| 1 | Material and labour for excavating in trenches not exc 1.50 mtr wide and not exc 1.50 mtr in depth for taking out/laying of under ground cable, pole or stay and getting out in soft/loose soil, complete all as specified and as directed. |
| 2 | Returning filling in soft/loose soil, including, spreading, levelling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed. NOTE : The top of filled trench shall be made proud by using the excavated soil to cater for subsequent settlement of soil. |
| 3 | Removing excavated materials (soils) not exc 50.00mtr and depositing where directed at a level not exc 1.50 mtr above the starting point in soil, complete all as specified and as directed. |
| 4 | Supply and filling for dry sand in cable protection trenches before and after the cables are laid, for sand cushioning to cables complete all as specified and directed. NOTE : thickness after punning of sand shall be (minimum as specified in SSR) measured and paid in this item. |
| 5 | Material and labour for brick protection for UG XLPE cable with burnt clay old size sub class \"B\" bricks laid dry and flat abutting each other with gaps between adjacent brick not more than 10mm and width equal to length of brick in trenches across the cable complete all as directed by Engineer-In-Charge.Make: Best quality locally available which is duly approved by GE. |
| 6 | Supply, lay and fix 20 mm bore galvanized iron tubing (light grade) including all fittings and laid in trenches, walls and ceilings or laid in floors complete all as specified and directed.Note: Excavation shall be measured and paid in separate item |
| 7 | Supply and laying, connecting, testing, commissioning LT UG cable XLPE Insulated,armoured,electric powercables (heavy duty) 1100 Volts grade conforming to IS 7098 withaluminium conductor multi-strand of cross-sectional area 25 Sqmm 3.50 Core laid in trenches / ducts/ inside protection pipe including cable glands, lugs and suitable size of MS saddle clips etc. all as directed by Engr-In-Charge.Note:-(a) Excavation, sand cushioning, bricks shall be measured and paid separately |
| 8 | Supply and laying, connecting, testing, commissioning LT UG cable XLPE Insulated,armoured,electric powercables (heavy duty) 1100 Volts grade conforming to IS 7098 withaluminium conductor multi-strand of cross-sectional area 10 Sqmm 4 Core laid in trenches / ducts/ inside protection pipe including cable glands, lugs and suitable size of MS saddle clips etc.all as directed by Engr-In-Charge.Note:-(a) Excavation, sand cushioning, bricks shall be measured and paid separately |
| 9 | Supply and laying, connecting, testing, commissioning LT UG cable XLPE Insulated,armoured,electric powercables (heavy duty) 1100 Volts grade conforming to IS 7098 withaluminium conductor multi-strand of cross-sectional area 10 Sqmm 2 Core laid in trenches / ducts/ inside protection pipe including cable glands, lugs and suitable size of MS saddle clips etc.all as directed by Engr-In-Charge.Note:-(a) Excavation, sand cushioning, bricks shall be measured and paid separately |
| 10 | Supply and fix LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specifed and directed.Note:- (a) LM-80 certificate from NABL accredited Lab shall be submitted for LED light fittings.(b) Warranty certificate shall be submitted for LED light fitting as per standered format for minium 50000 Hrs.(c) LED light fitting and drivers shall be of same make. |
| 11 | Material and labour for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 metres long) complete all as specified. |
| 12 | Supply and fixing GI bracket for street light made out of 40 mm dia GI pipe light grade 1.5 mtr length bend in shape as required complete with 2 nos of MS flat iron clamp of size 50 mm x 6 mm, nuts and bolts etc complete as specified and as directed |
| 13 | Material and labour for weather proof SMC junction box with IP 66 protection (halogen free and weather proof) for outdoor installations of size 295 mm x 195 mm x 100 mm with terminals one mounting bracket and making provision of an MCB SPN including internal connection, gland for cable, FI clamp of size 20 mm x 3 mm, nuts, bolts, washers, provision of connectors for connection of cables etc complete all as specified or directed. |
| 14 | Material and labour for plain cement concrete 1:3:6 type C1 using 20 mm graded crushed stone aggreagates as in coping of poles complete all as specified.Note:-Formwork shall be measured and paid including this item. |
| 15 | Material and labour for plain cement concrete 1:4:8 type D2 using 40 mm graded crushed stone aggreagates as in PCC/ Road Cutting/ installation area and foundation of poles etc. complete all as specified.Note:-If formwork required, the formwork shall be measured and paid including this item. |
| 16 | Supply and fix MCB SP 240 volts, 50 Hz capacity 6-32 Amps \"B\" curve all as specified. |
| 17 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 3 core 4 sq. mm nominal cross section in service connections complete all as specified |
| 18 | Supply and fixing Astronomical Street Light time Switch 24 Hrs dial (Astro Mini) 110-240V AC 1 phase-2W, 240 V AC 1 phase, Base/ DIN Mounting in existing panel all as directed by Engineer-In-Charge. |
| 19 | Supply and fix 3 pole power contractors with AC 3 rating confirming to IS/IEC 60947-4-1 & IEC 60947-4-1 for 70 Amps current rating having 2 NO+ 2 NC auxiliary contractors size Fr 3. |
| 20 | Material and labour for horizontal boring for 20 mm bore GI pipe under road/ pavement/ hard standing at 0.6 mtr to 1.50 mtr depth from top of road level and insert 20 mm medium GI pipe for laying XLPE UG cable with all necessary fittings and without any damage of road/ pavement/ hard standing surface complete all as specified and directed.Note: (a) Necessary Earthwork shal be measured and paid including this item.(b) GI pipe shall be measured and paid including this item. |
| 21 | Supply, installation , testing and commissioning of maintenance free Chemical Earthing system with 80 mm dia and 3 meter length Copper bonded pipe Earthingwith 250 micronpipe filled with molecularly bonded crystalline conductive material in order to prevent the pipe from inner corrosion .The inner Copper strip must be of size 20 mmX 3 mm . 6-8 inches dia bore must be made up to 10.5 feet depth and the plateshould be placed on the centre of the Earth pit and the pit surroundings must be filled with conductolyte compound at least 75 Kg. The Compound should be filled with necessary processing as advised by company representative. In case where soil resistivity is high additional loops may be made by adding more number of electrodes to achieve the required result and the same shall be paid inclusive to the items. The connection must be well made with hot dip galvanized 80-100 micron Earth Strip as per required sizes for various devices as specified. The strip at ground level should be covered with heat shrink PVC Sleeve and the wiring must be insulated bey providing DMC insulatorand GI Saddled. The joining of Strips should have atleast two nut bolts and the same should be welded properly so that free space exsist on joints. The earth pits should be covered with pit cover of size 1.5 ft diaX 1.5ft length and must be mason worked with brick and cement to hold the pit cover firmly. Each connecting pits for devices should have earth bar of size 300X 300 made of Copper 6 Terminal box type which should have insulation. Incase where proper Clayaee soil is not available the pit of dia 1.5 mtrs must be dug. Before earthing installation of electrodes necessary processing must made for soil treatment as guided by Engr-in-Charge. 01 Each Set of Earthing Include05 Nos. Copper Bonded pipe grid. |
| 22 | Note for BOQ Sl No. 21 : (i) The Ohmic value should be less then 1 ohm.(ii) If the necessary earthing value is not provided by the contractor then the contractor shall be arranged further grids to achieve necessary value. No extra payment shall be made for additional grids for testing of soil. (iii) If the necessary earthing value is not provided by the contractor then the contractor shall be arranged necessary quantum of soil for required permiabilty to achieve necessary value. No extra payment shall be made for additional soil if required. (iv) To achieve the ohmic value the contractor shall be filled extra quantum of BFC compound (Conductolyte) and no extra cost shall be paid to the contractor. |
| 23 | Material and labour for earthing with copper earth plate electrode60 cm X 60 cm X 3.15 mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 20 mm x 3 mm thick copper strip protected by 40 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the copper plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover10mm thick hinged to CI frame and 8mm MS rod for handleincluding painting with synthetic enamel paint of approved colour and put number marked with GI plate above 45 cm from ground level as per colour code in AF station, necessary excavation and earth wok in soft/loose soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I including taking out old earthing all as specified.Note: (i) The cost of copper strip and GI protection pipe upto 7.5 mtr is deemed to be included in the quoted rate.(ii) The cost of excavation, earth work are deemed to be included in the quoted rate. |
| 24 | Material and labour fopr Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 mm x 3 mm copper strip using porcelain clit/post insulator including brazing if required complete all as specified. |
| 25 | Material and labour for cable junction box with IP 66 protection (halogen free and weather proof) for outdoor installations of size 98 mm x 98 mm x 61 mm with terminals for covering Gun Metal used for earthing all as specified or directed. |
| 26 | Material and labour test point terminal block made of gun metal or phosphorus bronze size 75 mm x 75 mm x 25 mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw complete all as specified. |