| 1 | Taking down copper/aluminium point wiring (light, fan, socket,bell,power point) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 2 | Material and labour for point wiring for one light/fan point with 1.5 Sq.mm PVC insulated (FRLSH) unsheathed copper conductor multistranded 1100 volts grade controlled by one way switch including 1.5 Sq.mm PVC (FRLSH) insulated unsheathed copper cable multistranded conductor 1100 volts grade for continuity conductor including connected to common earth dolly drawn through and including rigid PVC conduit 20mm dia medium grade ISI marked concealed of suitable size with all accessories and suitable factory made modular box for mountingof switch, socket and fan regulator with modular frames covers includingchase cutting and making good to the disturbed surfaces and matching to the existing finishes specifications complete all as specified and directed. |
| 3 | All as per item No. 2 here in before but for one bell pointcontrolled by one 5 Amp bell push on independentboard complete all as specified and directed. |
| 4 | All as per item No. 2 here in before but for one 5pin5 Amp socket outlet point on independentboard complete all as specified and directed. |
| 5 | All as per item No. 2 here in before but for one 5 pin5 Amp socket outlet point on the same board complete all as specified and directed. |
| 6 | All as per Item No.2here-in-before but using 2.5 Sq.mm copper conductor(mulitstranded) PVC insulatedFRLSH unsheathed cableincluding 2.5 Sq.mmcopper conductor cable(mulitstranded) PVC insulatedFRLSH unsheathed cable as earth wire with terminal box of suitable size of modular switch & socket for one 6 pin 15 amp socket outlet point on independent board complete all as specified and directed. |
| 7 | S&F modular Bell Push 6A, 1 module, complete all as specified and directed. |
| 8 | S&F modular switch6 Amps 240 volts one way switch complete all as specified and directed. |
| 9 | S&F Switch modular type AC 240 Volts 16 Amps one way complete all as specified and directed. |
| 10 | S&F Socket 6A-2/3 pin combined AC 240 Volts modular type complete all as specified and directed. |
| 11 | S&F Socket 16 Amp-5 pin combined AC 240 Volts modular type complete all as specified and directed. |
| 12 | S&F Socket 6 Amps 240 Volts one Way switch complete all as specified and directed. |
| 13 | S&F switch piano type 6 Amps 240 Volts one way switch complete all as specified and directed. |
| 14 | S&F bell push flush type 5 Amps single pole complete all as specified and directed. |
| 15 | S&F fan regulator electronic step type 120 W, 250 Volts complete all as specified and directed. |
| 16 | S&F in repair, switch piano flush type single pole one way 15 Amp complete all as specified and directed. |
| 17 | S&F in repair, switch socket combination 5 Amps, 5 pin, 2 in 1 complete all as specified and directed. |
| 18 | S&F in repair ceiling rose surface bakelite 65x50 mm, 3 terminals complete all as specified and directed. |
| 19 | S&F in repair, electric bell ,Buzzer,Ding dong AC 230 Volt single pole complete all as specified and directed. |
| 20 | S&F in repair SPN enclosure withtwo pin and earth plug and socket complete with one SP MCB, 20 Amps having breaking capacity 10 kA, complete all as specified and directed. |
| 21 | S&F in repair triple pole enclosure withthree pin and earth plug and socket complete with one TP MCB, 20 Amps having breaking capacity 10 kA,complete all as specified and directed. |
| 22 | S&F in repair triple pole enclosure withthree pin and earth plug and socket complete with one TP MCB, 63 Amps having breaking capacity 10 kA, complete all as specified and directed. |
| 23 | S&F Sheet Metal Enclosure for MCB DB, SPN 4 Ways double door,with 200 Amps rated bus bar , having IP-43 protection including taking down of old DB complete all as specified and directed. |
| 24 | S&F Sheet Metal Enclosure for MCB DB, SPN 8 Ways double door,with 200 Amps rated bus bar , having IP-43 protection including taking down of old DB complete all as specified and directed. |
| 25 | S&F Sheet Metal Enclosure for MCB DB, SPN 12 Ways double door,with 200 Amps rated bus bar , having IP-43 protection including taking down of old DB complete all as specified and directed. |
| 26 | S&F Sheet Metal Enclosure for MCB DB, TPN 4 Ways double door,with 200 Amps rated bus bar , having IP-43 protection including taking down of old DB complete all as specified and directed. |
| 27 | S&F 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SP 5 to 32 amp current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 28 | S&F 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SPN 32 Amps current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 29 | S&F 415V 10KA \"C\" curve miniature circuit breaker (MCB) of TP 25 to 63 Amps current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed. |
| 30 | S&F 415V 10KA \"C\" curve miniature circuit breaker (MCB) of TPN 40 to 100 Amps current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed. |
| 31 | S&F MCCB 3P 100 Amps thermal magnetic 25 kA complete all as specified and directed. |
| 32 | S&F light fitting 20 W, high performance batten, 220 Volt, 50 Hz, 6000 k 120 Iu/W surface mounted high qualityextruded polycarbonate , environmental friendly, energy efficient, with all connecting accessories, with suitable connection complete all as specified and directed. |
| 33 | S&F in replacement mirror light 10 Watt 50 Hz,230 volts with all accessories and connection to the electric circuit complete all as specified and directed. |
| 34 | S&F in replacement mirror light 12 Watt 50 Hz,230 volts with all accessories and connection to the electric circuit complete all as specified and directed. |
| 35 | S&F in repair recess mounted commercial luminaire 36 Watt,50 Hz, 220 Volts, 5700K LED down lighter 2\"x2\", complete all as specified and directed. |
| 36 | S&F in repair LEDFlood light 30 Watt, 50 Hz,220 Volts having IP-66 Protection , pressure die cast aluminium housing,high luminious efficiancy and high power complete all as specified and directed. |
| 37 | S&F in repair LEDFlood light 50 Watt, 50 Hz,220 Volts having IP-66 Protection , pressure die cast aluminium housing, high luminious efficiancy and high power complete all as specified and directed. |
| 38 | S&F in repair LEDFlood light 100 Watt, 50 Hz,220 Volts having IP-66 Protection , pressure die cast aluminium housing,high luminious efficiancy and high power complete all as specified and directed. |
| 39 | S&F in repair LED Building Security Light60 Watts, 50 Hz, 220 Volts having IP-65 Protection , pressure die cast aluminium housing,high luminious efficiancy and high power complete all as specified and directed. |
| 40 | S&F in repair LED Building Security Light45 Watts, 50 Hz, 220 Volts having IP-65 Protection , pressure die cast aluminium housing,high luminious efficiancy and high power complete all as specified and directed. |
| 41 | S&F in repair 15 Watt recessed round down lighter with high luminous LED for indoor application, 230 Volts, 50 Hz , min 120 lm/watt with all accessories and connection to the electric circuit complete all as specified and directed. |
| 42 | S&F in repair 12 Watt square recessed mounted down lighter with high luminous LED for indoor application, 230 Volts, 50 Hz , min 120 lm/watt with all accessories and connection to the electric circuit complete all as specified and directed. |
| 43 | S&F in repair 12 Watt recessed round down lighter with high luminous LED for indoor application, 230 Volts, 50 Hz , min 100 lm/watt with all accessories and connection to the electric circuit complete all as specified and directed. |
| 44 | S&F in repair bed side lamp 3 Watt 50 Hz,230 Volts, 3000 k with all accessories and connection to the electric circuit complete all as specified and directed. |
| 45 | S&F in repair 15 Watt LED bulb 230 Volts, 50 Hz with min 120 lumen/wattmust match with the exiting lamp holder with necessary fixtures and fittings complete all as specified and directed. |
| 46 | S&F in repair 12 Watt LED bulb 230 Volts, 50 Hz with min 120 lumen/wattmust match with the exiting lamp holder with necessary fixtures and fittings complete all as specified and directed. |
| 47 | S&F in repair ceiling light driver upto 6 Watt with all accessories and connection to the electric circuit complete all as specified and directed. |
| 48 | S&F in repair ceiling light driver 9 to 12 Watt with all accessories and connection to the electric circuit complete all as specified and directed. |
| 49 | S&F in repair ceiling light driver 15 to 18 Watt with all accessories and connection to the electric circuit complete all as specified and directed. |
| 50 | S&F in repair ceiling fans complete with blades,down rods,electronic regulator and accessories,230 V,1200 mm sweep,Min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete all as specified and directed. Note: The old ceiling fan shall be deposited to AGE(E/M) storeyard. |
| 51 | S&F in repair exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers complete all as specified and directed.Note: The old ceiling fan shall be deposited to AGE(E/M) storeyard. |
| 52 | S&F in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified and directed.Note: The old ceiling fan shall be deposited to AGE(E/M) storeyard. |
| 53 | S&F in repair Wall mounted fans 300 mm sweep, 230 V, 50 Hz complete all as specified and directed. Note: The old ceiling fan shall be deposited to AGE(E/M) storeyard. |
| 54 | S&F in repair, capacitor for ceiling fans,230 Volts, 2.5 MFD including necessary solderingcomplete all as specified and directed. |
| 55 | Taking down unserviceable ceiling fan of 1200/1400 mm sweep, cutting out the existing burnt out fan motor winding, cleaning the motor slots, rewinding the motor with insulated copper winding wire of existing gauge, baking/heating up the motor to achieve the proper insulation resistance and re-hanging /refixing after repair including applying a coat of synthetic enamel paint (Glossy Finish) with spray gun, marking MES No complete all as specified and as directed by Engr-in-Charge. |
| 56 | All as per item No. 55 here in before but exhaust fan of 250 mm sweep complete all as specified and as directed by Engr-in-Charge. |
| 57 | All as per item No. 55 here in before but wall mounted fan of complete all as specified and as directed by Engr-in-Charge. |
| 58 | S&F in repair exhaust motor for PVC type exhaust fan of size 200/250/300 mm sweep complete all as specified and directed by Eng-in-charge. |
| 59 | S&F in repair exhaust motor for steel body type exhaust fan of size 250/300/350 mm sweep complete all as specified and directed by Eng-in-charge. |
| 60 | M&L for checking of ceiling fans stability (like fan hooks,nuts,bolts,hanging rod, canopy,washer etc) exhaust fan stability, loose connection in distribution boars,MCBs in Qtrs complete all as specified and as directed by Engineer-in-Charge.NOTE: 1. The material incorporated for completion ofwork will be measured and paid separately under relevant item.2.The contractor should prepare a registerand enter office name with signature Officer in Chargeand submitted to Engineer-in-Charge. |
| 61 | Material, Labour including transportation of tools for rectification of urgent natureof electrical complaints like checking of existing electrical items for continuous electric supply including carrying out minor repairs such as changing of MCBs, small pieces of wires including connections etc carrying out repairssuch astightening of loosen electric connections,nuts,bolts, screws of switches,sockets, switch boards,making joints and covering with PVC tape, minor repairsto ceiling fans/exhaust fans like replacement of capacitors,cleaning and oiling etc, as required m to make the electrical items/appliances fully functional at K Area during off hours (1700 hrs evening to 0900 hrs morning) on all working days all as specified and as directed by Engineer-in-Charge.NOTE:-(i) The material incorporated for completion of work will be measured and paid seperately under relevent item.(ii) The contractor should display contact number at complaint cell to register users complaint(iii)The recovery of rupees 1000 per complaints will be charged if contractor failed to attend the instipulated time period/.(iv) Number of complaints may vary day to day and shall be on required basis. |
| 62 | Material, Labour including transportation of tools for rectification of urgent natureof electrical complaints like checking of existing electrical items for continuous electric supply including carrying out minor repairs such as changing of MCBs, small pieces of wires including connections etc carrying out repairssuch astightening of loosen electric connections,nuts,bolts, screws of switches,sockets, switch boards,making joints and covering with PVC tape, minor repairsto ceiling fans/exhaust fans like replacement of capacitors,cleaning and oiling etc, as required m to make the electrical items/appliances fully functional at K Area during off days incudling sunday and holiday days complete all as specified and as directed by Engineer-in-charge.NOTE:-(i) The material incorporated for completion of work will be measured and paid seperately under relevent item.(ii) The contractor should display contact number at complaint cell to register users complaint(iii)The recovery of rupees 1000 per complaints will be charged if contractor failed to attend the instipulated time period/.(iv) Number of complaints may vary day to day and shall be on required basis. |
| 63 | S&F in repair AC single phase static energy meter of accuracy class 1.0 , rating 5 to 30 Amp , 250 Volts,50 Hz only KWHr compact meter with pilfer proof meter box with ceiling screw provision ( LCD Mni) complete all as specified and directed. |
| 64 | S&F in repair AC three phase static energy meter of accuracy class 1.0 , 3 Phase , 415 Volts , with backlit LCD display of rating 10- 60 Amp , 250 Volts,50 HzKWHr compact meter with pilfer proof meter box with ceiling screw provision ( LCD Mni) complete all as specified and directed. |
| 65 | M&L for rigid non metallic PVC medium grade conduit including junction boxes,tee,bends, elbows,reducers ,bell mouth tube ends,fixing accessorires such as couplers,lock nuts,saddle pipe hook etc for 25 mm dia. ISI marked complete all as specified and directed. |
| 66 | M&L for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized iron wire 4mm diaas earthup to 7.5 mdistance and connected by means of bolts, nuts, checknuts and washers of galvanisediron or steel all shown in electric plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including provision of necessary excavation and earth work in any type of soil, PCC pit , RCC cover 50 mm thick, reinforced with8 mm dia TMT barsboth ways @ 10 CM c/c ,20 mm bore medium grade watering pipe, water funnel, 40 mm bore GI medium grade protection pipe, common salt, charcoal dust, returning, filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc including testing on completion complete all as specified and as directed by Engr-in-Charge. Note :- (i)The unit rate includes for protection pipe and earth lead upto 7.50 Mtr.(ii) Earth lead beyond 7.50 Mtr length shall be measured and paid separately. |
| 67 | M&L for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to GI Strip 25X4 mm as earthup to 7.5 mdistance and connected by means of bolts, nuts, checknuts and washers of galvanisediron or steel all shown in electric plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including provision of necessary excavation and earth work in any type of soil, PCC pit , RCC cover 50 mm thick, reinforced with8 mm dia TMT barsboth ways @ 10 CM c/c ,20 mm bore medium grade watering pipe, water funnel, 40 mm bore GI medium grade protection pipe, common salt, charcoal dust, returning, filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc including testing on completion complete all as specified and as directed by Engr-in-Charge. Note :- (i)The unit rate includes for protection pipe and earth lead upto 7.50 Mtr.(ii) Earth lead beyond 7.50 Mtr length shall be measured and paid separately. |
| 68 | S&F in repair, on wall/ concealed on wall, 40mm dia. High pressure CPVC pipes SDR-13.5 & Plain CPVC SDR 11 fittings including all necessary fittings, solvents, complete all as specified and directed. |
| 69 | S&F in repair, on wall/ concealed on wall, 25mm dia. High pressure CPVC pipes SDR-13.5 & Plain CPVC SDR 11 fittings including all necessary fittings, solvents, complete all as specified and directed. |
| 70 | S&F in repair, on wall/ concealed on wall, 20mm dia. High pressure CPVC pipes SDR-13.5 & Plain CPVC SDR 11 fittings including all necessary fittings, solvents, complete all as specified and directed. |
| 71 | S&F in repair, 15mm size Chromium Plated fancy type Bib Taps, quarter turn with flange and aerator, short body, cast copper alloy with crutch or butterfly handle, screwed for GI/ CPVC pipe, complete all as specified and directed.Make : Cera Cat. Part No. F2013151 or any other equivalent make from the approved list of manufactures. |
| 72 | S&F in repair, 15mm size Chromium Plated fancy type Bib Taps, quarter turn with flange and aerator, long body, cast copper alloy with crutch or butterfly handle, screwed for GI/ CPVC pipe, complete all as specified and directed.Make : CERA Cat. Part No. F1017152 or any other equivalent make from the approved list of manufactures. |
| 73 | S&F in repair, 15mm size Chromium Plated cast copper alloy Two way Bib Cock, quarter turn with flange and aerator, complete all as specified and directed.Make : CERA Model No. F1017211 or any other equivalent make from the approved list of manufactures. |
| 74 | S&F in repair, 20mm size Chromium Plated cast copper alloy, fancy type, quarter turn Concealed Stop Cock, with CP cup and adjustable wall flange, complete all as specified and directed. Make : CERA Model No. F2002362 or any other equivalent make from the approved list of manufactures. |
| 75 | S&F in repair, 15mm size Chromium Plated cast copper alloy Angle Valve, half turn with flange, for fixing with CPVC pipe, complete all as specified and directed.Make : CERA Model No. F2002201 or any other equivalent make from the approved list of manufactures. |
| 76 | S&F in repair, 15mm size Swivel Overhead Shower (minimum weight 40 grams) of PTMT, any colour with shower arm (minimum weight 40 grams) 195mm long with bend of 45 degree with flange, fixing with CPVC Pipe, complete all as specified and directed.Make : CERA Model No. F 7020104 or any other equivalent make from the approved list of manufactures. |
| 77 | S&F in repair, 90mm dia. Hand Shower with 125 mm long arms, complete all as specified and directed.Make : CERA Model No. F7030105 or any other equivalent make from the approved list of manufactures. |
| 78 | S&F in repair, 450mm long, 15mm dia. PVC Connection with brass union on both sides to suit 15mm GI pipe, complete all as specified and directed. |
| 79 | S&F in repair, Health Faucet, ABS body with wall hook and one metre SS braided rubber hose pipe, complete all as specified and directed.Make : CERA Model No. F8030111AB or any other equivalent make from the approved list of manufactures. |
| 80 | S&F in repair, 15mm bore Chromium Plated fancy type, cast copper alloy Pillar Taps, quarter turn with aerator, with capstan heads, screwed down, high pressure with or without lettered \"Hot\" or \"Cold\", with long screwed shanks and fly nuts screwed for iron pipe and fixed, complete all as specified and directed.Make : CERA Model No. 2006101 or any other equivalent make from the approved list of manufactures. |
| 81 | S&F in repair, Wall Mixer (3-in-1) with arrangement of both Telephonic Shower and Over Head Shower, with 210mm long bend pipe, complete all as specified and directed.Make : CERA Model No. F1015403 or any other equivalent make from the approved list of manufactures. |
| 82 | S&F in repair, Chromium Plated cast copper alloy Kitchen Sink Cock, quarter turn, wall mounted with swivel spout not less than 150 mm and wall flange complete all as specified and directed.Make : Model No. F2014261 of CERA or any other equivalent make from the approved list of manufactures. |
| 83 | M&L for cutting chases on walls, floors etc. not exceeding 10cm girth and making good the disturbed surface to match with the existing surface after removing the existing concealed pipe/ laying new pipe, complete all as specified and directed. |
| 84 | S&F in replacement, 2000 litres capacity Rotational Moulded Polyethylene Water Storage Tanks (Cylindrical, vertical with closed top), hoisted & fixed in position, complete all as specified and directed. |
| 85 | S&F in replacement, 1000 litres capacity Rotational Moulded Polyethylene Water Storage Tanks (Cylindrical, vertical with closed top), hoisted & fixed in position, complete all as specified and directed. |
| 86 | S&F in replacement, 500 litres capacity Rotational Moulded Polyethylene Water Storage Tanks (Cylindrical, vertical with closed top), hoisted & fixed in position, complete all as specified and directed. |
| 87 | S&F in repair, 40mm dia. CPVC Ball Valve suitable for CPVC pipe including necessary fittings, complete all as specified and directed. |
| 88 | S&F in repair, 25mm dia. CPVC Ball Valve suitable for CPVC pipe including necessary fittings, complete all as specified and directed. |
| 89 | S&F in repair, 20mm dia. CPVC Ball Valve suitable for CPVC pipe including necessary fittings, complete all as specified and directed. |
| 90 | S&F in repair, 40 mm dia. Synthetic (PVC) Float Valve, high pressure, with polythene ball of size 6\" dia. and flynut, complete all as specified and directed. |
| 91 | S&F in repair, 25 mm dia. Synthetic (PVC) Float Valve, high pressure, with polythene ball of size 6\" dia. and flynut, complete all as specified and directed. |
| 92 | S&F in repair, 20 mm dia. Synthetic (PVC) Float Valve, high pressure, with polythene ball of size 6\" dia. and flynut, complete all as specified and directed. |
| 93 | Material, labour, transport and tools for rectification of urgent nature Water Supplycomplaintslike Pipe breakdown, Air problem etc. at Naval Base as and when required (K Area) as and when required during all working days, Sundays/ Holidays/ Off hours of all working days, all as directed by Engineer in Charge.NOTE:(i) The material incorporated for completion of work will be measured and paid separately under relevant item.(ii) The contractor should display contact number at L & M Area to register users complaint.(iii)The recovery of Rs. 1000/- per complaint will be chargeable if contractor fails to attend complaint. |
| 94 | Taking down defective Geyser of 25/ 50 litres capacity from its existing position at any height duly disconnecting inlet/ outlet water connection and opening up geyser for checking defective parts and replacing the defective parts with new parts, including testing and commissioning the same after successful repairing, complete including refixing the same on its existing position and making connection inlet/ outlet water connection, complete all as specified and directed by Engineer in Charge.Note : The spares required for servicing the geyser shall be measured and paid separately under relevant item of the schedule as \"supply only\". The labour required for replacing spares shall include in this item. |
| 95 | Supply only Thermostat suitable for 25 litres and 50 litres capacity Geyser, any make/ type, complete all as specified and directed. |
| 96 | Supply only Heating Element 1.5 KW/ 2 KW, ISI marked for 25 litres and 50 litres capacity Geyser, any make/ type complete all as specified and directed. |
| 97 | Supply only Gasket for 25 litres and 50 litres capacity Geyser, complete all as specified and directed. |
| 98 | Supply only 12mm dia. Chromium Plated Pipe for \"Hot and Cold\" water, of suitable length, with two brass adopter and connecting up, complete all as specified and directed. |
| 99 | Supply only Indicating Lamp suitable for 25 litres and 50 litres capacity Geyser, complete all as specified and directed. |
| 100 | M&L for scrubbing, cleaning thoroughly, removing all scale and dirt, mud sediments, silts etc.,from the internal surfaces of HDPE Storage Tanks below 500 Litres (bottom and wall) by using brushes, bleaching powder and other cleaning materials as required, including writing the words \"DATE OF CLEANING\" in capital letters of suitable size on outside visible place of Water Tank with synthetic enamel paint (white) over black background, complete all as specified and directed. |
| 101 | M&L for scrubbing, cleaning thoroughly, removing all scale and dirt, mud sediments, silts etc.,from the internal surfaces of HDPE Storage Tanks below 1000 Litres (bottom and wall) by using brushes, bleaching powder and other cleaning materials as required, including writing the words \"DATE OF CLEANING\" in capital letters of suitable size on outside visible place of Water Tank with synthetic enamel paint (white) over black background, complete all as specified and directed. |
| 102 | M&L for scrubbing, cleaning thoroughly, removing all scale and dirt, mud sediments, silts etc.,from the internal surfaces of HDPE Storage Tanks below 2000 Litres (bottom and wall) by using brushes, bleaching powder and other cleaning materials as required, including writing the words \"DATE OF CLEANING\" in capital letters of suitable size on outside visible place of Water Tank with synthetic enamel paint (white) over black background, complete all as specified and directed. |
| 103 | S&F in replacement, Automatic Pressure Switch for 0.50HP to 2HP Booster Pump complete all as specified and directed. |
| 104 | S&F in replacement, Manifolder/ Connector Assembly suitable for 5 way Booster Pump, complete all as specified and directed. |
| 105 | S&F in replacement, 25mm Non Return Valve for Booster Pump, complete all as specified and directed. |
| 106 | S&F in replacement, Pressure Gauge 0-5 Kg/cm2 for Booster Pump, complete all as specified and directed. |
| 107 | Material and labour for replacing all types of Spindle with washer of taps (Short body/ Long body tap, Angle Valve, Washing machine tap, Sink Cock etc.) including taking down,cleaning of tap and refixing after repair, complete all as specified and directed. |
| 108 | Material and labour for replacing all types of Spindle with washer of wall mixer taps (Short body/ Long body tap, Angle Valve, Washing machine tap, Sink Cock etc.) including taking down, cleaning of tap and refixing after repair, complete all as specified and directed. |
| 109 | S&F in replacement, rotate and lock type cover for 500 litres to 5000 litres capacity Over Head Water Tank (HDPE), complete all as specified and directed. |
| 110 | S&F in repair 25 litre capacity Electric Water Heater, Storage type, steel body with copper inner tank and heating element upto 2 KW, BEE 5 Star rated, with all accessories such as safety valve, thermostat, NRV, connection piece etc., complete all as specified and directed.Note: The old Electric water heater shall be deposited to AGE(E/M) storeyard. |
| 111 | S&F in repair centrifugal booster pump 1 HP, 0.75 KW, pressure setting range 2.0 to 4.5 kg/cm, tank capacity 24 ltrs ,rust preventive aluminium die casted motor body, fitted with hot water seal ,F-class insulation, suitable for hot water application complete all as specified and directed.Make: V-guard Cat part no. VB24F4A or any other equivalent make from the approved list of manufactures.Note :- (i) Quoted rate shall Include provision of suitable type PVC canopy for protection of booster pump as per direction by Engineer-in-Charge.(ii) Note: The old centrifugal pump shall be deposited to AGE(E/M) storeyard. |
| 112 | S&F in repair centrifugal booster pump 0.5 HP, 0.37 KW, pressure setting range 2.0 to 4.5 kg/cm, tank capacity 24 ltrs ,rust preventive aluminium die casted motor body, fitted with hot water seal, F-class insulation, suitable for hot water application all as specified and directed by engineer in charge.Make: V-guard Cat part no. VB24.H3A or any other equivalent make from the approved list of manufactures.Note :- (i) Quoted rate shall Include provision of suitable type PVC canopy for protection of booster pump as per direction by Engineer-in-Charge.(ii) Note: The old centrifugal pump shall be deposited to AGE(E/M) storeyard. |