Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fittings such as switches, bell push, holders, ceiling roses, pendants, regulators, sockets etc but excluding DBs, light fittings etc andmaking good disturbed surfaces of walls, floors etc. and matching with existing surface all as specified and as directed. |
| 2 | M & L for point wiringcomplete on surface of wall (open) type with two runs of 1.5 sqmm for phase and neutral, single core, multistranded copper conductor cable of 1100 Volts grade,conforming to IS-694 1990,PVC insulated andunsheathed , FRLS cabledrawn through and including PVC casing and caping (ISI marked) and its accessories such as Tee, elbow, jointer, elbow corner etc. fixed on surface of walls, coloumns/ beams alongwith 1.5 Sqmmcopper conductor cable (multistranded)PVC insulated and unsheathed FRLS cableas earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other end including PVC folding boards/bakelite sheetsfor mounting switches, sockets, fan Regulators, accessories etc as specified and directed for one light point or one fan point controlled by one, one way switch. NOTE: 1. Proper colour coding shall be adopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black) 2. wiring shall be done as per complaints receivedfrom user only on reqired basis it is not necessary to do whole wiring of any whole bldg.3. All points shall be earthed up to fixtures i.e holders,tube lights,all lights,ceiling lights,bulkhead lights,bldg security lights etc. |
| 3 | All as per serial item No. 2here in before but one 6 Amp 3 pin socket outlet point on same board with other switches including earth wire as specified. |
| 4 | All as per serial item No. 2 here in before but on independent board. |
| 5 | All as per serial item No. 2here in before butfor one bell/buzzer point controlled by one push button on the same board with other switches or independent. |
| 6 | All as per serial item No. 2here in before but for one light point controlled by 2 way switches. |
| 7 | All as per serial item No. 2herein before but with 2.5 Sqmm, PVC copper stranded cable FRLS type for phase,Neutral and earth forone 15 Amp, 6 pin socket on independent board. |
| 8 | S&F switch piano, flush button, 6 Amp, single pole, one way, 230 volts, white finish, all as specified & as directed. |
| 9 | S&F socket outlet, flush type, 3 pin, 6 Amp, multipurpose, 230 volts, single pole, one way suitable for 3 pin/2pin, 5 Amp plug top white/ivory finish all as specified & as directed. |
| 10 | S&F switch socket combination, flush type, 3 pin, 6 Amp, multipurpose, 230 volts, single pole, one way, suitable for 3 pin/2pin 5 Amp plug top white/ivory finish all as specified & asdirected. |
| 11 | S&F switch socket combination, multipurpose, flush type, 2 in 1 type (3 pin ) 6/16 Amps, 230V, AC. all as specified & asdirected. |
| 12 | S&F lamp holder, angle/ batten type, PVC/Polycarbonate type with back plate, suitable for batten fittings all as specified & asdirected. |
| 13 | S&F ceiling rose, surface PVC 50mm dia, 3 terminals including PVC mounting block white/ivory finish all as specified & asdirected. |
| 14 | S&F bell push, flush type, 6 Amp, single pole, 230 volts, white finish all as specified & as directed. |
| 15 | S&F switch piano, flush button, 6 Amp, single pole, 2 way, 230 volts, white finish all as specified & as directed. |
| 16 | S&F fan regulator, step type, electronic on existing phenolic laminated sheet, 5 step, sockettype, 230 volts, suitable for ceiling fan 1200/1400mm sweep all as specified & asdirected. |
| 17 | M&L for point wiring with two runs of 1.5 sqmm for phase and neutral, single core, multistranded copper conductor cable of 1100 Volts grade, conforming to IS-694 1990,PVC insulated andunsheathed , FRLS cable laid / fixed and including concealed in PVC rigid conduit on walls/ceiling alongwith 1.5 Sqmmcopper conductor cable (multistranded)PVC insulated and unsheathed FRLS cableas earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other end including including Sunken box, PVC folding boardsfor mounting switches, sockets, fan Regulators, accessories etc as specified and directed for one light point or one fan point controlled by one, one way switch NOTE :- 1.Proper colour coding shall be adopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black) 2.wiring shall be done as per complaints receivedfrom user only on reqired basis it is not necessary to do whole wiring of any whole bldg. 3. All points shall be earthed up to fixtures i.e holdrs,tube lights,all lights,ceiling lights,bulkhead lights,bldg security lights etc.4. Unit rate include for cutting chases for conduits and sinking for boxes andmaking good to wall ,floors etc. |
| 18 | All as per serial item No. 17 here-in-before but for one 6 Amp, 3 pin socket outlet point on same board with other switches including earth wire as specified. |
| 19 | All as per serial item No. 17 here-in-before buton independent board. |
| 20 | All as per serial item No. 17 here-in-before butfor one bell/buzzer point controlled by one push button on the same board with other switches or independent. |
| 21 | All as per serial item No. 17 here-in-before butfor one light point controlled by 2 way switches. |
| 22 | All as per serial item No. 17here-in-before but with 2.5 Sqmm, PVC copper stranded cable FRLS type for phase, neutral and earth forone 16 Amp, 6 pin socket on independent board. |
| 23 | S&F modular switch one way, 6 Amp, one module, 230V all as specified and directed. |
| 24 | S&F modular bell push, 6 Amp, one module, 230V all as specified and directed. |
| 25 | S&F modular socket, 6A, 3 pin2 module, 230V all as specified and directed. |
| 26 | S&F modular switch one way, 16 Amp, one module, 230V all as specified and directed. |
| 27 | S&F modular socket, 6A/16A,3 pincombined2 module, 230V all as specified and directed. |
| 28 | S&Fmodular fan Regulator, 120 watt , 2 module complete all as specifed and as directed. |
| 29 | S&Fmodular cover plate frame, 3 module complete all as specifed and as directed. |
| 30 | S&F modular cover plate frame, 4 module complete all as specifed and as directed. |
| 31 | S&Fmodular cover plate frame, 6 module complete all as specifed and as directed. |
| 32 | S&F modular cover plate frame, 8 module complete all as specifed and as directed. |
| 33 | S&Fbell,AC, 230 volts, single phase complete all as specified and as directed. |
| 34 | S & F Inverter LED batten 20W 6500K with square profile and polycarbonate channel, lithium-Ion battery with charging time 8hours-10 hours, back up time up to 4 hours and surge protection up to 4KV.Make : HAVELLS PRIDE PLUS INVERTER BATT EN Cat No LHEXACP7FN1W020or equivalent model of makes specified. |
| 35 | S & F square profile LED lighting fixture with extruded polycorbonate,environmental friendly,energy efficient ready to use pack LED Tube light fitting 20 Watt with LED light source 6500k with uniform light output,with all accessories including its connection complete with all as specified and directed by Engineer-in-charge.Make:HAVELLS LED PRIDE ESSENTIAL Cat No LHEXAWP7UN1W020or equivalent model of makes specified. |
| 36 | S&F in repairs, 600 mm x 600 mm size,recess mounted LEDluminaire of capacity36watt, with driver, for soft glare free light, AC 230 voltcomplete with all acessories and connections, complete all as specified & asdirected.Make:HAVELLS OCTANE PLUS LED 2 X 2 PANELCat No LHEBAEP7IW1W036 or equivalent model of makes specified. |
| 37 | S&F in repairs, bakelite sheetboardof 100 mm x 100mm size,not less than 3mm thick for mounting of switch, sockets, fan regulators, etc.complete with screws and washers, etc. all as specified and as directed. |
| 38 | S&F in repairs, bakelite sheetboardof 175 mm x 100mm size,not less than 3mm thick for mounting of switch, sockets, fan regulators, etc.complete with screws and washers, etc. all as specified and as directed. |
| 39 | S&F in repairs, bakelite sheetboardof 200 mm x 150mm size,not less than 3mm thick for mounting of switch, sockets, fan regulators, etc.complete with screws and washers, etc. all as specified and as directed. |
| 40 | S&F in repairs, bakelite sheetboardof 250 mm x 200mm size,not less than 3mm thick for mounting of switch, sockets, fan regulators, etc.complete with screws and washers, etc. all as specified and as directed. |
| 41 | S&F in repairs, bakelite sheetboardof 350 mm x 300mm size,not less than 3mm thick for mounting of switch, sockets, fan regulators, etc.complete with screws and washers, etc. all as specified and as directed.Notefor item Nos 37 to 41 : Cutting of backelite sheet board for mounting switch,sockets, fan regulators etc. shall be as per site requirement. |
| 42 | S&F in repairs, PVC rectangular box of 100 mm x 100mm x 50 mm deep, for mounting of switch, sockets, fan regulators, etc.complete with screws and washers, etc. all as specified and as directed. |
| 43 | S&F in repairs, PVC rectangular box of 175 mm x 100mm x 50 mm deep, for mounting of switch, sockets, fan regulators, etc.complete with screws and washers, etc. all as specified and as directed. |
| 44 | S&F in repairs, PVC rectangular box of 200 mm x 150mm x 50 mm deep, for mounting of switch, sockets, fan regulators, etc.complete with screws and washers, etc. all as specified and as directed. |
| 45 | S&F in repairs, PVC rectangular box of 250 mm x 200mm x 50 mm deep, for mounting of switch, sockets, fan regulators, etc.complete with screws and washers, etc. all as specified and as directed. |
| 46 | S&F in repairs, PVC rectangular box of 350 mm x 300mm x 50 mm deep, for mounting of switch, sockets, fan regulators, etc.complete with screws and washers, etc. all as specified and as directed. |
| 47 | S&F repairs socket outlet, flush type, 3 pin, 6 Amp, multipurpose, 230 volts, single pole, one way suitable for 3 pin/2pin, 5 Amp plug top white/ivory finish all as specified & as directed. |
| 48 | S&F in repairs, switch/socketcombination with box type outlet, 3 pin,6 Amps,flush type (Multi purpose), piano type,AC 230 Volts. all as specified and as directed. |
| 49 | S&F in repairs, switch/socketcombination with box type outlet,2 in 1, 3 pin,6 Amps and 16 Amp,flush type (Multi purpose), piano type,AC 230 Volts all as specified and as directed. |
| 50 | S&F in repairs, switch piano, flush button, 6 Amp, single pole, one way, 230 volts, white finish all as specified & as directed. |
| 51 | S&F in repairs, and connecting up fan regulator, electronic on existing phenolic laminated sheet, 5 step sockettype, 230 volts, suitable for ceiling fan 1200/1400mm sweep all as specified & as directed. |
| 52 | M & L for sub main wiring with 4 runs of 10 sqmm, single core, PVC insulated & unsheathed FRLS cable conforming to IS-694, 1100 volts with copper conductor, multi stranded drawn in and including suitable size heavy grade casing caping (ISI marked) with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 10 sqmm single core PVC insulated & unsheathed FRLS copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduit complete all as specified and as directed.NOTE: 1. Proper colour coding shalladopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black)2. Five runs of 10 sq.mm cable and one run of PVC casing & caping shall be measured as one unit. |
| 53 | M & L for sub main wiring with 2 runs of 6 sqmm, single core, PVC insulated & unsheathed FRLS cable conforming to IS-694, 1100 volts with copper conductor, multi stranded drawn in and including suitable size heavy grade casing caping (ISI marked) with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6 sqmm single core PVC insulated & unsheathed FRLS copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduit complete all as specified and as directed.NOTE: 1. Proper colour coding shalladopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black) 2. Three runs of 6 sq.mm cable and one run of PVC casing & caping shall be measured as one unit. |
| 54 | M & L for sub main wiring with 2 runs of 4 sqmm, single core, PVC insulated & unsheathed FRLS cable conforming to IS-694, 1100 volts with copper conductor, multi stranded drawn in and including suitable size heavy grade casing caping (ISI marked) with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4 sqmm single core PVC insulated & unsheathed FRLS copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduit complete all as specified and as directed.NOTE: 1. Proper colour coding shalladopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black)2. Three runs of 4 sq.mm cable and one run of PVC casing & caping shall be measured as one unit. |
| 55 | S&F metal base plastic enclosurewith plug socket, single pole and neutral with two pin and earth plug with one MCB of 20 Amps (SP)complete all as specified and as directed. Make : Havells DBOX Plug and socket or equivalent approved make |
| 56 | S&F in repairs, MCB SP, AC 240 V, 6 to 32 Amps, 10 KA capacity ,\"c\" series, making connection with suitable size of copper lugs etccomplete all as specified and as directed. |
| 57 | S&F in repairs, MCB SPN, AC 240 V, 6 to 32 Amps, 10 KA capacity ,\"c\" series, making connection with suitable size of copper lugs etccomplete all as specified and as directed. |
| 58 | S&F in repairs double door shutter type for distribution board (when MCBs are to be used), single pole and neutral, 240 volts, 8 way,protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, suitable for flush mounting and surface mounting, with 100 Amps rated copperbusbar, with Neutral bar, Earthbar and cable alley for cable managment, fully shrouded, Neutral bars, prefittes masking sheet complete all as specified and as directed. |
| 59 | S&F in repairs, double door shutter type for distribution board (when MCBs are to be used), single pole and neutral, 240 volts, 4 way,protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, suitable for flush mounting and surface mounting, with 100 Amps rated copperbusbar, with Neutral bar, Earthbar and cable alley for cable managment, fully shrouded, Neutral bars, prefittes masking sheet complete all as specified and as directed. |
| 60 | S&F in repairs, double door shutter type for distribution board (when MCBs are to be used), Tripple pole and neutral, 415 volts, 4 way,protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, suitable for flush mounting and surface mounting, with 100 Amps rated copperbusbar, with Neutral bar, Earthbar and cable alley for cable managment, fully shrouded, Neutral bars, prefittes masking sheet complete all as specified and as directed. |
| 61 | S&F in repairsISOLATOR TPN, AC 415 V, 63 amps, 10 KA capacity ,\"C\" series, making connection with suitabl size of copper lugs etccomplete all as specified and as directed. |
| 62 | Supply and fix security light of building with single piece New generation energy savng and environmental friendly long life LED 35W made up of pressure die cast aluminium housing with acrylic covers as diffuser with IP66 protection and impact resistance of IK07including one bracket made of Light gradeGI Pipe 25 mm dia 1.0 mtr long fixed to wallwith two clams made out of MS FI 30 mm x 5 mmfixed with anchor bolt and connection all as directed and as specified. |
| 63 | M&L in repairs/replacement earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.3 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to the GI wire 4 mm dia, by means of nut bolts, check nuts and washer of the GI . Earth wire connected upto main earth point/DBs alongwith 15mm dia GI pipe, medium grade,including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick RCC (1:2:4)cover with reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh andearth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion. |
| 64 | Supply Only electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH |
| 65 | S & F 360 degree Ceiling-Mount PIR Motion Sensor Switch with LUX Sensor inbuilt Energy Saving Sensor,LUX Adjustment, Time Adjustment,Automatic Sensor of 220V with quick sense of maximum range up to 7 meters etc all as specified and as directed. |
| 66 | M & L for complete removal of existing treatment and applying 2 mm thick of birla white wall care putty to achieve smooth surface and applying two coat of Acrylic distemper of approved shade/tint overa coat of primer complete to match the existing surface complete all as specified and as directed.Note: This item will be executed only on distrubed surface of point wiring. |
| 67 | S&F in repairs, guarden light wiring with PVC insulated, sheathed cable with stranded aluminium conductor of size2.5sqmm, two core through PVC pipe of 15 mm size including excavation eath work complete with all accessories including cable connectionfrom junction box to light fittings complete all as specified & as directed. |
| 68 | S & F in repairs new generation IP 65 LED post top lantern 15 watt, energy saving, enviorment friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape lumainarie with high power LEDs as light source. clear covercomplete as specified and as directed by Engr-in-Charge. Make: HAVELLS Cat NoRUBYNXTPT15WLED730PSYMTOPC or equivalentapproved make |
| 69 | S&F in repairs, 600 mm x 600 mm size,surface mounted LEDluminaire of capacity30watt, with driver, for soft glare free light, AC 230 voltcomplete with all acessories and connections, complete all as specified & asdirected.Make:HAVELLS PLANO G2 SURFACE LED 2 X 2 PANELCat No PLANOSUR2X2PLS30WLED840G2S or equivalentapproved make |
| 70 | S&F in repairs, decorative gate light/ garden lightmade up of high grade unbreakable polycarbonate material suitable for and including retro fit 9W LED lamp B22 base including 20 mm dia light grade GI pipe 1.5 mtr in length including necessary PCC 1:3:6 type C2 in foundation of size 0.25m x 0.25m x 0.25m all as directed duly painted all as directed. Make HavellsRubix CAT part No LHFOGAE1T11Q020Note:- Cost of Excavation and PCC for GI pipe is deemed to be included in quoted rates. |
| 71 | Inspection, maintenance and servicing of DG set, 320 KVA monthly , Make : GREAVES POWER, Model no. EKAG1051 (Bhingar pump house)including alternator, electric panel board connection to DG Set for routine check (\"A\" check) monthly of DG set for smooth functioning and carriying out maintenance as under :-Monthly Service(a)Checking engine oil level and topping up as and when requiredNOTE : Oil shall be measured and paid separately(b) Checking and adjusting the belt for tension and replacemnt of beltNOTE: Belt shall be measured and paid separately (c) Checking of oil bath air cleaner level (d) Checking of exhaust system for leakage(e) Draining of sediment from fuel filter and fuel tank(f) Cleaning of air cleaner element. |
| 72 | Note : Replacement of Air Cleaner shall be measured and paid separately. (g) Checking engine alternator coupling, mounting boltsand alignment.(h)Tighting all nut, bolts, in alternator terminal block.(j)Checking ofalternator carbon brush and connections in alternator (k)Checking and tighting of all connection in DC control wiring.(l)Checking ofall radiator rubber hose and replacementif required.NOTE : Hose pipes shall be measured and paid separately(m)Checking and recording oil pressure, water and oil temperature(n) Checking anti vibration mounting and replacement if required.NOTE: Antivibration pad shall be measured and paid separately (o) Checking throttle linkage (p) Checking battery for cell test, electrolyte level, gravity and topping up to required level(q) Routine check / repair work of panel, switch, MCCB, main switch, all contactor, engine control unit. |
| 73 | All as per serial item No. 71 but for 320KVA DG set, Make ; Greaves Model No EKAG 1049 (Bhingar PH) |
| 74 | All as per serial item No. 71 but for 200 KVA DG set, Make ; KIRLOSKAR, Model 6SL1500TA (DAD office area) |
| 75 | All as per serial item No. 71 but for 160 KVA DG set, Make ; KIRLOSKAR Model 6SL1080TA (Dhobighat PH) |
| 76 | All as per serial item No. 71 but for 160 KVA DG set, Make ; KIRLOSKAR Model 6SL9088 (Dhobighat PH) |
| 77 | All as per serial item No. 71 but for 160 KVA DG set, Make ; Greaves Model 6G11TAG26 (KLP PH) |
| 78 | All as per serial item No. 71 but for 125 KVA DG set, Make ;Kirloskar Model No 6R1080TA (AC depot PH) |
| 79 | All as per serial item No. 71 but for 100 KVA DG set, Make ;Kirloskar Model No KG225L (KLP PH) |
| 80 | Material and labour required for `B\" CHECKinspection once in six month, maintenance, servicing of DG set 320 KVAMake : GREAVES POWER, Model no. EKAG1051 (Bhingar pump house)includingitems covered in `B\" check of DG set for smooth functioning and carriying out maintenance complete all as per OEM instructions and as directed under :- (a) Repeat the activities of \"A\" check (b)Replacing lubricant oil Note:- Lub Oil are Paid separately. (c) Replacing lubricant oil filter element with `O\" ring(d) Replacing fuel filter element(e) Replacing Bypass Filter (f) Replacing Air Filter(g) Replacing Governer oil (h) Replacing coolant NOTES :i) `B\" CHECK ONCE INSIX MONTH OR 300-350 HRS RUNNING OF DG SET WHICHEVER IS EARLIER ii) `B\" check kit, coolant, Lubricant Oil shall be measured and paid seperately under relevant item. |
| 81 | All as per serial item No. 79 but for 320KVA DG set, Make ; Greaves Model No EKAG 1049 (Bhingar PH) |
| 82 | All as per serial item No. 79 but for 200 KVA DG set, Make ; KIRLOSKAR, Model 6SL1500TA (DAD office area) |
| 83 | All as per serial item No. 79 but for 160 KVA DG set, Make ; KIRLOSKAR Model 6SL1080TA (Dhobighat PH) |
| 84 | All as per serial item No. 79 but for 160 KVA DG set, Make ; KIRLOSKAR Model 6SL9088 (Dhobighat PH) |
| 85 | All as per serial item No. 79 but for 160 KVA DG set, Make ; Greaves Model 6G11TAG26 (KLP PH) |
| 86 | All as per serial item No. 79 but for 125 KVA DG set, Make ; Kirloskar Model No 6R1080TA (AC depot PH) |
| 87 | All as per serial item No. 79 but for 100 KVA DG set, Make ; Kirloskar Model No KG225L (KLP PH) |
| 88 | Supply only B\" Check Kit for DG set 320 KVA Make ; GREAVES POWER, Model no. EKAG1051 (Bhingar pump house) complete allas per OEM instructions and as specified and as directed.Note : Quoted rate shall be included for oil filter (1.00 Ltr/0.5 ltr), Diesel filter, coolent |
| 89 | All as per serial item No. 87 but for 320KVA DG setMake ; Greaves Model No EKAG 1049 (Bhingar PH) |
| 90 | All as per serial item No. 87 but for 200 KVA DG setMake ; KIRLOSKAR, Model 6SL1500TA (DAD office area) |
| 91 | All as per serial item No. 87 but for 160 KVA DG set Make ; KIRLOSKAR Model 6SL1080TA (Dhobighat PH) |
| 92 | All as per serial item No. 87 but for 160 KVA DG set Make ; KIRLOSKAR Model 6SL9088 (Dhobighat PH) |
| 93 | All as per serial item No. 87 but for 160 KVA DG set Make ; Greaves Model 6G11TAG26 (KLP PH) |
| 94 | All as per serial item No. 87 but for 125 KVA DG set Make ;Kirloskar Model No 6R1080TA (AC depot PH) |
| 95 | All as per serial item No. 87 but for 100 KVA DG set Make ;Kirloskar Model No KG225L (KLP PH) |
| 96 | Disconnecting all the connections from alternator of320/200 KVADG set,removing the alternator from foundations , transporting to workshop, dismaintling completely including starter, roter, removing rotor and bearing, cleaning all the parts with thinner and varnishing completely with F class varnishing, applying expoxy coating, rewinding & reassembling, dynamically balancing the alternator transporting and fixing on frame and reallignment within tolerance limit , connecting the alternator with all connections and testing on load completely all as specified and as directed. |
| 97 | All as per item No 95 above but for alternator 160/125/100 KVA complete all as directed. |
| 98 | M&L in repair/replacement, anti vibration mountingof DG Sets of capacity 100/125/160 KVA including connecting and testing all as specified and as directed. |
| 99 | M&L in repair/replacement, anti vibration mountingof DG Sets of capacity 200/320 KVA including connecting and testing all as specified and as directed. |
| 100 | M&L in repair/replacement, battery Lead with Brass Terminals of DG Sets of capacity 100/125/160 KVA all as specified and as directed. |
| 101 | M&L in repair/replacement, emergency shutdown switch with wiring of DG Set 100 KVA to 320 KVA all as specified and as directed. |
| 102 | M&L in repair/replacement, fan belt of DG set 320/200 KVA all as specified and as directed. |
| 103 | M&L in repair/replacement, fan belt of DG Set 100/125/160 KVA all as specified and as directed. |
| 104 | M&L in repair/replacement, oil seal of DG Set 100 KVA to 320 KVA all as specified and as directed. |
| 105 | M&L in repair/replacement, binjo bolt for pipe of DG Set 100 KVA to 320KVA all as specified and as directed. |
| 106 | M&L in repair/replacement, fuel level float ball of DG Set 320/200 KVA all as specified and as directed. |
| 107 | M&L in repair/replacement, fuel level float ball of DG Set 100/125/160 KVA all as specified and as directed. |
| 108 | M&L in repair/replacement, radiator hose pipe set with clamps of DG Set 300/200 KVA all as specified and as directed. |
| 109 | M&L in repair/replacement, radiator hose pipe set with clamps of DG Set 100/125/160 KVA all as specified and as directed. |
| 110 | M&L in repair/replacement, air filter hose pipe set with clamps of DG Set 320/200 KVA all as specified and as directed. |
| 111 | M&L in repair/replacement, air filter hose pipe set with clamps of DG Set 100/125/160 KVA all as specified and as directed. |
| 112 | M&L in repair/replacement, radiator fan metalic of DG Set 320/200 KVA all as specified and as directed. |
| 113 | M&L in repair/replacement, radiator fan metalic of DG Set 100/125/160 KVA all as specified and as directed. |
| 114 | M&L in repair/replacement, radiator fan drive pulley of DG Set 320/160 KVA all as specified and as directed. |
| 115 | M&L in repair/replacement, radiator fan drive pulley of DG Set 100/125/160 KVA all as specified and as directed. |
| 116 | M&L in repair/replacement, starter / solenoid complete Assembly of DG Set 320/200 KVA all as specified and as directed. |
| 117 | M&L in repair/replacement, starter / solenoid complete Assembly of DG Set 100/125/160 KVA all as specified and as directed. |
| 118 | M&L in repair/replacement, Left/Right hand door locks with catcher.of DG Set 100KVA to 320 KVA all as specified and as directed. |
| 119 | M&L in repair/replacement, start push button with assembly and make DG easily start for DG Set 200/320 KVA completeall as specified and as directed. |
| 120 | M&L in repair/replacement, start push button with assembly and make DG easily start for DG Set 100/125/160 KVA completeall as specified and as directed. |
| 121 | M&L for leakage rectification of radiator, cleaning, pressure testing etc for any make and capacity DG Set complete as required and directed. |
| 122 | M&L in repair/replacement, battery charger 12 V DC SMPS 10 Amp for AMF panel all as specified and as directed. |
| 123 | M&L in repair/replacement, battery charger 24 V DC SMPS 20 Amp for AMF panel all as specified and as directed. |
| 124 | M&L in repair/replacement of existing unsv wireinsde AMF panel of DG Set 300/200 KVA all as specified and as directed. |
| 125 | M&L in repair/replacement, of existing unsv wireinsde existing model for AMF panel of DG Set 100/125/160 KVA all as specified and as directed. |
| 126 | M&L for scraping, cleaning of old steel surface and painting with two coats of synthetic enamel paint over a coat of red oxide primer on DG sets of any Make & Capacity all as specified and as directed. |
| 127 | M&L for bearing grease HP/BP type servo Gem Natra-3/Lithon-3all as specified and as directed. |
| 128 | M&L for engine oil 20W40 of approved and standard in seal packed containers all as specified and as directed. Make : Servo/ BPL/IOC/ Castrol |
| 129 | M&L for topping up/ replacement of insulating oil of stabilizer chamber with new insulating/transformer oil upto the required level in any type and capacity of voltage stabilizer all as directed. Note:- insulating/ transformer oil must be in seal packed in drum having ISI mark compelte |
| 130 | Repai/serviceing to voltage stabilizer 3 phase 4 wire system 160 to 300 KVA at site by opening carefully from top, taking out coils/connections, cleaning coils checking defective joints/ soldering/ jointing, re-assembleing and testing on full load and making fully serviciable incl spray painting with super enamlled paint of colour as directed complete all as specified and directed. |
| 131 | M&L for coolant of approved and standard in seal packed containers all as specified and as directed. |
| 132 | Supply only battery water with electrolyte mix all as specified and as directed. |
| 133 | S&F in repair/replacement, of battery 12 V, Capacity XP1800 or180 AH, maintenance free battery, 12 Volt initially charged with suitable size of copper leads and brass terminals with 36 month warranty complete as directed by Engr-in-Charge. Make: Exide/ Amaron/ Luminous |
| 134 | Taking LT shutdown, complete checking of AMF panel, finding the fault, servicing complete including fixing in repair/ replacement of unserviceable spares with necessary wiring and testing complete for manual & Auto operations all as directed.Note:- Items required for replacement will be measured & paid seperately as \"Supply only\" under respective item of BOQ |
| 135 | Supplyonly AMF panel timer and over voltage timing relay as per existing type, make and capacity all as specified and as directed. |
| 136 | Supplyonly AMF panel timer relay for circuit 230 V AC supply as per existing type, make and capacity all as specified and as directed. |
| 137 | Supplyonly AMF panel relay card 12 V DC supply for change over as per existing type, make and capacity all as specified and as directed. |
| 138 | Supplyonly AMF panel relay single with batch 8 pin 230 V AC supply as per existing type, make and capacity all as specified and as directed. |
| 139 | Supplyonly selector switch with elements for controlling Auto/ Manual position of AMF panel of any make and capacity all as specified and as directed. |
| 140 | Supplyonly Start/ Stop switch with elements of AMF panel of any make and capacity all as specified and as directed. |
| 141 | Supplyonly solenoid switch for use of engine stop of AMF panel of any make and capacity all as specified and as directed. |
| 142 | Supplyonly Volt meter digital type of range 0-500 volts of panel all as specified and as directed. |
| 143 | Supplyonly Amp meter digital type of existing make,model and capacity of panel all as specified and as directed. |
| 144 | Supplyonly Indicator lamp 230 V AC Supply of panel all as specified and as directed. |
| 145 | Supplyonly AMF panel MCCB, 3 pole, 160 Amp, 16 KAall as specified and as directed. |
| 146 | Supplyonly MCCB, 3 pole,125 Amp,16 KA all as specified and as directed. |
| 147 | M&L in repairs/replacement, broken canopy door hinges and Glasses of any capacity DG set ofany capacity and make. Setting of conopy door, properly locking arrengement, welding Brazing of broken parts/body etc complete all as directed by Engr-in Charge |
| 148 | M&L in repairs/replacement, for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6.0m m burieddirectly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including galvanized earth strip 25mmx4mmupto 7.5 m by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 32mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, charcoal,salt etcRCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate)including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified and as directed. |
| 149 | S&F in repair/replacement, contactor 40 Amps, 4 pole, 415 volts fixing with existing box with suitable size of copper cableand lugs all as specified and directed . |
| 150 | S&F in repair/replacement, contactor 63 Amps, 4 pole, 415 volts fixing with existing box with suitable size of copper cableand lugs all as specified and directed . |
| 151 | S&F in repairs,MCB TPN 16-32 Amps, 415 Volts, 50 Hz AC supply systemall as specified and as directed. |
| 152 | S&F in repairs, MCB TPN 40-100 Amps, 415 Volts, 50 Hz AC supply systemall as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail