| Sl. No. | Item Description |
| 1 | M&L for for carrying out water proofing treatment of sunken floor as under:-(i)The concrete/ wall surface shall be cleaned throughly of all laitance , loose particles, dust , grease etc. any friable unsound area shall be chipped, cleaned and there after pre-welted to a saturated surface dried conditions.(ii) In case of potholes , superficial cracks found , the same shall be repaired with polymer modified mortar 1:3 ( 1 cement and 3 coarse sand )using Dr fixit pidicrete URP 301/Sikka latex or equivalent in Asian paints/ Forsoc as admixture @ 10% of cement content and the same shall be applied on vertical area after removing of plaster upto 2 ft height (iii)On the prepared surface , apply a primer coat of Sika latex / Dr. fixit pidicrete URP 301 or equivalent in Asian paints/ Forsocmodified cement slurry 1:4:8 (1 admixture : 4 water : 8 cement) , after prewetting the substrate @ 2 kg/sqm .(iv)the surface thus prepared shall dampen upto saturation and apply two coats of sika top seal 107 or equivalent in Dr fixit piddilite/Asian paints/forsoc ,acrylic modified water proofing coating on the entire area @1.5 kg/sqm (each coat) Scond coat shall be applied after 6-8 hrs after the first coat and in the direction right angle to the previous coat . the water proofing should be taken to a vertical height of minimum 600 mm above .(v) Apply open woven glass fiber mesh of sika Fab 1 or equivalent in Dr fixit piddilite/Asian paints/forsoc, 150 mm wide strip over the PCC benching (Gola) whilst the first coat is wet and then apply scond coat . cure the hydrosentapplication ( Minimum 6-8 hrs drying) for a minimum 3 to 5 days .(vi)Apply a protection layer of 10 mm thick plaster made of 1:4 cement sand mortar admixed with integral water proofing compound Sika plastocrete plus/ Dr fixit piddilite LW plus or equivalent in asian paints/ forsoc @ 200 ml/bag of cement , applied over the water proofing coating .Note;The rate include the cost of demolition of exiting floor , sub base , PCC/ hardcore filled under floor , removal of debris , removal and replacement of damaged CI/PVC pipes, floor,Nahani traps complete all as specified and directed. Notes:-(i) The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators duly approved by GE in writing. (ii)5% amount of the total amount of water proofing treatment shall be retained as a guarantee (on account of any defect raised/noticed during a period of ten years) and shall be released after 10 years of completion of work. However contractor may deposit the FDR of same amount in favour of GE. If contractor fails to rectify the defect pointed out during this period , the defect shall be got rectified at contractor\"s risk and cost and the payment shall be made from the amount kept reserved or by encashing the FDR deposited by the contractor as guarantee. The contractor\"s quoted rates for this item shall deemed to be inclusive of this aspect.(iii) Cost of WPC shall be deemed to be included in the quoted rate.. |
| 2 | M&L for Plain Cement Concrete (1:5:10) type E2, using 40 mm graded mechanically crushed stone aggregate as in sunken slab filling, mass concrete etc., complete all as specified and as directed. |
| 3 | Disconnecting existing PVC water tank of capacity not exceeding 500 ltrfixed on roof by setting aside (or lowering, if required) for cleaning and removing all scale and dirt from tanks and from mouths of circulating pipes etc and hoisting/refixing/reconnecting in same/new position including removing Existing painting andwriting date of cleaning on each tank with white/Blackpaint, height/size of letters/figures not less than 10cm in height, and refixing existing serviceable ball valves complete all as specified and directed by Engr -In Charge .”Note :-After cleaining oftank contractor shall obtained singnatureof user/Repwittensing cleaning of tankand produce same to the Engr -in Charge |
| 4 | Disconnecting existing PVC water tank of capacity exceeding 500 ltr but not exceeding 1000 ltr fixed on roof by setting aside (or lowering, if required) for cleaning and removing all scale and dirt from tanks and from mouths of circulating pipes etc and hoisting/refixing/reconnecting in same/new position including removing Existing painting andwriting date of cleaning on each tank with white/Blackpaint, height/size of letters/figures not less than 10cm in height, and refixing existing serviceable ball valves complete all as specified and directed by Engr -In Charge .”Note :-After cleaining oftank contractor shall obtained singnatureof user/Repwittensing cleaning of tankand produce same to the Engr -in Charge |
| 5 | Taking down unserviceable GI tubing, supply and fixing new 15 mm bore Galvanized Iron tubing, medium grade, with all fittings, such as Tee, elbows, sockets, unions, short pieces and application of bituminous paint in concealed portion, fixed to wall/ ceiling or laid on floors, complete all as specified and as directed.Notes: Serviceable Taps, valves in any shall be removed before taking down pipe and same shall be re-fixed while providing new pipe,ii) Cutting chases for concealed piping shall be measured and paid separately under respective item. |
| 6 | Taking down unserviceable GI tubing, supply and fixing new 20 mm bore Galvanized Iron tubing, medium grade, with all fittings, such as Tee, elbows, sockets, unions, short pieces and application of bituminous paint in concealed portion, fixed to wall/ ceiling or laid on floors, complete all as specified and as directed.Notes: Serviceable Taps, valves in any shall be removed before taking down pipe and same shall be re-fixed while providing new pipe,ii) Cutting chases for concealed piping shall be measured and paid separately under respective item. |
| 7 | Refixing 20mm bore water tubing surface/concealed in same/new location after cleaning and application of bituminous paint on concealed portion of tubingincluding cutting & threading pipe and provision of additional fittings such as socket, tee, elbow, union (if required) complete all as specified and directed.Note : i) Taps, valves if any shall be removed before taking down pipe.ii) Cutting chases and making good shall be measured and paid separately |
| 8 | Cutting chases pinning in making good for brick walls to facing where required and pointing in cement mortar 1:3 to ends or edges of concealed water tubing and similar work including making good cutting not exc 10CM girth. Complete all as specified and directed. |
| 9 | Demolition of Brickwork or stone boulder masonry/PCC block masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework & precast concrete articles and disposing off rubbish outside MD land complete all as specified and directed. |
| 10 | M&L for brick work with sub class Bbricks, straight or curved on plan exceeding 6 m meanradius , built in cement mortor 1:6 complete all as specified and directed. |
| 11 | M&L for brick work with sub class\"B\" bricks,straight or curved on plan to any radius in half brick thick wall built in CM 1:4 complete all as specified and directed. |
| 12 | Taking down cement plastering of any thickness on brick, concrete or stone walls, partitions, ceilings etc including raking out joints, hacking for key, scrubbing down with water etc, and rmoving debris out side MD land complete all as specified and as directed. |
| 13 | M&L for 15 mm thick rendering on brick wall or concrete wallorany surface in cement mortar 1:6on fair face/other than fair face and finishing the surface with even and smooth without using extra cement all as specified and as directed. |
| 14 | M&L for Rendering 15mm thick on fair face/other than fair face of brick work or concrete any surface in CM 1:4 finished even and smooth without using extra cement upto triple storey building, mixing with approved water proofing compound, for roof facia, chajjas, etc.and finishing the surfaces even and smooth without using extra cement complete all as specified and as directed. NOTE:-(i) Height of the bldgs is Appx Up to 12 mtr incl Quoted Rates, Cost of necessary scaffolding and security provision of labour shall be deemed to be included in quoted rate. (ii) Supply only WPC will be measured and paid separately under relevant item of BOQ. |
| 15 | M&L for 5mm thick rendering on ceilings in cement mortar 1:3 and finishing the surface with even and smooth without using extra cement all as specified and as directed. |
| 16 | M & L for rough cast plaster incl 15 mm thick CM 1:3 on brick work or concrete surface complete all as specified in SSR Part -1 clause 14.22 complete all as specified . Note:Rough cast plaster finish shall be as follow :- After applying the under coat cement mortar 1:3 and while it is still inplastic state the rough cast mixture consisting of crushed stone or fine gravel aggreagte ( Which is generally of size between 6 to 12 mm depanding on the texture required mixed with coarse sand and cement in the ratio of 1:1:1 shall be applied and finished even . The mix of cement and sand shall be made slightly wetter than normal for rendering to ensure the larger aggregate are throughly covered. Note :Area to be plastered may require to be carried out up to height of 15 m, cost of necessary scaffolding and security provision of labour shall be deemed to be included in quoted rate. |
| 17 | M&L for Preparation of new or previously untreated plastered wall surfaces of any description not otherwise described and applying two coats of oil bound distemper over a coat of alkali resistant primer over and including 1 mm thick wall care putty, complete all as specified and as directed.Note : Quoted rate shall deemed to include for cost of wall care putty. |
| 18 | M&L for preparation of new plastered surfaces and applying three coats of white wash on ceilings complete all as specified and directed |
| 19 | M&L for Preparation of newly plastered sufaces of walls and applying two coats of weather-proof antifungal exterior emulsion paint over a coat of alkali resistant primer,over wall carePuttyupto triple storey building, complete all as specified and directed. Note: Item may be executed upto 15.00m height. cost of necessary scaffolding and security provision of labour shall be deemed to be included in the quoted rate. |
| 20 | M & L for applying two coats of cement based paint on newly plastered or unplastered wall surface including preparation ofsurfaces, complete all as specified and directed. |
| 21 | S&Fin repair 20 mm dia 3-layer PP-R polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stablised and anti-microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified. Make : SMFC, SAFE, WETFLOWNote:- Cutting chases for concealing the pipes & fittings etc wherever required andmaking good, disturbed surface in Cement mortar 1:3 complete shall be included in the quoted rate. |
| 22 | S&F in repairfor Wall Hung Water Closetof size365 X 360 X 545 mm including supply and fixing soft close seat cover (PP), hinges & all accessories complete all as specified and directed by Engr-in-Charge. Make : Jaquar Cat No.FLS-WHT-5951/ Kohler Cat Part No. K-18131IN-S/Johson E-11050PW (White in colour) for WC or equivalent as approved by GE. |
| 23 | S&F Slim Concealed Cistern with Floor Mounting Frame, Installation Kit and Drain Pipe Connection Set for Wall Hung WC (Without Flush Control Plate)complete all as specified and directed by Engr-in-Charge. Make : Jaquar Cat No.CIB-WHT-31801011XF/Grohe rapid cat part No. SI-38536001/Kohler Model No. K-4178IN-2S with frame matching to the model. |
| 24 | S&F Control Plate Segment White/Chrome Slim for Concealed Cistern complete all as specified and directed by Engr-in-Charge. Make : Jaquar Cat No. CIS-CHR-31181810X/Grohe ASIN B014X33CUY/Johnson Chrome- G3471PC |
| 25 | S&F in repair table top wash hand basin , of size 190mm x 600 mm x 435 mm including 32 mm size brass chromium plated waste coupling all fixing assoseriescomplete all as specified and directed by Engr-in-Charge. |
| 26 | S&F in repair table top wash hand basin , of size 185mm x 465mm x 475 mm including 32 mm size brass chromium plated waste coupling all fixing assoseriescomplete all as specified and directed by Engr-in-Charge. |
| 27 | S&F8mm thick toughen glass ( 125 mm to 250 mm wide) as in shelves incl all necessary stainless steel fittings to fix on wall complete all as specified and directed by Engineer-in-Charge. |
| 28 | S&F Shower panel made of Anodised Aluminum structure, 3 adjustable vertical jets , Integratedshower head(8”Round) with Thermostatic mixer with diverter , Hand shower with flexible hose and Button Spout Connecting Hose Curve Model Curve complete all as specified and directed by Engineer-in-Charge.Code:JPL-SLM-JA021 Make : Jaquar /or equivalent in HANSGROHE or as approved by GE. |
| 29 | S&F 12mm thick toughend Fixed Glass Partition in front of cabins and also glass fixed with required etching, S.S. clamps on sides and top & S.S. u-channel in floor as per detail drgs. And complete all as specified and directed. |
| 30 | S&F fully Glazed frame-less door made out of 12 mm thick toughened glass edge polished fixed with required etching stainless steel patch fittings at top & bottom and floor springs and lock of ozone make . The door shall have the lock at bottom, and 600 mm length stainless steel brush finish handles of 25 mm dia complete all as specified Note :- quoted rates shall be deemed to be inclusive of all fittings & fixtures |
| 31 | M&L for 75mm thick PCC (1:3:6) type C-1 using 20mm graded mechanically crushedstone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10mm wide, 30mm deep joints at the rate of 3.00 mt centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified and as directed.Notes :- (i) The unit rate quoted shall be deemed to include for providing the concrete in alternate bays not exceeding 3 Mtrs length,10 mm wide. (ii)30 mm deep joints between the bays shall be provided which shall be filled with mastic filling with hot bitumen 85/25 grade and 1:2 mix volume. |
| 32 | Taking down cement plaster and decayed concrete of any description, upto triple storey of building, from roof projection, chajja etc and making good the decayed portion with cement mortar 1:3 mixed with water proofing compound as per manufacturers instruction or PCC 1:2:4 type B-O (using 12.5mm graded crushed stone aggregate) including necessary form work and finally finished the surface with 15mm thick cement plaster in CM 1:3, complete all as specified anddirected.Note:(i)water Proofing Compound Incl Quoted Rate (ii) Item may be executed upto 12mm height(iii)Cost of necessary scaffolding & security provision of labour shall be deemed to be included in quoted rate. |
| 33 | Taking down chowkats or frame without taking off shutterfrom the frame not exceeding 1.50 Sqm each from the frame and removing from site, including cutting holes for taking out hold fasts and making good disturbed portion in cement mortar 1:3, complete all as specified and as directed |
| 34 | Taking down chowkates / frame without taking off shutter exceeding 1.50 Sqm not exceeding 4 Sqm each. from the frame and removing from site, including cutting holes for taking out hold fasts and making good disturbed portion in cement mortar 1:3, complete all as specified and as directed |
| 35 | Taking down Shutters of any description exceeding 1 sq. m and not exceeding 2 sq. m each, complete all as specified and directed. |
| 36 | S&F ofFactory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 28 mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ ricehusk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant Fixing stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws, complete all as specified and directed. |
| 37 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door Frames/Chowkhat of size 100 x 60 mm single rebate comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant, complete all as specified and directed. Note: For WPC solid door frames, minus 5mm tolerance in Dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 38 | S&F Factory made solid PVC Chowkhat /Door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm thick rigid PVC foam sheet coloured, reinforced with 19x19mm MS square tube of 19 gauge including rubber gasket, PVCfasteners, screws, brackets as per SSR Part –II (2020) complete all as specified andas directed. |
| 39 | S&F for Factory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stile:),With Wood Free EPS with 2,4 or 6 raised panel design with 2 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face, supplying & fixing in frame at site as per specification & drawin complete all as specified and directed. |
| 40 | S & F 35 mm thick plain framed panelledfactory made shutters(two panel) with IInd class hardwood rail and style with lock rail and panel of 12 mm BWP commercial ply with commercial vaneer on both faces.The size of rail and style as per IS - 1003 Part - I , kiln seasoned and chemically pressure treated complete all as specified and as directed. |
| 41 | S&F 35mm thickmm thick flush shutter, solid core construction with block board core and ply wood face panels, commercial type on both side, complete all as specified & directed. Notes: The rates for flush shutters include for the provision of suitable blocks for taking mortice locks, latches, or other fittings all as specifed and directed. |
| 42 | S & F 35mm thick IInd class hardwood glazed and skeleton shutters open rebated and prepared to receive gauge (without sash bars)edges of framingplain, chamfered or round fitted with cut and mitred beads for securing wire gauge sizes of members as specified in SSR Part-I section 8 clase 8.24(a) of shutters |
| 43 | M&L,Mild steel framed work such as in doors or gates of angle, or tee sections with gusset plates, rails, braces,etc. completely drilled for fixing of steel sheeting or other covering, doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging doors fittings (includingof steel sheeting or other covering, running rails and guides) and handing also fastening and fixing complete Gde Fe 410 - W (Grade-E- 250) quality-A complete all as specified and as directed.ll as specified and directed. |
| 44 | Repair/Rescuing, easing and adjusting wooden door shutter of any description without taking off shutter from the frame, area of shutter exceeding 1.00 Sqm but not exceeding 2.00 Sqm each, including making good the disturbed area as per existing, complete all as specified and directed. |
| 45 | Taking down boards of any description and any size as in shelves complete all as specified and directed. |
| 46 | M&L for 18/19mm thick one side prelaminated particle board, interior grade, with decorative choice laminate and fixed with screws to steel/timber frame work including provision of 6mm thick teakwood edging etc complete all as specified and directed |
| 47 | M & L for applying two coats of synthetic enamel paint over a coat of pink primer including preparation of previously untreated or new wooden surfaces exceeding 10 cm in width or girth complete all as specified and as directed. |
| 48 | S & F in fancy type stainless steel handle of size 100 mm longcomplete all as specified and as directed |
| 49 | S&F in 40mm dia, cupboard knobs fixed with nut, screw & washer of mild steel, bright finished, complete all as specified and directed. |
| 50 | S&F steel window (box type) factory fabricated, double shutter (glazed and wire gauzed) with side hung shutters including pintle type hinges, steel handles fabricated type for each leaf duly welded, mild steel barrel tower bolts 150mm size (02Nos for each leaf) duly welded, with glazing bars dovetailed or welded including MS fillets, welding with and including 8mm dia Squareguard bars with one shop coat of red oxide zinc chrome primer overall complete all as specified and as directed Notes:(i) Windows shall be fabricated as per CE Palam drawing No. TD-219 Sh 1/3 to 3/3 dated 02 Jan 2007 (updated up to date) and these drawings shall be referred at the O/o the GE (AF) Ambala(ii) Glazing and wire gauge will be measured and paid separately under respective items herein(iii) Any other sundries, etc. as required at site shall be deemed to be included in the quoted rate(iv) Cost of guard bars shall be deemed to be included in the quoted rate. |
| 51 | S&F steel ventilator with top hung shutter including hinges peg stay to receive glazing or gauzing and one coat of primer including fixing of hold fast size 25 x 5 mm of flat iron etccomplete all as specified and directed. |
| 52 | M&L for Preparation of newly steel surfaces of any description over 10 cm width or girth & applying two coats synthetic enamel paint complete all as specified and directed. |
| 53 | Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and remove the debris outside of MD land, complete all as specified and directed. |
| 54 | S&F 3 mm thick sheet glass ordinary quality not exceeding 0.50 sqm each pane and fixed with oil putty or with wooden beading in square etc complete all as specified and directed. |
| 55 | S & F3mm thick pin head glass and glazing with oil putty, or beading and necessary clips as square not exceeding 0.5 Sqm in each pane complete all as specified and directed. |
| 56 | S& F Galvanised mildsteel wire cloth 0.56 mmnominal dia of wire and average width of aperature 1.18mm as in gauze door /window/ventilators shutters complete all as specified and directed |
| 57 | S & F in repairs galvanised mild steel wire cloth, 0.56 mm nominal dia of wire Stainless steel wire cloth, and average width of aperture 1.18mm and fixed with stainless steel wire staples complete all as specified and directed |
| 58 | S & F Aluminium anodized barrel tower bolts of extruded section, 150 mm long complete all as specified and directed. |
| 59 | S & F Aluminium anodized cast type handles 150mm long complete all as specified and directed. |
| 60 | S&F SS butt hinges medium weight of size 100 mm complete all as specified and directed. |
| 61 | S & F 12 mm dia aluminium alloy, anodised, sliding door bolt with hasp, staple bolt type and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections 300 mm long all as specified and as directed. |
| 62 | S&F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised with width of flaps (When open) 30 mm, complete all as specified and directed. |
| 63 | S & F magnetic ball catches of standard type fixed complete all as specified and as directed |
| 64 | S & F 100 mm long Mild steel medium weight cold rolled butt hinges and fixed with screw/welded to frames etc complete all as specified and directed |
| 65 | S&F in repairs 20mm dia fancy type powder coated (tint as approved) mild steel of wall thickness 1mm (min) curtain rods / towel rails, etc. fixed with and including 2Nos. suitable powder coated brackets, holders with funnel at ends complete all as specified and as directed |
| 66 | S & F 15 mm CP cast copper alloy bib taps fancy type screwed down, screwed for iron pipe or for brass ferrule including taking down old bib taps complete all as specified and as directed. |
| 67 | S & F 15 mm pillar taps, cast copper alloy fancy type , chromium plated screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’with long screwed shanksand fly nuts, screwed for iron pipe including taking down old pillar taps complete all as specified and as directed. |
| 68 | S & F in repairs CP fancy type angle cock, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 69 | S&F in repair chromium plated overhead shower rose 125mm dia with swivel joints with and including overhead shower arm 230mm with wall flange , complete all as specified and directed by GE. |
| 70 | S & F in repair 15 mm Supply and fix in repairs, Stop valves (concealed), fancy type with CP wall flanges, chromium plated, cast copper alloy with long shank and exposed part kit with fittings sleeve, operating lever concealed part screwed both ends for iron pipe or for unions, including making good the disturbed portion matching with adjacent surfaces,complete all as specified and as directed |
| 71 | S&F in repair, Chromium plated Wall mixer with bend pipe for overhead shower with built-in non return valve with CP wall flanges,complete all as specified and directed by GE |
| 72 | S&F in repair Centre hole wash basin mixer for wash hand basinmake Jaquar Product code No CON-CHR-167KNB and equivalent as approvedcomplete all as specified and directed |
| 73 | S&F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 mtr tube & hook (braded Tube) and ABS valve including making connection and fixed in position complete all as specified and directed. |
| 74 | S&F in repair Single towel rail brass chromium plated 600mm long fixed with chromium plated screw and PVC cleat etc complete all as specified and directed. |
| 75 | S & F in repair PVC connecting pipe 450mm long 15 mm dia both end having brass coupling nut and PVC washer complete all as specified and directed. |
| 76 | S&F Vitreous china white wash down water closet pan (pedestal pattern) with PP soft closing seat cover, hinges, fixing accessories set(excluding flushing cistern and flush pipe), including UPVC (SWR) ‘P’ or ‘S’ trap and connection to drain (or outgoing pipe) and to flush pipe, antisyphonic pipe including dismantling existing water closet etc complete all as specified and directed by GE” |
| 77 | S&F Vitreous china White Squatting Orissa Pattern pan of size 580x440mm, including UPVC ‘P’ or ‘S’ trap, front or back inlet andintegral foot rests and makingconnection to trap and to flushing pipe, anti syphonic pipe, including dismantling existing squatting pan and making good to disturbed floor,complete all as specified and directed. |
| 78 | S& FVitreous China wash basin, white, flat back, size 550x400mm excluding waste, chain and plug and porcelain stopper but including brackets, including Waste coupling of PTMT(half or full threaded) (Minimum weight 32mm-45gms/40mm-60 gms)with 32mmbore PVC waste pipe minimum 800mm longwith inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed in repairs complete all as specified and as directed. |
| 79 | S&F in repairs, PVC valve less, syphonic action type, white colour flushing cistern, 10 litres capacity, low level, white, with inlet, ball valve, float and handle including jointing with new PVC long / short flush bend and making good to the disturbed surfaces complete all as per Model No:CIENA PREMIUM Cat Part No B1010102 of CERA Make ortechno commercial equivalent in other makes complete all as specified and as directed. |
| 80 | S & F in repairs Plain looking mirror of size 600x450 mm with bevelled edge selected quality glass mounted on 6mm thick commercial plywood and fixed with chromium plated brass screw and cup washers complete all as specified and as directed. |
| 81 | S & F stainless steel sink with draining board, made out of 1.00 mm thick sheet for kitchen with plugs, waste pipe and washer’sincluding cast iron cantilever brackets, connecting union etc over all size 915 mm x 460 mm with bowl size 410 x 330 x 160 mm including taking down old steel sink complete all as specified and directed. |
| 82 | S&F stainless steel plate rack of 0.63mm thick sheet, size 24\"\"x30\"\"x10\"\" complete all as specified and as directed including taking down of old unserviceable kitchen plate rack, complete all as specified and directed. Make: silvershine Model SSKPR -311 or equivalent as approved by GE. |
| 83 | S&F in repair PVC waste pipe 32/40mm bore not less than 800mm long complete all as specified and direceted |
| 84 | Dismantling of water tanks of 1000 litres capacity from roof top and supply and fixing Rotational moulded polyethylene water storage tanks (triple layered) of 1000 Litres capacity with ISI mark embossed on it, (cylindrical, vertical with closed top) hoisted and fixed in position complete all as specified and as directed. |
| 85 | Dismantling of water tanks of 500 litres capacity from roof top and supply and fixing Rotational moulded polyethylene water storage tanks (triple layered) of 500 Litres capacity with ISI mark embossed on it, (cylindrical, vertical with closed top) hoisted and fixed in position complete all as specified and as directed. |
| 86 | S&F in repair Ball valves high pressure PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of dia 20 mm bore complete all as specified and directed . |
| 87 | S&F in repair for 15 mm dia Gun-metal, golbe or gate valves/, with iron wheel head, screwd both end sor iron pipe and fixed, complete all as specified and directed. |
| 88 | M & Lin repair Gun metal Gate valves 20 mm dia with iron wheel head, screwed both ends for iron pipe and fixed including cutting the old pipes as in repair complete all as specified and directed |
| 89 | S&F in repairCornerglass self assembly consisting of 5.5mm thick sheet glass self 25cm wide with chromium plated bracket guard and fixed with CP screws and wood cleats with wall complete all as specified and directed. |
| 90 | S&F in repair glass self assembly consisting of 5.5mm thick sheet glass self 12cm wide with chromium plated bracket guard and rail 60cm long and fixed with CP screws and wood cleats with wall complete all as specified and directed. |
| 91 | Taking down eaves gutters, soil / waste / vent pipes / rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., Supply and fix, UPVC (SWR) pipes 110 mm dia, type B (conforming to IS 13592) single socketedin any length with solvent cement joints laid under floor or on walls fixed as soil / waste / vent pipes with Stack clamps made out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall complete all as specified and as directed.Note :- Provision of necessary scaffolding and security provision for replacing defective pipes shall deemed to be included in quoted rates, and nothing extra will be admissible in this regards. |
| 92 | Taking down eaves gutters, soil / waste / vent pipes / rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., Supply and fix, UPVC (SWR) pipes 75 mm dia, type B (conforming to IS 13592) single socketedin any length with solvent cement joints laid under floor or on walls fixed as soil / waste / vent pipes with Stack clamps made out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall complete all as specified and as directed.Note :- Provision of necessary scaffolding and security provision for replacing defective pipes shall deemed to be included in quoted rates, and nothing extra will be admissible in this regards. |
| 93 | S & F PVC (SWR) bends any radius 75 mm dia of bore with access door, including taking down old bends complete all as specified and directed. |
| 94 | S & F PVC (SWR) branch piece single (single T)equal of bore 75 mm dia with access doorin repairs complete all as specified and directed. |
| 95 | S & F PVC (SWR) branch piece single (single T) equal or unequal of bore 110 mm dia, with access door in repairs all as specified and as directed |
| 96 | S&F UPVC (SWR) bends any radius, 110mm bore with / without access door, complete all asspecified and directed. |
| 97 | S&F in repair PVC floor trap/Nahani Trap with plain/single hole CP grating including jointing to waste pipe in cement joint, of outlet 75 mm.dia, complete all as specified and directed. |
| 98 | M & L for welding in repairs to steel windows / doors exceeding 2.5 cm but not exceeding 5.00 cm in length and thickness of metal to be welded not exceeding 6mm complete all as specified and as directed. |
| 99 | Demolitionof cement concrete in ground floor and paving not exceeding 15cm below or above ground level removing debris outside MD landcomplete all as specified and directed. |
| 100 | Demolition of cement concrete of any description and any position not otherwise specifically provided for. and disposing off debris to outside the MOD land complete all as specified and directed. |
| 101 | Dismantling offloor, hearth or wall tiling including cement mortar bedding (including backing), removing serviceable tiles and disposing off debris to outside the MOD land all as specified and as directed. |
| 102 | Supply onlyliquid water proofing compound complete all as specified and directed. |
| 103 | M&L for Non-skid joint free coloured ceramic tiles 7 to 8 mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18sqm, as in floor set and jointed in neat cement slurry and pointed in white cement mixed with colouring pigment to match colour of tiles over and including 15mm thick screed bed of CM 1:6 complete all as specified and as directed. |
| 104 | S & F glazed ceramic coloured printed tiles of size 450 x 300X 7mm as in dado set andjointedin neat cement slurry & pointedin white cement mixed with pigment to match with color of tiles over and including10 mm thick rendering in cement motor 1:3all as specified and as directed. |
| 105 | M&L, for Vitrified tiles flooring with Light shade 10 mm thick (Square / rectangular), tiles, area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 15 mm thick screed bed in CM (1:6) complete all as specified and as directed. |
| 106 | M&L, for Vitrified tile, skirting/dado, light shade with 10 mm thick tiles of area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, on vertical rates as in skirting, dado, etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including backing coat of 10 mm thick CM 1:3 complete all as specified and as directed. |
| 107 | M&L, for heavy duty tiles (coloured),good grip series ,Size 300mmX300mmX10 to 12MM, thick pattern as Approved by Engr -in Chargeset and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 20 mm thick screed bed in CM (1:4) complete all as specified and as directed. |
| 108 | Demolition of Stone slabs & tiles of any description or thickness in floors, aprons etc. Laid, bedded & pointed in any mortar and removing debris outside MD land complete all as specified and directed. |
| 109 | M&L for 18-20mm thick Italic Marble is a high quality natural stoneslab (pre polished mirror) with fully rounded edges on front / exposed faces laid in steps, jambs, cills, pillars,on vertical faces ,top faces in neat cement slurry over 10mm thick screed bed in cement mortar 1:3 complete all as specified and directed by Engineer -in -Charge. |
| 110 | M&L for 20mm thick Granite work (of any type) (table rubbed and premirror polished) in single piece in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in cement white (1:2) using marble dust with admixture of pigment to match the shade of granite, including making hole for gas pipe including half rounding the edges of granite, laid over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 111 | M&L for Machine cut Kota stone slab flooring not less than 18 to 20 mm thick (size of stone shall not less than 55cm x 55cm), 75mm wide white marble border around, laid over & including 15mm thick screed base in CM 1:6 jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, grinding and polishing to yield mirrior finish with machine, complete all as specified anddirected. |
| 112 | M&L Machine cut Kota stone slab not less than 18 to 20mm thick as in riser of steps, skirting, dado and pillar laid over & including 15mm thick screed base in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, grinding and polishing to yield mirror finish with machine, complete all as specified anddirected. |
| 113 | S& FGI spout40 mm dia medium grade to be embeded in sunken floor complete all as specified and directed. |
| 114 | M&L for 60mm thick machine pressed rubber mouldedprecast concreteM-35 interlocking colouredpaver block any shape and size conforming to IS-15658-2006 withgrey cement and pigmentcomplete all as specified and directed. |
| 115 | M&L for Sand filling under floorsincluding watering and consolidation complete all as specified and directed. |
| 116 | M&L for Chequered cement concrete commercial Tiles 30cm x 30cm x 20 to 22mm thick of with grey cement andpigmentsetjointed and pointed in neat cement slurry in floors and cut and polished laid and over 15mm Screed in CM 1:4 all as specified and as directed. |
| 117 | M&L 75mm thick PCC type D-2, (1:4:8) using 40mm graded mechanically crushed stone aggregate as in sub base of paving/Inter Locking , Hard standing Etccomplete all as specified and directed. . |
| 118 | M&L for 40 mmthickness PCC 1:2:4 type B0 using 12.5 mm graded mechanically crushed stone aggregates as in floor finished even and smooth without using extra cementcomplete all as specified and directed. |
| 119 | M&L 25 mm thick PCC 1 : 2 : 4 type B0 (using 12.50 mm graded mechanically crushed stone aggregate) as floor roughto receive tile screed/bedding layercomplete all as specified and directed |
| 120 | M&L for roof treatment as follows:-Cleaning of dust Removal fo all loose existing bituminious material manually and with heat torch gun to get smooth plain finished surface including removing of vegetation/plantation with no loose material on surface. Repair all joints and cracks with Highly elastic Bituminous cold applied putty of Tarplasic having penetration after setting upto 8mm. Levelling of surface to give proper slope will be done as per site requirements with Shalipatch or equivalent make of approved by GE cold applied, Bituminous Mortar & Cold Emulsion cum waterproofing Liquid ofShalikote-T-10 or equivalent make of approved by GE, Created SSD condition on surface with water. Prime the surface with Tarfelt LM or equivalent make of approved by GE mixed with portable water in the ration of 1 :1 and apply @400gm per Sqm (As per Surface Conditions). . Apply first coat of Tarfelt LM or equivalent make of approved by GE having elongation 200% conforming to ASTM-C-412 & having crack bridging of 8mm confirming to ASTM-C-836 with tensile strength after 7 days 0.50 mm conforming to ASTM-C-412 with no diluation of water on primed surface while the surface is still tacky with consumption of 700gm per Sqm.. Lay Geotex of 45 GSM/ Fibre mesh simultaneously and paste it properly with overlap of 50mm. . Allow the first coat to dry for 10 to 12 Hrs..Apply 2nd coat on cured first coat with consumption @ 700gm per Sqm in opposite direction of first coat by Brush or Roller.. Allow it to dry for 10-12 hrs after apply 3rd coat with consumption @ 700gm per Sqm.Ensure final curing time of 36 hrs before allowing/ carrying out any further work. Conduct ponding test after min 7 day applying two coats of U V Resistand Elastomeric Exterior Axcrylic Weather resistant water proof coatingof Shalicryl-215 or equivalent make of approved by GE having elongation of 300% after curing of 14 days confirming to ASTM D- 6083-- for U V Protection of Bituminous Elastomeric Acrylic Emulsified Liquid Membranc of Tarfelt LM or equivalent make of approved by GE to give long life and prevent its deterioration from sunlight.Note:- Application of water proofing treatment will be done by Authorised Applicator only. |
| 121 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, complete all as specified and directed. |
| 122 | M & L for Rendering /screed bed 15 mm thick in CM 1 : 3 onconcrete surface even and smooth on roof surface, Wall surfaceincl water proof liquidfinished when concrete is green complete all as specified and directed. NOTE:- Water proofing compound shall be measured and paid separately under respective item of this Schedule. |
| 123 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 124 | S&F Pre painted galvalume aluminium zinc coating GI basedPlain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall,gulley gutter and ridgesfixed with self tapping screws complete all as specified and directed. |
| 125 | Dismantling wrought iron of mild steel work of any description not otherwise provided forcomplete all as specified and as directed by the Engineer-in-Charge. |
| 126 | S & F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed. |
| 127 | M&L for granular textured homogenous wall finishing system consisting of twocomponet system of dry granules (25 Kgs Pack ) Madeof 92% silica particlescoated with fade resistant pigments ,100% arcylic polymer bondringagent(5KG pack)with the applied thickness of thecoating being between 0.8mm to 1.2 mm to be applied on curved ,smoothlevel plastered surface , as per direction /supervision of Engr-in charge , all complete , abovetextured coating should confirm to surface spread of flame class of BS 476 Part 7 :1971 and pull of strength of the coatingto meet JISE6909 all as specified and as manufacture specification /instruction .Make (bakelite hylam Ltd or equivalent approved by GE. |
| 128 | Taking down old water tank cover and Supply and fixing Polyethylene water storage tank covers circular or any other typewith hinges suitable for 500Ltrs/1000 ltrscapacity tanksall as specified and as directed. |
| 129 | Dismantling of brick tiles or concrete tiles single layers on roof and rubbish off the premises to a distance not exceeding500 mtr including stacking of servicable brick tiles complete all as specified and as directed. |
| 130 | Demolition of mud phuska on roofs, any thickness including mud plastering,whether full thickness removed or only a part thereof and rubbish off the premises to a distance not exceeding500 mtr complete all as specified and as directed. |
| 131 | Disconnecting existing PVC water tank of capacity not exceeding 500 ltrfixed on roof by setting aside (or lowering, if required) for cleaning and removing all scale and dirt from tanks and from mouths of circulating pipes etc and hoisting/refixing/reconnecting in same/new position including writing date of cleaning on each tank with white paint, height/size of letters/figures not less than 10cm in height, and refixing existing serviceable ball valves complete all as specified and directed.” |
| 132 | M&L for Roughening surface of old concrete floor by picking sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry @ 3.0 Kg/Sqm complete all as specified and as directed |
| 133 | M&L for PCC 1:2:4 type B-0 using 12.5mm graded mechanically crushed stone aggregatesas in padding on roof to maintain the required slope & finished the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 134 | M&L Hydraulically pressed Cement Concretetiles plain size 250x250x19 mm/300x300x19 mm laid over and including 15mm thick screed in CM 1:4 with WPC & pointed in CM1:3 mixed with crude oil ( WPC as per manufacturer\"s instruction shall be deemed to be included in unit rate quoted)Note :- water profiing treatment will be carried out through approved applicator of M/s Dr. Fixit. |
| 135 | M&L for APP polymeric water proofing treatement to roof, at any height, using membrane minimum 3 mm thick and weighing not less than 3.6 kg per sqm , black finish reinforced with non-woven polyster matt weighting not less than 150 gms per sqmwith thermo fusible finish laid by force application after applying compatible bitumen primer at the rate of 0.40 Ltr per Sqm, torching over laps with a propane orbutane gas torch with a over lap of 100 mm at the side on transverse direction and 150 mm at the ends on longitudinal directionand sealing including a tack coat of hot blown bitumen 85/25 @ 1.2 Kg per sqm below APP tucking into parapet walls, cut out neatly a horizontal groove 6.5cmm deep, 7.5cm wide section with lower edge at not less than 15cm above the graded roof surface and groove shall be finished smooth with cement mortar 1:4 with WPC @3% by weight of cement where the parapet wall height is 45cm or less no groove will be required as the water proofing treatment will be carried over the top of parapet wall to its full thickness including 15mm thick screed bed in CM 1:4 with WPC @3% by weight of cement, complete all as specified and as directed . Notes:-(i) The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators duly approved by GE in writing. (ii)5% amount of the total amount of water proofing treatment shall be retained as a guarantee (on account of any defect raised/noticed during a period of ten years) and shall be released after 10 years of completion of work. However contractor may deposit the FDR of same amount in favour of GE. If contractor fails to rectify the defect pointed out during this period , the defect shall be got rectified at contractor\"s risk and cost and the payment shall be made from the amount kept reserved or by encashing the FDR deposited by the contractor as guarantee. The contractor\"s quoted rates for this item shall deemed to be inclusive of this aspect.(iii) WPC shall be deemed to be included in the quoted rate. |
| 136 | M&L for brooming down surfaces of any description and applying one coat of white wash onold decorated surfaces of Ceilingincluding preparation of old surfaces & filling cracks and holes etc complete all as specified and directed. |
| 137 | M&L for brooming down surfaces of any description and applying Twocoat of white wash onold decorated surfaces of Ceilingincluding preparation of old surfaces & filling cracks and holes etc complete all as specified and directed. |
| 138 | M&L for Preparing the surfaces of old wall surfaces and applying one coat of distemper oil emulsioncomplete all as specified and directed |
| 139 | M&L for Preparing the surfaces of old wall surfaces and applying Twocoat of distemper oil emulsioncomplete all as specified and directed |
| 140 | M&L for Complete removal of existing treatment and preparing the surfaces of walls plastered or unplastered and applying two coat of distemper oil emulsionover a coat of alkali resistent primer over putty any thickness.complete all as specified and directed Note : Quoted rate shall deemed to include for cost of wall care putty. |
| 141 | M&L for preparation of old / new masonry / concrete walls / ceiling treated / untreated surfaces and applying two coats of plastic emulsion paint (of approved tint) over a coat of 1mm thick wall care putty including all necessary staging, scaffolding, safety precautions, etc. as required to work at heights, etc. complete all as specified and as directed Note: quoted rate shall be deemed to included for cost of wall care putty |
| 142 | M&L for Preparation of old wooden surfaces and applying a coat of synthetic enamel paint over 10 cm width or girthcomplete all as specified and as directed. |
| 143 | M & L for painting of old steel surfaces of any description not otherwise described over 10 cm width or girth with onecoats of synthetic enamel paint including preparation of surfaces etc complete all as specified and as directed. |
| 144 | M&L for preparing the surfaces of walls plastered or unplastered Applying onecoats of weather-proof antifungal exterior emulsion paintover a coat of alkaline resistant primer including necessary scaffolding etc complete all as specified and directedupto triple storey building, complete all as specified and directed. Note: Item may be executed upto height of 15.00 m cost of necessary scaffolding and security provision of labour shall be deemed to be incldued in the quoted rate. |
| 145 | M&L for complete removal of existing treatment on surfaces of walls, chajjas, fascias etc and effloroscent salts and treating oil and greasy spots washing down with water andpreparing the surfaces any descriptionApplying Twocoats of weather-proof antifungal exterior emulsion paintover a coat of alkaline resistant primer including filling up all cracks with tar plastic (STP) crack filler or chicken wire mesh with plaster in CM 1:4 including necessary scaffolding etc complete all as specified and directedupto triple storey building, complete all as specified and directed. Note: Item may be executed upto height of 15.00 m cost of necessary scaffolding and security provision of labour shall be deemed to be incldued in the quoted rate. |
| 146 | S&F machine crafted box type cabinet for kitchen using 18-19 mm thick PVC board both side laminated with and including all necessary fitting and fixtures to install wire basket , shutter shall be fixed by using full overlay MS clips on hinges high quality nickle plated satin finish size- 101 mm -150 mm ,02Nos per leaf ,including all fittings ,channels , 150 mm s/s handles complete all specified and directed .NOTE:- (i)Wire basket shall be measured separetely.(ii)Front area of box shall be considered for payment purpose.(iii) Depth of box shall be equal to the width of cooking platform.(iv) all fittings incl quoted rate |
| 147 | S&F wire basket made of top quality 304 grade stainless steel,nickle chromium plated ( Ni 4%) of Approved design and pattern complete all as specified and directed. |
| 148 | M&L for cement concrete 1:2:4 type B0 ( using 12.5 mm graded mechanically crushed stone aggregate ) as in coping,kerbfor water trough and the like including weathering , slightly rounded or chamfered agle and throating etc incl necessary form work etc complete all as specified and directed |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail