| 1 | M & L for point wiring with copper conductor cable multistrand, FRLSH PVC sheathed 1.5 Sqmm size (two run with colour code RYB ) for one light point , fan point ,exhaust fan point ,orbell point controlled by one switch including one run of 1.5 Sqmm (as continous earth wire Green) multistrand PVC concealedconduit of approved size and quality ISI marked , including all other requiredaccessories as specified in preamable 1 (a) to (q) of section 19 of SSR Part -II under heading\"point wiring\" fixedon wall /ceiling including sunk cast iron terminal boxes grouting/ flushing on wall for mounting fittings like switch, socket etc covered with 3.00 mm thick plastic laminated sheet top cover of brick masonary/stone masnoary wall complete includingcutting, chasing, pinning and making good the disturbed surface by using cementmortar 1:3 complete all as specified and directed by Engr-in-charge. Make of wire /cable -Havells/Anchor/Finolex, (Note:- the rate for concealedtype point wiring shall deemed to include the cost of cutting, chasing in wall by using electric cutter and making good the disturbed surface of wall by providing cement plaster and matching the surface by white wash /colour wash all as per existing finishes complete). |
| 2 | All as per Srl item No 1 here in before butfor one 5 amps socket out let on same board. |
| 3 | All as per Srl item No 1 here in before but for one 5 amps socket out leton independent board. |
| 4 | All as per item No 1 above but for power point 3 pin switch socket 16 Amp with PVC insulatedcopper conductor cable multistrand unsheathed 2.5 Sqmm (two run with colour code RYB) on independent board including one run of 2.5 Sqmm multistrand PVC sheathed copper conductor cable for earth continuity in concealed PVC conduit of appropriate size and best quality ISI marked ,including all other required accessories as specifiedin preamble1(a) to(q) of section -19 of SSR Part- II under heading \"Point wiring\" fixedon wall including sunk cast iron or PVC terminal boxes for mounting fittings like switch ,socket etc covered with 3.00 mm thick plastic laminated sheet top cover all as specifiedand as directed . |
| 5 | Supply and fix modular switch 1 module 6 amp one way ISI marked. |
| 6 | Supply and fix modular switch 1 module 16 amp one way |
| 7 | Supply and fix modular socket 2 moduleuniversal type 5/6 amp one way |
| 8 | Supply and fix modular socket 2 moduleuniversal type 15/16 amp one way |
| 9 | Supply & fix ceiling rose 65x50 mm two to three terminals complete all as specified. |
| 10 | S& F Supply and fixing round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as directed. |
| 11 | S& F Wall mounted LED integrated batten fitting T5, 9/10 W LED, 2 feet PVC extruded. Havells cat part no LUMILINEBS9WLED865SPCWH or equivalent make as specified in list of make here-in-after. |
| 12 | S & F LED building securitylight fitting with suitable size bracket/angle to fit securitylight of 35W IP 66 protection LED make Bajaj/Havells etc complete all as specified and directed. |
| 13 | Supply & fixing Sheet metal enclosurefor DB,s,double door (when MCB,s to be used ) single pole & neutral 4 way with 200ampsrated bus bar 240 volts with fixing arrangements complete all as specified and directed by Engineer-in-charge. |
| 14 | Supply & fixing MCB single pole and neutral 6 to 40Amps,240 volts complete all as specifiedand directed. |
| 15 | Supply & fixing MCB single pole 6 to 32Amps,240 volts complete all as specifiedand directed. |
| 16 | M&L for sub main/Main circuit wiring with 4 sqmm copper conductor cable multistrand, FRLSH PVC sheathed two run (as phase and neutral )and run 4 sqmm multistrand PVC sheathed copper conductor cable for earth continuity in drawn in one pvc concealed wiring complete all as specified and directed by Engr-in-charge .(Note:-the rate for concealed type point wiring shall deemed to include the cost of cutting ,chasing in wall by electric cutter and making good the disturbed surface of wall by providing cement plasterandmatching the surface by white wash /colour wash all as per existing finishes complete). |
| 17 | Material and labour for earthing complete with galvanised steel earth plate electrode 60cmx60cm x 6mm thick burried directly in ground any type of soil including rock soil also (earth pit not less than 2.25 mtr below ground level ) with top edge of plate not less than 1.5mtr below normal ground level connected to galvanised earth lead wire4mm dia as earthing lead by means of bolts ,nuts ,check nuts,as earth lead complete including 40mm bore dia protection pipe GI light grade upto 7.5mtr length ,watering pipe 15mm bore dia GI light grade 1.70m length ,charcoal &salt filling ,necessary earth work in any type of soil including rocky soil also,concrete pit ,funnel removal of surplus soil upto 50m distance all as per electrical plate No.3 of SSR part -I and connected to earthing test point ,main board including testing on completion all as sepcified and as directed by Engr-in- charge. |
| 18 | Supply and fix electric water heater, storage type steel body with SS inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. |
| 19 | Supply and fix exhaustfan, steel body AC single phase, 230V of size 300mm sweep with, blades, and frame and louvers shutter complete all as specified and directed. |
| 20 | Supply and laying in trench/fixed on wall/floors galvanized steel water tubing medium grade ISI marked of the size 25mm boe incl all fittings such asbends elbows, tees, short pieces, connectors, back nuts, diminishingpieces, caps and pigs, unions etc. complete all as directed . Make Jindal/Tata/Prakash Surya/Zenith.Note :- Necessary excavation and earth work shall be measured and paid separately |
| 21 | S&F gunmetal globe or gate valve with iron wheel head screwed bolt ends for iron pipe of the size 25mm boe complete all as specified and directed by Engineer-in-charge. Make : Leader/Zoloto |
| 22 | Excavation in trenches in hard/dense soil n. exc 1.5mtr wide and n. exc 1.5mtr depth for LT cable /GI tubing and getting out in Hard/dense soil all as specified. |
| 23 | M&L for returning, filling in including sperading, leveling watering and well ramming in layers n. exc 25 cm thick each layers in soil all as specified and directed. |
| 24 | M&L for removal of surplus soil to a distance not exceeding 50 mtr and deposting where directed and at a level not exceeding 1.5 mtr above the starting point all as specified and directed by Engr-in-Charge. |
| 25 | M&L for Cutting the existing CI/GI pipe 40/50/65/80/100/150 mm bore or screwing existing CI/GI pipe for addn or altn as required on site including GI fiitings complete all as directed. Note: Necessary earth work shall be measured and paid separately. |
| 26 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth forfor foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified |
| 27 | M/L Plain Cement Concrete Type C2, 1:3:6 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete complete all as specified. |
| 28 | Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified. |
| 29 | Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups,spacers and binders complete all as specified. |
| 30 | M&L for use and waste of formwork for foundation, footing, Plinth beams etc., for rough finished flat surfaces complete all as specified. |
| 31 | RCC design M-25 (using 20mm graded stone aggregate) Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified. |
| 32 | M&L for use and waste of formwork for sides of columnsfor rough finished square and retangular surfaces all as specified. |
| 33 | RCC design M-25(using 20mm graded stone aggregate) as in Columns, pillars, piers, posts and struts complete all as specified. |
| 34 | M&L for use and waste of formwork to sides and soffits of floor or roof beam, beam hauchings, girder, bressum-mers, lintels, cantilivers, shelves incl supports, overhangs, etc. Also splay between floors and beams, etc. for rough finished flat surfaces complete all as specified. |
| 35 | RCC design M-25(using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed |
| 36 | M&L for PCC type C-2, 1:3:6 (using 40 mm graded crushed stone aggregate) as in surface channels and drains complete all as specified and directed. |
| 37 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc. complete all as specified and directed. |
| 38 | M&L Brick work with old size burnt fly ash bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 all as specified and directed by Engineer - in - Charge . |
| 39 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4, finished even and smooth without using extra cement complete all as specified and as directed. |
| 40 | M&L for preparation of newly plastered surface of wall and applying two coat of 100 % acrylic smooth emulsion exterior grade with silicon additives and anti-fengal poperties (Apex Ultima Suprema) over one coat of smartcare waterproof primer (Damp prime suprema) on walls and chajja with 10 % of dilution of water over water proof cement based putty @ 2 kg (undiluted) per Sqm of average thickness 2mm over silicon additives and sanding the surface for removal of loose particles, Tint and shed of the building as directed by Engr-in Charge. |
| 41 | M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and as directed |
| 42 | M&L for preparation of newly plastered surfaces of walls and applying two coats of OBD over a coat ,including preparation over a coat of primer complete all as specified |
| 43 | M&L forHardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15cmthick, watered androlled/rammed to a true surface complete all as specified and as directed |
| 44 | M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection 75 mm thick incl finished even & smooth without using extra cement complete all as specified. |
| 45 | Cement concrete 1:3:6 type B1 ( using 40 mm crushed stone agg.) as in floor 100 mm thick as sub base finished even and smooth with out using extra cement complete all as specified and as directed |
| 46 | Mat finish, premium quality, joint free (edge cut), coloured/ printed Non -Skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors etc. set and jointed in neat cement slurry and including 15mm thick bedding layer in cement mortar (1:4) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed. |
| 47 | M & L Coloured glazed ceramic tiles in vertical surface of size 450x350x7 mm thick as in vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match,and including 15mm thick screed bed or bedding layer of CM (1:4)complete all as specified and as directed |
| 48 | M&L for 20 mm thick Granite (of any type) work in steps, jambs, pillars, window-cills, cooking platforms and laid in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite&cutting , rounding of edges and mirror polishing, of granitecomplete all as secified and as directed. |
| 49 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. and similar work conforming to Fe 410W Gde E250 quality B; complete all as specified and as directed. |
| 50 | M&L for preparation new steel surfaces, of any description, over 10cm width or girth and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engr-in Charge. |
| 51 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete as specified and as directed. |
| 52 | S&F Aluminium anodized snap grid (powder coated) frame work of grid size 605x605mm including hangers 6mm dia GI (upto 1200mm long) for false ceiling including notching and preparing holes, including aluminium cleat/corner pieces and GI 4mm dia suspenders with utterfly clips, wall angle of size 24 x 24mm, main runner (teee) of size 24 x 38mm, cross tee of size 24 x 28mm, (No of suspenders shall be decided by the AGE (I)as per actual size requirement)Perforated particleboard/tiles of 12mm thick for insula-tion and accoustic purposes, as in ceilings flat or sloping 60x60 cm in size complete all as specified. |
| 53 | S&F powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified (minimum thickness of powder coating 50 micron). |
| 54 | S&F powder coated anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified (minimum thickness of powder coating 50 micron). |
| 55 | S&F brass mortice lock 2 level , vertical type size 100 mm fixed in alu doors complete all as specified |
| 56 | S&F aluminium Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified |
| 57 | S&F powder coated anodised aluminium window and ventilator shutters, fixed type with out sash bars aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos, Tower Bolt 2in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified (minimum thickness of powder coating 50 micron). |
| 58 | Supply & fixing onlyfrosted sheet glass 4.8mm thick, selected quality, in squares exec 0.5 sqm each panecomplete all as specified |
| 59 | S & F galvanised stinless steel wire cloth, 0.51 mm to 0.56 mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks, or galvanised wire staples,fixed in repairsall as specified. |
| 60 | Excavating in post holes (or similar holes) each n.exc 0.5 Cum , getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layer n.exc 25 cm, watering, and removing surplus soil to a distance n.exc 50 mtr and making good surfaces in soft/loose soil complete all as specified and directed by Engineer-in-Charge. |
| 61 | S&F Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. and similar work conforming to Fe 410W Gde E250 quality B; complete all as specified and as directed. |
| 62 | S & F Rotational moulded polyethylene water storage tanks 1000 Ltr (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified. |
| 63 | S&F 20mm PTMT , high pressure, with polytheene float and flynut complete, screwed for iron pipe orr brass ferrule and fixed in repairs |
| 64 | S & F 20 mm bore galvanized steel tubes, medium grade with all fittings complete fixed to walls and ceilings or laid in floors as specified. |
| 65 | S & F 15 mm bore galvanized steel tubes, medium grade with all fittings complete fixed to walls and ceilings or laid in floors as specified. |
| 66 | Brass CP mixer for mixing hot & cold water screwed down for iron pipe (Two in one wall mixer/ central hole basin mixerand fixedall as directed by Engr-in- charge. |
| 67 | S&FCP Stop valve/Angle valve 15mm bore cast copper alloy with crutch and butter fly handle screwed down high pressure,screwed both ends forpipe or for unionsall as specified. |
| 68 | S&FCP Bib tap, 15mm dia, cast copper alloywith crutch or butter fly handle screwed down, screwed for iron pipe or brass ferrule and fixed in repair all as specifiedscrewed for iron pipe or brass ferrule complete all as specified |
| 69 | Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 70 | S& Ffor brass chromium plated shower rose 125 mm size with swivel joint including fixing to 15 mm dia steel pipe or union. |
| 71 | Supply & fixing PVC connection both sides brass unions internal for size of 15mm size with PTMT nuts of length 450mm longcomplete all as specified & directed by Engineer-in-charge. |
| 72 | S&F one/single piece Vitreous china water closest white colour of size 750 x 665 x 360 mm including an inbuiltsyphonic action type flusing cistern 10 liter capacity with seat cover and PVC pipe upto finish floor level to connect flush pipe, making good all the disturbed surface of floor to matcing the adjoining complete all as specified and directed by Engr-in-Charge. Make Cap part No. 1013122 of Cera or equivalent make as specified in list of make here-in-after. |
| 73 | S & F in repair Vitreous China wash hand basin, white, flat back, size 550x400mm excluding taps, waste coupling, chain and plug and porcelain stopper but including brackets & waste pipe complete all as specified. |
| 74 | S & Fvitreous china urinal ,bowl type (back or corner wall type),flat back size of 465x355x265mm complete including providing and fixing plugs,bedding urinal agianst wall in cement mortar 1:2,securing urinal to plugs with and including 60mm long brass screws,pointing around urinal back in cement ,fixing automatic flusing cistern with brackets,bottol trap ,water spreaderand union for discharge pipe complete all as specified and directed by Engineer - in – Charge. |
| 75 | S & F urinal Spreader of PTMT any colour for fixing with 15 mm dia pipe ( Minimum weight 60 gms) complete all as specified. |
| 76 | S & F Toilet paper holder, with flat recessed type stainles steel complete all as specified and directed. |
| 77 | Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including making connection and fixed in position complete in all respect as specified. |
| 78 | S & F looking mirror of size 600 mm x1000 mm bevelled edge mirror of selected quality 5 mmglass,fixed to wallwith stainless steel bracketcomplete all as specified and directed by Engineer-in-Charge. |
| 79 | S&F brass chromium plated towel rail of size 60cm fixedwith chromium plated brass screws and plastic cleats complete all as specified & directed by Engineer-in-Charge. |
| 80 | S & Fbrass Bottol trap with chromium finishfor Wash Basin/ urinal complete all as specified and directed |
| 81 | S&F, 75mm PVC (SWR) pipe singal shocket ,waste and vent pipes, in any length with rubber ring joints,laid in fixed to walls & in trenhescomplete all as specified & directed by Engineer-in-Charge. |
| 82 | S&F, 110 mm PVC (SWR) pipe singal shocket , waste and vent pipes, in any length with rubber ring joints,laid in fixed to walls & trenhescomplete all as specified & directed by Engineer-in-Charge. |
| 83 | S&F, 110mm PVC (SWR)Bends (any radius), complete all as specified |
| 84 | S&F, 75mm PVC (SWR)Bends (any radius), complete all as specified |
| 85 | S&FPVC (SWR) 75 mm dia floor trap, plain with grating including jointing with solvent cement to connect waste pipe and fixed with PCC 1:2:4 complete all as specified and directed by Engineer - in – Charge. |
| 86 | Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting outin soft / loose soil complete all as specified and as directed. |
| 87 | M&L PCC 1:4:8 type D-2 (40MM graded aggregate as in sub base 75mm thick complete all as specified. |
| 88 | M&L for chequered cement concrete colouredtiles, homogeneous texture glossy finished, chemically coated machine pressed 30 cm x 30cm x 25mm thick set, jointed and pointed in near cement slurry in floor with gray cement and pigment and including 20 mm thick cement screed in cement mortar 1:4, including demolition of stone slabs or tiles of any description or thickness in floors, aaprons etc laid and bedded in cement morta complete all as specified and directed by Engr-in Charge. Shade/Colour of tile shall be approved by the AGE(I). |
| 89 | Providing precast cement concrete 1:2:4, type B-1 as in kerb stone, fair faces, including chamfers, weathering’s, throat-ing etc. and setting in CM 1:4, complete all as specified. |
| 90 | M & L on site LLDPE septik tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation , vent shaft, connection etc, complete for 05 user for conventional |
| 91 | Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.20M dia X 3.00 M effective depth. Drg No : CEPZ/C-TD/013/13 |