| 1 | Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr deep in soft/loose soil and getting out for taking down/laying Pipe lines of any description and in any position, complete all as specified and as directed. |
| 2 | All as per item No 1 above but in hard/dense soilcomplete all as specified and as directed. |
| 3 | Returning, filling in, excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed. |
| 4 | Removing of surplus soil to a distance not exceeding 50 M and depositing where directed at a level not exceeding 1.5M above the starting point complete all as specified and as directed. |
| 5 | Supply and fix GI tubing and fitting, 80 mm bore medium grade from wall/ trenches and disconnecting from main distribution lines including taking up or down and necessary cutting of existing pipe line and threding the same and dewatering work as required and removing from site, complete all as specified and as directed. |
| 6 | All as per item No 5 above but 50 mmbore complete all as specified and as directed. |
| 7 | All as per item No 5 above but 40 mmbore complete all as specified and as directed. |
| 8 | All as per item No 5 above but 32 mmbore complete all as specified and as directed. |
| 9 | All as per item No 5 above but 25 mmbore complete all as specified and as directed. |
| 10 | All as per item No 5above but 20 mmbore complete all as specified and as directed. |
| 11 | All as per item No 5above but 15 mmbore complete all as specified and as directed. |
| 12 | Taking out from trenches, 300 mm bore dia DI pipe lines (including all fittings) with spigot & socket ends with lead joints etc. including taking out from joints complete all as specified and asdirected.Note: Earth work & excavation shall be measured & paid for separately |
| 13 | All as per item No 12 above but of 250 mm bore complete all as specified and as directed. |
| 14 | All as per item No 12 above but of 200 mm bore complete all as specified and as directed. |
| 15 | All as per item No 12 above but of 150 mm bore complete all as specified and as directed. |
| 16 | All as per item No 12 above but of 100 mm bore complete all as specified and as directed. |
| 17 | All as per item No 12 above but of 80 mm bore complete all as specified and as directed. |
| 18 | M&L for relaying of old DI pipe 300mm bore dia after clearing and removing all the accumulated sediments from the pipe, jointing the pipe and testing complete including joints, complete all as specified and as directed.[Note: Excavation and earth work shall be measured and paid separately] |
| 19 | All as per item No 18 above but of 250 mm bore complete all as specified and as directed. |
| 20 | All as per item No 18 above but of 200 mm bore complete all as specified and as directed. |
| 21 | All as per item No 18 above but of 150 mm bore complete all as specified and as directed. |
| 22 | All as per item No 18 above but of 100 mm bore complete all as specified and as directed. |
| 23 | All as per item No 18 above but of 80 mm bore complete all as specified and as directed. |
| 24 | Supplying ,laying, jointing & testing in trenches in repairDI pipe (K7) 300 mm bore with spigot and socketed ends centrifugally cast (spun cast)and including of rubber tyton joints,complete all as specified and directed.Note : (i)Earth work and CI specials/fittings of the pipes shall be measured andpaid for separately under appropriate item of Schedule `A\"(ii) Joints of the pipes shall be included in the item quoted rates. |
| 25 | All as per item No 24 above but of 250 mm bore complete all as specified and as directed. |
| 26 | All as per item No 24 above but of 200 mm bore complete all as specified and as directed. |
| 27 | All as per item No 24 above but of 150 mm bore complete all as specified and as directed. |
| 28 | All as per item No 24 above but of 100 mm bore complete all as specified and as directed. |
| 29 | All as per item No 24 above but of 80 mm bore complete all as specified and as directed. |
| 30 | Supply and fix High density polyethylene pipes (HDPE-80) of size 110mm pressure rating 6 kgf/cm2laid in trenches including taking up or down and necessary cutting of existing pipe line and threding the same and dewatering work as required and removing from site complete all as specified and as directed. |
| 31 | All as per item No 30 above but of 75 mm bore complete all as specified and as directed. |
| 32 | All as per item No 32 above but of 50 mm bore complete all as specified and as directed. |
| 33 | All as per item No 32 above but of 25 mm bore complete all as specified and as directed. |
| 34 | MCX-12 Power Contactor 4 Pole of capacity 63 Amp, confirms to IS/IEC-60947-4-1 & IEC 60947-4-1,for DG set,standard coil voltage 110V, 220V, 240V and 415 V, 50 HZ .complete all as specified and as directed. |
| 35 | Re-laying and re-fixing old galvanized iron serviceable pipes 40/50/ 80mm bore dia in new or old position including cleaning and de-scaling the internal surface of pipes using wire brushes and cleaning thoroughly with fresh water to remove mud/ soft deposited sludge inside the pipes complete all as specified and as directed. |
| 36 | All as per item No 35 above but 25-32 mmbore complete all as specified and as directed. |
| 37 | All as per item No 35 above but 15/20 mmbore complete all as specified and as directed. |
| 38 | M&L for Cutting existing steel tubing of size 40/50/80 mm for alterations or additions (Each cut measured), complete all as specified and directed |
| 39 | All as per item No 38 above but 25-32 mmbore complete all as specified and as directed. |
| 40 | All as per item No 38 above but 15/20 mmbore complete all as specified and as directed. |
| 41 | Supply & fixing in repair 200 mm bore , cast iron sluice valve of class PN-1.6 conforming to IS-14846 of 2000 both ends flanged with iron wheel head and stainless steel spindle, long body type,jointing and testing, ISI Marked, of approved quality including taking down of old u/s sluice valve, complete all as specified and directed. |
| 42 | All as per item No 41 above but of 150 mm complete all as specified and as directed. |
| 43 | All as per item No 41 above but of 100 mm complete all as specified and as directed. |
| 44 | All as per item No 41 above but of 80 mm complete all as specified and as directed. |
| 45 | Supply & fixing in repair 50 mm bore gun metal globe/gate valve with iron wheel head, both ends screwed for iron pipe , jointing and testing ISI Marked approved quality including taking down old unsv valves, complete all as specified and directed. |
| 46 | All as per item No 45 above but of 40 mm complete all as specified and as directed. |
| 47 | All as per item No 45 above but of 25 mm complete all as specified and as directed. |
| 48 | All as per item No 45 above but of 20 mm complete all as specified and as directed. |
| 49 | Supply & fixing in repair Ball valves for pipe size 25mm high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 25-455gms)and fixed ISI Marked approved quality including taking down old unsv valves,complete all as specified and directed. |
| 50 | M & L for CI fittingfor spigot & socket end pipes such as Bends (any type, radius and angle), Tapers any type (Straight, bend, increasing, decreasing or double socket etc), Tee pieces single branch, `Y` junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs andmechanicaljoints etc 200 mm to 300 mm bore including removing/ dismantling of old CI fittings complete all as specified and directed. |
| 51 | M & L for CI fittingfor spigot & socket end pipes such as Bends (any type, radius and angle), Tapers any type (Straight, bend, increasing, decreasing or double socket etc), Tee pieces single branch, `Y` junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs andmechanicaljoints etc upto 150 mm bore including removing/ dismantling of old CI fittings complete all as specified and directed. |
| 52 | M & L for Cuttingout of hard standing,concrete blocks,slabs,brickwork or stone masonry (in alter nate course), forming tooth-ings for and bonding new work in mortar into old work, including new materials with complete andmaking good to the disturbed surface by using PCC of C1, 20 mm Grade 1:3:6 up to the depth for laying of water pipe line in soil complete all as specified and directed. |
| 53 | Demolition of oldvalve pit chamberand M&L for Construction of valvepit chamberof size 900 x 900 x 900 mm with 15 Cm thick PCC foundation in1:4:8 type D2 ( using 40 mm graded stone aggregate) and 15 cm thick hard core, brick masonary work with flyash bricksbuilt in CM (1:6), 15 mm thick internal & external plastering in CM (1:4), MS sheet cover 4 mm thick including 50 x 50 x 5 mm MS angle frame fixed in coping of PCC 1:2:4 type B-1 ( using 20 mm stone aggregate) making hole in valve chamber cover as per sluice valve location in side the valve chamber for insurtion of MS rod of 12 mm dia of 1.5m long along with valve spindle cap properly welded to ms rodwith locking arrangement & painting with one coat of red oxide & two coats of black bituminous paint complete all as specified & directed |
| 54 | Material and labour for PCC Type D2 ,1:3:6by using ( 40 mm aggregatestone aggregate)to makeup of hardstanding/road etc copings, complete all as specified and directed. |
| 55 | Supply and lay MS Pipes of size 100/150 mmheavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes as shown, complete all as specified and directed |
| 56 | Supply and lay in replacement Pipe cast Iron, S/S including specials, Class\"B\", 150mm(8\") dia, complete all as specified and directed |
| 57 | M&L for outdoor type cubical panel board made out of 3.15 mm thick CRCA sheet and made M&L for outdoor type cubical panel board made out of 3.15 mm thick CRCA sheetfor outer shelland made ot of 2 mm thick CRCA sheet for inner shell and MS angle frame 50X50X6 (minimum height 2 feet) mm CPRI approved fabricated double door including CT and PT of suitable rating with internal connection in aluminium strip of suitable rating both side openable suitable for 3 phase 415 V powder coated 90 microns comprising of following :-(a) TPN 04 nos aluminium busbar in equal size 3 phase and neutral 250 amp rating duly insulated fitted on heat shrinkable insulation and covered with colour sleeve.(b) Incommer MCCB, 4 polehaving current ratings 160 Amps, AC 415 Volts, withIcu= 25 KA ,Ics = 100% ofIcu,with thermal magnetic release, complete with spreader links-Qty - 01 No (L&T Cat No CM91712O OKOOG)(c) Onload Changeover switch 160 Amp - 01 No ( L&T Cat No CO21600OOOO)(d)MCCB, 4 polehaving current ratings 100 Amps, AC 415 Volts, withIcu=16 KA, Ics = 100% ofIcu, with thermal magnetic release,complete with spreader links- Qty -01 Nos (L&T Cat No CM91712O OKOOG)(e)MCCB, 4 polehaving current ratings 63 Amps, AC 415 Volts, withIcu=16 KA, Ics = 100% ofIcu, with thermal magnetic release,complete with spreader links- Qty -04 Nos(L&T Cat NoCM91712O OHOOG)Contd../- |
| 58 | Contd..57/-(f) MotorStarterType MOG-H2 (Rotary Type) - Frame 2 of capacity 32 Amps with short circuit and overload protection (L&T Cat No ST41919OOO) - Qty 04 Nos(g)Multifunction meter for measure,current of Amp, Voltage and Frequency.(h) LED Indicator lamp - 01 Set of Three. |
| 59 | M&L for repair to leakage of DI/CI 100/80 bore water mains including disposal of water from trench by manualy or mechanically, excavation and earth work in any type of soil, removing of oldjoints, cleaning joints and re-fixing new joints to make joint leak proof competeall as specified and as directed. |
| 60 | All as per item No 58 above but of 50/40/32 mm |
| 61 | All as per item No 58 above but of 25/20 mm |
| 62 | Material andLabour for uprooting vegitation, bushes, creepers, weeds , including trimming of branches of trees touching inside sub stations/pumping stn/over head reservoir area,under ground sump area with the help of spade,crowbar,axes or any other tools mannually/chemical spraying, complete all as specfied and as directed. |
| 63 | M&L for dewatering the water from sump, by any means and clean the interior portion of sump (bottom andsides of walls) by means of coir/wire brush etc. and wash the interior portion of sump by using bleaching powder @ 25 grams per 1000 ltrs of water after removal of sludge, mud etc. to a distance not exc. 50m and one coat of cement based paint on external RCC / masonry surface of reservoir, one coat of epoxy paint on all steel surfaces such as ladder, railing etc.andwriting letters with white paint (Date of cleaning and capacity of sump / reservoir) on black painted surface and clear away all vegetations, sapling, under growth roots etc. and trees not exc. 30cm girth upto 3m around the periphery of the sump / structure from external wall surfaces andremoving rubbish not exc. 50m for the anycapacity of under ground sumps complete all as specified & as directed. |
| 64 | M&L for cleaning of RCC over head reservoirs/steel tanks by brooming down all the side walls, bottom and top, removing fungus, scales dirt sludge etc. from inside and depositing the same at a distance not more than 100 mtrs after emptying the tank completely and washing the tank inside with water and chemicals such as bleaching powder, costic soda etc and applying one coat of white wash on internal surface of the tank and one coat of cement base paint (snocem) on external surface of the tank and writing date of cleaning in white capital letters on black back ground, size of letters 80 x 10mm with sythetic enamel paint and marking the direction of flow and painting all inlets, outlets, washouts and overflow pipes with one coat of black epoxy paint completeincluding draining of excess water in tank by providing pump,cleaning vegitation from tank/sumpsite of 10 mtr distancefrom plinth all as specified and as directed and all safety measures are to be adopted while performingincluding arresting the leakagesand removing growths on OHT walls, complete all as specified and directed |
| 65 | Material and labour for copper earthing complete with copper earth plate of size 600x600x3.15mm thick burried directly in ground (earth plate not less than 2.25mtr deep below normal ground level ) with top edge of the plate not less then 1.50 mtr.below the normal ground level connected to copper earth lead strip 25 x 4 mm dia by means of bolts nuts, check nuts & washer of brass all as shown in electrical plate No 3 connected to earthing test point all as specified and testing on completion including the material and labour for:-(a)Excavation and earth work or drilling hole for electrode in any type of soil(b)PCC pit in cement concrete 1:2:4, TYPE B-1(c)Pre-cast RCC cover with suitable handle 40mm thick in PCC 1:2:4 reinforced with welded steel wire fabric(d)Funnel with watering pipe of GI 40mm medium grade nominal bore light grade and copper lugs etc all as specified.(e)Earthing strip of size 25 x 4 mm upto 7.50 mtr length shall be included in the quoted rates.(f)GI pipe 40mm medium grade protection pipe of 7.50 metre long for protection of earthing lead shall be included in the quoted rates.(g) Requisite quantity of back fill compund (Earth enhancing compund ) (Min 40 Kg) and salt 50 kg(h) Connection to earthing test point and testing on completion. |
| 66 | M&L for painting of different sizes of pumps,motors, connecting pipes and its related items at various installations, including writing of MES/SM No as per colour code all as specified and directed |
| 67 | Dismantling and taking down of defective motorsof any type and any capacity from Pump House/UG Sump including transpotationto civilworkshop for repairing,overhauling and re-fixingafter the repair etc complete all as specified and as directed. |
| 68 | M& L for rewinding (copper) completewith insulation, varnishing of motors of any capacity to match with the existing original winding etc complete all as specified and as directed. |
| 69 | S&F in replacement LED 10 watt, white colour water proof lights IP 66 with Automatic Controller System including taking down complete all as specified and directed |
| 70 | Supply and fixing in repair brass 25mm air release valve pressure rating (PN-1) and tamper proof with air outlets with nuts, bolts and washer and conforming to IS-14845 including cutting and fixing complete all as specified and directed. |
| 71 | Supply only Digital PH Meter, complete all as specified and as directed. |
| 72 | Supply onlyDigital TDS Meter, complete all as specified and as directed. |
| 73 | Supply and fixing in replacement of DOL starter suitable for 3 phase 15 HP motor 415 volts pumping set complete all as specified and as directed. |
| 74 | Supply and fix in repair CI foot valve Ball 150/200 mm type double end flanged/ drilled PN-0.2, ISI marked, with including necessary cutting of existing suction pipe line of any type and welding, jointing and jointing materials such nuts, bolts, washers, flangeand rubber gaskets etc of any size with reinforced rubber nitrile ball including taking out unserviceable CI foot valve complete all as specified and directed. |
| 75 | Supply and fix inrepair CI Non-return valve Ball type double end flanged/ drilled, PN-10 with including necessary cutting of existing delivery pipe line of any type and welding, jointing and jointing materials such nuts, bolts, washers, flangeand rubber gaskets etc for the pipe of 100/80 mm bore with reinforced rubber nitrile ball including taking out unserviceable CI non return valve complete all as specified and directed. |
| 76 | Supply and fixing in replacement PVC insulated6 sqmm copper conductor three core cable flat, 1100 volt grade for submersible pumping set etc, complete all as specified and as directed |
| 77 | Supply and fixing in replacement PVC insulated1.5 sqmm, 3 core copper conductor three core cable round, 1100 volt grade for submersible pumping set etc, complete all as specified and as directed |
| 78 | Supply and fix in replacement of MPM2-5100-V24 Single Phase 1 HP Booster Pressure riser with TankPump Size: 25x25 mmSeries: MMB, Voltage: 220 VType of Product: Booster Pressure Pump with Tank, Flow Rate: 3900-1380 LPH Head: 15-44 mModel No: HMPM2-5100-V24, Power Rating: 0.75 kW, complete all as specified and directed. |
| 79 | Supply install testing and commissioning Heavy duty Chemical Dosing system plunger type suitable to inject solution upto 25 LPH working pressure 10 kg /cm2 comprising dosing pump coupled with three phase electric motor of capacity 0.5 HP,1440 RPM assembly with agitator in one motor , agitator with SS sweep blade duly FRP coated, FRP tank 150 ltrs capacity, complete unit mounted on heavy duty MS fabricated frame duly anticorrosive paint complete with Chemical grade PVC NRV. along with Control panel for Dosing Pump suitable for made of powder coated MS fabricated box consisting of LED indicator, digital Volt meter, Amp meter, single phase preventor, High voltage low voltage protection complete all as specified and as directed. |
| 80 | Dismatling/taking out exsisting unserviceable water level indicator from over head reservoir and supply and fixing new digital water level indicator The system automatically indicates water level in underground sump / overhead tank.The different level indications are 20%, 40%, 60%, 80%, and 100%.When water level reaches 100% an audible Buzzer indication can also be provided.The system has selectable Low Level Buzzer which can be set for required level during Installation.The system has Buzzer Mute button in front panel.The Indicator unit is madeup of Industrial Grade Plastic Enclosure.System should be based on AC sensing technology andthe sensors should be non-corrosive and maintenance free, complete all as specified and directed. |
| 81 | Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 200 Amps.Complete all as specified and directed. |
| 82 | M&L for brick work with sub class \"B\" bricks, old size straight or curved on plan exc. 6m mean radius using modular bricks built in cement mortar (1:4) complete all as specified and directed. |
| 83 | Supply and fixing in replacement ofBack-lit Flex Glow Sign Board, Single Side, Rectangle type made up of SITC of G.I box made of 18 SWG G.I sheet of minimum 7\" depth for glow sign board with 1.8 mm thick poly carbonate sheet front cover including coloured lettering with vinyl sheet and fixed with 25mm x 25 mm x 1 mm thick aluminium channel including fixing at different site as per direction of Engr-in-Charge. Size of the Glow SIgn Board should be 14 x 2.6 x 0.5 Feet approx / as per site requirement.one No. Red Oxide Coat on MS Board Frame, two Number of Synthetic Enamel Coat on MS Board Frame, Size of Copper cable/ wire with conduit (in 1.5 sqmm), complete all as specified and directed. ( Note :(i) Rate for fixing of boards with PCC 1:2:4type B2 filling to be incl in unit rate. (ii) The board letters, colour and background should be as per direction given by Engineer-in-Charge) (ii)Any Iron work required for the frame to be measured and paid seperately |
| 84 | Supply and fixing in repair retro reflective boards in shape of rectangle of sizenot less than 2.0 m x2.0 m made out of 2 mm thick stainless steel both side bounded/pasted with high prismatic (iv) sheet mannufactured by avery dennison or 3M with desired letters/logos designed as directed the board shall be supplied with and including stainless steel frame made out of 25 mm dia pipe in frame around duly welded with and including stainless steel sheet and stainless steel posts of 38 mm dia and full lengthof 2.20m one side and 2.8 m other side complete all as specified and directed. ( Note :(i) Rate for fixing of boards with PCC 1:2:4type B2 filling of size 45x45x60 cm to be incl in unit rate. (ii) The board should be written description as direction given by Engineer-in-Charge) |
| 85 | Sampling and testing of water for the conformation of Desirable/permissible limit of following requirements for \"Drinking Water\" as per IS:10500-1991 from Govt approved Laboratory includiing transportation of warer complete all as specified and directed. (a)Bacteriological requirements: Testing of coliform organism/100ml(b)Chemical requirements: Testing of colour Hazen Unit Max, Odour, Taste, Turbidity NTU max, pH Value, Total Hardness (as CaCO3) mg/l max, Iron (as Fe) mg/l max(c)Desirable Characterestics: Testing of dissolved Solids mg/l max, Calcium (as Ca) mg/l max, Magnesium (as Mg) mg/l max, Copper (as Cu) mg/l max, Manganese (as Mn) mg/l max, Sulphate (as SO4) Mg/l max, Nitrate (as NO3) mg/l, phenolic compound mg/l max, mercury (as mg) mg/l max, Cadmium (as Cd) mg/l max, lenium (as Se) mg/l max, Arsenic (as As) mg/l max, Cyanide (as CN) mg/ max, Lead (as Pb) mg/l max, Zinc (as Zn) mg/l max, Chromium (as Cr+6)mg/l Max, Mineral Oil, mg/l max, presence of Radioactive substance and pesticides, complete all as specified and directed |
| 86 | M&L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified and as directed including painting with two coats of synthetic enamel paint/ lead free black bituminous paint as directed over a coat of zinc chrome primer. Complete all as specified and directed |
| 87 | M & L for Cuttingout of hard standing,concrete blocks,slabs,brickwork or stone masonry (in alter nate course), forming tooth-ings for and bonding new work in mortar into old work, including new materials with complete andmaking good to the disturbed surface by using PCC of C1, 20 mm Grade 1:3:6 up to the depth for laying of water pipe line in soil complete all as specified and directed. |
| 88 | Supply, install, testing and commissioning of Sump / OHT Alarm System, consisting of Alarm and float switch including 0.75 sqmm copper wire 3 core from Underground Sump/Overhead Tank to Pump house (approx length 100 RM).The system should be automatically senses water Full / Low level in underground sump / overhead tank,built-in Siren or Buzzer which will be driven when water level reaches tank Full level. The system can be modified to have built-in Siren or Buzzer which will be driven when water level reaches tank Low levelThe system will not be connected to Pumpset starter, so the system can be installed in any convenient place.The pump alarm system provides warning on overflow / water levels reach a level pre-set by you. complete all as specified and directed. |
| 89 | M & L for 2 mm thick Mild steel, plain, black sheet in wall cladding,steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up and welding handle for lifting, mitred angles, etc as required complete all as specified and directed. |
| 90 | NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs. 93,904.00] |