box of required size, factory made, with top cover of ISI marked plastic laminated sheet of required colour for mounting switch, sockets etc including 4 Sqmm FRLSH type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site and making good disturbed surface & applying finishes to match existing surface, for one 16 Amp switch socket combination, complete all as specified and directed. |
| 21 | M & L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 1.5 Sqmm (nominal area) FRLSH type multi stranded copper conductor, single core drawn in and including concealed, rigid PVC conduit (ISI marked) not less than 20mm dia, heavy duty, including all conduit accessories with and including concealed pressed steel terminal box of suitable size, factory made, with top cover of ISI marked plastic laminated sheet of required colour for mounting switch, sockets, fan regulator, etc including 1.5 Sqmm FRLSH type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site including chase cutting & making good disturbed surface & applying finishes to match existing surface etc. for one light/fan point controlled by one, one way switch single pole, complete all as specified and directed.Note : Provision of blanking plates, as per site requirement shall deemed to be included in the unit quoted rate. |
| 22 | All as per item No 21.00 here-in before but for 3 pin 5 Amp socket point on independent board, complete all as specified and directed. |
| 23 | All as per item No 21.00 here-in before but with 4.0 Sqmm PVC insulated unsheathed multi stranded cable FRLSH type for one 15 Amp 3 pin socket outlet point including PVC insulated 4.0 Sqmm FRLSHtype copper multi stranded conductor as earth wire, complete all as specified and directed. |
| 24 | M & L flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2 Pin + earth (3 Pin) having full proof interlocking i.e plug can\"t be removed in ON condition, complete all as specified and directed. |
| 25 | M & L for removing cerefully 5/15 Amp sockets with switches and deposited to E/M store yard, filling the space with blanking plates, making good to distrubed surfaces, complete all as specified and directed. |
| 26 | M & L for removing cerefully ceiling fan with regulators and switches and deposited to EM store yard and filling the space with blanking plates, making good to distrubed surfaces, complete all as specified and directed. |
| 27 | M & L for flame proof junction box 4 way, 100mm dia with plain cover 3/4\" ET, complete all as specified and directed. |
| 28 | M & L for heavy duty flame proof flexible metalic hose conduit of 20mm dia and 300mm long alongwith proper brass glands at both end, complete all as specified and directed. |
| 29 | S&F plug top, 15/16 Amps, complete all as specified and directed. |
| 30 | S&F switch and socket combination with junction box, 2 in 1, 5 pin, 6 Amp / 16 Amp, flush type, complete all as specified and directed. |
| 31 | S&F switch and socket combination2 in 1, 6 Ampflush type, complete all as specified and directed. |
| 32 | S&F switch and socket combination 3 pin, 16 Amp, flush type, complete all as specified and directed. |
| 33 | S&F ceiling rose PVC / Polycarbonate, isolated body, 3 phase including PVC mounting block white/ivory finish, complete all as specified and directed. |
| 34 | S&F MCB distribution board (DB), SPN with sheet metal encloser, double door, IP 43 protection & IK 09, 240 volts, 12 way, as per IEC 61439-3 with necessary lugs for incomming and outgong connections, fixed on wall,single pole andneutral, with 200 Amps rated busbar (as per OEM), neutral link for fixing MCBs/Isolators, complete all as specified and directed. |
| 35 | S&F MCB Single Pole (SP) of capacity 6 to 32 Amps, 240 Volts, breaking capacity 10 KA, ‘B’ curve, as per IS/IEC 60898-1, fixedin proper position, complete all as specified and directed. |
| 36 | S&F MCB Single Pole & Neutral (SPN) of capacity 6 to 32 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, as per IS/IEC 60898-1, fixedin proper position, complete all as specified and directed. |
| 37 | S&F MCB four pole of capacity 63 Amps, 10 KA, \"C\" series, as per IS/IEC 60898-1, fixedin proper position, complete all as specified and directed. |
| 38 | S & F flexible PVC insulated unsheathed multistranded copper conductor cable of size 4.0 Sqmm (FRLSH) for voltage grade upto 1100 V, complete as specified and directed. |
| 39 | M & L for submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor cable 6 Sqmm 1100 Volts grade, Zero Halogen Flame Retardant (ZHFR/HFFR) type, including 6 Sqmm (ZHFR/HFFR) type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire drawn in and including stove enamelled steel conduit of size 20mm bore, heavy duty, including fixing accessories and connecting to common earth terminals, complete all as specified and directed.Note :- Three runs of cables and one run of steel conduit including its accessories shall be measured as one length. |
| 40 | M&L for submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor cable 1.5 Sqmm, 1100Volts grade, FRLSH type, drawn in and including heavy duty rigid PVC concealed conduit (ISI marked) not less than 20mm dia with fixing accessories including 1.5 Sqmm 1100 Volts grade, FRLSH type, PVC insulated unsheathed multistranded flexible copper conductor cable as continuous earth wire and connecting to common earth dolly, complete all as specified and directed.Note: (i) Three runs of cable including PVC conduit shall be measured and paid as one length.(ii) Cutting chases for conduit, sinking of boxes and making good to wall, floors etc shall deemed to be including in the unit quoted rate. |
| 41 | Supply and fixing energy efficient ‘LED Flood Light120 W LED luminairewith Aluminium dia cast housing, toughened glass cover with IP 66 protection, CCT 5700 K including fixing arrangment on wall/pole / surface and connecting cable up to nearest ceilign rose into flexible PVC conduit. Make : Crompton/Havells/ Surya/Philips |