| 1 | M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl PVC casing capping sleeves and caps of adequate width and length with all accessories and fittings like bends, elbow, crosses, etc. with PVC round block and PVC terminal boxes with 3.00mm thick laminated sheet cover for mounting fittings like; switches, sockets, fan regulator, etc. incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly for one light/ fan/ exhaust fan/ bell point controlled by one 1-way switch/ bell push including taking down the existing old unserviceable wiring connection with casing-capping/ conduit/ batten and switch board of any description with and including making good the disturbed surfaces (as/if requred),complete all as per specified and as directed by Engineer-in-Charge. |
| 2 | All as per Item No. 01 here-in-above, but for One 3 pin socket outlet, 5 Amps on the same board, complete all as specified and as directed by Engineer-in-charge. |
| 3 | All as per Item No. 01 here-in-above, but for One 3 pin socket outlet, 5 Amps, independent board, complete all as specified and as directed by Engineer-in-charge. |
| 4 | All as per Item No. 01 here-in-above, but for One 3/5 pin socket outlet, 15 Amps, independent board, with cables 4 sq. mm size, complete all as specified and as directed by Engineer-in-charge. |
| 5 | S&F of Switch piano, flush type single pole, One way 5/6 Amp, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge. |
| 6 | S&F of Socket outlet 3/5 pin, 5/6A, flush type, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge. |
| 7 | S&F of Switch socket combination 2 in 1, 3/5 pin, 15/16 Amp, flush type universal, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge. |
| 8 | S&F of Switch socket combination 2 in 1, 3/5 pin, 5/6A flush type, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge. |
| 9 | S&F of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd., 220-240V, AC, complete all as specified and as directed by Engineer-in-charge. |
| 10 | S&F of ceiling rose surface backelite three terminals, PVC/ polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge. |
| 11 | S&F in-repair of Switch piano, flush type single pole, One way 5/6 Amp, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge. |
| 12 | S&F in-repair of Socket outlet 3/5 pin, 5/6A, flush type, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge. |
| 13 | S&F in-repair of Switch socket combination 2 in 1, 3/5 pin, 15/16 Amp, flush type universal, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge. |
| 14 | S&F in-repair of Switch socket combination 2 in 1, 3/5 pin, 5/6A flush type, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge. |
| 15 | S&F in-repair of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd., 220-240V, AC, complete all as specified and as directed by Engineer-in-charge. |
| 16 | S&F in-repair of ceiling rose surface backelite three terminals, PVC/ polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge. |
| 17 | S&F in-repair of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge. |
| 18 | S&F in-repair of Bell push, flush type, 5/6 amp, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge. |
| 19 | S&F in-repair of Bell Buzzer/ Ding Dong, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge. |
| 20 | S&F in-repair of Modular Switch, One Module, 1-Way, 10 Amps, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed. |
| 21 | S&F in-repair of Modular Switch, One Module, 1-Way, 20 Amps, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed. |
| 22 | S&F in-repair of Modular Socket, 3 Pin, combined, Three Module, 10 Amp, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed. |
| 23 | S&F in-repair of Modular Socket, 2/3 Pin, combined, Three Module, 20 Amp, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed. |
| 24 | S&F in-repair of Modular stepped type electronic fan regulator, Two module, 120W, 240V, AC, complete all as specified and as directed by Engineer-in-charge. |
| 25 | S&F in-repair of fan capacitor of 3.15 mfd, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge. |
| 26 | S&F in-repair of Sub-main Wiring with 2-Runs of Single Core 10.0 Sq mm PVC insulated FRLSH multi-stranded 1100 Volts grade with Copper Conductor drawn through and including Non-metalic Rigid PVC Casing capping ISI marked and its Accessories including 1-Run of Single Core 10.0 Sq mm PVC insulated FRLSH unsheated multi-stranded 1100 Volts grade with Copper Conductor Cable as Earth Continuty Conductor along with the Wiring and connected from DB to DB/Main Board, complete all as specified and as directed.NOTE :- (a)Cost of PVC Casing capping with all Fittings/Accessories will deem to be included in the quoted UNIT RATE.(b)Cables as mentioned in SCHEDULE ‘A’ Items and 1-Run of PVC Casing capping with all Fittings/Accessories will be measured and paid as ONE UNIT.(c)Sub-main Wiring will be measured as length of PVC Casing capping only. Wire required for looping, etc as ordered will deem to be included in the quoted UNIT RATE. |
| 27 | S&F in-repair of Sub-main Wiring with 2-Runs of Single Core 6.0 Sq mm PVC insulated FRLSH multi-stranded 1100 Volts grade with Copper Conductor drawn through and including Non-metalic Rigid PVC Casing capping ISI marked and its Accessories including 1-Run of Single Core 6.0 Sq mm PVC insulated FRLSH unsheated multi-stranded 1100 Volts grade with Copper Conductor Cable as Earth Continuty Conductor along with the Wiring and connected from DB to DB/Main Board, complete all as specified and as directed.NOTE :- (a)Cost of PVC Casing capping with all Fittings/Accessories will deem to be included in the quoted UNIT RATE.(b)Cables as mentioned in SCHEDULE ‘A’ Items and 1-Run of PVC Casing capping with all Fittings/Accessories will be measured and paid as ONE UNIT.(c)Sub-main Wiring will be measured as length of PVC Casing capping only. Wire required for looping, etc as ordered will deem to be included in the quoted UNIT RATE. |
| 28 | S&F in-repair of Sub-main Wiring with 2-Runs of Single Core 4.0 Sq mm PVC insulated FRLSH multi-stranded 1100 Volts grade with Copper Conductor drawn through and including Non-metalic Rigid PVC Casing capping ISI marked and its Accessories including 1-Run of Single Core 4.0 Sq mm PVC insulated FRLSH unsheated multi-stranded 1100 Volts grade with Copper Conductor Cable as Earth Continuty Conductor along with the Wiring and connected from DB to DB/Main Board, complete all as specified and as directed.NOTE :- (a)Cost of PVC Casing capping with all Fittings/Accessories will deem to be included in the quoted UNIT RATE.(b)Cables as mentioned in SCHEDULE ‘A’ Items and 1-Run of PVC Casing capping with all Fittings/Accessories will be measured and paid as ONE UNIT.(c)Sub-main Wiring will be measured as length of PVC Casing capping only. Wire required for looping, etc as ordered will deem to be included in the quoted UNIT RATE. |
| 29 | S&F in-repair ofSheet Metal Enclosure MCB DB SPN, 2 way 240 volt, with rated Bus-bar, Single door type MCB DB suitable for mounting incoming and outgoingMCBs of any type, complete all as specified and as directed by Engineer-in-charge. |
| 30 | S&F in-repair ofSheet Metal Enclosure MCB DB SPN, 4 way 240 volt, with rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoingMCBs of any type, complete all as specified and as directed by Engineer-in-charge. |
| 31 | S&F in-repair ofSheet Metal Enclosure MCB DB SPN, 8 way 240 volt, with rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoingMCBs of any type, complete all as specified and as directed by Engineer-in-charge. |
| 32 | S&F in-repair ofSheet Metal Enclosure MCB DB SPN, 12 way 240 volt, with rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoingMCBs of any type, complete all as specified and as directed by Engineer-in-charge. |
| 33 | S&F in-repair ofSheet Metal Enclosure MCB DB TPN, 4 way 415 volt, with rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoingMCBs of any type, complete all as specified and as directed by Engineer-in-charge. |
| 34 | S&F in-repair of MCB Triple Pole & Neutral (TPN), \"C\" Curve, 40-100 Amps, 415 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge. |
| 35 | S&F in-repair of MCB Triple Pole & Neutral (TPN), \"C\" Curve, 16-32 Amps, 415 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge. |
| 36 | S&F in-repair of MCB Single Pole & Neutral (SPN), \"C\" Curve, 6-32 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge. |
| 37 | S&F in-repair of MCB Single Pole & Neutral (SPN), \"C\" Curve, 40-63 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge. |
| 38 | S&F in-repair of MCB Single Pole (SP), \"C\" Curve, 6-32 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge. |
| 39 | S&F in-repair of RCCB Four Pole (FP), 63 Amps, breaking capacity 30mA, 415 Volt for fixing on DB’s, 10 KA, 50 Hz, conforming to IS/IEC 61008-1, connecting up and testing, complete all as specified and as directed by Engineer-in-charge. |
| 40 | S&F in-repair of RCCB Four Pole (FP), 40 Amps, breaking capacity 30mA, 415 Volt for fixing on DB’s, 10 KA, 50 Hz, conforming to IS/IEC 61008-1, connecting up and testing, complete all as specified and as directed by Engineer-in-charge. |
| 41 | S&F in-repair of RCCB Double Pole (DP), 63 Amps, breaking capacity 30mA, 240 Volt for fixing on DB’s, 10 KA, 50 Hz, conforming to IS/IEC 61008-1, connecting up and testing, complete all as specified and as directed by Engineer-in-charge. |
| 42 | S&F in-repair of RCCB Double Pole (DP), 40 Amps, breaking capacity 30mA, 240 Volt for fixing on DB’s, 10 KA, 50 Hz, conforming to IS/IEC 61008-1, connecting up and testing, complete all as specified and as directed by Engineer-in-charge. |
| 43 | S&F in-repair of surface and wall mounted LED tube light fitting (separate batten and tube rod shall be measured as single unit) 1x 20W, (4 Feet) with aluminium housing, 6500K, 220-240 Volts, AC decorative regal type with and including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-charge. |
| 44 | S&F in-repair of surface and wall mounted LED light fitting mirror type 1x 10W, (2 Feet) with aluminium housing & integrated electronic driver, 6500K, 220-240 Volts, AC decorative box type with and including LED lamp connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-charge. |
| 45 | S&F in-repair of decorative wall light (indoor) of brushed nickel/ chromium finish with opal glass diffuser and 7Watt LED lamp, complete all as specified and as directed by Engineer-in-charge. (MAKE- Jaquar, Cat no.- DWL-CHR-MB14048T1E27) |
| 46 | S&F in-repair of goose neck wall lamp of brushed nickel/ chromium finish with 3Watt LED lamp, complete all as specified and as directed by Engineer-in-charge. (MAKE- Jaquar, Cat no.- DWL-CHR-LBED01R003XW) |
| 47 | S&F in-repair of 3 Watt LED foot lamp, complete all as specified and as directed by Engineer-in-charge. (MAKE- Jaquar, Cat no.- JSN-WHT-LFTLW1S003XW) |
| 48 | S&F in-repair of 10 watt capacity, B-22 base LED Bulb/ lamp (Warm white/ Cool White), complete all as specified and as directed by Engineer-in-charge. |
| 49 | S&F in-repair of slim square panel LED luminaire with frame 600 mm x 600 mm, white powder coated with CRCA housing, 35/36 watt, 220-240 V, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cables of suitable size, complete all as specified and as directed by Engineer-in-charge. |
| 50 | S&F in-repair Energy saving new generation environmental friendly long life versatile presure die cast aluminium housing IP 66 building security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired and lens embedded PC cover having Bottom opening seperate driver compartment and Impact resistance of IK08 with necessary mounting arrangements/ fixing bracket, complete all as specified and as directed by Engineer-in-charge. (NOTE- the cost of G.I. pipe bracket, bracket mounting clamp, bolts and nuts shall be paid separately) |
| 51 | M&L for earthing completewith galvanisedsteelearth plateelectrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade)and watering pipe 20 mm bore GI pipe(medium grade) andchamber and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg.50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and saltcomplete and earth leadconnected to earthing test point (up to main switches, DBs) including taking down existing damaged one, complete all as specified & testing on completion. NOTE:-(i)Item includes the cost of 1.5 mtr length GI pipe for protection for GI earth wire.(ii) item rates includes the cost of 7.5 mtr GI earth wire. |
| 52 | All as per Item No. 51 here-in-above, but for 32x6mm GI earth strip protected with 40mm dia GI pipe (medium grade), complete all as specified and as directed by Engineer-in-charge. |
| 53 | S&F in-repair of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor of, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of 2.5 Sqmm section, complete all as specified and as directed by engineer-in-charge. |
| 54 | All as per Item No. 53 here-in-above, but for cross-sectional area 4 Sqmm, complete all as specified and as directed by Engineer-in-charge. |
| 55 | All as per Item No. 53 here-in-above, but for cross-sectional area 6 Sqmm, complete all as specified and as directed by Engineer-in-charge. |
| 56 | All as per Item No. 53 here-in-above, but for cross-sectional area 10 Sqmm, complete all as specified and as directed by Engineer-in-charge. |
| 57 | All as per Item No. 53 here-in-above, but for cross-sectional area 16 Sqmm, complete all as specified and as directed by Engineer-in-charge. |
| 58 | S&F in-repair of multistranded round PVC insulated & PVC sheathed 1.5Sqmm 3 core cable with copper conductor upto 1100 Volts conforming to IS 694:2010 for connection of light fittings from junction box, complete all as specified and as directed by Engineer-in-charge. |
| 59 | M&L for disconnecting and taking down exhaust fan/ table fan/ wall fan/ pedestal fan of any sweep, sealing cable end and removing fan to store for Opening Stator, Cleaning of Parts, Greasing of Moveable Parts, re-winding the coil with Supper Enameled Copper Wire of same Gauge and same Weight with Insulation Paper, Varnishing and Heating, complete all as specified and as directed by Engineer-in-charge. |
| 60 | S&F in-repair of PVC exhaust fan/ wall fan/ pedestal fan blade of size upto 450mm sweep, complete all as specified and as directed by Engineer-in-charge. |
| 61 | M&L for disconnecting and taking down ceiling fan of 1200/1400 mm sweep, sealing cable end, dismantling blades and removing fan and blades to store for Opening Stator, Cleaning of Parts, replacement of Unserviceable Parts as ordered, Greasing of Moveable Parts, re-winding the coil and Re-assemblingthe ceiling fan after proper repair and applying two coats of synthetic enamel paint over a coat of red oxide primer by spraying including filling cavities with filler, after cleaning all dust and necessary surface preparation including hanging the ceiling fan in original position and connecting up including provision of cable from ceiling rose or connector to fan (as/if required), complete all as specified and as directed by Engineer-in-charge. NOTE:- Spare-parts and cost of re-winding shall be measured and paid separately under relevent item. |
| 62 | M&L for re-winding the coil of ceiling fan 1200/1400 mm sweep with Supper Enameled Copper Wire of same Gauge and same Weight with Insulation Paper, Varnishing and Heating, complete all as specified and as directed by Engineer-in-charge. |
| 63 | Supply only Ball Bearing No. 6201/6202/6203/6204 as approved suitable for Ceiling Fan of 1200/1400mm Sweep, complete all as specified and as directed by Engineer-in-charge. MAKE- SKF/ NBC/ TATA |
| 64 | S&F in-repair of Thermostat/Thermal cutoff suitable for Water Storage Geyser of range 0-90ºC as required, conforming to IS (Make as approved) complete all as specified and as directed. |
| 65 | S&F in-repair of Electro-plated Heating Element of any shape (as per site requirement & as approved), suitable for Electric Geyser of 1.5/2.0 KW capacity, 240 Volts, complete all as specified and as directed. MAKE : BAJAJ/RECOLD/HAVELLS/USHA |
| 66 | S&F in-repair of Stainless steel braided flexible connection pipe of 450mm long (02 Nos) with brass connector series for both inlet and outlet of Geyser, complete all as specified ans as directed.MAKE:- PRAYAG/POLYTUF/ AS EXISTING |
| 67 | S&F in repair Plug Top of 3Pin, 15/16 Amps capacity with indicator, complete all as specified and as directed.MAKE:- ANCHOR/L&T/HAVELLS |
| 68 | S&F in-repair of Energy saving new generation environmental friendly long life versatile presure die cast aluminium housing and heat resistant, IP 66 street light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35/36 watts with pre wired and lens embedded PC cover having Top opening seperate driver compartment, with impact and corrosion resistant (IK-08) including thermal management in multiple optics and necessary mounting arrangements/ fixing bracket, complete all as specified and as directed by Engineer-in-charge. (NOTE- the cost of G.I. pipe bracket, bracket mounting clamp, bolts and nuts shall be paid separately) |
| 69 | All as per Item No. 68 here-in-above, but for 60 Watt LED street light, complete all as specified and as directed by Engineer-in-charge. |
| 70 | S&F in-repair of Energy saving new generation environmental friendly long life versatile presure die cast aluminium housing and heat resistant, IP 66 Flood light fitting luminaire with high power LEDs as light source and electronic driver of capacity 70 watts with pre wired and lens embedded PC cover having Top opening seperate driver compartment, with impact and corrosion resistant (IK-08) including thermal management in multiple optics and necessary mounting arrangements/ fixing bracket, complete all as specified and as directed by Engineer-in-charge.(NOTE- the cost of G.I. pipe bracket, bracket mounting clamp, bolts and nuts shall be paid separately) |
| 71 | All as per Item No. 70 here-in-above, but for 120 Watt LED flood light, complete all as specified and as directed by Engineer-in-charge. |
| 72 | All as per Item No. 70 here-in-above, but for 200 Watt LED flood light, complete all as specified and as directed by Engineer-in-charge. |
| 73 | S&F in-repair of IP-65 rated robust designed 8Watt LED bollard garden Light Fitting with black ABS Plastic Spigot, Spun Aluminium Canopy with Diffuser duly pre-wired, including embedding on 150x150x200mm PCC Block 1:3:6 (20mm Graded Aggregate), complete as all specified and as directed by Engineer-in-charge. |
| 74 | S&F in-repair of post top lantern LED type 40 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source complete with fixing accessories, complete as all specified and as directed by Engineer-in-charge. |
| 75 | S&F in-repair of IP-65, IK-08 rated opal moon shaped garden light 300mm dia and 350mm in height in soothing moon finish made up of high grade unbreakable Polycarbonate material, suitable for upto 20W LED lamp (retrofit) B22 base with fixing accessories, complete as all specified and directed by Engineer-in-charge. |
| 76 | S&F in-repair of Gate light small with LED lamp of 20 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source complete with fixing accessories, complete as all specified and as directed by Engineer-in-charge. |
| 77 | S&F in-repair of Gate light big with LED lamp of 40 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source complete with fixing accessories, complete as all specified and as directed by Engineer-in-charge. |
| 78 | S&F in-repair of 9Watt LED single dome aviation/ obstacle light red in colour to be fixed with necessary electrical connections, complete all as specified and as directed by Engineer-in-charge. |
| 79 | S&F in-repair of Pole Box/Junction Box of size 210 X 155 X 92mm (LxBxH) made out of Polycarbonate material totally enclosed, dust and vermin proof, door pasted with rubber gasket, water tight IP 66/67 protection single leaf shutter in front having proper locking arrangements, including provision of suitable connector for single phase connections loop in and out 10 to 16 Sqmm 4.0 Core aluminium armoured cable branch out 1.5 Sqmm single core PVC insulated copper cable and MCB SP 06 amps- 01 No and mounted on security light pole with suitable clamps (GI Flat iron of 25x3mm), nuts, bolts, complete all as specified and directed by Engineer-in-charge. |
| 80 | M&L for preparing old painted surfaces by scraping and removing old paints, rust, etc. from Steel Tubular Poles (above the Planting Depth and PCC Copings of 9.0 Metre length Pole) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying one Coat of synthetic enamel paint in alternate Yellow & Black Strips (5 Nos. Strip of 300 mm wide each) and remaining portion of Pole and Cross Arms, Cable Protection Pipe, Brackets, etc. treated with One Coat of Aluminium Paint, including writing of pole numbers with black synthetic enamel paint,complete all as specified and as directed by engineer-in-charge. |
| 81 | S&F in-repair of bracket suitable for LED Street light fitting/ house service bracket made out of 32mm bore (Dia) light grade GI pipe of 1.2m long, bend to required shape, including necesary clamps (Mild Steel Flat iron of 32x6mm) forfixing of building security/ street light fitting as per existing, complete all as specified and as directed by Engineer-in- Charge.(NOTE- MS fixing clamps and nut-bolt shall be painted with two coats of aluminium paint) |