| Sl. No. | Item Description |
| 1 | M&L for preparation of plastered or unplastered old decorated surfaces by complete removal of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7\"/9\" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible , filling of holes and cracks with with suitable material like cement or plaster of paris etcand thereafter applying two coat of oil bound distemper over a coat of primer on walls/ceiling including applying 1-2mm thick wall care putty over disturbed surface complete all as specified and as directed. Note : (a) Each stage of complete removal of existing treatment and preparation of surfaces after applying putty shall be got approved from Engg-In-Charge in stage passing register before applying the finishes coat.(b) Material shall be procured from manufacturer and work shall be got executed through authorised applicators of manufacturer. |
| 2 | M&L for preparation(complete removal of existing treatment) of old decorated external wall/ceiling surface of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7\"/9\" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying Two coats of wheather proofing exterior acrylic emulsion paint over a coat of primer premium quality on wall/ceiling surface including applying 1-2mm thick wall care putty over disturbed surface during preparation of any reason, sand papering thus make surface smooth upto 4th storey buildings complete all as specified and as directed.Note : (a) Each stage of complete removal of existing treatment and preparation of surfaces after applying putty shall be got approved from Engg-In-Charge in stage passing register before applying the finishes coat.(b) Material shall be procured from manufacturer and work shall be got executed through authorised applicators of manufacturer. |
| 3 | M&L for preparation of old treated plastered or unplastered surfaces of walls including cornices by brooming down or steel wire brushing, scraping down, smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spot, filling cracks/holes with puttyand applying one coat of distemper oil emulsion on walls complete . |
| 4 | M&L for preparation of old treated plastered or unplastered surfaces of ceiling including cornices by brooming down or steel wire brushing, scraping down, smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spot, filling cracks/holes with puttyand applying one coat of distemper oil emulsion on ceiling complete . |
| 5 | Taking down cement plaster or cement lime plasteron brick,concrete or stone surfacesincluding raking out joints, hacking for key, scrubbing down with water etc complete all as specified |
| 6 | M&Lfor 5 mm thick cementplaster on fair faces of brick work or concrete surfaces in cement mortar 1:3 in ceiling includingfinishingsurface even and smooth without using extra cement. |
| 7 | M&L for 10 mm thick cementplaster on fair faces of brick work or concrete surfaces in cement mortar 1:6 on walls includingfinishingsurface even and smooth without using extra cement |
| 8 | M&L for 15 mm thick plaster in cement mortar (1:4) on brick or concrete surfaces including rendering on fins, fascias, chajja, parapets etc and finishing the surfaces even and fair (without using extra cement) complete all as specified. |
| 9 | M&L for preparation ofnewly plastered surface of wall and applying two coats of oil bound distemper over one coat of primer complete all as specified. |
| 10 | M&L for preparation ofnewly plastered surface of ceiling and applying two coats of oil bound distemper over one coat of primer complete all as specified |
| 11 | M&L for preparation ofnewly plastered surface of wall and applying Two coats of wheather proofing exterior acrylic emulsion paint over a coat of primer premium quality complete all as specified |
| 12 | M&L for providing 3mm thick wall care putty on wall before applying oil bound distemper and making the surface uniform all as specified. |
| 13 | M&L for providing 3mm thick wall care putty on ceiling before applying oil bound distemper and making the surface uniform all as specified. |
| 14 | M&L for preparing of old surfaces and applying one coats of plastic emulsion paint (royal shyne/equvalent) , complete all as specifed and directed by engr -in charge |
| 15 | M & L for preparing old surfaces and applying one coat of floor tile guard paint as approved complete all as specified and as directed. |
| 16 | M & L for applying Bees-Wax polishing over granite stone flooring including removing dust/sweeping all as specified. |
| 17 | M & L for applying one coat of French polishing on surfaces of any description, width or girth including filling the dents / holes with filler and applying one coat of sealer and touchup with french polish incl cleaning, preparing the surface of old wooden surfaces and all as specified and directed by Engr-in-Charge. |
| 18 | M & L for preparation of old painted cement concrete surfaces applying one coat of synthetic enamel paint complete all as specified and directed Engr-in-Charge. |
| 19 | Taking up or down steel tubing and connections 15mm dia pipes including cleaning for refixing or removal to store complete all as specified and as directed. |
| 20 | Taking up or down steel tubing and connections 20mm dia pipes including cleaning for refixing or removal to store complete all as specified and as directed. |
| 21 | S & F 15mm dia tubes medium grade, galvanized, with all fittings such as sockets, bends, elbows, tees etc, concealed/surface fixed to walls and ceiling or laid in floors complete all as specified and directed. |
| 22 | S & F 20 mm dia tubes medium grade, galvanized, with all fittings such as sockets, bends, elbows, tees etc, concealed/surface fixed to walls and ceiling or laid in floors complete all as specified and directed. |
| 23 | Cutting chases, pinning in brick walls, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves, lintels, etc; and cuttings chases for concealed water tubing or concealed conduit wiring, etc and making good, cutting not exceeding 10 cm girth all as specified and directed |
| 24 | Disconnecting existing PVC water tank of capacity exc. 250 ltr but not exc. 500 ltr, setting aside for lowering down if required for repairs,hoisting if required reconnecting and refixing in position on roof including cleaning of Overhead tank & removing the sludge washing down with detergent/ bleaching powder and writing the date of cleaning with suitable paint complete all as specified. |
| 25 | Dismantling of existing water tanks of steel/PVC/AC of capacity exceeding 250 liters but not exceeding 500 litres complete all as specified. |
| 26 | Dismantling water tanks of capacity exceeding 500 and not exceeding 1000 ltrs all as specified and directed by Engineer - in - Charge. |
| 27 | S&F for rotational moulded polyethylene water storage tanks 500 ltrs capacity (cylinderical verticalwith closed top) hoisted and fixed in position all as per SSR Part I complete all as specified. |
| 28 | S & F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I of capacity 1000 Litres all as specified and directed by Engineer - in - Charge . |
| 29 | S&F in repairball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball with minimum weight 210 gm screwed for 20mm bore dia iron pipe supplied and fixed in repairs complete all as specified and as directed. |
| 30 | S&F in repair for 20mm dia gun metal gate valve, with iron wheel head, screwed both ends for iron pipes complete all as directed. |
| 31 | S&F in repair vitreous chinaCounter top Wash hand basin (White) of size (570x420x195 mm) mm complete all as specified. (Cat No. FLS-WHT-5601) Make: Jaquar/Equivalent |
| 32 | S&F in repair vitreous china Rimless Single Piece WC (White) With PP Soft Close Slim Seat Cover, Hinges, Dual Flush Cistern Fittings, Fixing Accessories And Accessories Set, Size: 370x690x750 mm, S Trap- 300 mm complete all as specified. (Cat No.CNS-WHT-853S300SPPSM) Make: Jaquar/Equivalent |
| 33 | S & F in repairs Vitreous China Half stall urinal of size 380x405x509mmWhite complete including providing CP waste coupling and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement complete . Make parryware, Jaquar / Cera / Eqvlt |
| 34 | S & Fin repairs of sensors assembly for auto flush urinal code EFS N-PCB(DC)Assy new ,parryware make or equivalent and making good all as specified and directedby Engr-in-Charge. |
| 35 | S & Fin repairs of sensors of valve assembly for auto flush urinal code SMART EFS SOLENOID VALVE Assy,parryware make or equivalent and making good all as specified and directedby Engr-in-Charge. |
| 36 | S & Fin repairs of sensors of power assembly for auto flush urinal code C741199 Assypower sourse for SMART HAWNE TAP A/C ,parryware make or equivalent and making good all as specified and directedby Engr-in-Charge. |
| 37 | S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 mtr long flexible tube and ABS wall hook including making connections and mixed in position complete all as specified and directed. |
| 38 | S&F in repair Toilet paper holder with flat recessed type stainless steel complete all as specified. |
| 39 | S & Fin repairs PVC connection 15mm size with PTMT nuts of length 450mm all as specified and directed. |
| 40 | S & F in repair brass CP Wall mixer with L bend incl (provn for over head shower), 15 mm bore chromium plated fancy type for mixing hot & coldwater screwed down for iron pipe complete all as specified and directed (Cat Part No F2002401 Cera or equivelent) |
| 41 | S&F Single Lever 3-inlet Diverter Exposed parts kit chrome finish consisting of Operating Lever, Cartridge Sleeve, Wall Flange (with Seals), Button Assembly Sleeve and Button Cap , 15 mm nominal bore complete (Cat No.OPP-CHR-15193NKPM) Make: Jaquar/Equivalent |
| 42 | S & Fin repair brass CP kitchen sink mixer for mixing hot & coldwater screwed down for iron pipe, 15mm dia chromium plated fancy type complete all as specified and directed |
| 43 | S&F in repair Exposed Part Kit of Single Lever Basin Mixer Wall Mounted chrome finish consisting of Operating Lever, Cartridge Sleeve, Wall Flange, Nipple & Spout 15 mm nominal bore(Cat No.ARI-CHR-39233NK) Make: Jaquar/Equivalent |
| 44 | S&F in repair 32 mm dia brass chromium plated bottle traps for wash basins with inlet and outletscrewed for pipe or connectionsincludingnecessary packing, unionand cap and fixed complete all as specified. |
| 45 | S&F in repair angular two way angle cock with wall flange, 15 mm bore cast copper alloy, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified. |
| 46 | S & F in repairs bib taps, long body cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down, screwed for 15 mm bore iron pipe or for brass ferrule complete all as specified. |
| 47 | S & F in repairs 15mm dia stop valves/angle valve, cast copper alloy, chromium plated, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for 15 mm bore iron pipe or for brass ferrule complete all as specified. |
| 48 | S & F in repairs chromium plated shower rose 125mm sizeincl shower arm casted 190 mm long flat shape for wall mounted showers with flangeinclfixing to steel pipe or union all as specified and directed. |
| 49 | S&F in repair Soap dish of chromium plated or stainless steel fixed to wall with chromium plated brass screws all as specified and directed |
| 50 | S & F in repairs 600 x 450 mm size beveled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood and fixed with wooden plugs with chromium plated brass screws and cup washers all as specified and directed. |
| 51 | S&F in repair Corner glass shelf, 5mm thick glass, 9\" wide, fixed with suitablemild steel CP brackets, nuts & bolts all as specified and as directed.Make:Onida/ High Life/ Eagle |
| 52 | S & F in repair Brass chromium plated, tubular towel rails 20 mm dia, D- type, 60 cm long between flanges, completed all as specified and directed. |
| 53 | S & F in repairs stainless steel sinks with drainage board made out of 1.00 mm thick sheet for kitchen with plugs, washers, waste pipes, including bedding in cement mortar to dwarf wall or including fixing cast iron cantilever brackets and connecting union to pipe overall size915 mm x 460 mm with bowl size 410mm x 330mm x 160mm, with and including PVC waste pipe and CP waste coupling 32 mm dia and making good to disturbed surfaces, fixed in repairs, complete all as specified. |
| 54 | S&F in repairs SFRC manhole cover of size 600mm x 600mm x 70mm thick with frame set in cement mortar 1:4 complete all as specified and as directed. Notes: - (i) Make of SFRC Manhole/drain cover and frame : (a) M/s PS Concrete. (b) M/s KK Manhole.(c) Or equivalent as approved by GE (ii) Contractor will provide manufacturer test certificate of SFRC cover & frame |
| 55 | S&F in repairs SFRC cover slabs of size 450mm x 450mm x 40mm thick with frame set in cement mortar 1:4 complete all as specified and as directed. Notes-(i) Make of SFRC Manhole/drain cover and frame :(a) M/s PS Concrete (b) M/s KK Manhole.(c) Or equivalent as approved by GE (ii) Contractor will provide manufacturer test certificate of SFRC cover & frame |
| 56 | M&L in repairs for 12 mm thickprelaminatedparticle board, interior graded, preliminated one side withdecorative choice lamination and other side balancing white laminations, aluminium/ tibmer frame and wall surface all as specified and directed. |
| 57 | M&L fixed in repairsfor 12 mm thickprelaminatedboth side , interior graded, preliminated both sidedecorative choice lamination fixed to aluminium/ tibmer frame and wall surface all as specified and directed. |
| 58 | M&L in repairs for 09 mm thickprelaminatedparticle board, interior graded, preliminated one side withdecorative choice lamination and other side balancing white laminations, fixed to aluminium/ tibmer frame wall surface all as specified and directed. |
| 59 | M&L in repairs for 09 mm thickprelaminatedparticle board, interior graded, preliminated both side withdecorative choice laminationfixed to aluminium/ tibmer frame wall surface all as specified and directed. |
| 60 | M&L in repairs for 12 mm Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face (One Side Teak) fixed with screws to timber frame as directed. |
| 61 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittinges, heads, shoes, bends, swan-necks etc as specified. |
| 62 | S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls/trenches complete all as specified & directed. |
| 63 | S & F 150 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls/trenches complete all as specified & directed. |
| 64 | S & F in repair 110 mm bore PVC (SWR) bends with/without door of any radius complete all as specified & directed. |
| 65 | S & Fin repair 110 mm bore PVC (SWR) junctionsingle, (single T), equal or unequal with/without door of any radius complete all as specified & directed. |
| 66 | S & F in repair 150 mm bore PVC (SWR) bends of any radius complete all as specified & directed. |
| 67 | S & F in repair 150 mm bore PVC (SWR) junction single, (single T), equal or unequal with/without door of any radius complete all as specified & directed. |
| 68 | Dismantling galvalume sheet (corrugated ,semi corrugated etc) in roof coverings incl ridges etc complete. |
| 69 | S&F for Fibre glass reinforced coloured translucent semi-corrugated sheeting 2mm thick with two corrugations side lap fixed with coach screw and washer in roof, wall etc. |
| 70 | Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the permises complete all as specified and as directed |
| 71 | M&L for nonskid coloured ceramic tiles 7mm thick areaof each tiles exeeding 0.11 sqm but not exceeding 0.18 sqm in floors/skirting etc. set and jointed neat cemet slury and pointed in coloured cement to match complete all as specified and as directed. (Notes : Screed bed measured and paid separately) |
| 72 | M&L for double chargedVitrifiedCeramic tiles 9-10 mm thick (Square/rectangular) oflight Shade , polished, area of each tile exceeding 0.36 sqm and n. exc 0.72 sqm and , fixed in floor/skirting etc overset and jointed in neatcement slurry and pointed in coloured cement to match with coloured tiles complete all as specified. |
| 73 | M&L for ColouredVitrifiedCeramic tiles 9-10 mm thick (Square/rectangular) ofLight Shade , polished, area of each tilenot exceeding 0.36 sqm, fixed in floor/skirting etc overset and jointed in neatcement slurry and pointed in coloured cement to match with coloured tiles complete all as specified. |
| 74 | M & L for glazed ceramic coloured tiles of size 450X 350X 7mm/ 600x300x7 mmthick as in vertical surfaces, set and jointed in neat cement slurry and pointed in white or coloured cement to match of tiles, complete all as specified and directed. |
| 75 | Demolition of stone slabs andtiles of any description or thickness in floors/walls, aprons etc laid bedded and pointed in any mortar. |
| 76 | M&L 20-25mm thick machine cut kota stone slab as in flooring, steps of stair(treads), over cement screed base laid and jointed withgrey cement slurry mixed with pigment to match the sahde of the slab including rubbing and polishing incl complete all as specified and as directed. |
| 77 | M&L 20-25 mm thick machine kota stone slab as in skirting/dado, riser of steps, laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and directed. |
| 78 | M&L for 18-20 mm thick Granite tiles machine cut , bedded and jointed with grey cements slurry and pointed with white or colour cement with admixture of pigment to match the shade of granite stone including grinding & polishing slab over screed bed or bedding layer of mortar 15 mm thick in cement mortar (1 : 4)laid complete all as specified. |
| 79 | M&L for screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:6)for bedding of tilescomplete all as specified. |
| 80 | M&L for 10 mm thick rendering in cement motar (1:4) on vertical surface for bracking of tiles etccomplete all as specified. |
| 81 | M&L for screed bed or bedding layer of mortar 20 mm thick in cement mortar (1:6)for bedding of tilescomplete all as specified. |
| 82 | M&L for 15 mm thick rendering in cement motar (1:4) on vertical surface for bracking of tiles etccomplete all as specified. |
| 83 | Demolition of cement concrete (unreinforced) of any description including cast-in-situ terrazzo (below or above ground level), not exc. 15 cm thickness, including removal of rubbish outside MoD land, complete all as specified. |
| 84 | M&L for 25mm thick plain cement concrete type B-1 (1:2:4) using 20mm gradedstone aggregate as in sub base all as specified and directed. |
| 85 | M&L for 40mm thick plain cement concrete type B-1 (1:2:4) using 20mm gradedstone aggregate as in sub base all as specified and directed. |
| 86 | M&L for 100 mm thick Cement concrete type C1, 1:3:6 (using 40 mm gradedaggregate) infoothpaths andhard standingfinish even and fair without using extra cement complete all as specified and directed. |
| 87 | Taking down shutters of any description not exceeding 1 Sq. m each, from chowkhat, complete all as specified |
| 88 | Taking down shutters of any description exceeding 1 Sq. m but not exceeding 2 Sq. m each, from chowkhat, complete all as specified |
| 89 | Taking down Chowkhats with shutters without taking of shutter from the frame of any description not exceeding 1.50 Sq. m each, complete all as specified |
| 90 | Taking down Chowkhats with shutters without taking of shutter from the frame of any description exceeding 1.50 Sq. m but not exceeding 4.00 Sq. m each, and making good the disturbed Surface in CM1:4 & finished with similar specification as exists, complete all as specified |
| 91 | S&F Pressed steel frames of size 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., with and including back filling with PCC (1:3:6), type C-0, complete as specified and as directed. |
| 92 | S&F flush shutters 30 mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as specified and as directed. |
| 93 | S & FFactory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge),minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.(Note: stainless steel butt hinges and necessary S Sscrews shall be paid separately) |
| 94 | Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 100 x 50 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance tospread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction ofEngineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid forseparately). →Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensionson plus side shall be acceptable but no extra payment on this account shall be made.ccomplete all as specified and as directed . |
| 95 | S&F powder coated anodized aluminum frame for partition, doors, windows, ventilations with one or more rebates including joining cleat for fixing etc. complete all as specified. |
| 96 | S&F powder coated anodized aluminum door shutters, aluminum section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing handles 2 Nos in each door,100 mm longhinges (3 Nos), anodized aluminum snap beading screws etc. complete all as specified. |
| 97 | S&F powder coated Anodised aluminium window and ventilator shutters, fixed/side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified. |
| 98 | S&F Powder coated aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge. |
| 99 | M & L for PCC (1:3:6) type C-1 (using20 mm graded stone aggregate) as in padding, coping, bed plates, hold fast blocks,etc., including formwork, weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed. |
| 100 | M&L Cement concrete 1:3:6 type C–1 (using 20 mm graded stone aggregate) as in filling of pressed steel door frame and hold fast blocks etc all as specified and directed. |
| 101 | S&F Mild steel butt hinges medium weight, cold rolled, 100 mm, ISI marked, complete all as specified. |
| 102 | S&F 150mm long aluminium anodized, barrel tower bolt of extruded sectioncomplete. |
| 103 | S&F 200 mm aluminium anodized, barrel tower bolts of extruded section. |
| 104 | S&F 150mm size aluminum handle fabricated, \"D\"type, anodized ISI marked complete all as specified and directed. |
| 105 | S&F in repair 150 mm long, Aluminum anodised floor door stopper alloy body and tounge, anodised, with hard drawn steel spring fixed in floor in repairs complete as specified and as directed. |
| 106 | S&F in repair for aluminium (Die cast) body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified. |
| 107 | S & Fin repair brass mortice lock vertical type size 100 /150mm 4/6 levers all as specified and directed by Engr-in-Charge |
| 108 | S & F in repairsof 600mm long stainless steel handle quality of SS 304 Grade fixed to glass door for fixed in posn all as specified and directed. |
| 109 | S & F in repairs on toughned glass,door/partion 10mm thick including making holes in glass and all assesories for fixed in posn all as specified and directed. |
| 110 | Dismantling of wrought iron of mild steel work of any description in any position not otherwise specifically provided for all as specified. |
| 111 | S & F Rolled Mild Steel Plates (plain or Chequered) channels, square cut or notched, forming holes, without any attachment confirming to Fe 410-S complete all as specified. |
| 112 | S&F in repair false ceiling with exposed GI system using “SILHOUETTE XL 15 mm (Nominal) designer Grid \"Armstrong\"white or Global white with black reveal and 600 x 600 x 15 mm thick prime fine fissured micro look white/coloured tiles (superfine 15mm/silhouette). Making necessary framework for AC ducting, if any and necessary cutouts for diffusers and light fittings, taping and finishing to proper line & level and incl dismantling old undervicable false ceillingcomplete all as per manufacturer’s instructions and as directed. |
| 113 | Dismantling/removingold damaged worn out APP of any thicknessincl screed bed or plastering of anythickness and removing the rubish materials outside MOD land at a dumping place earmarked marked by any state govt/municipalities etc any distance complete. |
| 114 | M&L for 40 mm thick PCC (1:2:4) type B-0 (using 12.50 mm graded stone aggregate) as in roof padding, sub base of floor copingcomplete all as specified and directed. |
| 115 | Material and labour 15 mm thickscreed bedin CM (1:4) mixed with WPC as per manufacturer’s instructions @ 3% by wt of cementon fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured and paid separately. |
| 116 | Supply onlyWater Proofing compound complete all as directed. Make : Dr. Fixit |
| 117 | Material and labour, water proofing treatment of roof consisting as under:- (a) Applyinga tack coat of industrial bitumen 85/25 at the rate of 1.20 kg per sqm over a coat of primer @ 0.30 litre/ sq.m including preparation of roof surfaces (b) A layer of 3mm thick APP polymeric membrane of weight not less than 3.60 kg/sqm, reinforced with polyester non-woven fabric (weight not less than 160gm/sqm), duly sealed at over laps & joints with flame (by torch application) all as per manufacturer’s instructions complete all as specified and directed. |
| 118 | M & L for preparation of new painted surfaces of wood and wood based materials of any description not other wise described over 10 cm width or girth and applying Two coat of synthetic enamel paint over a pink primer coat complete all as specified and directed |
| 119 | M&L Preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamelled paint over one coat of red oxide primer. |
| 120 | S&FStainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple including necessary beading complete all as specified. |
| 121 | S&Ffor 4.8/5.0 mm thick sheet glass ordinary quality and glazingeach pane n exc 0.50 Sqm fixed with neoprenerubber gasket in aluminium frame work complete all as specified. |
| 122 | E&M ITEMS |
| 123 | Takingdown carefully copper / aluminium point wiring light / fan, socket or power point complete including fittings such as switches, sockets, ceiling rose, bell push bell buzzer lamp holder bracket etc. removing from site and making good disturbed surface of wall, floor etc complete all as specified and as directed. |
| 124 | M&L for replacement of point wiring in casing caping on sufraces of wall/ceiling floor etc complete with PVC insulated and unsheathedFRLS cable of 1.5 sqmm (nominal area) with multistranded copper conductor single core 1100 volts grade with PVC rectangular block of suitable size including 1.5 sqmm multistranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etccomplete all as specified and as directed for the followings :- |
| 125 | One light / fan point controlled by one way switch |
| 126 | One 5 Amps socket out let point controlled by one 1-way switch on independent board. |
| 127 | One 5 Amps socket out let point controlled by one 1-way switch on same board. |
| 128 | All as per above item no 124 here in befor but using 2.5sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for15 Amp socket outleton independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified andas directed. |
| 129 | S&F in replacement switch piano type 5 amp one way 240 volts AC 50 hz ISI Marked complete all as specified and directed by Engineer-in-Charge. |
| 130 | S&Fin replacement switch piano type15 Amps one way 240 volts AC 50 hz ISI Marked complete all as specified and directed by Engineer-in-Charge. |
| 131 | S&F in replacement socket outlet 5 pin 5 Amps 240 volts AC 50 hz ISI marked flush type complete all as specified and directed by Engineer-in-Charge. |
| 132 | S&F in replacement socket outlet 2-in-1, 6 pin 5 amp and 15 amps 240 volts AC 50 hz ISI marked all as specified and directed. |
| 133 | S&F in replacement socket outlet 6A-2/3 Pin combined 2 module 240 volts AC 50 hz ISI markedmodular type complete all as specified and directed. |
| 134 | S&F in replacement socket outlet 6A/16A-2/3 pin combined 2 module 240 volts AC 50 hz ISI markedmodular type complete all as specified and directed. |
| 135 | S&F in replacement switch 6 amps modular type one one way 240 volts AC 50 hz ISI marked complete all as directed. |
| 136 | S&F in replacement switch 16 amps modular type one one way 240 volts AC 50 hz marked complete all as directed. |
| 137 | S&F in replacement electronic fan regulator Step type complete all as specified and directed. |
| 138 | S&F in replacement bell push flush type 5 amp one way 240 volts AC 50 hz ISI Marked complete all as specified and directed. |
| 139 | S&F in replacement modular type bell push 6 amp one module 240 volt ISI marked complete all as specified and directed. |
| 140 | S&F in replacementBell, DING DONG AC 230 Volts single pole type complete all as specified and asdirected. |
| 141 | S & F in replacement ofLamp holder bakalite type with back plate suitable for batten fittingscomplete all as specified as directed |
| 142 | S&F in replacement of ceiling rose surface bakelite 63 x50mm three terminals completeall as specified and asdirected. |
| 143 | S & F in replacement of sub main wiring with PVC insulated, FRLS unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4.0 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of4.0 sqmm multistranded copper conductorsingle core PVC insulated, unsheathed cable of green colouras continuous earth wire including lugs etcconnected and tested complete all as specified and as directed.Note:(i) Two runs of 4.0 sqmm cable and one run of 4.0 sqmm cable of earth continuity conductor and conduit shall be a unit length. |
| 144 | S & F in replacement ofsub main wiring with PVC insulated, FRLS, unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 6.0 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directedwith and including one run of6.0 sqmm multistranded copper conductorsingle core PVC insulated, unsheathed cable of green colouras continuous earth wire including lugs etcconnected and tested complete all as specified and as directed.Note:(i) Two runs of 6.0 sqmm cable and one run of 6.0sqmm cable of earth continuity conductor and conduit shall be a unit length.Common Note For Item No- 143 & 144-(i) if the contractor fail to make good the disturbed surface of wall and do not match with existing surface of wall to the entire satisfaction of Engr-in-Charge a recovery of Rs 50 per RM shall be made from payment due to contractor. |
| 145 | S&F in replacement of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 12 ways 240 V including fixing in new location with connection of circuit and submain as per site requirement complete all as specified and as directed . Note- (a) MCBs are to be measured and paid seperately. (b)Make ofMCBs and DB should be same.(c) Extra circuit length where DBs are to be shifted from existing location to new location shall deemed to be included in the quoted rate. Make-Havells/Indoasian/Legrand, |
| 146 | S&F in replacement of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 8 ways 240 V including fixing in new location with connection of circuit and submain as per site requirement complete all as specified and as directed . Note- (a) MCBs are to be measured and paid seperately. (b)Make ofMCBs and DB should be same.(c) Extra circuit length where DBs are to be shifted from existing location to new location shall deemed to be included in the quoted rate. Make-Havells/Indoasian/Legrand, |
| 147 | S&F in replacement of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 4 ways 240 V including fixing in new location with connection of circuit and submain as per site requirement complete all as specified and as directed . Note- (a) MCBs are to be measured and paid seperately. (b)Make ofMCBs and DB should be same.(c) Extra circuit length where DBs are to be shifted from existing location to new location shall deemed to be included in the quoted rate. Make-Havells/ Indoasian/Legrand, |
| 148 | S&F in replacement of single pole and neutral enclosure with 2 pin and metal earth plug and socket complete with one single pole MCB 25 Amp complete all as specified and as directed.Make-Havells/Indoasian/Legrand |
| 149 | S&F in replacement MCB SP 6 to 32 Amps,240 volts curve \"B\",breaking capacity 10KA,all as specified. |
| 150 | S&F in replacement MCB SPN16 to 40 Amps,240 volts,curve \"B\", breaking capacity 10 KA, all as specified. |
| 151 | S&F in replacement MCB SPN40 to 63 Amps,240 volts,curve \"C\", breaking capacity 10 KA, all as specified. |
| 152 | S&F in replacement MCB TPN40 to 100 Amps,415 volts,curve \"B\", breaking capacity 10 KA, all as specified. |
| 153 | S&F in replacement MCCB , 125 Amps, 4Pole with adjustable thermal magnetic release type setting knob and rupturing capacity 16 kA complete all as specified and directed. |
| 154 | S & F In replacement ofmodular switch 2 way, 6 Amp,1 module ISI Marked complete all as specified and asdirected. |
| 155 | S & F in replacement ofmodular Fan Regulator fan step regulator,120W- single module ISI Marked complete all as specified as as directed. |
| 156 | S & F In replacement ofPiano type switch 2 way, 5 Amp,1 module ISI Marked complete all as specified and asdirected. |
| 157 | S&F inmodular blanking plate, 1 module ISI Marked complete all as specified and as directed. |
| 158 | S&F in replacement metal flush box 3 module all as specified and directed. |
| 159 | S&F in replacement metal flush box 6 module all as specified and directed. |
| 160 | S&F in replacement metal flush box 8 module all as specified and directed. |
| 161 | S&F in replacement for white cover plate with frame, 3 module all as specified and directed. |
| 162 | S&F in replacement for white cover plate with frame, 6 module all as specified and directed. |
| 163 | S&F in replacement for white cover plate with frame, 8 module all as specified and directed. |
| 164 | Supply and fixing in repair ofEarthing to DBs with galvanised steel earth plate electrode60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 4.0 sqmm galvanised iron wire by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead shall be protected by GI pipe 15 mm dia medium grade and connected to distribution board includingexcavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and as directed.Note- cost of 7.5 RM of GI wire shall be included in quoted rate |
| 165 | M & L in repair for Earth continuity conductor or main earthing lead of 4.0 Sqmm galvanized iron wire, buried in ground or fixed to wall in and including 15 mm bore GI pipe medium grade for protection of earth wire complete all as specified and directed. |
| 166 | S&F in replacementenviroment friendly,ultra modern,energy saving surface mounted decorative 12 Watt LED bulkhead fitting PC housing ,high efficient LEDs with opal diffuser and IP65 protectio, lumen efficacy 85 lm/watt with colour temerature 3500K/6500K as per site requirement, THD≤20 CRI>80,2.5 kV surge protection all as specified and directed. Make- Surya/crompton/Jaquar |
| 167 | S&F in replacement of enviroment friendly indoor decorative 20 Watt LED polycarbonate Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessaries all as specified and directed. Make- Surya/crompton/Jaquar |
| 168 | S&F in replacement of enviroment friendly indoor decorative 9/10 Watt LED polycarbonate Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessaries all as specified and directed. Make- Surya/crompton/Jaquar |
| 169 | S & F in replacement enviroment friendly recess/pendent/Surface mounting as required at site 36 watt LED flat panel 2\"x2\" fabricated CRCA sheet steel duly powder coated housing cool white with high efficient LEDs & glare free opal diffuser PF>0.95 , lumen efficacy>100 lm/W, THD<10% operating range 220v to 240V,CRI>80 including connection with existing wire and all accessaries all as specified and directed. Make- Surya/Halonix/orient |
| 170 | M&L for fixing PVC gang box for mounting one switch and one socket of 5 Amps including all accessoriese complete all as specifies and directed. |
| 171 | M&L for fixing PVC gang box for mounting one switch and one socket of 15 Amps including all accessoriese complete all as specifies and directed. |
| 172 | Supply and fixing of PVC Casing capping 20/25mm ISI marked all as specified and as directed by Engineer-in-charge. |
| 173 | S&F in replacement of Cable PVC insulated unsheathed singlecore 1100V FRLS grade stranded flexible copper conductor of size 1.5 sqmm complete all as specified and directed. Make:- Finolex/Havells/Grandlay |
| 174 | Supply and fixing in replacement of Cable PVC insulated unsheathed singlecore 1100V FRLS grade stranded flexible copper conductor of size 2.5 sqmm complete all as specified and directed. Make:- Finolex/Havells/Grandlay |
| 175 | Supply and fixing in replacement of Cable PVC insulated unsheathed twin core of 23/0.0076 size flexible copper conductor complete all as specified and directed. |
| 176 | Supply and fixing in replacement of Cable PVC insulated unarmoured threecore 1100V FRLS grade stranded flexible copper conductor of size 2.5 sqmm complete all as specified and directed. Make:- Finolex/Havells/Grandlay |
| 177 | Supply and fixing 25 mtr long 2.5 cm wide and atleast .125 mm wall thickness self adhesive PVC insulated electrical tape roll of good quality complete all as specified and directed. |
| 178 | Taking down light fittings of any type any size any location complete all as specifed and directed. |
| 179 | Taking down DB including old U/s MCB/MCCB of any size any type from any location complete all as specifed and directed. |
| 180 | Supply & fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)complete all as specified and as directed by Engr-in-Charge. Make- Orient/Crompton/Havells |
| 181 | Supply & fixingexhaust fan, steel body AC single Phase. 230V of size 300 mm sweep double bearing with, 1400 RPM, blades, and frame and louver complete all as specified and as directed by Engr-in-Charge. Make- Orient/Crompton/Havells |
| 182 | Supply & fixing wall mounting fans 230 volts single phase oscillating 400 mm sweep suitable for wall mountingcomplete all as specified and as directed by Engr-in-Charge. Make- Orient/Crompton/Bajaj |
| 183 | supply & fixing plastic body ventilation fan 250 mmas required 50 Hz , 240 volt 1250 RPM with copper wound motor including all fixing accessories complete all as specified and directed.Make- Orient/Crompton/Havells |
| 184 | supply and fixing plastic body ventilation fan 200 mmas required 50 Hz , 240 volt 1250 RPM with copper wound motor including all fixing accessories complete all as specified and directed.Make- Orient/Crompton/Havells |
| 185 | S & F in replacement of sub main wiring with PVC insulated, FRLS unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 2.5 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of2.5 sqmm multistranded copper conductorsingle core PVC insulated, unsheathed cable of green colouras continuous earth wire including lugs etcconnected and tested complete all as specified and as directed.Note: (i) Two runs of 2.5sqmm cable and one run of 2.5 sqmm cable of earth continuity conductor and conduit shall be a unit length. |
| 186 | S & F in replacement of sub main wiring with PVC insulated, FRLS unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 1.5 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of1.5 sqmm multistranded copper conductorsingle core PVC insulated, unsheathed cable of green colouras continuous earth wire including lugs etcconnected and tested complete all as specified and as directed.Note:(i) Two runs of 1.5 sqmm cable and one run of 1.5 sqmm cable of earth continuity conductor and conduit shall be a unit length. |
| 187 | M&L for Carry out \"B\" check from authorised rep or service engineer from the manufacturer of DG set of 200 KVA,capacityMake : Cummins (including the cost of the following sparesall as per OEM instructions and directed) :-(a) S & F in repair lubrication oil filter(b) S & F in repair by pass filter(c) Checking of hydraulic governer (d) Checking and toping up of coolant (e) S & F in repair fuel filter(f) S & F in repair air cleaner element . (g) Cleaning radiator complete set(h) S&F Engine Oil as required as per capacity |
| 188 | S&F Solenoied switch sutaible for 200 KVA DG Set complete all as specified and as directed. |
| 189 | S&F of Ring gear of Flywheel suitable for DG set up to 200 KVA complete all as specified and as directed. |
| 190 | S&F in replacement of AVR S/F VARIABLE SPEED DCDGsuitable for DG set with input voltage range 415 Volt AC with neutral & Out put DC voltage suitable for DG set of 200 KVA complete all as specified and as directed. |
| 191 | M&L for disconnected and opening of self starter assemlly 12/24 volt for repair from DG set up to 200 KVA & repair unserveceable part of self starter suitable size as required on sitecomplete all as specified and as directed.Note :- Rate are deemed tobe include all worn out part including gear & winding complete all as specified |
| 192 | Supply only the following items of DG Set of various capacity:- |
| 193 | Battery terminal, lug, bolts type suitable for heavy duty battery complete all as specified and as directed. |
| 194 | Battery leads for copper conductor multiwired 70 Sqmm Single Core complete all as specified and as directed. |
| 195 | Hinges for DG set door of any size, any type as required on site complete all as specified and as directed. |
| 196 | M&L for Dismantling existing U/S battery charger & S/F of SMPS type battery charger suitable for 12 V DC with auto cut off from trickle to boost alongwith AC lead to charge the battery when DG Set is not in use complete all as specified and as directed. |
| 197 | S&F V belt for fan pulley (set of 2 Nos) for DG set upto 200 KVA DG Set complete all as specified and as directed. |
| 198 | S&F V belt for alternator and water pump assembly for DG set upto 200 KVA complete all as specified and as directed. |
| 199 | S&F Fuel hose pipe from fuel filter to fuel pump for DG set upto 200 KVA, complete all as specified and as directed. |
| 200 | S&F Fuel pipe from fuel tank to fuel filterfor DG set upto 200 KVA, complete all as specified and as directed. |
| 201 | Labour for attendingofanybreakdown of standby supply in any location ,whenever required round the clock ,rectify the fault and restore the standby supply within three hour after receipt of complaint of any nature i.e. Engine, alternator,control panel, AMF panel etc complete all as specified and as directed. Note -(i) The cost ofreplaced spare parts will be paid and measured seperatly.(ii)If complaint is not attended by contractorwith in five hour the penality of Rs 500 / per hourto be imposed and amount of penality will be deducted from RAR. (iii) Thecost of transportation (to and fro) for all kind ofnecessary equipment / T&P shall be arranged/brought by contractor to complete the job at site or at E/M yard and no extra cost shall be paid to the contractor to this effect. (iv) Complaint shall be lodged by telephonically ,so contractor to specifythe telephone no who willreceive the complaint round the clock. |
| 202 | M&L for opening / taking out of injector of DG set of any type/make and capacity200 KVA disconnection and opening of fuel injector assembly, carrying complete overhauling/servicing fuel injection system with including replacement of injector repair kit ,including calibration of injector, checking of pressure complete for each injector and re-assembling the same, fitted with DG set properly in original location, checking the allignment, making properfuel connection, testing for smooth opreatio complete all as specified and as directed. |
| 203 | S&F in replacement of unsv thermostat with new thermostat alongwith complete assy for DG set connection testing complete all as specified and as directed. |
| 204 | M&L for complete overhauling,servicing of turbo charger, opening /taking out of turbo charger of DG set of 200KVA capacity ,disconnection of air supplyconnection pipe etc, including replacement of turbo charger repair kit, calibration/ testing of turbo charger system complete and re-assembling the same ,fitted with DG set properly in original position, checking the allignment, making proper all connection, testing for smooth opreation from authorised rep or service engineer from the manufacturer complete all as specified and as directed. |
| 205 | M&L for capacity 200 KVA DG set complete descaling of cooling system by radiwash with two times circulation of radiwash by means of running of engine & cleaning of fan blades, crankcase breather, radiator and its fins by means of high pressure air or water complete all as specified and as directed. |
| 206 | M&L for Dehydration including filtration and cleaning of Transformer oil by dehydrating machine incl testing of sample before and after dehydration and filtration and replacement of silica gel complete all as specified and as directed.NOTE:- Contractor hasto arrange the dehydration machine and testing kit withoutany extra cost to the dept. Test report to be submitted after completion of job. (Transformer 415 KVA) |
| 207 | Supply & Filling /pouring of up to the appropriate level Transformer oil of low viscosity having dielectric strength not less than 60 KV complete all as specified and as directed :- 82Ltr NOTE:-Dielectric strength test shall be carried out at site before poring/filling in transformers in the presence of Engr-in-Charge on the site |
| 208 | M&L for Comprehensive maintenance of transformer by isolating ,disconnecting of input/output ,supply cable, opening of top of transformer, detecting of fault ,u/s component, cleaning of serviceable parts/ component ,includingreplacement of worn out spare parts, finding of oil leakage& sealing it by oil seal or gas welding etc if any complete all as specified and as directed. (Transformer 415 KVA) |
| 209 | Taking out VCB trolley from HT control panel 11 KV 3 phase 800 Amp , Breaking capacity 20kA (Make :- crompton greaves) and cleaning the trolley with CRCremoving all dust , carbon etc greasing the mechanical parts gears ,lever charging male female contacts and spring holders complete all as specified and as directed. |
| 210 | M&L for sevicing of VCB panel & calibration ofnumerical relay as per existing load for earth fault , over current and short circuit ,including setting the relay on required electric load and testing on earth fault and short circuit and over load with the help of relay testing kit complete in all respect all as specified and as directed. |
| 211 | S&F in transformer breathers sillica gel (orange) for effective beratheing & to protect transformer oil from moiture complete all as specified and as directed. |
| 212 | Technician for attendingofanybreakdown of HT/LT supply due to fault in VCB or transformer, whenever required round the clock ,rectify the fault and restore the standby supply within four five after receipt of complaint of any nature complete all as specified and as directed.Note -(i) The cost ofreplaced spare parts will be paid and measured seperatly.(ii)If complaint is not attended by contractorwith in five hour the penality of Rs 500 / per hourto be imposed and amount of penality will be deducted from RAR.(iii) Thecost of transportation (to and fro) for all kind ofnecessary equipment / T&P shall be arranged/brought by contractor to complete the job at site or at E/M yard and no extra cost shall be paid to the contractor to this effect. (iv) Complaint shall be lodged by telephonically ,so contractor to specifythe telephone no who willreceive the complaint round the clock. |
| 213 | M&L for Comprehensive maintenance of Main LT panel & cubical type indoor automatic capacitor panel by isolating ,disconnecting of input/output ,supply cable, detecting of fault ,u/s component in panel ,cleaning of serviceable parts/ component ,includingreplacement of worn out switches LED indicator, spare parts, Welding of Panel door & replacement of Door lock, replacement of old wiring with 2.5 sqmm to 6 sqmm etc, if required complete all as specified and as directed. Replacement of Capacitor of verious size will be measured & paid separately |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail