| 1 | Taking out/bailing out the sludge/semi solid materials/contaminated water including other foreign materials from manholes of various sizes and up to depth n.exc 1.5 m by mechanical means and taking out sludge/semi solid materials/ any other foreign materials from manholes etc and removing the sludge within 50 m distance and deposited in pit to be excavated and covered with earth filling up to 30 cm depth of pit including removing and re fixing of manholes covers as required and spreading of bleaching powder to disinfect the area cleaned, complete all as specified and directed.(Note: (i) the cost of excavation and earth work for pit, temporary barricade of the pit and providing sufficient bleaching sufficient bleaching powder shall deem to be included in the unit quoted rate.(ii) Hiring charges and cost of fuel for sewage pump shall deemed to be included in the unit quoted rate and nothing extra shall be paid in this account) |
| 2 | Taking out/bailing out the sludge/semi solid materials/contaminated water including other foreign materials E from manholes of various sizes and up to depth exc 1.5m n.exc 3.0m by mechanical means and taking out sludge/semi solid materials/ any other foreign materials from manholes etc and removing the sludge within 50m distance and deposited in pit to be excavated and covered with earth filling up to 30cm depth of pit including removing and re-fixing of manholes covers as required and spreading of bleaching powder to disinfect the area cleaned. complete all as specified and directed.(Note: (i) the cost of excavation and earth work for pit, temporary barricade of the pit and providing sufficient bleaching sufficient bleaching powder shall deem to be included in the unit quoted rate.(ii) Hiring charges and cost of fuel for sewage pump shall deemed to be included in the unit quoted rate and nothing extra shall be paid in this account) |
| 3 | Cleaning of blockage in sewage lines / drain pipes of the internal dia 100mm/150mm/200mm by Roding or by any other suitable means and cleaning the entire line and well flushing between the manholes complete all as specified and directed by Engineer in Charge. |
| 4 | De-watering/Bailing out of contaminated/sewage water including other foreign materials from septic tanks/manholes/soakage wells of any dia and any depth by mechanical eqpt means using mono-block/sewage pump etc after plugging of incoming sewage lines and throwing/removing contaminated/sewage water into low laying non-residential area or into drains/nallah or removed outside MoD land and spreading un-slacked lime to disinfect the area cleaned, complete all as directed by Engineer in charge.Note: (a) Carry out the job with all safety precautions.(b) The rate includes removing and re-fixing of Manhole covers |
| 5 | Cleaning of blocked WC\"s and soil pipes of any dia up to first manhole by Roding or by any other means and well flushing with water the entire line after cleaning complete all as directed by Engineer - in - Charge. |
| 6 | Cleaning of blocked Floor/gully/nahani trap in bathroom/kitchen/wash basin etc and soil waste pipe of any Ea dia up to gully traps by using rubber hand pump or Roding and opening the eye and making the line clear for smooth function complete all as specified and directed. |
| 7 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for foundation, etc, and getting out in soft/loose soil complete all as specified and directed. |
| 8 | Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m but n.exc. 3 m deep for foundation, etc, and getting out in soft/loose soil complete all as specified and directed. |
| 9 | Removing excavated soils to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 10 | Returning filling in including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and directed. |
| 11 | Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required for 100 mm dia of pipe complete all as specified and directed. |
| 12 | Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required for 150 mm dia of pipe complete all as specified and directed. |
| 13 | Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required for 200 mm dia of pipe complete all as specified and directed. |
| 14 | Demolition and breaking up 100 mm dia drain pipes (Salt glazed ware, AC or reinforced concrete set in cement mortar, separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 m and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 m as directed by the Engineer-in-Charge. |
| 15 | Demolition and breaking up 150 mm dia drain pipes (Salt glazed ware, AC or reinforced concrete set in cement mortar, separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 m and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 m as directed by the Engineer-in-Charge. |
| 16 | Demolition and breaking up 200 mm dia drain pipes (Salt glazed ware, AC or reinforced concrete set in cement mortar, separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 m and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 m as directed by the Engineer-in-Charge. |
| 17 | M & L for PCC (1:3:6), type C 2. (using 40 mm graded stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 100 mm bore of pipe complete all as specified and directed. |
| 18 | M & L for PCC (1:3:6), type C 2, (using 40 mm graded stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore of pipe complete all as specified and directed. |
| 19 | M & L for PCC (1:3:6), type C 2, (using 40 mm graded stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200 mm bore of pipe complete all as specified and directed. |
| 20 | M & L for 100 mm dia Salt Glazed stone ware drain pipes, grade \"A\", laid in trenches and jointed in cement mortar and tested complete all as specified and directed. |
| 21 | M & L for 150 mm dia Salt Glazed stone ware drain pipes, grade \"A\", laid in trenches and jointed in cement mortar and tested complete all as specified and directed. |
| 22 | M & L for 200 mm dia Salt Glazed stone ware drain pipes, grade \"A\", laid in trenches and jointed in cement mortar and tested complete all as specified and directed. |
| 23 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc.. separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 m and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 m as directed by the Engineer in Charge. |
| 24 | M & L for brick work with sub-class \"B\" bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar (1:4) complete all as specified and directed. |
| 25 | M & L plain cement concrete type B-0 (1:2:4) (using 12.5 mm graded stone aggregate) cast in situ in copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work complete all as specified and directed. |
| 26 | Taking down cement plaster on brick or stone walls, etc, including raking out joints, hacking for key. scrubbing down with water, etc complete all as specified and directed. |
| 27 | M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) and S finished even and smooth without using extra cement including mixing of water proofing compound wherever required as per manufacturers instructions (WPC shall be measured & paid separately). |
| 28 | M & L for Preparing newly plastered surfaces of walls and applying three coats of white wash including preparation of surfaces complete all as specified and directed. |
| 29 | Supply only integral water proofing compound of approved quality. (Make- CICCO NO.1/SIKA/ACCO PROOF). |
| 30 | Demolition of reinforced cement Concrete of any description and in any position disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 m as directed by the Engineer in Charge. (Reinforcement shall be cut as required to facilitate demolition). |
| 31 | S&F in repair factory made (SFRC) precast reinforced cement concrete manhole cover as required, thickness not less than 100 mm for heavy duty and dia of manhole cover not less than 630mm, edge of manhole cover to be locked with 1mm thick MS sheet complete all as specified and as directed. |
| 32 | S&F in repair factory made (SFRC) precast reinforced cement concrete manhole cover as required, thickness not less than 60 mm of size 700x550mm, edge of manhole cover to be locked with 1mm thick MS sheet complete all as specified and as directed. |
| 33 | S&F in repair factory made (SFRC) precast reinforced cement concrete manhole cover as required, thickness not less than 60 mm of size 900x450mm, edge of manhole cover to be locked with 1mm thick MS sheet complete all as specified and as directed. |
| 34 | S&F in repair factory made (SFRC) precast reinforced cement concrete manhole cover as required, thickness not less than 60 mm of size 350x350mm, edge of manhole cover to be locked with 1mm thick MS sheet complete all as specified and as directed. |
| 35 | S & F CP grating 100 mm dia with or without hole as directed by Engr-in-Charge complete all as specified E and directed. |
| 36 | S & F CP grating 125 mm dia with waste hole of PTMT (Minimum weight 40 grams) complete all as specified and directed. |
| 37 | S & F in repairs, vitreous China squatting pan, \"Orissa\" pattern, size 580mm x 440 mm, white with integral foot rest and \"P\" or \"S\" trap, including provision of lime concrete bedding, connection to trap and flushing pipe and vitreous vhina foot rest etc complete including making good to disturbed surfaces of floor to match with existing specifications as specified. |
| 38 | S & F in repair Vitreous china wash down water closet (Pedestal), white (EWC) including Plastic seat of same colour of WC, closed patttern with flat bottom, and cover and Mild steel chromium plated hinging device complete. |
| 39 | S&F in repairs vitreous china one peice wash down water closet pan (padestal pattern) including P/S trap and soft close seat cover with hinging device and CP jet spray with hanging device all necessary work required for fixed in position complete all as specified and directed. |
| 40 | S&F in repairs, 10 litres capacity PVC valveless syphonic action type, flushing cistern (ISI marked), low level with inlet, ball valve, float bracket & flush pipe complete all as specified & directed. |
| 41 | S&F in repair 32mm Bottle trap of PTMT for WHB/Kitchen sink etc.. having minimum water seal of 25mm (Minimum weight 32mm-260gms/40mm-270 gms) complete all as specified and directed. |
| 42 | S&F in repair 40mm Bottle trap of PTMT for WHB/Kitchen sink etc. having minimum water seal of 25mm (Minimum weight 32mm-260gms/40mm-270 gms) complete all as specified and directed. |
| 43 | S & F in repair Vitreous China wash basin, white, flat back, size 630 x 450mm including cutting for and pinning in ends of brackets or erecting stand inclusive connection of water supply along with pillar tap and waste pipe complete all as specified and directed. |
| 44 | Taking down soil/waste/vent and rain water pipes including all fittings of any size and pattern in any position complete all as specified and directed. |
| 45 | S&F 50mm bore low density polyethylene pipes (LDPE) of pressure rating 6 kgf/Sqcm fixed complete to walls, cellings or in floors etc. complete all as specified and directed. |
| 46 | S&F 50mm bore low density polyethylene pipes (LDPE) of pressure rating 6 kgf/Sqcm laid (concealed) in trenches after Cutting chases, pinning in and making good to facings where required and pointing in CM (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc; and cutting chases for concealed water tubing, for drain/spouts pipes or other purposes for waste water etc., and making good, cutting not exc 10 cm girth to concrete surfaces/walls.ceilings or in floors/sunken floors etc, complete all as specified and directed. |
| 47 | S & F 75 mm dia, PVC SWR pipes, single socketed, in any length with sealant rubber ring joints fixed to wall including necessary nails, plugs and holder bats etc all as specified and as directed by the Engineer-in-Charge. |
| 48 | S & F 75 mm dia, PVC SWR pipes, single socketed, in any length with sealant rubber ring joints laid in trenches or in floor (concealed) after Cutting chases, pinning in and making good to facings where required and pointing in CM (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing, for drain/spouts pipes or other purposes for waste water etc., and making good, cutting not exc 10 cm girth to concrete surfaces/walls, ceilings or in floors/sunken floors etc, complete all as specified and directedincluding necessary nails, plugs and holder bats etc all as specified and as directed by the Engineer - in - Charge. |
| 49 | S & F 110 mm dia, PVC SWR pipes, single socketed, in any length with sealant rubber ring joints fixed to wall including necessary clamps all as specified and as directed by the Engineer-in-Charge. |
| 50 | Fixing only 110 mm bore PVC pipes in any length with rubber ring joints fixed to walls with necessary nails, plugs and holder bats etc (Pipes shall be obtained from taking down). |
| 51 | S&F 75 mm bore, PVC (SWR) bends of any radius complete all as specified and directed. |
| 52 | S&F in repair 75 mm bore, PVC (SWR) bends provided with access door of any radius complete all as specified and directed |
| 53 | S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed. |
| 54 | S & F 110 mm bore PVC (SWR) bends of any radius with access door complete all as specified and directed. |
| 55 | S&F PVC (SWR) junction, single, (single T) equal or unequal 110mm bore complete all as specified and directed |
| 56 | S&F PVC (SWR) junction, single, (single T) equal or unequal 75mm bore complete all as specified and directed |
| 57 | S&F PVC (SWR) 100mm branch piece, single (single Y) equal or unequalcomplete all as specified and directed |
| 58 | S&F PVC (SWR) 100mm branch piece, double (double Y) equal or unequalcomplete all as specified and directed. |
| 59 | S&F PVC (SWR) 75mm branch piece, single (single Y) equal or unequalcomplete all as specified and directed |
| 60 | S&F PVC (SWR) 75mm branch piece, double (double Y) equal or unequalcomplete all as specified and directed. |
| 61 | S&F in repairs, PVC (SWR) 75 mm dia, floor trap, plain grating with/without hole including jointing to waste pipe with solvent cement complete all as specified and directed. |
| 62 | M&L for PVC(SWR) gully trap 125/110mm, setting and jointing with solvent cement all as specified and as directed by the Engineer-in-Charge |
| 63 | Taking down 20mm bore steel water tubing and connection from wall /ceiling surfaces including cleaning for re-fixing or removing from site of work complete all as specified and as directed. |
| 64 | S&F steel water tubing and connection medium grade 20mm bore with all fitting fixed to wall or in ceiling complete all as specified and as directed. |
| 65 | Re-fixing old steel tubing and connection 20mm bore in new or old position complete on wall/ceiling complete all as specified and as directed. |
| 66 | Taking down 15mm bore steel water tubing and connection from wall /ceiling surfaces including cleaning for re-fixing or removing from site of work complete all as specified and as directed. |
| 67 | Re-fixing old steel tubing and connection 15mm bore in new or old position complete on wall/ceiling complete all as specified and as directed. |
| 68 | S&F steel water tubing and connection medium grade 15mm bore with all fitting fixed concealed to wall or in ceiling complete and making good surfaces with cement morter 1:3.exc 10 cm girth |
| 69 | S&F steel water tubing and connection medium grade 15mm bore with all fitting fixed to wall or in ceiling complete all as specified and as directed. |
| 70 | S&F in repairs, flush pipe of polyethylene of low or high density or PVC. 32mm dia, for low level flushing cisterns all as specified. |
| 71 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backin), removing serviceable tiles to store and rubbish off the premises complete as specified and directed. |
| 72 | M & L for coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 18 sqm, in floors etc. set and jointed in neat cement slurry and pointed with white cement and pigment to match over and including 15mm thick screed bed of cement mortar (1:6) complete as specified and directed. |
| 73 | M&L for providing glazed ceramic coloured tiles in vertical surface (450mm x 350mm/300mm X 450mm) X6 to 7mm thick set and jointed neat cement slurry and pointed in white or coloured cement to match including rendering 10mm thick in CM 1:4 as backing coat to receive wall tiles complete as specified and |
| 74 | Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 75 | M&L for 75 mm thick cement concrete type D2, (1:4:8) using 40mm graded stone aggregates as sub base to floor, complete all as specified and directed. |
| 76 | M&L for Machine cut kota stone slab flooring 18-20mm thick of size not less than 0.30 Sqm of each slab over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with and including 15mm thick screed bed or bedding in cement mortar (1:6) complete all as specified and directed. (Note: Single piece tiles will be placed on the surface of stair case tread area). |
| 77 | M&L for Kota stone slab 15mm thick in riser of bricks steps & riser of staircase skirting, dado and pillar laid over cement screed and jointed with pigment to match the shade of the slab including rubbing and polishing with & including backing coat in 10mm thick CM (1:3) to receive Kota Stone complete all as specified and directed (Note: Single piece tiles will be placed on the surface of stair case riser area). |
| 78 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 79 | M&L for Machine pressed precast conctete coloured interlocking paver block any shape and size fixed with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickness M-35 grade complete all as specified and directed. |
| 80 | M&L for coloured chequred tiles, glossy finish, 25cm x 25cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement & pigment, laid over & including 15mm thick screed bed in cement & sand mortar (1:4), complete, all as specified & as directed. |
| 81 | M & L plain cement concrete type B-0 (1:2:4) (using 12.5 mm graded stone aggregate) cast in situ in copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work complete all as specified and directed. |