| 1 | Excavating in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 mtr in depth and getting out soft/loose soil complete all as specified. |
| 2 | Returning filling in soft/loose soil, including, spreading, levelling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed. |
| 3 | Removing of surplus soil to a distance not exceeding 50 metre and deposited where directed at a level not exceeding 1.50 metre above the starting point all as specified. |
| 4 | Supply and filling for dry sand in cable protection trenches before and after the cables are laid, for sand cushioning to cables complete all as specified and directed. NOTE : thickness after punning of sand shall be (minimum as specified in SSR) measured and paid in this item. |
| 5 | Supplying and laying un-reinforced precast concrete cable cover, class LV, type 2 with peak, size 300 mm x 180 mm x 40 mm complete all as specified. |
| 6 | Material and labour for PCC, type C2, (1:3:6, using 40mm graded stone aggregates) as in coping of pole/ plinth blocks of HT poles etc. including fair finishing the exposed surfaces even and smooth without using extra cement including necessary form work complete all as specified and as directed by Engr-in-Charge. |
| 7 | Material and labour for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed. |
| 8 | Supply and laying, connecting, testing, commissioning LT UG cable XLPE Insulated,armoured,electric powercables (heavy duty) 1100 Volts grade conforming to IS 7098 withaluminium conductor multi-strand of cross-sectional area 10 Sqmm 2.00 Core laid in trenches / ducts/ inside protection pipe including cable glands, lugs and suitable size of MS saddle clips etc. including taking out old UG cable all as directed by Engr-In-Charge.Note:-(a) Excavation, sand cushioning, bricks shall be measured and paid separately |
| 9 | Supply and laying, connecting, testing, commissioning LT UG cable XLPE Insulated,armoured,electric powercables (heavy duty) 1100 Volts grade conforming to IS 7098 withaluminium conductor multi-strand of cross-sectional area 16 Sqmm 4.00 Core laid in trenches / ducts/ inside protection pipe including cable glands, lugs and suitable size of MS saddle clips etc. including taking out old UG cable all as directed by Engr-In-Charge.Note:-(a) Excavation, sand cushioning, bricks shall be measured and paid separately |
| 10 | Supply and laying, connecting, testing, commissioning LT UG cable XLPE Insulated,armoured,electric powercables (heavy duty) 1100 Volts grade conforming to IS 7098 withaluminium conductor multi-strand of cross-sectional area 25 Sqmm 3.50 Core laid in trenches / ducts/ inside protection pipe including cable glands, lugs and suitable size of MS saddle clips etc. including taking out old UG cable all as directed by Engr-In-Charge.Note:-(a) Excavation, sand cushioning, bricks shall be measured and paid separately |
| 11 | Supply and laying, connecting, testing, commissioning LT UG cable XLPE Insulated,armoured,electric powercables (heavy duty) 1100 Volts grade conforming to IS 7098 withaluminium conductor multi-strand of cross-sectional area 35 Sqmm 3.50 Core laid in trenches / ducts/ inside protection pipe including cable glands, lugs and suitable size of MS saddle clips etc. including taking out old UG cable all as directed by Engr-In-Charge.Note:-(a) Excavation, sand cushioning, bricks shall be measured and paid separately |
| 12 | Supply and laying, connecting, testing, commissioning LT UG cable XLPE Insulated,armoured,electric powercables (heavy duty) 1100 Volts grade conforming to IS 7098 withaluminium conductor multi-strand of cross-sectional area 50 Sqmm 3.50 Core laid in trenches / ducts/ inside protection pipe including cable glands, lugs and suitable size of MS saddle clips etc. including taking out old UG cable all as directed by Engr-In-Charge.Note:-(a) Excavation, sand cushioning, bricks shall be measured and paid separately |
| 13 | Supply and laying, connecting, testing, commissioning LT UG cable XLPE Insulated,armoured,electric powercables (heavy duty) 1100 Volts grade conforming to IS 7098 withaluminium conductor multi-strand of cross-sectional area 70 Sqmm 3.50 Core laid in trenches / ducts/ inside protection pipe including cable glands, lugs and suitable size of MS saddle clips etc. including taking out old UG cable all as directed by Engr-In-Charge.Note:-(a) Excavation, sand cushioning, bricks shall be measured and paid separately |
| 14 | Supply, lay and fix 40 mm bore galvanized iron tubing (light grade) including all fittings and laid in trenches, walls and ceilings or laid in floors complete all as specified and directed.Note: Excavation shall be measured and paid in separate item |
| 15 | Supply, lay and fix 50 mm bore galvanized iron tubing (light grade) including all fittings and laid in trenches, walls and ceilings or laid in floors complete all as specified and directed.Note: Excavation shall be measured and paid in separate item |
| 16 | Material and labour for aluminium lugs upto 70 Sqmm complete all as per manufacturer instruction. |
| 17 | Material and labour for installation in replacement of thermoplastic junction with IP 66 protection (halogen free and weather proof) for outdoor installations of size 200 mm x 160 mm x 98 mm with terminals on DN rail for aluminium cables upto 25 Sqmm 4 core with one single pole MCB \"C\" curve type of current rating 6 Amps and rupturing capacity 10 KA complete with thermoplastic cable glands and fixed on light grade GI pipe of suitable size as per direction of Engineer-In-Charge and using pole clamps made out appropriate material including testing at site by OEM engineer.Note: GI pipe inclusive all fixture and fittings, cable, SP as above shall be measured and paid including this item. |
| 18 | Material and labour for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified. |
| 19 | Supply and fixingin replacement Astronomical Street Light time Switch alongwith suitable Power Contactor, MCB and Support Terminals should be enclosed in pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade special moulding compound (Sintex make SMC Junction box) conforming to IP54.The Contactor, MCB and Circuit Wiring should suitable enough to take load of 12 kWload equally distributed over 3-phase .Contactor Rating: 65.Amps (4-pole).MCB (4-pole) Rating: 63.Amps (3 nos.) complete all as per manufacturer instruction. |
| 20 | Supply and fix recess mounted LED wall washers, tilted 70° outwards and swivels 350° to offer best illumination on the wall and retail displays complete with driver, complete all as specifed and directed.Note:- (a) LM-80 certificate from NABL accredited Lab shall be submitted for LED light fittings.(b) Warranty certificate shall be submitted for LED light fitting as per standered format for minium 50000 Hrs.(c) LED light fitting and drivers shall be of same make. |
| 21 | Supply and fix LED Post top lantern of 50 Watts, 240V, 50Hz IP 65 made of black ABS plastic spigot, spun aluminium funnel shape with clear acrylicand accessories such as integrated drivers pre-wired etc suitable with gate lightpipe.Note:- (a) LM-80 certificate from NABL accredited Lab shall be submitted for LED light fittings to the Engineer-In-Charge.(b) Warranty certificate shall be submitted for LED light fitting as per standard format for minimum 50000 Hrs to the Engineer-In-Charge.(c) LED light fitting and drivers shall be of same make. |
| 22 | Supply and fix environmental friendly, compact, light weight, energy saving, IP66 LED spike light of 5 watt rating using COB LED as light source of Warm White Colour. Multi purpose application like column lighting, tree up-lighting, statue accentuation etc. can be addressed with ease.Note:- (a) LM-80 certificate from NABL accredited Lab shall be submitted for LED light fittings to the Engineer-In-Charge.(b) Warranty certificate shall be submitted for LED light fitting as per standard format for minimum 50000 Hrs to the Engineer-In-Charge.(c) LED light fitting and drivers shall be of same make. |
| 23 | Supply and fix high light intensity empowered color changing & monochromatic LED of 30 watt rating under water fountain light with polarized light design & intelligent logarithmic control technology.Note:- (a) LM-80 certificate from NABL accredited Lab shall be submitted for LED light fittings to the Engineer-In-Charge.(b) Warranty certificate shall be submitted for LED light fitting as per standard format for minimum 50000 Hrs to the Engineer-In-Charge.(c) LED light fitting and drivers shall be of same make. |
| 24 | Supply and fixing PVC insulated and PVC round sheathed, copper conductor (flexible) industrial cable 2.5 sqmm, three core cablein and including through GI tube of light grade of 15mm bore dia for connection of street light on pole / wall from over head conductor / junction box / DB including termination clip etc all as specified. |
| 25 | Supply and fixing sub-main wiring with PVC insulated & unsheathed two run of 6.00 Sqmm single core multistrand copper conductor cable (FRLSH), 1100 Volt grade alongwith single run of 6.00 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH) 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through minimum 25 mm PVC conduit complete all as specified and directed.Note:- (a)PVC conduit in concealed including accessories shall be measured and paid including the item.(b) 2 Run of line conductor and 1 Run of earth continuity conductor shall be measured as one unit length.(c) Cable requireds for connection to MCBs/DBs shall be deemed to be included in the unit rate.(d) Rate shall be included for cutting, pinning in, making good to facings where required for pointing in cement mortar 1:3 and cutting chases for concealed conduit wiring and making good, and cutting not exceeding 10 cm girth. |
| 26 | Material and labour for brick protection for UG XLPE cable with burnt clay old size sub class \"B\" bricks laid dry and flat abutting each other with gaps between adjacent brick not more than 10mm and width equal to length of brick in trenches across the cable complete all as directed by Engineer-In-Charge.Make: Best quality locally available which is duly approved by GE. |