| 1 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 2 | 8 way, Double door |
| 3 | 6 way, Double door |
| 4 | Supplying and fixing following way, horizontal type three pole and neutral sheet steel, MCB distribution board, 415V on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc as required. (But without MCB/RCCB/Isolator) |
| 5 | 4 way(4+12), Double door |
| 6 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 7 | Single pole |
| 8 | Single pole and neutral |
| 9 | Triple pole and neutral |
| 10 | Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range-5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumptionshould not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mFRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumenefficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape sizeand CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LEDjunction temperature shall not rise above 90°C). |
| 11 | 18-22 Watt |
| 12 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 13 | 1200mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 210 CM/Min (Minimum) |
| 14 | Supplying, installation, testing and commissioning of 1200 mm 20W LED Aluminium LTT8-20 tubelight with extruded Al body (single side connection) with in-built driver and efficacy of 100 lumens/W by fixing in the existing T8 LED box type luminaire with G13 lamp holders using necessary clamps and also dismantling the existing tube including giving connections etc. at site of work as required.(NABL certified as per ISO/IEC specification) |
| 15 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 16 | 72 Watt |
| 17 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 18 | 45 Watt |
| 19 | Supplying and fixing 30A ,415V, TPN industrial type socket outlet with 4 pole and earth, metal enclosed plugtop along with 30A\"C\" curve,TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc as required |
| 20 | Replacement of 70W Street light Xitanium Driver in the existing Crompton/Havells etc., make 70W street light fitting including dismantling the existing fitting, checking, refixing, giving connections etc. at site of work as required. |
| 21 | Supplying of PVC/XLPE armoured cable with aluminium conductor 1.1 KV Gradeconfirming to IS 7098 (part I)1988 with upto date amendments of the following size at the site of work. |
| 22 | 2 X 10 Sqmm |
| 23 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. |
| 24 | upto 35 Sqmm |
| 25 | Supplying and fixing of light class G.l. pipe of 50 mm dia. (nominal) 3 metres length along the pole/wall for protection of under ground cable as required. |
| 26 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required. |
| 27 | 100mm Dia |
| 28 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 29 | Upto 35 sq. mm |
| 30 | Demolishing cement concrete manually/ by mechanical mean including disposal of material within 50 metres lead as per the Engineer-in -charge |
| 31 | Nominal concrete 1:3:6 or richer mix (including equivalent design mix) |
| 32 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:2:4 (1 cement : 2 coarse sand (Zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 33 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beamangle 30 deg-120deg as per the application and theproject requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 34 | 100 Watt |
| 35 | Replacement of 120W flood light Xitanium Driver in the existing Crompton/Havells etc., make 120W flood light fitting including dismantling the existing fitting, checking, refixing, giving connections etc. at site of work as required. |
| 36 | Supplying of 300 mm sweep, min. of 1350 RPM speed, min. of 1160 CMM air delivery Heavy Duty exhaust fan with Sturdy metal body with metal blades & Metal louvers for protection from birds and foreign matter etc., as required at the site of work. |
| 37 | Installing of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning,etc as required. (Upto 450mm sweep) |
| 38 | Supplying and drawing of 1.5 Sq.mm,three core PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts, conforming to IS: 694 in the existing surface/ recessed steel/ PVC conduit as required. |
| 39 | Supplying and fixing street light loop in loop out boxes with PVC Sintex Box of size 140mmx140mmx95mm with PVC enclosure 1 Nos. 6A SP MCB, 2/4 way strip connector i/c testing as reqd. |
| 40 | Earthing with 60mm outer dia, 2 mtr length GI earthing electrode, completely filled with conductive crystalline compound ,fitted with minimum of 40x6x2000mm GI strip including 50 kgs of eco friendly maintenance free earthing compound to enhance soil conductivity and providing masonry enclosure with cover plate having locking arrangement etc at the site of work as required. |
| 41 | Supplying and laying 6 SWG G.I wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with GI thimble etc.as required |
| 42 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 43 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 44 | 2 X 10 Sqmm(19mm) |
| 45 | Supplying and fixing 20A ,240V, SPN industrial type socket outlet with 2 pole and earth, metal enclosed plugtop along with 20A\"C\" curve,SPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc as required |
| 46 | Supplying and fixing two modular stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required |
| 47 | Supplying and fixing of 300 mm x 300 mm size metalic frame cover fabricated with 25 mm x 25 mm x 3 mm thick angle iron welded construction frame structured and 1.6 mm thick M. S. sheet cover plate panel with double hinges and knobe type locking arrangement including painting, making recess in wall of 300 mm Width x 300 mm Height x 150 mm Depth, masonary, plastering & finishing the good etc as required |
| 48 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 49 | Group C |
| 50 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 51 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 52 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 53 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 54 | 6 Module (200mmX75mm) |
| 55 | 12 Module (200mmX150mm) |
| 56 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 57 | 5/6 A switch |
| 58 | 3 pin 5/6A socket outlet |
| 59 | Dismantling of pole/ street light standard/strut embedded in cement concrete foundation etc as required |
| 60 | Replacement of 70W LED Well glass light Xitanium Driver in the existing Crompton/Havells etc., make 70W well glass light fitting including dismantling the existing fitting, checking, refixing, giving connections etc. at site of work as required. |
| 61 | Replacement of 40W LED Well glass light Xitanium Driver in the existing Crompton/Havells etc., make 40W well glass light fitting including dismantling the existing fitting, checking, refixing, giving connections etc. at site of work as required. |
| 62 | Supplying, installation, Testing and commissioning of 70 watt LED Well Glass (Clear type) made of high pressure die cast aluminium housing and fixing on truss /wall/pole with suitable clamps and nut & bolts including connection etc., as required (as per latest ISO/IEC Specification)(IP66 protection, Luminar efficacy > 120Lm/W, CRI>75) |
| 63 | Supplying and fixing of 32 mm dia X 1.00 meter long G.I. pipe (medium class) bracket for mounting of LED street light fitting on pole including bending the pipe to the required shape, 2 Nos. 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. |
| 64 | CREDIT ITEMS |
| 65 | Dismantled DBs,switchgears, tumbler switches |
| 66 | Dismantled metal scrap |
| 67 | Dismantled Poles shifting out from depot premises as credit |
| 68 | Dismantled obsolete Tubelight fittings/Street lights/HPSV Lamps with its accessories etc., |