| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. DSR (E&M) 2022- 1.1.2 |
| 2 | Provision for 20 mm diA, I1SI marked, PVC conduit. DSR (E&M) 2022- 1224 |
| 3 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet. DSR (E&M) 2022- 1.24.4 |
| 4 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. DSR (E&M) 2022- 1.12 |
| 5 | Supplying and fixing brass batten/ angle holder including connection etc. as required. DSR (E&M) 2022- 1.34 |
| 6 | Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc. as required. 12 Module (200mmX150mm) DSR (E&M) 2022- 1.27.6 |
| 7 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor notless than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. DSR (E&M) 2022- 19.10 |
| 8 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. DSR (E&M) 2022- 1.25 |
| 9 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 6 way , Double door. DSR (E&M) 2022- 2.3.1 |
| 10 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole. DSR (E&M) 2022- 2.10.1 |
| 11 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. DSR (E&M) 2022- 5.2 |
| 12 | 40-watt LED Batten/Tubelight | StarBright Compact 4-ft Decorative Modern LED Wall Tubelight for Room, fitting all complet directed by engineer in charges. ( As per market rate for estimate purpose) |
| 13 | Supply of 15W LED Bulb fitting with complete in all respect. ( As per market rate for estimate purpose) |
| 14 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. DSR 2023- 2.31 |
| 15 | Boring of pile hole 200 mm diameter ,3.50 m deep single under reamed of 50 cm diameter I/c all as directed by engineer in charge. (SOR. Dt. 25.07.2022 - chapter no. 4 new item 1) |
| 16 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.DSR 2023- 2.2.8. |
| 17 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering finishing and reinforcement - All work up to plinth level 1:1½:3 cement, coarse sand and 20mm gauge stone grit including all complete. DSR 2023- 5.1.2 |
| 18 | Foundations, footings, bases of columns, etc. for concrete Shuttering - DSR 2023- 5.9.1 |
| 19 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) DSR 2023- 6.1.1 |
| 20 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) .DSR 2023- 4.10 |
| 21 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) DSR 2023 - .5.2.2 |
| 22 | Foundations, footings, bases of columns, etc. for concrete Shuttering - DSR 2023- 5.9.1 |
| 23 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 4 coarse sand) .DSR 2023- 6.4.2 |
| 24 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). DSR 2023- 5.30 |
| 25 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. for concrete Shuttering - DSR 2023- 5.9.15 |
| 26 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). DSR 2023- 5.30 |
| 27 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. for concrete Shuttering - DSR 2023- 5.9.5 |
| 28 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). DSR 2023- 5.30 |
| 29 | roofs, landings, balconies and access platform . for concrete Shuttering - DSR 2023- 5.9.3 |
| 30 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D. DSR 2023- 5.22.6 |
| 31 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) DSR 2023- 22.14.1 |
| 32 | Plaster 12 mm thick with cement, fine sand mortar in proportion of 1:6 in fair side of wall I/c all complete as directed by engineer in charge etc. DSR 2023- 13.4.2 |
| 33 | Plaster 15 mm thick with cement, fine sand mortar in proportion of 1:6 in rough side of wall I/c all complete as directed by engineer in charge etc. DSR 2023- 13.5.2 |
| 34 | Excavating, supplying and filling of local earth by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. DSR 2023- 2.5 (a) |
| 35 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. DSR 2023- 2.70 |
| 36 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) DSR 2023- 4.1.8 |
| 37 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). DSR 2023 C.P.no. 11 - Item Code no. 11.47.2. |
| 38 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) DSR 2023 - 13.46.1 |
| 39 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade, New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre. DSR 2023 - 13.41.1 |
| 40 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. DSR 2023 - 13.80 |
| 41 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class teak wood, 35 mm thick. DSR 2023 - 9.9.1.1 |
| 42 | Provision for Stainless Steel, Door Handle Lock or Main & Internal Door. (As per market rate for estimate purpose) |
| 43 | Provision for Stainless Steel Main Door Pull Handle for All the Doors of House, Office, Hotels Stainless Steel for Glass Door/Wooden Door Handle/Pull and Push Handle. (As per market rate for estimate purpose) |
| 44 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge : With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm). (As per mareket rate for estimate purpose) |
| 45 | Providing & fixing of Voltac / similar Split A.C. 2.00 Ton with stablizer. completed ISI marked. (As per Market rate for estimate purpose) |
| 46 | Supply of Voltas / Similar Stabilizer VA5130: 5 KVA, Toroidal Core Transformer, 130V-300V - Suitable for 2 TR Air Conditioners. (As per market rate for estimate purpose) |
| 47 | Supply of Revolving chair (As per market rate for estimate purpose). |
| 48 | Supply of Visitor chair (As per market rate for estimate purpose). |
| 49 | Providing and fixing office furniture material with labour, Table, Counter etc. (As per market rate for estimate purpose)/ |
| 50 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.. DSR 2023 - 10.31 |
| 51 | Provision for Toilet Repair. |
| 52 | Supply and fixing of Add Sign board / Sila Patt & photography etc. (For Estimate Purpuse) Please Enable Macros to View BoQ information |