| 1 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 m lead. |
| 2 | For thickness of tiles above 25mm and upto 40mm |
| 3 | Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials upto a lead of 1 kilometer, stacking serviceable materials and unservicaeable materials seperately including cutting reinforcement bars. |
| 4 | Demolishing brick work manually/by mechanical means including stacking of serviceable materials and disposal of unsericeable materials within 50 meters lead as per direction of the Engineer-in-charge. |
| 5 | Dismantling doors, windows and clerestorey window shutters including chowkats, architrave, holdfasts etc. complete and stacking within 50 meters lead. Of area 3.0 Sqm area or below |
| 6 | EARTHWORK |
| 7 | Earth work in excavation by mechanical means(Hydraulic Excavator)/manual means in foundation trenches or drains(not exceeding 1.5m in wiwidth or 10 sqm on plan) including dressing of sides and ramming of bottoms lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m.All kinds of Soil |
| 8 | CONCRETE WORK |
| 9 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering in-All work upto plinth level 1:2:4 (1cement: 2coarse sand : 4graded stone aggregate 20 mm nominal size) |
| 10 | RE-INFORCED CEMENT CONCRETE WORK |
| 11 | Providing and laying in position ready mix plain cement concrete or site batched design mix cement concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana/ordinary portland/portland slag cement, admixture in recommended proportion as per IS 9103 to accelerate/retard setting of concrete, to improve ductility and workability without impairing strength, including pumping of concrete to site of laying, curing, carriage of all leads, but excluding the cost of centering, shuttering, finishing and reinforcements as per direction of engineer in charge, for the following grades of concrete.All works upto plinth level |
| 12 | Concrete of M25 grade with minimum cement content of 330 kg/cum |
| 13 | Reinforced cement concrete work in walls(any thickness),including attached pilasters,buttresses,plinth and string courses, fillets, column, pillars,piers,abutments,posts and struts etc.above plinth level upto floor fivelevel excluding cost of centering,shuttering,finishing and reinforcement: |
| 14 | 1:1.5:3(1 cement :1.5 coarse sand:3 graded stone aggregate 20mm nominal size) |
| 15 | Providing and laying in position ready mix plain cement concrete or site batched design mix cement concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana/ordinary portland/portland slag cement, admixture in recommended proportion as per IS 9103 to accelerate/retard setting of concrete, to improve ductility and workability without impairing strength, including pumping of concrete to site of laying, curing, carriage of all leads, but excluding the cost of centering, shuttering, finishing and reinforcements as per direction of engineer in charge, for the following grades of concrete.All works above plinth level upto floor V level |
| 16 | Reinforcement for R.C.C work I/c straightening,cutting,bending, placing in position and binding all complete.Above plinth level.(Thermo-Mechanically Treated bars) |
| 17 | IN SUPERSTRUCTURE |
| 18 | Brick work with 1st class common burnt clay F.P.S (non modular) brick in superstructure above plinth level upto floor V level in all shapes and sizes in. Cement mortar 1:4 (1cement:4coarse sand) |
| 19 | HALF BRICK MASONRY |
| 20 | Half brick masonry with 1st class common burnt clay F.P.S (non modular) brick in superstructure above plinth level upto floor V level in. Cement mortar 1:4 (1cement:4coarse sand) |
| 21 | Walls : |
| 22 | Roof Walls |
| 23 | Mumty Walls |
| 24 | Parapet |
| 25 | FORMWORK |
| 26 | Foundation,footing,bases of columns etc.for mass concrete. |
| 27 | Suspended floors,roofs,landing balconies and access platform |
| 28 | Columns, pillars,piers,Abutments,posts and struts. |
| 29 | Wall (any thickness) including attached pilaster,buttresses,plinth and string courses etc. |
| 30 | Lintels,beams,plinth beams,girders,bressumers and cantilevers. |
| 31 | Stairs,(excluding landings) except spiral-staircases. |
| 32 | STEEL WORK |
| 33 | Steel work in built up tubular (round,square or rectangular tubes etc.)trusses etc.including cutting,hoisting,fixing in position & applyingpriming coat of approved steel ptimer,including welding and bolted special shaped washers etc.complete.Hot finished welded type tubes |
| 34 | Providing & fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs,beams during laying i/c painting the exposed portion of loops, all as per standard design complete. |
| 35 | In grating,framed guard bars,railing,brackets,gates and similar works. |
| 36 | STEEL/ALUMINIUM WINDOWS |
| 37 | Providing and fixingglazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge(Cost of aluminiumsnap beading shall be in basic itemn):- (A)With float glass panes of 4mm thickness. |
| 38 | Providing and fixingglazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge(Cost of aluminiumsnap beading shall be in basic itemn):-with float glass panes of 5.50 mm thickness |
| 39 | WOOD WORKS |
| 40 | Providing wood works in frames of doors,windows,clearstory windows and other frames wrought,framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately: |
| 41 | Local best quality Teak wood |
| 42 | Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory window including ISI maeked M.S butt hinges bright finished of required size with necessary screws,excluding panelling which will be paid for separately,all complete perdirection of Engineer-in-charge. |
| 43 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts,nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) |
| 44 | Providing and fixing chromium plated brass 100 mm door mortice latch and lock with 6 levers and a pair oflevers handles with necessary screws complete (best make of approved quality). |
| 45 | Providing and fixing ISI marked oxidesd M.S.handles conforming to IS:4992 with necessary screws etc.complete:(100mm) |
| 46 | Providing and fixing bright finishing brass Towerbolts (barrel type) with necessary screws etc. complete.(250x10mm) |
| 47 | (250 X 10 mm) |
| 48 | (100 X 10 mm) |
| 49 | Providing and fixing ISI marked oxidised M.S. Pressed Butt hinges with necessary screws etc. complete.125 x 65 x2.12 mm |
| 50 | Providing and fixing 15mm thick densified tegular edged eco-friendly light weight calcium silicate false ceiling tiles of approved texture of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvansed steel sections (galvanising @ 120 grams per sqm including both side) consisting of main \"T\" runner suitably placed at joints to get required length and of size 24 x 38 mm made from 0.33 mm thick (minimum) sheet,spaced 1200 mm centre to centre to form a grid of 1200 x 600 mmand secondary cross \"T\" of size 24 x 28 mm made from 0.33 mm thick (minimum) sheet to be interlocked at the middle of the 1200 x 600 mm panel to form grid of size 600 x 600mm , redting on periphery wall, partitions on a Perimeter wall angle pre-coated of size (24 x 24 s 3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calcium silicate ceiling tiles of apptoved texture in the grid, including cutting/ making opening for services like diffusers, grills, light, light fitting, fixtures, smoke detectors etc. wherever required. Main \"T\" runner to be suspended from ceiling using G.I. slotted cleats of size 25 x 35 x 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 0.8 mm, spaced at 1200 mm centre along main \"T\",bottom exposed with 24mm of all Tsection shall be pre-painted with polyster baked paint,for all heights,as per specifications, drawing and as directed by Engineer-in-charge. |
| 51 | FLOORING |
| 52 | Providing and Laying vitrified tiles in floor tiles in different sizes (thickness to be specified by the manufacturer)with water absorption\"s less than 0.08% and conforming to IS:15622 of approved make in all colours and shades,laid on on 20mm thick cement mortar 1:4(1cement:4 coarse sand) including grouting thejointingwith white cement and matching pigments etc.complete. Size of Tile 600x600 mm |
| 53 | Providing and Laying vitrified tiles in floor tiles in different sizes (thickness to be specified by the manufacturer)with water absorption\"s less than 0.08% and conforming to IS:15622 of approved brand & manufacturer in all colours and shades,laid on on 20mm thick cement mortar 1:4(1cement:4 coarse sand) jointingwith grey cement slutty @3.3kg/sqm including grouting the joints with white cement and matching pigments etc.The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel,plier wedge,clips of required thickness,leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size.Size of Tile 600x600 mm |
| 54 | Providing and Laying ceramic glazed floor tiles 300 x 300mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make in colours such as white, ivory, grey, fume red, brown laid on on 20mm thick cement mortar 1:4(1cement:4 coarse sand) including pointing the joints with white cement and matching pigments etc., complete. (Terraces) |
| 55 | Marble Stone flooring with 18mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) over 20mm (average) thicki base of cement mortar 1 : 4 ( 1cement : 4 c/sand) laid and jointed with grey cement slurry including rubbing and polishing complete with (External Lift Walls) |
| 56 | Udaipur green Marble |
| 57 | Tile work in skirting, risers of steps and dado (upto 2 m height) over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with pigment of matching shade complete. Marble tiles (polished) Raj Nagar. 8 mm thick. |
| 58 | MARBLE WORK (CLADDING ON LIFT WALLS) |
| 59 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1 : 4 ( 1 cement : 4 c/sand) with joints treatedwith white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 60 | Area of slab over 0.50 sqm |
| 61 | PROFILE SHEET ROOFING (DYNA) |
| 62 | Proving corrugatrd G.S. Sheet roofing including vertical/curved surface fixed with polimer coated J or L hook,bolts and nuts 8 mm diameter with bitumen and G.I.limpet washers or with G.I.limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/vertical or curved surface excliding the cost of purlins,rafters and trusses and including cutting to size and shape wheever required. |
| 63 | 0.80mm thick with zinc coating not less than 275gm/sqm |
| 64 | Providing ridges or hips of width 60 cm over all width plain G.S.sheet fixed with polymer coated J or L hooks,bolts and nuts 8mm dia.G.I.limpet and bitumen washers complete. |
| 65 | 0.80mm thick with zinc coating not less than 275gm/sqm |
| 66 | FINISHING |
| 67 | Internal wall plaster 15 mm cement plaster on rough side of single or half brick wall of mix: thick with cement mortar 1:4 (1 cement :4c/sand ) |
| 68 | External wall plaster 12 mm cement plaster of mix.1:4 (1cement :4 c/sand) |
| 69 | Providing & fixing on wall face unplasticised Rigid PVC rain water pipe conforming IS:13592 Type A including jointed with seal ring conforming to IS:5382 leaving 10 mm gao for thermal expansion,(i)Single socketed pipes.75 mm diameter |
| 70 | Providing & fixing M.S. holder bat clamps of approved design to C.I or S.C.I,rain water pipes embedded in & i/c cement concrete blocks10x10x10 cmof 1:2:4 mix (1 cement: 2 coarse sand :4 hard stone ballast 20 mm & down gauge).and cost of cutting holes and making good the walls etc: 100 mm dia. |
| 71 | CEMENT PAINTING - ORDINARY |
| 72 | Applying one coat of water thinnable cement primer of approved brand and manufagture on wall surface.Water thinnable cement primer |
| 73 | Finishing walls with textured exterior paint of required shade:New work (Two or more coats applied @ 3.25 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20 kg/10sqm. |
| 74 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer,over the plastered wall surface to prepare the surface even and smooth complete. |
| 75 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications : Two or more coats applied @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @0.75 ltr/10 sqm. |
| 76 | APPLYING PRIMING COAT |
| 77 | Panting with oil type wood preservative of approved brand and manufacture:New work (Two or more coats)plastic emulsion paint of approved quality on new work except walls to give an even shade. |
| 78 | With ready mix pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 79 | SUPERIOR GLOSS ENAMEL PAINT |
| 80 | Painting with synthetic superior enamel paint of approved brand and manufacture to required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. on new steel work to give an even shade. |
| 81 | As in item no.33 ( for door/window frames and shutters) |
| 82 | Truss, Fascia, Stair Railings and guard bars. |
| 83 | Wall painting with acrylic emulsion paint, having VOC ( Volatile Organic Compound) content less than 50 grams/litre, of approved brand and manufacture, including applying additional coats whereever required, to achieve even shade and colour. Two Coats |
| 84 | Wall paint with plastic emulsion paint of approved brand and manufacture to give an even shade.Two or more coats on new work |
| 85 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other plugs and screws or with fixing clips, or with expansion hold fasteners includingsections of approved make conforming to IS:733 and IS:1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gaps at junctions,at top bottom and sides with required EPDM rubber/ Neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass /stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge(Glazing and pannelling to be separately ):-For shutters or doors,windows&ventilators includingproviding and fixind hinges/pivots and making provision for fixing of fitting whereever required including the cost of EDPM rubber/neoprene gasket required(fittings shall be separately). |
| 86 | Providing and fixing glazing in aluminium door, window, ventilator, shutter and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item). With float glass panes of 4.0 mm thickness. |
| 87 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. |
| 88 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively withutomatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern |
| 89 | Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. |
| 90 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P.brass pillar taps |
| 91 | Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge. 110mm dia. |
| 92 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm nominal outer dia Pipes |
| 93 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 94 | Providing and fixing brass bib cock of approved quality : 15 mm nominal bore |
| 95 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to thedumping ground within 50 metres lead : With cement mortar 1:4 (1 cement: 4 fine sand) |
| 96 | Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete |
| 97 | 10 litre (full flush) capacity-white |
| 98 | Wall cladding with HPL Sheet 6mm thick as per selected colour and design with all required wall framing with aluminium tube including material and labour charge at site + plus 15% contractors profit i.e. @ Rs 550/- + 15%*550=Rs 632.50/Sqm |
| 99 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other plugs and screws or with fixing clips, or with expansion hold fasteners includingsections of approved make conforming to IS:733 and IS:1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gaps at junctions,at top bottom and sides with required EPDM rubber/ Neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass /stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge (Glazing and pannelling to be separately ) :-For shutters or doors,windows & ventilators including providing and fixind hinges/pivots and making provision for fixing of fitting whereever required including the cost of EDPM rubber/ neoprene gasket required (fittings shall be separately). |
| 100 | A).Anodised aluminium (anodised transparent or dyed to required shade accordingto IS: 1868, Minimum anodic coating of grade AC 15) |
| 101 | SH : IEI of the Building |
| 102 | Wiring Item |
| 103 | Wiring for light point / Fan point/ Exhaust Fan ponit / Call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in pvc casing and capping with modular type switch, modular plate suitable sizeG.I. Box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc. as reqd. |
| 104 | 3. Group C |
| 105 | Wiring for circuit / sub- main wiring along with earth wire with ( the following sizes of )PVC insulated copper conductor single core cable in PVC casingand capping etc as reqd. |
| 106 | 2. 2x2.5mm2 + 1x2.5mm2 earth wire |
| 107 | 3. 2x4mm2+ 1x4mm2 earth wire |
| 108 | 4. 2x6mm2+ 1x6mm2 earth wire |
| 109 | Wiring for circuit / sub- main wiring along with earth wire with the following sizes ofPVC insulated Al. conductor single core cable in PVC conduit on surface/in recess etc as reqd. |
| 110 | 2x25 mm² +1x16mm² as earth wire |
| 111 | Fixing Items |
| 112 | 76.2mmX76.2mmconical round plate |
| 113 | S/Fbrass batten /angle holder i/c conection etc as reqd. |
| 114 | S/F 8W CFL lamp. |
| 115 | S/F 3 pin 5 amp ceiling rose on the existing junction box /wooden block i/c connection etc as reqd |
| 116 | S/Fsuitable size G.I box with modular plate and cover in front on surface or in recess i/c P/F 3 pin 5/6 amp modular socket outlet 5/6 amp modular switch , connection painting etc as reqd. ( for light plugs to use in non-residential building). |
| 117 | S/Fsuitable size G.I box with modular plate and cover in front on surface or in recess i/c P/F 6 pin 15/16 and 5/6 amp modular socket outlet 15/16 amp modular switch , connection painting etc as reqd. |
| 118 | S/F 20 amp. 240 SPN industrial type socket outlet with four pole and earth , metal enclosed plug top along with 10 amp. \"C\" series TP MCB in sheet steel enclosure on surface or in recessed with chain metal cover for the socket outlet and complete with connection testing and commissioning etc as reqd |
| 119 | Supplying & fixing stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc as reqd. |
| 120 | S/F 48\"\" Sweep (1200mm) A.C ceilling fan complete with down rod canopy, 3 (three) blades but without regulator etc as reqd.( Make Bajaj/Usha or simillar) |
| 121 | S/F 305mm sweep exhaust fan complete with all accessories i/c connection etc as reqd. |
| 122 | S/F 1 tone capacity split type air condition (Diamond, 3 star 5G 28, G-SC 12 FD3 WJH) complete with Indo voltage stablizer, automATIC 3 kva (140-280 FOR 1 Ton |
| 123 | S/F 300 mm diawall mountingFancomplete with all accessories etc. as reqd. |
| 124 | S/F 12 way (2+12 way) double door single pole and neutral , prewired, sheet steel MCB distribution board ,240 on surface /recessed complete with loose wire box, terminal blocks, tinned copper bus bar , neutral link, earth bar , din bar , detachable gland plate , interconnection , including powder coat painting, earth etc as reqd ( but without MCB /RCCB/Isolator) |
| 125 | Supplying and fixing 5 amp to 32amp rating 230 V \"B\" series MCB for lighting and other load of ( following poles ) in the existing MCB DB complete with connection testing and commissioning etc as reqd. |
| 126 | 1.Single pole |
| 127 | S/F( following rating) double pole 240v isolator in the existing MCB DB complete with connection ,testing and commissioning as reqd. |
| 128 | 1. 40 amp |
| 129 | Eraction of street light standard pole of length exceeding 4.5 mtrs but not exceding 6.5 mtrs in cement concrete 1:3:6(1 cement :3 coarse : sand:6 Graded stone aggregate 40 mm nominal size ) foundation i/c excavation and refilling etc. as reqd. |
| 130 | S/F steel tubular pole 4.5 mtrs long 65mm dia with base plate i/c painting etc. as reqd. |
| 131 | S/F 2.5 mtrs. Long G.I bracket for fixing of street lamp. |
| 132 | Eraction of steel tubular pole of length not less than 8 mtrs but not exeeding 10 mtrs in cement concreet 1:3:6 (1 cement:3corase sand :6 graded stone agtt. 40 mm nominal seize) foundation i/c excvation and filling etc as reqd. |
| 133 | 8 meter long Steel tubular pole (410 SP-14) |
| 134 | Earthing with copper earth plate 600mmx600mmx6mm thick i/ci/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.( but without charcoal or coke and salt ) as reqd. |
| 135 | P/F 25mmx25mm copper strip in 40mm dia G.I pipe from earth electrode as reqd. |
| 136 | Extra for using salt and charcoal for G.I or copper palte earth electrode as reqd. |
| 137 | P/Fearth bus of 25mmx25mm copper stripon surface or in recessed for connection etc. as reqd. |
| 138 | S/F LED SurfaceDownlighter Philips ,12 W |
| 139 | FLOOD LIGHT, HPFLP 100 W, LHEPARU17J101 |