| 1 | Excavation in foundation in ordinary soil (Loam, clay or sand) including lift upto 1.50 M. and lead upto 30 M. and including filling watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplusearth as directed by the Engineer-in-charge upto a distance of 30 M. from the foundationtrenches. (Where machine can notreach/move). S.I N0 251 (a) |
| 2 | P.C.C with 4 cm gauge in proportion 1:6:12 cement, c/sand & 4cm brick ballast in fondation and under floor including supply of all materials labour T&p all complete (Item no273) |
| 3 | Brick work m 150 in 1:4 one cement &four coarse sand of 1.25 F.M mortar.in foundation and plinth all comp. si no. 305 (sub structure) |
| 4 | 2 cm thick Damp Proof Course with Cement and approved coarse sand 1:2 with and including water proofing as ordered by the Engineer incharge in the proportion as specified by the manufacturer including supply of all materials, labour, Tools & plants etc. required for proper completion of the work and including proper curing & shutterings as necessary. in sub stucturu (S.I no. 360) |
| 5 | Brick work m 150 in 1:4 one cement &four coarse sand of 2.20 F.M mortar comp. si no. 305 a |
| 6 | R.C.C. work with Cement approved coarse sand and 2 cm.(3/4\") gauge approved stone ballast in the proportions of 1:2:4 in lintels fo doors and windows excluding supply of reinforcement and its binding but including its fixing and binding the same with 24 B.W. G.G.I., binding wire and including necessary centering and shuttering etc. and also including supply of all materials, labour and T & P etc. required for proper completion of the work. Excluding cost of Binding wire.(S.I no. 283) |
| 7 | R.C.C. work with Cement approved coarse sand and 2 cm. gauge approved stone ballast in the proportions of 1:2:4 in roof slab (S.I no. 284) |
| 8 | M.S. (tor steel or plain) in Plain work such as R.C.C. or R.B. work including bending for proper shape as necessary including bending for proper complition of the work and including supply of all steel & wastage , bend, hooks, and all complete. (S.I no. 504) |
| 9 | Providing and laying vitrified floor tiles in different sizes ( thickness to be spacified by the manufacture0 with water absoroption less 0.08% and conforming to IS:15622, OF APPROVED MAKE, In all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement :4 coarse sand),joining with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and maching pigment etc complete. SOR 2022 SI. No. new item. (14.21 a)+(14.21b) |
| 10 | 12 mm thick plaster in 1:4 cement and coarse sand mortal. SI. No. 584 |
| 11 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 Kms. from the site of work and including watering, dressing etc. labour and T&P etc. required for the proper complition of the work. Comp. (SI. No. 255) |
| 12 | three coat snowcem with water proof cement paint including supply of all material, labour, tools and etc. (SI. No. 660+661) |
| 13 | S/F of collapsible gate(SI. No. 518) |
| 14 | Providing and fixing 30 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71 mm width & 28mm thick as vertical & horizontal styles. Joints are made using solvent adhesive and GI \"C sections (39mm x 19mm x O.6mm thick) or M S pipe (40mm x 20mm ) stiffener frame insert & telescopic polymeric \"L\" corners .The panel shall be filled with 3mm thick high - pressure compact laminate as per manufacturer\"s specifications and directions of the Engineer-in-charge, cover moulding shall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter).125 mm. (SI. no. 9.78 ) |
| 15 | S/F of aluminium frame for window & ventilator (DSR no. 21.5) |
| 16 | Painting two coats with enamel paint over one coat of primer (SI. No. 644+645) |
| 17 | Providing and laying pressed clay tiles (as per approved pattern 20mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1cement:4 coarse sand ) mixed with 2% integral water proofing compound laid over a bed of 20mm thick cement mortar 1:4 (1 cement :4 coarse sand) and finished neat complete. DSR NO. 12.20 |
| 18 | S/F of graynite stone for partition of urinals & for wash basing (DSR 8.9.1.2) |
| 19 | S/F of white vitreous chaina orissa pattern w c oan size 580X440mm DSR No. 17.1.1 |
| 20 | S/F white chaina pededtal type wc (europeon type) DSR No. 17.2.1 |
| 21 | S/F of urinal pot for gents. SOR LKN SI. No. 17.4.1 |
| 22 | S/F of urinal pot for female SOR LKN SI. No. 17.16 |
| 23 | S/F of WHITE VITRIOUS wash basin size 630*450 mm with a pair of 15mm C P brass piller Tap (DRS no. 17.7.1) |
| 24 | S/F of CP bib cock. (DSR NO. 18.49.1) |
| 25 | S/F of GI pipe 15mm concealed (DSR SI. No. 18.10.1) |
| 26 | S/F of GI pipe 20mm concealed (DSR SI. No. 18.10.2) |
| 27 | S/F pf P.V.C water tank 1000 litters. (DSR SI. No. 18.48) |
| 28 | S/F of looking mirroe 600X450mm (DSR No. 17.32.2) |
| 29 | P/F of 110mm dia P.V.C pipe includig tee and band etc. comp. |
| 30 | Wiring points for light in PVC conduit pipe with plush type switch |
| 31 | Wiring points for 5Amp plug point in PVC conduit pipe / bands with plush type switch Etc. all complete |
| 32 | S/F of Batton holders/ bulbs Etc. complete |
| 33 | Making earthing complete and wiring, Wall cutting Etc. |
| 34 | Excavation in foundation in ordinary soil (Loam, clay or sand) including lift upto 1.50 M. and lead upto 30 M. S.I N0 251 (a) |
| 35 | Cement Concrete in 1:6:12 cement file sand and 4 cm gauge brick ballast etc camp. SI. No. 273. |
| 36 | Cement Concrete in 1:2;4 cement coares sand and 2 cm gauge stone grit etc camp. SI. No. 279 (a) |
| 37 | M-150 Brick work in 1:4 cement and fine sand mortar.in foundation and plinth etc comp. si no. 305 (a) |
| 38 | M-150 Brick work in 1:4 cement and coarse sand mortar etc Honycomb wal in one Bric Thick Wall etc comp. si no. 305 (a)+309+310 |
| 39 | 12 mm thick plaster in 1:3 cement and coarse sand mortar etc. camp SI.no. 583 |
| 40 | RCC work in 1:2:4 cement coarse sand & 2cm gauge stone grit etc. camp in roop slab SI. No. 284 |
| 41 | M.S. or iron work in plan work such as reinforcement SI.no. 504 |
| 42 | S/L of brick bats in soak pit material rate 1© |
| 43 | S/L of 40mm gauge brick ballast in soak pit material rate 2 (b) |
| 44 | S/L of loacl sand in soak pit SI. No. 255(a) Please Enable Macros to View BoQ information |