| 1 | Supplying and fixing of following size of PVC junction box in required position along the line of PVC conduit as required. Make:Avonplast/Vijaya:- 20mm Junction Box three way |
| 2 | Supplying and fixing of following size of PVC junction box in required position along the line of PVC conduit as required. Make:Avonplast/Vijaya:- 25mm Junction Box three way |
| 3 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface / recessed steel / PVC conduit as required - 2 X 1.5 |
| 4 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface / recessed steel / PVC conduit as required - 3 X 1.5 |
| 5 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface / recessed steel / PVC conduit as required -3 x 2.5 sq.mm |
| 6 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface / recessed steel / PVC conduit as required -3 x 4 sq.mm |
| 7 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface / recessed steel / PVC conduit as required -5 x 4 sq.mm |
| 8 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface / recessed steel / PVC conduit as required -3 x 6 sq.mm |
| 9 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required - 20mm |
| 10 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required - 25mm |
| 11 | Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 5/6 A switch |
| 12 | Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 15/16 A switch |
| 13 | Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 3 pin 5/6 A socket outlet |
| 14 | Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 6 pin 15/16 A socket outlet |
| 15 | Supplying and fixing two module stepped type electronic fan requlator on the existing modular plate switch box including connections but excluding modular plate etc as required |
| 16 | Supplying and fixing following size / modules , GI box alongwith modular base & cover plate for modular switches in recess etc. as required - 4 module (125 mm x 75 mm) |
| 17 | Supplying and fixing following size / modules , GI box alongwith modular base & cover plate for modular switches in recess etc. as required - 6 module (200 mm x 75 mm) |
| 18 | Supplying and fixing following size / modules , GI box alongwith modular base & cover plate for modular switches in recess etc. as required - 8 module (125 mm x 125 mm) |
| 19 | Supplying and fixing following size / modules , GI box alongwith modular base & cover plate for modular switches in recess etc. as required - 12 module (125 mm x 125 mm) |
| 20 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc.as required - 4 module |
| 21 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc.as required - 6 module |
| 22 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc.as required - 8 module |
| 23 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc.as required - 12 module |
| 24 | Supplying and fixing 3 pin , 5 A ceiling rose on the existing junction box / wooden block including connection etc as required |
| 25 | Installation , testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable etc as required |
| 26 | Supplying and fixing PVC batten / angle holder including connection etc.as required. |
| 27 | Supplying and fixing following way , horizontal type three pole and neutral , sheet steel , MCB distribution board , 415 V, on surface / recess , complete with tinned copper bus bar , neutral bus bar , earth bar , din bar, Interconnections , powder painted including earthingetc. as required (but without MCB / RCCB / Isolator ) 4way (4+12) , double door |
| 28 | Supplying and fixing following way , single pole and neutral , sheet steel , MCB disribution board , 240 V, on surface / recess , complete with tinned copper bus bar , neutral bus bar , earth bar , din bar , interconnections , powder painted including earthing etc. as required (But without MCB / RCCB / Isolator) - 8 way (4+24), double door |
| 29 | Providing and fixing of sheet steel, TP&N switch Rewirable porcelain fuse unit, 415volts including drilling holes on the board, connections, earthing the body etc. as required. 63 Amps Triple pole main switch.Make:Standard/Havells:- |
| 30 | Supplying and fixing 5 A to 32 A rating , 240/415 V, 10 kA, \"C\" curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc .as required. - Single Pole |
| 31 | Supplying and fixing 5 A to 32 A rating , 240/415 V, 10 kA, \"C\" curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc .as required. - Double Pole |
| 32 | Supplying and fixing following rating , double pole , 240 V, Isolator in the existing MCB DB complete with connections , testing and commissioning etc.as required - 100 A |
| 33 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet , with 2 pole and earth , metal enclosed plug top alongwith 20 A \"C\" curve , SP,MCB, in sheet steel enclousure , on surafce or in recess , with chained metal cover for the socket out let and complete withconnections , testing and commissioning etc.as required |
| 34 | Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6 mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc .as required - 63 A TPN |
| 35 | Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6 mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections , earthing etc .as required - 100 A TPN |
| 36 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required |
| 37 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc.as required - Upto 35 sq.mm |
| 38 | Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 4 X 25 sq.mm |
| 39 | Supply and fixing of wall mount bracket of 50 mm dia GI pipe suitable for SVL / MH fittings with clamp , bolts and nuts as required |
| 40 | Supplying of 3 star rated wall mountable split type 1.5 ton capacity Air conditioner unit ( as per IS 1391 part 2) with following specification material for body for indoor unit Abs: Normal cooling capacity (K.cal/Hr): 5000-5500 power consumption max(wits): 1400-1500 watts mini room discharge Air clow (CF/Hr) 550-600. Air conditioner shall be suitable for 230V 50Hz operation and capable of performing the function as cooling air circulating and filtering and confirm to IS:1061\" part carrier split AC unit Model : NX series. The rate inclusive of all taxes. |
| 41 | Installation charges for split type Air Conditioner. |
| 42 | Civil and angle works indoor and out door units. (including materials and labour charges). |
| 43 | Supply and fixing 72 watts LED street light fittings (Make: Crompton) |
| 44 | Supply and fixing of 4 KVA volatge stabilizer make : Microtek (Double booster). The rate is inclusive of all taxes. |
| 45 | Supplying of 4 x 16 sqmm armoured aluminium U.G cable 1.1KV grade at site. Make: Polycab / Finolex / Havells. |
| 46 | Supplying of 4 x 50 sqmm armoured aluminium U.G cable 1.1KV grade at site. Make: Polycab / Finolex / Havells. |
| 47 | Supply and fixing of 18-24W recess / surface mounted round / square type LED luminaire of size 9\" x 12\". Make: Wipro / Jaquar/Philips. |
| 48 | Supply and fixing of 30-36W slim type recess mounted square LED luminaire of size 2\" x 2\". Make: Wipro / Jaquar/Philips. |
| 49 | Supplying of ceiling fan sweep 1200mm Fushion-50 Energy saving fan five star. Make: Havels. |
| 50 | Supplying and fixing 4 feet, 20, 24W system wattage LED tube light fitting with aluminium exturded heat sink and high efficiency polycarbonate diffuser suitable for surface mounting with on site warranty for three years make: Philips / Wipr/Havells/Crompton) |