| 1 | Synthetic net |
| 2 | CIVIL WORK |
| 3 | Surface dressing of the ground including removing vegetation and ineqalities not exceeding 15 cm deep and disposal of rubbish lead up to 50 Mtr. And lift up to 1.5 Mtr. All kinds of soil. |
| 4 | Earth work in surface excavation not exceeding 30cm. in depth but exceeding 1.5 meter in width as well as10 Sqm on plan including disposal of excavated earth up to 50 Mtr. and lift up to 1.5 Mtr. disposed soil to be levelled and neatly dressed : All kinds of soil |
| 5 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. |
| 6 | M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 7 | Supply and fixing Jodhpur sand stone Machine cut Kerb stone (10cm wide 40 cm. height) fixed in white cement sand mortar 1:4 with pigment including EarthWork. |
| 8 | Construction of rolled cement concrete base course with coarse and fine aggregate conforming to IS: 383 , the size of coarse aggregate not exceeding 25 mm with minimum, aggregate cement ratio 15:1 and minimum cement content of 200 Kg/Cum, aggregate gradation to be as per Table 600-4 after blending, mixing in batching plant as per mix design at optimum moisture content, transporting to site, laying with a hydrostatic paver with electronic sensor, compacting with 8-10 tonnes smooth wheeled vibratory roller to achieve, the designed flexural strength, finishing and curing. |
| 9 | Providing and laying controlled cement concrete for cement concrete pavements including mixing and vibrations concrete with necessary needle vibrators and surface with screed board vibrating complete in all respect with stone aggregate (crusher broken) including anti-skid textured finish to required camber/ superelevation and grade including curing etc. as per specification |
| 10 | (-do-) with cement concrete M-35 grade |
| 11 | Add extra for vacuum processed concrete including cost of equipments labour etc. |
| 12 | Providing and laying antifriction layer of 3 ply Bituminous paper with 100 mm over-lapping in both directions. |
| 13 | Maxican(Carpet) grass tiles (2’X2’ size) for development of garden, including levelling of soil and spreading of manure |
| 14 | Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide |
| 15 | Extra if square,rectangular hollow tubelar sections are used or grill made by flats only |
| 16 | Providing and applying superior quality emulsion for wall painting with Velvet touch/Royal paint etc of approved brand and manufacture to give an even shade with putty and preparation of surface applying with the help of paint roller the work complete in all respect as per direction of Engineer-in-charge. |
| 17 | New Work Three or More coat |
| 18 | ELECTRIC WORK |
| 19 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it\"s ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 20 | Medium point (up to 6 mtr.) |
| 21 | Long point (up to 10 mtr.) |
| 22 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 23 | 25 mm |
| 24 | 32 mm |
| 25 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 26 | Single pole MCB (With B/C curve tripping Characteristics) |
| 27 | 6 A to 32 A rating |
| 28 | Double pole MCB(With B/C curve tripping Characteristics) |
| 29 | 6 A to 32 A rating |
| 30 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal typeDoubleDoor (Metal /Glazed)Distributionboard withMetalendboxmadeout fromGalvanizedsteel /CRCAsheet not less then1.2mmthick conforming to IS-8623-1&3 / IEC 61439-1&3,powderpaintedcompletewithreversibledoor (for doubledoorDBonly)100amp. insulatedcopperbusbar/shorting link , copper neutral link, copper earth link , color coded interconnectingwire set of suitable rating anddinbar,masking sheet, makinginternalDB terminationswithcopperlugs,Ferrules, detachableglandplate, includingmakingconnections, testingetc. asrequired.OEMshallhavesubmitNABL/CPRI/ERDAaccrediated lab type test reports &All asper preapprovedbyEngineer in charge.Foradditionaltechnicalparametersofproduct/workrefer Annexure \"A\" attached with this BSR |
| 31 | Metal Door (Single Face) IK 09 And TP-43 With Metal end box |
| 32 | 4 Way |
| 33 | Metal Door (Three Face) IK 09 And TP-43 With Metal end box |
| 34 | 4 Way |
| 35 | P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required. |
| 36 | Single pole MCB |
| 37 | 6 A to 32 A rating |
| 38 | Triple pole & neutral MCB |
| 39 | 6 A to 32 A rating |
| 40 | P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with Copper conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. |
| 41 | 2.5 Sq.mm |
| 42 | 4 core |
| 43 | 6.0 Sq.mm |
| 44 | 4 core |
| 45 | Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty Copper lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. |
| 46 | 4 x 2.5 sq.mm |
| 47 | 4 x 6.0 sq.mm |
| 48 | Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 49 | Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 50 | A) Excavation of Pit for Foundation Size upto required depth from Ground level |
| 51 | B) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete. |
| 52 | C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness |
| 53 | D) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete. |
| 54 | E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and Pedestal |
| 55 | F) Providing & Fixing of 2 No. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations. |
| 56 | G) Providing and Laying Reinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days. |
| 57 | H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 No. 100 mm long, 10 mm dia. Lugs on Each face. |
| 58 | Pole Foundation for Octagonal pole from 10 Mtr. To 12 Mtr. |
| 59 | Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall Not be any cirCumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 No. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 Sqmm stud type connector ( 4 Nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 60 | Poles with Octoganal Cross Section |
| 61 | 12 Mtr. |
| 62 | Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 63 | Single Arm Overhang |
| 64 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on Each LED & should be SMD type of 3 to 5 watt Each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 65 | Minimum lumen output 3000 lm Post top Luminarie Please Enable Macros to View BoQ information |