| 1 | Taking down carefully of transformer capacity 50 KVA to 100 KVA from four pole and two pole structure, platform by disconnecting all the electrical connection and transporting the same to authorised workshop including draining out of the transformer oil in clean barrels, opening the top cover, taking out of the defective/burnt out HT/LT coils out of the tank for repair, insulation testing of the transformer winding ,refilling the transformer oil after checking proper dielectric strength, refitting the top cover andother accessories including painting of the transformer with approved colour with synthetic enamel paint, all as specified and directed and transporting the transformer back on original place for installation and securing properly on four/two pole/platform and making all HT/LT connection to the complete satisfaction of Engr-in-charge. |
| 2 | Ditto all as per Srl item No 01 here-in-above but exceeding transformer capacity 150 KVA and upto 200 KVA Note for Srl Item No 1 and 2 :-(a) The rates are inclusive of transportation of transformer from site of installation to authorised workshop and back including T&P required for loading/ unloading and all the HT/LT winding shall be measured and paid separetly. (b) Standby transformer shallbe arranged by contractor at their own cost to avoid failure of supply on siteand the capacity of transformer should bematchedwith repaired transformer.Penalty charges @1000/day shall be deducted on failure of arrangement of standby transformer. (c) Contractor has to submit the list of authorized workshops for full satisfaction of Engr-in charge and final binding shall remain with the Engr -in-charge. |
| 3 | Replacement of burnt defective LT copper coil of transformer capacity 50 KVA to 100 KVA with new one made out of suitable size/guage of copper super enameled wire of high quality matching with the existing impedence and insulation all as specified and directed by Engr-in-Charge |
| 4 | Ditto all as per Srl item No 3 above but of transformer capacity exceeding 150 KVA and upto 200 KVA.Note for srl item No 3 & 4 :-The cost of coil shall be inclusive of cost of varnish insulatingpaper and other insulating materials and no extra payment will be made for the same. |
| 5 | Replacement of burnt defective HT copper coil of transformer capacity 50 KVA to 100 KVA with new one made out of suitable size/guage of copper super enameled wire of high quality matching with the existing impedence and insulation all as specified and directed by Engr-in-Charge |
| 6 | Ditto all as per Srl item No 5 above but of transformer capacity exceeding 150 KVA and upto 200 KVA.Note for srl item No 5 & 6 :-The cost of coil shall be inclusive of cost of varnish insulatingpaper and other insulating materials and no extra payment will be made for the same. |
| 7 | Filtration, heating and dehydration of transformer oil on site by using filteration machineand EHV grade having dielectric strength not less than 55 KV with 2mm gap inluding removal of all moisture,dirt/girth all as specified and directed by Engr-in-charge.Note:-Filtration, heating and dehydration of transformer oil shall be carried out on site and rate quoted by contractor shall deemed to include for arrangement of filtration machine and its transportation to various locations of installation of transformer and topping of oil. |
| 8 | HT bushing assembly with brass nut, stud, washers and insulators suitable for outdoor type transformer capacity of 50 KVA to 200 KVA, complete all as specified and directed. |
| 9 | LT bushing assembly with brass nut, stud, washers and insulators suitable for outdoor type transformer capacity of 50 KVA to 200 KVA, complete all as specified and directed. |
| 10 | Construction in replacement of transformer platform size 3mx2mx1m from ground and 0.5 mtr below ground level with brick construction in wall and steps, XPM fencing upto 1.5 mtr height with angle iron post 50 x50x6mmincluding gate with locking arrangement min weight 60 Kgs, 100mm PCC 1:5:10 type E-2 in foundation, 0.23 mtr thick brick work in CM 1:4, 10 mm thick rendering in CM 1:4 to walls, 50 mm thick PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) in flooring over 100 mm thick sub base in PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) laid over rammed earth, 40 mm thickPCC on steps, painting to fencing with two coats of synthetic enemled paint over a coat of red oxide primer, complete all as specified and directed. |
| 11 | Supply and filling Transformer oil of dielectric strength not less than 40KV with 4mm gap of discharge 2 sec for topping up of transformer complete all as specified and directed. |
| 12 | Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres belowground level, connected to and including galvanised strip 25x4mm by means of bolts, nuts, check nuts and washers of galvanised iron and light grade protection pipeof 40 mm diafrom earth electrode up to test point or up to 7.5mtr whichever is less by means of GIbolts, nuts, check nuts and washersall as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh, including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45cm x 45cm x 45 cm,RCC cover 1:2:4 type B1 of size 45x45x6 cm, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required valueincluding removing old item completeall as specified and directed.Note:-The required resistance of Earthing shall be less than 3 ohm, If not found to the required resisstance, the contractor has to re earthingfor required resistance andthe cost for the same included in the quoted rate and no extra shall be paid on failure of getting required resistance. |
| 13 | Supply and fixing aluminium strip of size 25x 3.15 mm to be fixed on wallor to belaid in ground complete all as specified and directed. |
| 14 | Disconnecting input/output supply from voltage stabilizer of capacity up to 100 KVA any type oil/air cooled and dismantling the same for repair checking/testing all component complete repairing for efficient functioning checking/tightening of all connections resetting/recalibration of allPCB’s ,servo motors, voltmeter, cleaning of tapping, joints of dimmer stat including replacement of minor parts like screws bolts gear of servo motor carbon brushes button and other minor parts etc all as directed by Engr-in-charge. |
| 15 | Ditto all as per Srl item No 14 above but of voltage stablizer capacity exceeding 100 KVA and upto 200 KVA. Note for srl item no 14 and 15 : - Cost of PCB control cards, servo motors, voltmeter, relays.Ampere meter, contactor, selector switch, rewinding varic/dimmer of stabilizer will be measured and paid separately under relevant item of work as supply only. |
| 16 | Supply only servo motor 3 Kg torqueof make of existing motor |
| 17 | Supply only servo motor 10 Kg torque of make of existing motor |
| 18 | Supply only servo motor 20 Kg torque of make of existing motor |
| 19 | Supply only servo motor 40 Kg torque of make of existing motor |
| 20 | Supply only dimmerstate for 30 KVA unbalanced servo stabilizer |
| 21 | Supply only dimmerstate for 25 KVA unbalanced servo stabilizer |
| 22 | Supply only dimmerstate for 15 KVA unbalanced servo stabilizer |
| 23 | Supply onlyRC network for 10Kg servo motor |
| 24 | Supply only RC network for 3 Kg servo motor |
| 25 | Supply only RC network for 20Kg servo motor |
| 26 | Supply only RC network for 40 Kg servo motor |
| 27 | Supply only PCBcontrol Cards for Servo voltage stabilizer upto 100 KVA |
| 28 | Supply only PCBcontrol Cards for Servo voltage stabilizer above 100 KVA to 200 KVA |
| 29 | Supply onlyTrigger transformer for up to 100 KVAfor balanced type voltage stablizer |
| 30 | Supply onlyTrigger transformer rom for above100 KVA to 200 KVAfor balanced type voltage stablizer |
| 31 | Supply only rotary switch for RYB phases |
| 32 | Supply only Drive assembly for voltage stabilzer upto 100 KVA per phase |
| 33 | Supply only Drive assembly for voltage stabilzer above 100 KVA to 200 KVA per phase |
| 34 | Supply only PCB holder for balanced type voltage stabilizer upto 100 KVA |
| 35 | Supply only PCB holder for balanced type voltage stabilizer above 100 KVA to 200 KVA |
| 36 | Note:- Deduction for Schedule of credit (Sch \"A\" Part-II) to be made of ₹ 278566.00 from the total quoted amount of BOQ while accepting the bid. Details of schedule of credit is given in tender documents. |