| 1 | CIVIL WORKS |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. |
| 4 | Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form forColumns, Pillars, Piers, Abutments, Posts and Struts |
| 8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 10 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :cement mortar 1:4 (1 cement : 4 coarse sand) |
| 11 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) |
| 12 | 12 mm cement plaster of mix :1:4 (1 cement: 4 coarse sand) |
| 13 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 14 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 15 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 16 | Providing. Fitting and fixing of 6mm Multiwall Polycarbonate sheet including Fittings and Accessories as per design and drawing. |
| 17 | Providing. Fitting and fixing of Aluminium frame with top hung ventilators (900 x 500 mm) including 6mm thick multiwall polycarbonate sheets. |
| 18 | Providing, fitting and fixing 60% Shade net with a rollable arrangement. |
| 19 | ELECTRICAL WORKS |
| 20 | Wiring for circuit/submain line along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as requred. |
| 21 | 2 X 1.5 Sq.mm + 1 X 1.5 Sq.mm |
| 22 | 2 X 2.5 Sq.mm + 1 X 2.5 Sq.mm earth wire |
| 23 | Supplying and fixing metal box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover as required (one board for A/C starter)200 X 150 x 60 mm |
| 24 | Supplying and foxing PVC batten/angle holder including connections etc. as required. |
| 25 | Providing and fixing LED bulb 10W |
| 26 | Supplying and fixing following piano type switch/socket on the existing switch box/cover including connection etc. as required. |
| 27 | 5/6 Apms switch |
| 28 | 3 pin 5/6A socket outlet |
| 29 | Supply of window type Air Conditioner, 1.5 TR |
| 30 | Installation charge of Air Conditioner |
| 31 | M.S frame for installation of Air Conditioner |
| 32 | Providing and fixing starter with board |
| 33 | Providing and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, din rail, interconnections, powder painted including earthing as required (without MCB/RCCB/Isolator) 12 way, double door |
| 34 | Supplying and fixing 6A to 32A rating, 240/415V, 10KA, \"C\" curve Miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 35 | Single pole, 6-32A |
| 36 | Triple pole and neutral |
| 37 | Providing and fixing following capacity TP&N disconnector fuse switch unit with enclosure and ISI mark HRC fuse including drilling holes, making connections etc. as required. |