Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Development of Infrastructure at Shirui Heritage Village and Bakshi Ground at Ukhrul District |
| 2 | CIVIL WORKS |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 4 | All kinds of soil |
| 5 | Supplying and filling in plinth with sandy soil under floors including, watering,ramming consolidating and dressing complete. |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 7 | 1:3:6 ( 1 Cement: 3coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 8 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 9 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 10 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 13 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 14 | Suspended floors, roofs, landings, balconies and access platform. |
| 15 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 16 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 17 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 18 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 19 | Brick work with Ist class common burnt clay F.P.S.(non modular) bricks in superstructure above plinth level upto floor V level in all shapes and sizes in : |
| 20 | Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 21 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 22 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 23 | 15 mm cement plaster on rough side of single or half brick wall of mix:- |
| 24 | 1:4 (1 cement: 4 fine sand) |
| 25 | 20 mm cement plaster of mix |
| 26 | 1:4 (1 cement: 4 fine sand) |
| 27 | 12 mm cement plaster of mix : |
| 28 | 1:4 (1 cement: 4 fine sand) |
| 29 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws. |
| 30 | Local best quality Teak wood |
| 31 | 35 mm thick |
| 32 | EXTERIOR PAINTS |
| 33 | Finishing walls with textured exterior paint of required shade : |
| 34 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 35 | INTERIOR PAINTS |
| 36 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications : |
| 37 | Two or more coats applied @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @0.75 ltr/10 sqm. |
| 38 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to preparethe surface even and smooth complete. |
| 39 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 40 | Water thinnable cement primer |
| 41 | STEEL REINFORCEMENT |
| 42 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level & above plinth level. |
| 43 | Thermo-Mechanically Treated bars |
| 44 | Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. |
| 45 | Hot finished welded type tubes |
| 46 | Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishng to |
| 47 | a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers,cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 48 | 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part I, |
| 49 | Polishing on wood work with ready made wax polish of approved brand and manufacture : |
| 50 | New work |
| 51 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 52 | 0.63 mm thick with zinc coating not less than 275gm/sqm |
| 53 | Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. |
| 54 | 0.63mm thick with zinc coating not less than 275gm/m2 |
| 55 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement [email protected] kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 56 | Double charge vitrified tile polished finish of size |
| 57 | Size of Tile 600 x 600 mm |
| 58 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 59 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters ,window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 60 | Granite of any colour and shade |
| 61 | Area of slab over 0.50 sqm. |
| 62 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 63 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 64 | 300x16 mm |
| 65 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 66 | 300x10 mm |
| 67 | Providing and fixing aluminium handles, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 68 | 125 mm |
| 69 | Providing and fixing IS : 12817 marked stainless steel butt hinges with steelscrews etc. complete : |
| 70 | 125x64x1.90 mm |
| 71 | Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : |
| 72 | Local best quality Teak wood |
| 73 | Providing and fixing fibre cement high impact polypropylene reinforced roofing accessories in all colour with polymer coated J or L hooks,bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete: |
| 74 | Barge boards |
| 75 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (whitepowder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mmsize for fixing frame to finished wall and ecessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at allcorners, including drilling of holes for fixing ardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes,wire mesh and silicon sealent shall be paid separately). Variation inprofile dimension in higher side shall be accepted but no extra paymenton this account shall be made. |
| 76 | Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. |
| 77 | Three track three panels sliding window made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) |
| 78 | INTERNAL ELECTRICAL WORKS |
| 79 | Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 80 | Group A |
| 81 | Group B |
| 82 | Group C |
| 83 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loopearthing as required. |
| 84 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 85 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 86 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 87 | 25 mm |
| 88 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 89 | 5/6 A switch |
| 90 | 3 pin 5/6 A socket outlet |
| 91 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 92 | 12 Module (200mmX150mm) |
| 93 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required |
| 94 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 95 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 96 | 6 way , Double door |
| 97 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 98 | Single pole |
| 99 | Double pole |
| 100 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 101 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 102 | Upto 35 sq. mm |
| 103 | LED Down lighter (COB Type) (System lumenefficacy ≥120 lm/Watt ) |
| 104 | Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 105 | Powdercoateddiecast/Extruded aluminium Body including trim with Aluminium Reflector |
| 106 | 12 -15 watt |
| 107 | 22 watt |
| 108 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value, (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 109 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 110 | NON SOR ITEM |
| 111 | Supplyof following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armoured (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . |
| 112 | 10 00 Sq.mm 3 Core U.G.armoured cable |
| 113 | A. 2. Estimate of Visitor Information Centre |
| 114 | CIVIL WORKS |
| 115 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 116 | All kinds of soil |
| 117 | Supplying and filling in plinth with sandy soil under floors including, watering,ramming consolidating and dressing complete. |
| 118 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 119 | 1:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 120 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 121 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 122 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 123 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 124 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 125 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 126 | Suspended floors, roofs, landings, balconies and access platform. |
| 127 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 128 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 129 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 130 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 131 | Brick work with Ist class common burnt clay F.P.S.(non modular) bricks in superstructure above plinth level upto floor V level in all shapes and sizes in : |
| 132 | Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 133 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in |
| 134 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 135 | 15 mm cement plaster on rough side of single or half brick wall of mix:- |
| 136 | 1:4 (1 cement: 4 fine sand) |
| 137 | 20 mm cement plaster of mix |
| 138 | 1:4 (1 cement: 4 fine sand) |
| 139 | 12 mm cement plaster of mix : |
| 140 | 1:4 (1 cement: 4 fine sand) |
| 141 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws. |
| 142 | Local best quality Teak wood |
| 143 | 35 mm thick |
| 144 | EXTERIOR PAINTS |
| 145 | Finishing walls with textured exterior paint of required shade : |
| 146 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 147 | INTERIOR PAINTS |
| 148 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications : |
| 149 | Two or more coats applied @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @0.75 ltr/10 sqm. |
| 150 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to preparethe surface even and smooth complete. |
| 151 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 152 | Water thinnable cement primer |
| 153 | STEEL REINFORCEMENT |
| 154 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level & above plinth level. |
| 155 | Thermo-Mechanically Treated bars |
| 156 | Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. |
| 157 | Hot finished welded type tubes |
| 158 | Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishng to |
| 159 | a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers,cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 160 | 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part I, |
| 161 | Polishing on wood work with ready made wax polish of approved brand and manufacture : |
| 162 | New work |
| 163 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 164 | 0.63 mm thick with zinc coating not less than 275gm/sqm |
| 165 | Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. |
| 166 | 0.63mm thick with zinc coating not less than 275gm/m2 |
| 167 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement [email protected] kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 168 | Double charge vitrified tile polished finish of size |
| 169 | Size of Tile 600 x 600 mm |
| 170 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 171 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters ,window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 172 | Granite of any colour and shade |
| 173 | Area of slab over 0.50 sqm. |
| 174 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 175 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required. |
| 176 | In grating, frames, guard bar, railing, brackets, gates and similar works. |
| 177 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 178 | 300x16 mm |
| 179 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 180 | 300x10 mm |
| 181 | Providing and fixing aluminium handles, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 182 | 125 mm |
| 183 | Providing and fixing IS : 12817 marked stainless steel butt hinges with steelscrews etc. complete : |
| 184 | 125x64x1.90 mm |
| 185 | Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : |
| 186 | Local best quality Teak wood |
| 187 | Providing and fixing fibre cement high impact polypropylene reinforced roofing accessories in all colour with polymer coated J or L hooks,bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete: |
| 188 | Barge boards |
| 189 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod ofrequired size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes,wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra paymenton this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. |
| 190 | Three track three panels sliding window made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of windowabove 1.75 sqm) |
| 191 | B. Plumbing Work |
| 192 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. |
| 193 | Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete |
| 194 | 10 litre (full flush) capacity-coloured |
| 195 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively withutomatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 196 | One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 197 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: |
| 198 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P.brass pillar taps |
| 199 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P.brass pillar taps |
| 200 | Kitchen sink with drain board |
| 201 | 510x1040 mm bowl depth 250 mm |
| 202 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 203 | Rectangular shape 1500x450 mm |
| 204 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 205 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 206 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 207 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. |
| 208 | Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms |
| 209 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 210 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 211 | Concealed work, including cutting chases and making good the wall etc. |
| 212 | 15 mm nominal outer dia Pipes |
| 213 | 20 mm nominal outer dia Pipes |
| 214 | 25 mm nominal outer dia Pipes |
| 215 | 32 mm nominal outer dia Pipes |
| 216 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 217 | 15 mm nominal bore |
| 218 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 219 | 15 mm nominal bore |
| 220 | Providing and fixing PTMT pillar cock of approved quality and colour. |
| 221 | 15 mm nominal bore, 80 mm long, weighing not less than 46 gms |
| 222 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 223 | External work |
| 224 | 40 mm nominal outer dia Pipes |
| 225 | 65 mm nominal outer dia Pipes |
| 226 | 100 mm nominal outer dia Pipes |
| 227 | External workINTERNAL ELECTRICAL WORKS |
| 228 | Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 229 | Group A |
| 230 | Group B |
| 231 | Group C |
| 232 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loopearthing as required. |
| 233 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 234 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 235 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 236 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 237 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 238 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 239 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 240 | 20 mm |
| 241 | 25 mm |
| 242 | 32 mm |
| 243 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 244 | 5/6 A switch |
| 245 | 3 pin 5/6 A socket outlet |
| 246 | Telephone socket outlet |
| 247 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 248 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 249 | 1 or 2 Module (75mmX75mm) |
| 250 | 4 Module (125mmX75mm) |
| 251 | 6 Module (200mmX75mm) |
| 252 | 8 Module (125mmX125mm) |
| 253 | 12 Module (200mmX150mm) |
| 254 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required |
| 255 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 256 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 257 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 258 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 259 | Upto 450 mm sweep |
| 260 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 261 | 8 way , Double door |
| 262 | Supplying and fixing of following ways surface/ recessmounting, vertical type, 415 V, TPN MCB distribution board ofsheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 263 | 12 way (4 + 36), Double door |
| 264 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 265 | Single pole |
| 266 | Double pole |
| 267 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 268 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 269 | 63 A |
| 270 | Earthing with copper earth plate 600 mm X 600 mm X3 mm thick including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 271 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brassnut bolt & spring washer spaced at 50mm) |
| 272 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 273 | Upto 35 sq. mm |
| 274 | LED Down lighter (COB Type) (System lumenefficacy ≥120 lm/Watt ) |
| 275 | Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 276 | Powdercoateddiecast/Extruded aluminium Body including trim with Aluminium Reflector |
| 277 | 12 -15 watt |
| 278 | 22 watt |
| 279 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value, (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 280 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 281 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealedcopper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). |
| 282 | Inverter Type - Cooling only |
| 283 | 1.5 TRwith 5 Star BEE Rating |
| 284 | Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET3 (Three Phase)with steel cable rope and submersible cable complete as directed and specified by the deptt. |
| 285 | Three phase Submersible motor pump set(Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guarsuitable for 100 mm bore well and above. 3 HP STAGE 6 to 30 with MCB controlled Submersible motor pump setcontrol panel. |
| 286 | Supplyof following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armoured (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . |
| 287 | 3 & 1/2 Core A2XFY |
| 288 | 35.00 Sq.mm.3 & 1/2 Core U.G.armoured cable |
| 289 | Supplying including installation, commissioning of Panel Board |
| 290 | Supplying of followingA.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. |
| 291 | High Speed 225 mm sweep(Havellsmake) |
| 292 | Synthetic Thatch for Roofing |
| 293 | A. 3. Estimate of Festival Ground- Open Gallery Development & VIP Lounge |
| 294 | CIVIL WORKS |
| 295 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 296 | All kinds of soil |
| 297 | Supplying and filling in plinth with sandy soil under floors including, watering,ramming consolidating and dressing complete. |
| 298 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 299 | 1:3:6 ( 1 Cement: 3coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 300 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 301 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 302 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 303 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 304 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 305 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 306 | Suspended floors, roofs, landings, balconies and access platform. |
| 307 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 308 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 309 | Stairs, (excluding landings) except spiral-staircases. |
| 310 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 311 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 312 | Brick work with Ist class common burnt clay F.P.S.(non modular) bricks in superstructure above plinth level upto floor V level in all shapes and sizes in : |
| 313 | Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 314 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in:ve plinth level upto floor V level in all shapes and sizes in : |
| 315 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 316 | 15 mm cement plaster on rough side of single or half brick wall of mix:- |
| 317 | 1:4 (1 cement: 4 fine sand) |
| 318 | 20 mm cement plaster of mix |
| 319 | 1:4 (1 cement: 4 fine sand) |
| 320 | 12 mm cement plaster of mix : |
| 321 | 1:4 (1 cement: 4 fine sand) |
| 322 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws. |
| 323 | Local best quality Teak wood |
| 324 | 35 mm thick |
| 325 | EXTERIOR PAINTS |
| 326 | Finishing walls with textured exterior paint of required shade : |
| 327 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 328 | INTERIOR PAINTS |
| 329 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications : |
| 330 | Two or more coats applied @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @0.75 ltr/10 sqm. |
| 331 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to preparethe surface even and smooth complete. |
| 332 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 333 | Water thinnable cement primer |
| 334 | STEEL REINFORCEMENT |
| 335 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level & above plinth level. |
| 336 | Thermo-Mechanically Treated bars |
| 337 | Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. |
| 338 | Hot finished welded type tubes |
| 339 | Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishng to |
| 340 | a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers,cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 341 | 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part I, |
| 342 | Polishing on wood work with ready made wax polish of approved brand and manufacture : |
| 343 | New work |
| 344 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 345 | 0.63 mm thick with zinc coating not less than 275gm/sqm |
| 346 | Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L ho |
| 347 | 0.63mm thick with zinc coating not less than 275gm/m2 |
| 348 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement [email protected] kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 349 | Double charge vitrified tile polished finish of size |
| 350 | Size of Tile 600 x 600 mm |
| 351 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 352 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters ,window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 353 | Granite of any colour and shade |
| 354 | Area of slab over 0.50 sqm. |
| 355 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 356 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required. |
| 357 | In grating, frames, guard bar, railing, brackets, gates and similar works. |
| 358 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 359 | 300x16 mm |
| 360 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 361 | 300x10 mm |
| 362 | Providing and fixing aluminium handles, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 363 | 125 mm |
| 364 | Providing and fixing IS : 12817 marked stainless steel butt hinges with steelscrews etc. complete : |
| 365 | 125x64x1.90 mm |
| 366 | Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : |
| 367 | Local best quality Teak wood |
| 368 | Providing and fixing fibre cement high impact polypropylene reinforced roofing accessories in all colour with polymer coated J or L hooks,bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete: |
| 369 | Barge boards |
| 370 | Applying priming coat:- |
| 371 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works:- |
| 372 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications : |
| 373 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 374 | Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with : |
| 375 | Cement mortar 1:6(1 cement: 6 coarse sand) |
| 376 | Pointing on stone work with cement mortar 1:3 (1 cement :3 fine sand): |
| 377 | Raised and cut pointing. |
| 378 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads anduPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (whitepowder coated) touch locks with hook, zinc alloy body with single nylonrollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screwsetc. Profile of frame & sash shall be mitred cut and fusion welded at allcorners, including drilling of holes for fixing hardware\"s and drainage ofwater etc. After fixing frame the gap between frame and adjacent finishedwall shall be filled with weather proof silicon sealent over backer rod ofrequired size and of approved quality, all complete as per approveddrawing & direction of Engineer-in-Charge. (Single / double glass panes,wire mesh and silicon sealent shall be paid separately). Variation inprofile dimension in higher side shall be accepted but no extra paymenton this account shall be made. |
| 379 | Note: For uPVC frame and sash extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. |
| 380 | Three track three panels sliding window made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) |
| 381 | B. Plumbing Work |
| 382 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. |
| 383 | Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete |
| 384 | 10 litre (full flush) capacity-coloured |
| 385 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively withutomatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 386 | One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 387 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: |
| 388 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P.brass pillar taps |
| 389 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 390 | Kitchen sink with drain board |
| 391 | 510x1040 mm bowl depth 250 mm |
| 392 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 393 | Rectangular shape 1500x450 mm |
| 394 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 395 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 396 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 397 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. |
| 398 | Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms |
| 399 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 400 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 401 | Concealed work, including cutting chases and making good the wall etc. |
| 402 | 15 mm nominal outer dia Pipes |
| 403 | 20 mm nominal outer dia Pipes |
| 404 | 25 mm nominal outer dia Pipes |
| 405 | 32 mm nominal outer dia Pipes |
| 406 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 407 | 15 mm nominal bore |
| 408 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 409 | 15 mm nominal bore |
| 410 | Providing and fixing PTMT pillar cock of approved quality and colour. |
| 411 | 15 mm nominal bore, 80 mm long, weighing not less than 46 gms |
| 412 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet . |
| 413 | 150 mm diameter |
| 414 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. |
| 415 | 15 mm nominal dia |
| 416 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge |
| 417 | External work |
| 418 | 40 mm nominal outer dia Pipes |
| 419 | 65 mm nominal outer dia Pipes |
| 420 | 100 mm nominal outer dia Pipes |
| 421 | INTERNAL ELECTRICAL WORKS |
| 422 | Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 423 | Group A |
| 424 | Group B |
| 425 | Group C |
| 426 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loopearthing as required. |
| 427 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 428 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 429 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 430 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 431 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 432 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 433 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 434 | 20 mm |
| 435 | 25 mm |
| 436 | 32 mm |
| 437 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 438 | 5/6 A switch |
| 439 | 3 pin 5/6 A socket outlet |
| 440 | Telephone socket outlet |
| 441 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 442 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 443 | 1 or 2 Module (75mmX75mm) |
| 444 | 4 Module (125mmX75mm) |
| 445 | 6 Module (200mmX75mm) |
| 446 | 8 Module (125mmX125mm) |
| 447 | 12 Module (200mmX150mm) |
| 448 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required |
| 449 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 450 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 451 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 452 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 453 | Upto 450 mm sweep |
| 454 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 455 | 8 way , Double door |
| 456 | Supplying and fixing of following ways surface/ recessmounting, vertical type, 415 V, TPN MCB distribution board ofsheet steel, dust protected, duly powder painted, inclusive of200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 457 | 12 way (4 + 36), Double door |
| 458 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 459 | Single pole |
| 460 | Double pole |
| 461 | Supplying and fixing single pole blanking plate in the existingMCB DB complete etc. as required. |
| 462 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 463 | 63 A |
| 464 | Earthing with copper earth plate 600 mm X 600 mm X3 mm thick including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 465 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brassnut bolt & spring washer spaced at 50mm) |
| 466 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 467 | Upto 35 sq. mm |
| 468 | LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt ) |
| 469 | Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 470 | Powdercoateddiecast/Extruded aluminium Body including trim with Aluminium Reflector |
| 471 | 12 -15 watt |
| 472 | 18 watt |
| 473 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value, (CM/M/W) minimum as below, 350 RPM (tolerance asper IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 474 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 475 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealedcopper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). |
| 476 | Inverter Type - Cooling only |
| 477 | 1.5 TRwith 5 Star BEE Rating |
| 478 | Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET3 (Three Phase)with steel cable rope and submersible cable complete as directed and specified by the deptt.y |
| 479 | Three phase Submersible motor pump set(Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guarsuitable for 100 mm bore well and above. 3 HP STAGE 6 to 30 with MCB controlled Submersible motor pump setcontrol panel. |
| 480 | Supplyof following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armoured (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) (Nicco/ Havells/ PG/CCI/Polycab/Gloster/ Finolex make) |
| 481 | 3 & 1/2 Core A2XFY |
| 482 | 35.00 Sq.mm.3 & 1/2 Core U.G.armoured cable |
| 483 | Supplying including installation, commissioning of Panel Board |
| 484 | Supplying of followingA.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. |
| 485 | High Speed 225 mm sweep(Havellsmake) |
| 486 | Synthetic Thatch for Roofing |
| 487 | A. 4. Estimate of Festival Ground- Performance Stage with Green Rooms |
| 488 | CIVIL WORKS |
| 489 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 490 | All kinds of soil |
| 491 | Supplying and filling in plinth with sandy soil under floors including, watering,ramming consolidating and dressing complete. |
| 492 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 493 | 1:3:6 ( 1 Cement: 3coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 494 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 495 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 496 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 497 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 498 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 499 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 500 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 501 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 502 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 503 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 504 | Brick work with Ist class common burnt clay F.P.S.(non modular) bricks in superstructure above plinth level upto floor V level in all shapes and sizes in : |
| 505 | Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 506 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 507 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 508 | 15 mm cement plaster on rough side of single or half brick wall of mix:- |
| 509 | 1:4 (1 cement: 4 fine sand) |
| 510 | 20 mm cement plaster of mix |
| 511 | 1:4 (1 cement: 4 fine sand) |
| 512 | 12 mm cement plaster of mix : |
| 513 | 1:4 (1 cement: 4 fine sand) |
| 514 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws. |
| 515 | Local best quality Teak wood |
| 516 | 35 mm thick |
| 517 | EXTERIOR PAINTS |
| 518 | Finishing walls with textured exterior paint of required shade :AINTS |
| 519 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 520 | INTERIOR PAINTS |
| 521 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications : |
| 522 | Two or more coats applied @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @0.75 ltr/10 sqm. |
| 523 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to preparethe surface even and smooth complete. |
| 524 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 525 | Water thinnable cement primer |
| 526 | STEEL REINFORCEMENT |
| 527 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level & above plinth level. |
| 528 | Thermo-Mechanically Treated bars |
| 529 | Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. |
| 530 | Hot finished welded type tubes |
| 531 | Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishng to |
| 532 | a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers,cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 533 | 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part I, |
| 534 | Polishing on wood work with ready made wax polish of approved brand and manufacture |
| 535 | New work |
| 536 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 537 | 0.63 mm thick with zinc coating not less than 275gm/sqm |
| 538 | Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. |
| 539 | 0.63mm thick with zinc coating not less than 275gm/m2 |
| 540 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement [email protected] kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 541 | Double charge vitrified tile polished finish of size |
| 542 | Size of Tile 600 x 600 mm |
| 543 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 544 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters ,window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 545 | Granite of any colour and shade |
| 546 | Area of slab over 0.50 sqm. |
| 547 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 548 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required. |
| 549 | In grating, frames, guard bar, railing, brackets, gates and similar works. |
| 550 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 551 | 300x16 mm |
| 552 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 553 | 300x10 mm |
| 554 | Providing and fixing aluminium handles, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 555 | 125 mm |
| 556 | Providing and fixing IS : 12817 marked stainless steel butt hinges with steelscrews etc. complete : |
| 557 | 125x64x1.90 mm |
| 558 | Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : |
| 559 | Local best quality Teak wood |
| 560 | Providing and fixing fibre cement high impact polypropylene reinforced roofing accessories in all colour with polymer coated J or L hooks,bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete: |
| 561 | Barge boards |
| 562 | Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with : |
| 563 | Cement mortar 1:6(1 cement: 6 coarse sand) |
| 564 | Pointing on stone work with cement mortar 1:3 (1 cement :3 fine sand): |
| 565 | Raised and cut pointing. |
| 566 | Providing and fixing factory made uPVC white colour sliding glazed windowupto 1.50 m in height dimension comprising of uPVC multi-chamberedframe with in-built roller track and sash extruded profiles duly reinforcedwith 1.60 ± 0.2 mm thick galvanized mild steel section made from rollforming process of required length (shape & size according to uPVCprofile), appropriate dimension of uPVC extruded glazing beads anduPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (whitepowder coated) touch locks with hook, zinc alloy body with single nylonrollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mmsize for fixing frame to finished wall and necessary stainless steel screwsetc. Profile of frame & sash shall be mitred cut and fusion welded at allcorners, including drilling of holes for fixing hardware\"s and drainage ofwater etc. After fixing frame the gap between frame and adjacent finishedwall shall be filled with weather proof silicon sealent over backer rod ofrequired size and of approved quality, all complete as per approveddrawing & direction of Engineer-in-Charge. (Single / double glass panes,wire mesh and silicon sealent shall be paid separately). Variation inprofile dimension in higher side shall be accepted but no extra paymenton this account shall be made. |
| 567 | Note: For uPVC frame and sash extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptabl |
| 568 | Three track three panels sliding window made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of windowabove 1.75 sqm) |
| 569 | B. Plumbing Work |
| 570 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. |
| 571 | Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete |
| 572 | 10 litre (full flush) capacity-coloured |
| 573 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively withutomatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 574 | One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 575 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: |
| 576 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P.brass pillar taps |
| 577 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 578 | Rectangular shape 1500x450 mm |
| 579 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 580 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 581 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 582 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. |
| 583 | Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms |
| 584 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 585 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 586 | Concealed work, including cutting chases and making good the wall etc. |
| 587 | Concealed work, including cutting chases and making good the wall etc. |
| 588 | 15 mm nominal outer dia Pipes |
| 589 | 20 mm nominal outer dia Pipes |
| 590 | 25 mm nominal outer dia Pipes |
| 591 | 32 mm nominal outer dia Pipes |
| 592 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 593 | 15 mm nominal bore |
| 594 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 595 | 15 mm nominal bore |
| 596 | Providing and fixing PTMT pillar cock of approved quality and colour. |
| 597 | 15 mm nominal bore, 80 mm long, weighing not less than 46 gms |
| 598 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 599 | External work |
| 600 | 40 mm nominal outer dia Pipes |
| 601 | 65 mm nominal outer dia Pipes |
| 602 | 100 mm nominal outer dia Pipes |
| 603 | INTERNAL ELECTRICAL WORKS |
| 604 | Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 605 | Group A |
| 606 | Group B |
| 607 | Group C |
| 608 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loopearthing as required. |
| 609 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 610 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 611 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 612 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 613 | 20 mm |
| 614 | 25 mm |
| 615 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 616 | 5/6 A switch |
| 617 | 3 pin 5/6 A socket outlet |
| 618 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 619 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 620 | 4 Module (125mmX75mm) |
| 621 | 12 Module (200mmX150mm) |
| 622 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required |
| 623 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 624 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 625 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 626 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 627 | Upto 450 mm sweep |
| 628 | Supplying and fixing of following ways surface/ recessmounting, vertical type, 415 V, TPN MCB distribution board ofsheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 629 | 8 way (4 + 24), Double door |
| 630 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 631 | Single pole |
| 632 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 633 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 634 | 63 A |
| 635 | Earthing with copper earth plate 600 mm X 600 mm X3 mm thick including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 636 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 637 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 638 | Above 35 sq. mm and upto 95 sq. mm |
| 639 | LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt ) |
| 640 | Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 641 | Powdercoateddiecast/Extruded aluminium Body including trim with Aluminium Reflector |
| 642 | 12 -15 watt |
| 643 | 18 watt |
| 644 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value, (CM/M/W) minimum as below, 350 RPM (tolerance per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 645 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 646 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealedcopper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). |
| 647 | Inverter Type - Cooling only |
| 648 | 1.5 TRwith 5 Star BEE Rating |
| 649 | Supplyof following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armoured (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . |
| 650 | 3 & 1/2 Core A2XFY |
| 651 | 50.00 Sq.mm.3 & 1/2 Core U.G.armoured cable |
| 652 | Supplying including installation, commissioning of Panel Board |
| 653 | Supplying of followingA.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. |
| 654 | High Speed 225 mm sweep(Havellsmake) |
| 655 | Synthetic Thatch for Roofing |
| 656 | A. 5. Estimate of Vendor Haat -6 Nos. |
| 657 | CIVIL WORKS |
| 658 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 659 | All kinds of soil |
| 660 | Supplying and filling in plinth with sandy soil under floors including, watering,ramming consolidating and dressing complete. |
| 661 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 662 | 1:3:6 ( 1 Cement: 3coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 663 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 664 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 665 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 666 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 667 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 668 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 669 | Suspended floors, roofs, landings, balconies and access platform. |
| 670 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 671 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 672 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 673 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 674 | Brick work with Ist class common burnt clay F.P.S.(non modular) bricks in superstructure above plinth level upto floor V level in all shapes and sizes in : |
| 675 | Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 676 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 677 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 678 | 15 mm cement plaster on rough side of single or half brick wall of mix:- |
| 679 | 1:4 (1 cement: 4 fine sand) |
| 680 | 20 mm cement plaster of mix |
| 681 | 1:4 (1 cement: 4 fine sand) |
| 682 | 12 mm cement plaster of mix : |
| 683 | 1:4 (1 cement: 4 fine sand) |
| 684 | EXTERIOR PAINTS |
| 685 | EXTERIOR PAINTSFinishing walls with textured exterior paint of required shade : |
| 686 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 687 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to preparethe surface even and smooth complete. |
| 688 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 689 | Water thinnable cement primer |
| 690 | STEEL REINFORCEMENT |
| 691 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level & above plinth level. |
| 692 | Thermo-Mechanically Treated bars |
| 693 | Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete.T |
| 694 | Hot finished welded type tubes |
| 695 | Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishng to |
| 696 | a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers,cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 697 | 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part I, |
| 698 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 699 | 0.63 mm thick with zinc coating not less than 275gm/sqm |
| 700 | Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. |
| 701 | 0.63mm thick with zinc coating not less than 275gm/m2 |
| 702 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement [email protected] kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 703 | Double charge vitrified tile polished finish of size |
| 704 | Size of Tile 600 x 600 mm |
| 705 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters ,window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 706 | Granite of any colour and shade |
| 707 | Area of slab over 0.50 sqm. |
| 708 | Providing and fixing fibre cement high impact polypropylene reinforced roofing accessories in all colour with polymer coated J or L hooks,bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete: |
| 709 | Barge boards |
| 710 | Applying priming coat:- |
| 711 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works:- |
| 712 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications : |
| 713 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 714 | INTERNAL ELECTRICAL WORKS |
| 715 | Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 716 | Group A |
| 717 | Group B |
| 718 | Group C |
| 719 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required. |
| 720 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 721 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 722 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 723 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 724 | 25 mm |
| 725 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 726 | 5/6 A switch |
| 727 | 3 pin 5/6 A socket outlet |
| 728 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 729 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 730 | 12 Module (200mmX150mm) |
| 731 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required |
| 732 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 733 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 734 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 735 | 8 way , Double door |
| 736 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 737 | Single pole |
| 738 | Double pole |
| 739 | Supplying and fixing single pole blanking plate in the existingMCB DB complete etc. as required. |
| 740 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 741 | Upto 35 sq. mm |
| 742 | LED Down lighter (COB Type) (System lumenefficacy ≥120 lm/Watt ) |
| 743 | Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 744 | Powdercoateddiecast/Extruded aluminium Body including trim with Aluminium Reflector |
| 745 | 12 -15 watt |
| 746 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value, (CM/M/W) minimum as below, 350 RPM (tolerance asper IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 747 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 748 | Supplyof following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armoured (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . |
| 749 | 10 00 Sq.mm 3 Core U.G.armoured cable |
| 750 | Synthetic Thatch for Roofing |
| 751 | A. 6. Estimate of Public Convenience with Drinking Water |
| 752 | CIVIL WORKS |
| 753 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 754 | All kinds of soil |
| 755 | Supplying and filling in plinth with sandy soil under floors including, watering,ramming consolidating and dressing complete. |
| 756 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 757 | 1:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 758 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 759 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 760 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 761 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 762 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 763 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 764 | Suspended floors, roofs, landings, balconies and access platform. |
| 765 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 766 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 767 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 768 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 769 | Brick work with Ist class common burnt clay F.P.S.(non modular) bricks in superstructure above plinth level upto floor V level in all shapes and sizes in : |
| 770 | Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 771 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 772 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 773 | 15 mm cement plaster on rough side of single or half brick wall of mix:- |
| 774 | 1:4 (1 cement: 4 fine sand) |
| 775 | 20 mm cement plaster of mix |
| 776 | 1:4 (1 cement: 4 fine sand) |
| 777 | 12 mm cement plaster of mix : |
| 778 | 1:4 (1 cement: 4 fine sand) |
| 779 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws. |
| 780 | Local best quality Teak wood |
| 781 | 35 mm thick |
| 782 | EXTERIOR PAINTS |
| 783 | Finishing walls with textured exterior paint of required shade : |
| 784 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 785 | INTERIOR PAINTS |
| 786 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications : |
| 787 | Two or more coats applied @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @0.75 ltr/10 sqm. |
| 788 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to preparethe surface even and smooth complete. |
| 789 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 790 | Water thinnable cement primer |
| 791 | STEEL REINFORCEMENT |
| 792 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level & above plinth level. |
| 793 | Thermo-Mechanically Treated bars |
| 794 | Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. |
| 795 | Hot finished welded type tubes |
| 796 | Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishng to |
| 797 | a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers,cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 798 | 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part I, |
| 799 | Polishing on wood work with ready made wax polish of approved brand and manufacture : |
| 800 | New work |
| 801 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 802 | 0.63 mm thick with zinc coating not less than 275gm/sqm |
| 803 | Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. |
| 804 | 0.63mm thick with zinc coating not less than 275gm/m2 |
| 805 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 806 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters ,window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 807 | Granite of any colour and shade |
| 808 | Area of slab over 0.50 sqm. |
| 809 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 810 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 811 | 300x16 mm |
| 812 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 813 | 300x10 mm |
| 814 | Providing and fixing aluminium handles, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 815 | 125 mm |
| 816 | Providing and fixing IS : 12817 marked stainless steel butt hinges with steelscrews etc. complete : |
| 817 | 125x64x1.90 mm |
| 818 | Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : |
| 819 | Local best quality Teak wood |
| 820 | Providing and fixing fibre cement high impact polypropylene reinforced roofing accessories in all colour with polymer coated J or L hooks,bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete: |
| 821 | Barge boards |
| 822 | Applying priming coat:- |
| 823 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works:- |
| 824 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications : |
| 825 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 826 | Providing and fixing factory made uPVC white colour sliding glazed windowupto 1.50 m in height dimension comprising of uPVC multi-chamberedframe with in-built roller track and sash extruded profiles duly reinforcedwith 1.60 ± 0.2 mm thick galvanized mild steel section made from rollforming process of required length (shape & size according to uPVCprofile), appropriate dimension of uPVC extruded glazing beads anduPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (whitepowder coated) touch locks with hook, zinc alloy body with single nylonrollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mmsize for fixing frame to finished wall and necessary stainless steel screwsetc. Profile of frame & sash shall be mitred cut and fusion welded at allcorners, including drilling of holes for fixing hardware\"s and drainage ofwater etc. After fixing frame the gap between frame and adjacent finishedwall shall be filled with weather proof silicon sealent over backer rod ofrequired size and of approved quality, all complete as per approveddrawing & direction of Engineer-in-Charge. (Single / double glass panes,wire mesh and silicon sealent shall be paid separately). Variation inprofile dimension in higher side shall be accepted but no extra paymenton this account shall be made. |
| 827 | Note: For uPVC frame and sash extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. |
| 828 | Three track three panels sliding window made of (big series)frame 116 x 45 mm & sash 46 x 62 mm both having wallthickness of 2.3 ± 0.2 mm and single glazing bead / doubleglazing bead of appropriate dimension. (Area of windowabove 1.75 sqm) |
| 829 | B. Plumbing Work |
| 830 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. |
| 831 | Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete |
| 832 | 10 litre (full flush) capacity-coloured |
| 833 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively withutomatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 834 | One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 835 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: |
| 836 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P.brass pillar taps |
| 837 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 838 | Rectangular shape 1500x450 mm |
| 839 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 840 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 841 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 842 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. |
| 843 | Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms |
| 844 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 845 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 846 | Concealed work, including cutting chases and making good the wall etc. |
| 847 | 15 mm nominal outer dia Pipes |
| 848 | 20 mm nominal outer dia Pipes |
| 849 | 25 mm nominal outer dia Pipes |
| 850 | 32 mm nominal outer dia Pipes |
| 851 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 852 | 15 mm nominal bore |
| 853 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 854 | 15 mm nominal bore |
| 855 | Providing and fixing PTMT pillar cock of approved quality and colour. |
| 856 | 15 mm nominal bore, 80 mm long, weighing not less than 46 gms |
| 857 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
| 858 | 150 mm diameter |
| 859 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. |
| 860 | 15 mm nominal dia |
| 861 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 862 | External work |
| 863 | 65 mm nominal outer dia Pipes |
| 864 | 100 mm nominal outer dia Pipes |
| 865 | INTERNAL ELECTRICAL WORKS |
| 866 | Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 867 | Group A |
| 868 | Group B |
| 869 | Group C |
| 870 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loopearthing as required. |
| 871 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 872 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 873 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 874 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 875 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 876 | 20 mm |
| 877 | 25 mm |
| 878 | 32 mm |
| 879 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 880 | 5/6 A switch |
| 881 | 3 pin 5/6 A socket outlet |
| 882 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 883 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 884 | 1 or 2 Module (75mmX75mm) |
| 885 | 4 Module (125mmX75mm) |
| 886 | 6 Module (200mmX75mm) |
| 887 | 8 Module (125mmX125mm) |
| 888 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required |
| 889 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 890 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 891 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 892 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 893 | Upto 450 mm sweep |
| 894 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 895 | 8 way , Double door |
| 896 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 897 | Single pole |
| 898 | Double pole |
| 899 | Supplying and fixing single pole blanking plate in the existingMCB DB complete etc. as required. |
| 900 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 901 | Upto 35 sq. mm |
| 902 | LED Down lighter (COB Type) (System lumenefficacy ≥120 lm/Watt ) |
| 903 | Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 904 | Powdercoateddiecast/Extruded aluminium Body including trim with Aluminium Reflector |
| 905 | 12 -15 watt |
| 906 | Supplyof following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armoured (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . |
| 907 | 3 Core A2XFY |
| 908 | 16.00 Sq.mm.3 & 1/2 Core U.G.armoured cable |
| 909 | A.7. Extension of Existing Guest House |
| 910 | CIVIL WORKS |
| 911 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 912 | All kinds of soil |
| 913 | Supplying and filling in plinth with sandy soil under floors including, watering,ramming consolidating and dressing complete. |
| 914 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 915 | 1:3:6 ( 1 Cement: 3coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 916 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 917 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 918 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 919 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 920 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 921 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 922 | Suspended floors, roofs, landings, balconies and access platform. |
| 923 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 924 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 925 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 926 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 927 | Brick work with Ist class common burnt clay F.P.S.(non modular) bricks in superstructure above plinth level upto floor V level in all shapes and sizes in : |
| 928 | Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 929 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 930 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 931 | 15 mm cement plaster on rough side of single or half brick wall of mix:- |
| 932 | 1:4 (1 cement: 4 fine sand) |
| 933 | 20 mm cement plaster of mix |
| 934 | 1:4 (1 cement: 4 fine sand) |
| 935 | 12 mm cement plaster of mix : |
| 936 | 1:4 (1 cement: 4 fine sand) |
| 937 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws. |
| 938 | Local best quality Teak wood |
| 939 | 35 mm thick |
| 940 | EXTERIOR PAINTS |
| 941 | Finishing walls with textured exterior paint of required shade : |
| 942 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 943 | INTERIOR PAINTS |
| 944 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications : |
| 945 | Two or more coats applied @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @0.75 ltr/10 sqm. |
| 946 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to preparethe surface even and smooth complete. |
| 947 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 948 | Water thinnable cement primer |
| 949 | STEEL REINFORCEMENT |
| 950 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level & above plinth level. |
| 951 | Thermo-Mechanically Treated bars |
| 952 | Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. |
| 953 | Hot finished welded type tubes |
| 954 | Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishng to |
| 955 | a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers,cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 956 | 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part I, |
| 957 | Polishing on wood work with ready made wax polish of approved brand and manufacture : |
| 958 | New work |
| 959 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 960 | 0.63 mm thick with zinc coating not less than 275gm/sqm |
| 961 | Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. |
| 962 | 0.63mm thick with zinc coating not less than 275gm/m2 |
| 963 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement [email protected] kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 964 | Double charge vitrified tile polished finish of size |
| 965 | Size of Tile 600 x 600 mm |
| 966 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 967 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters ,window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 968 | Granite of any colour and shade |
| 969 | Area of slab over 0.50 sqm. |
| 970 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 971 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required. |
| 972 | In grating, frames, guard bar, railing, brackets, gates and similar works. |
| 973 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 974 | 300x16 mm |
| 975 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 976 | 300x10 mm |
| 977 | Providing and fixing aluminium handles, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 978 | 125 mm |
| 979 | Providing and fixing IS : 12817 marked stainless steel butt hinges with steelscrews etc. complete : |
| 980 | 125x64x1.90 mm |
| 981 | Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : |
| 982 | Local best quality Teak wood |
| 983 | Providing and fixing fibre cement high impact polypropylene reinforced roofing accessories in all colour with polymer coated J or L hooks,bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete: |
| 984 | Barge boards |
| 985 | Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with : |
| 986 | Cement mortar 1:6(1 cement: 6 coarse sand) |
| 987 | Pointing on stone work with cement mortar 1:3 (1 cement :3 fine sand): |
| 988 | Raised and cut pointing. |
| 989 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads anduPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage ofwater etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 990 | Note: For uPVC frame and sash extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. |
| 991 | Three track three panels sliding window made of (big series)frame 116 x 45 mm & sash 46 x 62 mm both having wallthickness of 2.3 ± 0.2 mm and single glazing bead / doubleglazing bead of appropriate dimension. (Area of windowabove 1.75 sqm) |
| 992 | B. Plumbing Work |
| 993 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. |
| 994 | Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete |
| 995 | 10 litre (full flush) capacity-coloured |
| 996 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively withutomatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 997 | One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 998 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: |
| 999 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P.brass pillar taps |
| 1000 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 1001 | Kitchen sink with drain board |
| 1002 | 510x1040 mm bowl depth 250 mm |
| 1003 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic |
| 1004 | Rectangular shape 1500x450 mm |
| 1005 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 1006 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 1007 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 1008 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. |
| 1009 | Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms |
| 1010 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 1011 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 1012 | Concealed work, including cutting chases and making good the wall etc. |
| 1013 | 15 mm nominal outer dia Pipes |
| 1014 | 20 mm nominal outer dia Pipes |
| 1015 | 25 mm nominal outer dia Pipes |
| 1016 | 32 mm nominal outer dia Pipes |
| 1017 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 1018 | 15 mm nominal bore |
| 1019 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 1020 | 15 mm nominal bore |
| 1021 | Providing and fixing PTMT pillar cock of approved quality and colour. |
| 1022 | 15 mm nominal bore, 80 mm long, weighing not less than 46 gms |
| 1023 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 1024 | External work |
| 1025 | 40 mm nominal outer dia Pipes |
| 1026 | 65 mm nominal outer dia Pipes |
| 1027 | 100 mm nominal outer dia Pipes |
| 1028 | INTERNAL ELECTRICAL WORKS |
| 1029 | Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 1030 | Group A |
| 1031 | Group B |
| 1032 | Group C |
| 1033 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loopearthing as required. |
| 1034 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 1035 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 1036 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 1037 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 1038 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 1039 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 1040 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 1041 | 20 mm |
| 1042 | 25 mm |
| 1043 | 32 mm |
| 1044 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 1045 | 5/6 A switch |
| 1046 | 3 pin 5/6 A socket outlet |
| 1047 | Telephone socket outlet |
| 1048 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 1049 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 1050 | 1 or 2 Module (75mmX75mm) |
| 1051 | 4 Module (125mmX75mm) |
| 1052 | 6 Module (200mmX75mm) |
| 1053 | 8 Module (125mmX125mm) |
| 1054 | 12 Module (200mmX150mm) |
| 1055 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required |
| 1056 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 1057 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 1058 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 1059 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 1060 | Upto 450 mm sweep |
| 1061 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 1062 | 8 way , Double door |
| 1063 | Supplying and fixing of following ways surface/ recessmounting, vertical type, 415 V, TPN MCB distribution board ofsheet steel, dust protected, duly powder painted, inclusive of200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 1064 | 12 way (4 + 36), Double door |
| 1065 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 1066 | Single pole |
| 1067 | Double pole |
| 1068 | Supplying and fixing single pole blanking plate in the existingMCB DB complete etc. as required. |
| 1069 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 1070 | 63 A |
| 1071 | Earthing with copper earth plate 600 mm X 600 mm X3 mm thick including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 1072 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brassnut bolt & spring washer spaced at 50mm) |
| 1073 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 1074 | Upto 35 sq. mm |
| 1075 | Above 35 sq. mm and upto 95 sq. mm |
| 1076 | LED Down lighter (COB Type) (System lumenefficacy ≥120 lm/Watt ) |
| 1077 | Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 1078 | Powdercoateddiecast/Extruded aluminium Body including trim with Aluminium Reflector |
| 1079 | 12 -15 watt |
| 1080 | 18 watt |
| 1081 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value, (CM/M/W) minimum as below, 350 RPM (tolerance asper IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 1082 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 1083 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealedcopper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). |
| 1084 | Inverter Type - Cooling only |
| 1085 | 1.0 TR with 5 Star BEE Rating |
| 1086 | 1.5 TRwith 5 Star BEE Rating |
| 1087 | Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET3 (Three Phase)with steel cable rope and submersible cable complete as directed and specified by the deptt. |
| 1088 | Three phase Submersible motor pump set(Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guarsuitable for 100 mm bore well and above. 3 HP STAGE 6 to 30 with MCB controlled Submersible motor pump setcontrol panel. |
| 1089 | Supplyof following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armoured (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . |
| 1090 | 3 & 1/2 Core A2XFY |
| 1091 | 50.00 Sq.mm.3 & 1/2 Core U.G.armoured cable |
| 1092 | 95.00 Sq.mm.3 & 1/2 Core U.G.armoured cable |
| 1093 | Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical indoor type floor/wall mounting compartmentalize panel board of size 1.45M X 1.55MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and35mm X 35mm X 5mm size angle having 4 no legs at the bottom. The panel board is to be erected in 1 : 3 : 6 PCC foundation including brick soling / grouting etc. complete neatly Wiring done with provision for one no 315A 4pole MCCB or Switch Fuse Unit as incomer and provision for 8nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items: 1. 30mm X 5mm 4 strip copper Bus - Bar 1.45 M length each i20mm X 3mm 4 strip copper Bus-Bar 0.5M each 8sets 2. Digital 3 Phase Voltmeter Accuracy class 0.5- 1 no 3. Digital 3 Phase Ammeter Accuracy class 0.5- 1 no 4. Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 no 5. Voltmeter & Ammeter Selector Switch- 2 no 6. 2 A Slide fuse unit - 3nos |
| 1094 | Supplying including installation, commissioning of Panel Board |
| 1095 | Supplying of followingA.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. |
| 1096 | High Speed 225 mm sweep(Havellsmake) |
| 1097 | Synthetic Thatch for Roofing |
| 1098 | A. 8. i) Estimate of Boundary Wall |
| 1099 | CIVIL WORKS |
| 1100 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 1101 | All kinds of soil |
| 1102 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 1103 | 1:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 1104 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 1105 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 1106 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 1107 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 1108 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 1109 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 1110 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 1111 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 1112 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1113 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 1114 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1115 | 15 mm cement plaster on rough side of single or half brick wall of mix:- |
| 1116 | 1:4 (1 cement: 4 fine sand) |
| 1117 | EXTERIOR PAINTS |
| 1118 | Finishing walls with textured exterior paint of required shade : |
| 1119 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 1120 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to preparethe surface even and smooth complete. |
| 1121 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 1122 | Water thinnable cement primer |
| 1123 | STEEL REINFORCEMENT |
| 1124 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level & above plinth level. |
| 1125 | Thermo-Mechanically Treated bars |
| 1126 | Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. |
| 1127 | Hot finished welded type tubes |
| 1128 | Applying priming coat:- |
| 1129 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works:- |
| 1130 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications : |
| 1131 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 1132 | A. 8. ii) Estimate of CCTV System |
| 1133 | CCTV System |
| 1134 | A. 9. Estimate of Single Cottages - 14 Nos |
| 1135 | CIVIL WORKS |
| 1136 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge.: |
| 1137 | All kinds of soil |
| 1138 | Supplying and filling in plinth with sandy soil under floors including, watering,ramming consolidating and dressing complete. |
| 1139 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 1140 | 1:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 1141 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 1142 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 1143 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 1144 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 1145 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 1146 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 1147 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 1148 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 1149 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1150 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 1151 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1152 | 12 mm cement plaster of mix : |
| 1153 | 1:4 (1 cement: 4 fine sand) |
| 1154 | STEEL REINFORCEMENT |
| 1155 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level & above plinth level. |
| 1156 | Thermo-Mechanically Treated bars |
| 1157 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters ,window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 1158 | Granite of any colour and shade |
| 1159 | Area of slab over 0.50 sqm. |
| 1160 | B. Plumbing Work |
| 1161 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 1162 | External work |
| 1163 | 65 mm nominal outer dia Pipes |
| 1164 | 100 mm nominal outer dia Pipes |
| 1165 | RATE AS PER CPWD DSR (E&M) 2025 |
| 1166 | Earthing with copper earth plate 600 mm X 600 mm X3 mm thick including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 1167 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brassnut bolt & spring washer spaced at 50mm) |
| 1168 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealedcopper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). |
| 1169 | Inverter Type - Cooling only |
| 1170 | 1.5 TRwith 5 Star BEE Rating |
| 1171 | Supplyof following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armoured (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . |
| 1172 | 3 & 1/2 Core A2XFY |
| 1173 | 25.00 Sq.mm.3 & 1/2 Core U.G.armoured cable |
| 1174 | Wooden Log-Hut |
| 1175 | Synthetic Thatch for Roofing |
| 1176 | A. 10. Estimate of Twin Cottages -4Nos |
| 1177 | CIVIL WORKS |
| 1178 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 1179 | All kinds of soil |
| 1180 | Supplying and filling in plinth with sandy soil under floors including, watering,ramming consolidating and dressing complete. |
| 1181 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 1182 | 1:3:6 ( 1 Cement: 3coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 1183 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 1184 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 1185 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 1186 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 1187 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 1188 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 1189 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 1190 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 1191 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1192 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 1193 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1194 | 12 mm cement plaster of mix : |
| 1195 | 1:4 (1 cement: 4 fine sand) |
| 1196 | STEEL REINFORCEMENT |
| 1197 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level & above plinth level. |
| 1198 | Thermo-Mechanically Treated bars |
| 1199 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters ,window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 1200 | Granite of any colour and shade |
| 1201 | Area of slab over 0.50 sqm. |
| 1202 | B. Plumbing Work |
| 1203 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge |
| 1204 | External work |
| 1205 | 65 mm nominal outer dia Pipes |
| 1206 | 100 mm nominal outer dia Pipes |
| 1207 | Earthing with copper earth plate 600 mm X 600 mm X3 mm thick including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 1208 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brassnut bolt & spring washer spaced at 50mm) |
| 1209 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealedcopper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). |
| 1210 | Inverter Type - Cooling only |
| 1211 | 1.5 TRwith 5 Star BEE Rating |
| 1212 | Supplyof following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armoured (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . |
| 1213 | 3 & 1/2 Core A2XFY |
| 1214 | 25.00 Sq.mm.3 & 1/2 Core U.G.armoured cable |
| 1215 | Wooden Log-Hut |
| 1216 | Synthetic Thatch for Roofing |
| 1217 | A. 11. Estimate of Main Block with Café & Theme Restaurant |
| 1218 | CIVIL WORKS |
| 1219 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 1220 | All kinds of soil |
| 1221 | Supplying and filling in plinth with sandy soil under floors including, watering,ramming consolidating and dressing complete. |
| 1222 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 1223 | 1:3:6 ( 1 Cement: 3coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 1224 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 1225 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 1226 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 1227 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 1228 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 1229 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 1230 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 1231 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 1232 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1233 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 1234 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1235 | 12 mm cement plaster of mix : |
| 1236 | 1:4 (1 cement: 4 fine sand) |
| 1237 | STEEL REINFORCEMENT : |
| 1238 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level & above plinth level. |
| 1239 | Thermo-Mechanically Treated bars |
| 1240 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters ,window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 1241 | Granite of any colour and shade |
| 1242 | Area of slab over 0.50 sqm. |
| 1243 | B. Plumbing Work |
| 1244 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 1245 | External work |
| 1246 | 65 mm nominal outer dia Pipes |
| 1247 | 100 mm nominal outer dia Pipes |
| 1248 | Earthing with copper earth plate 600 mm X 600 mm X3 mm thick including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 1249 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brassnut bolt & spring washer spaced at 50mm) |
| 1250 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealedcopper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). |
| 1251 | Inverter Type - Cooling only |
| 1252 | 2.0TRwith 5 Star BEE Rating |
| 1253 | Supplyof following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armoured (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . |
| 1254 | 3 & 1/2 Core A2XFY |
| 1255 | 25.00 Sq.mm.3 & 1/2 Core U.G.armoured cable |
| 1256 | 95.00 Sq.mm.3 & 1/2 Core U.G.armoured cable |
| 1257 | Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical indoor type floor/wall mounting compartmentalize panel board of size 1.45M X 1.55MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and35mm X 35mm X 5mm size angle having 4 no legs at the bottom. The panel board is to be erected in 1 : 3 : 6 PCC foundation including brick soling / grouting etc. complete neatly Wiring done with provision for one no 315A 4pole MCCB or Switch Fuse Unit as incomer and provision for 8nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items: 1. 30mm X 5mm 4 strip copper Bus - Bar 1.45 M length each i20mm X 3mm 4 strip copper Bus-Bar 0.5M each 8sets 2. Digital 3 Phase Voltmeter Accuracy class 0.5- 1 no 3. Digital 3 Phase Ammeter Accuracy class 0.5- 1 no 4. Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 no 5. Voltmeter & Ammeter Selector Switch- 2 no 6. 2 A Slide fuse unit - 3nos |
| 1258 | Wooden Log-Hut |
| 1259 | Synthetic Thatch for Roofing |
| 1260 | A. 12. ESTIMATE OF GAZEBO - 2 Nos |
| 1261 | CIVIL WORKS |
| 1262 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 1263 | All kinds of soil |
| 1264 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 1265 | 1:3:6 ( 1 Cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 1266 | Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with : |
| 1267 | Cement mortar 1:6(1 cement: 6 coarse sand) |
| 1268 | Pointing on stone work with cement mortar 1:3 (1 cement :3 fine sand):: |
| 1269 | Raised and cut pointing. |
| 1270 | Pre Fabricated Wooden Gazebo |
| 1271 | 13. Estimate of Staff Facilities |
| 1272 | CIVIL WORKS |
| 1273 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 1274 | All kinds of soil |
| 1275 | Supplying and filling in plinth with sandy soil under floors including, watering,ramming consolidating and dressing complete. |
| 1276 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 1277 | 1:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 1278 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 1279 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 1280 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 1281 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 1282 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 1283 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 1284 | Suspended floors, roofs, landings, balconies and access platform. |
| 1285 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 1286 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 1287 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 1288 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1289 | Brick work with Ist class common burnt clay F.P.S.(non modular) bricks in superstructure above plinth level upto floor V level in all shapes and sizes in : |
| 1290 | Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 1291 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 1292 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1293 | 15 mm cement plaster on rough side of single or half brick wall of mix:- |
| 1294 | 1:4 (1 cement: 4 fine sand) |
| 1295 | 20 mm cement plaster of mix |
| 1296 | 1:4 (1 cement: 4 fine sand) |
| 1297 | 12 mm cement plaster of mix : |
| 1298 | 1:4 (1 cement: 4 fine sand) |
| 1299 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws. |
| 1300 | Local best quality Teak wood |
| 1301 | 35 mm thick |
| 1302 | EXTERIOR PAINTS |
| 1303 | Finishing walls with textured exterior paint of required shade : |
| 1304 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 1305 | INTERIOR PAINTS |
| 1306 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications : |
| 1307 | Two or more coats applied @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @0.75 ltr/10 sqm. |
| 1308 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to preparethe surface even and smooth complete. |
| 1309 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 1310 | Water thinnable cement primer |
| 1311 | STEEL REINFORCEMENT |
| 1312 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level & above plinth level. |
| 1313 | Thermo-Mechanically Treated bars |
| 1314 | Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. |
| 1315 | Hot finished welded type tubes |
| 1316 | Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishng to |
| 1317 | a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers,cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 1318 | 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part I, |
| 1319 | Polishing on wood work with ready made wax polish of approved brand and manufacture : |
| 1320 | New work |
| 1321 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 1322 | 0.63 mm thick with zinc coating not less than 275gm/sqm |
| 1323 | Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. |
| 1324 | 0.63mm thick with zinc coating not less than 275gm/m2 |
| 1325 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement [email protected] kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 1326 | Double charge vitrified tile polished finish of size |
| 1327 | Size of Tile 600 x 600 mm |
| 1328 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 1329 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters ,window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 1330 | Granite of any colour and shade |
| 1331 | Area of slab over 0.50 sqm. |
| 1332 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 1333 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required. |
| 1334 | In grating, frames, guard bar, railing, brackets, gates and similar works. |
| 1335 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 1336 | 300x16 mm |
| 1337 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 1338 | 300x10 mm |
| 1339 | Providing and fixing aluminium handles, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 1340 | 125 mm |
| 1341 | Providing and fixing IS : 12817 marked stainless steel butt hinges with steelscrews etc. complete : |
| 1342 | 125x64x1.90 mm |
| 1343 | Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : |
| 1344 | Local best quality Teak wood |
| 1345 | Providing and fixing fibre cement high impact polypropylene reinforced roofing accessories in all colour with polymer coated J or L hooks,bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete: |
| 1346 | Barge boards |
| 1347 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chamberedframe with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from rollforming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finishedwall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approveddrawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 1348 | Note: For uPVC frame and sash extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. |
| 1349 | Three track three panels sliding window made of (big series)frame 116 x 45 mm & sash 46 x 62 mm both having wallthickness of 2.3 ± 0.2 mm and single glazing bead / doubleglazing bead of appropriate dimension. (Area of windowabove 1.75 sqm) |
| 1350 | B. Plumbing Work |
| 1351 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. |
| 1352 | Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete |
| 1353 | 10 litre (full flush) capacity-coloured |
| 1354 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively withutomatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :lete |
| 1355 | One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 1356 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: |
| 1357 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P.brass pillar taps |
| 1358 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 1359 | Kitchen sink with drain board |
| 1360 | 510x1040 mm bowl depth 250 mm |
| 1361 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 1362 | Rectangular shape 1500x450 mm |
| 1363 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 1364 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 1365 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 1366 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.. |
| 1367 | Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms |
| 1368 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 1369 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 1370 | Concealed work, including cutting chases and making good the wall etc. |
| 1371 | 15 mm nominal outer dia Pipes |
| 1372 | 20 mm nominal outer dia Pipes |
| 1373 | 25 mm nominal outer dia Pipes |
| 1374 | 32 mm nominal outer dia Pipes |
| 1375 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 1376 | 15 mm nominal bore |
| 1377 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 1378 | 15 mm nominal bore |
| 1379 | Providing and fixing PTMT pillar cock of approved quality and colour. |
| 1380 | 15 mm nominal bore, 80 mm long, weighing not less than 46 gms |
| 1381 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
| 1382 | 150 mm diameter |
| 1383 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. |
| 1384 | 15 mm nominal dia |
| 1385 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 1386 | External work |
| 1387 | 40 mm nominal outer dia Pipes |
| 1388 | 65 mm nominal outer dia Pipes |
| 1389 | 100 mm nominal outer dia Pipes |
| 1390 | INTERNAL ELECTRICAL WORKS |
| 1391 | Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 1392 | Group A |
| 1393 | Group B |
| 1394 | Group C |
| 1395 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loopearthing as required. |
| 1396 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 1397 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 1398 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 1399 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 1400 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 1401 | 25 mm |
| 1402 | 32 mm |
| 1403 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 1404 | 5/6 A switch |
| 1405 | 3 pin 5/6 A socket outlet |
| 1406 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 1407 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 1408 | 1 or 2 Module (75mmX75mm) |
| 1409 | 4 Module (125mmX75mm) |
| 1410 | 8 Module (125mmX125mm) |
| 1411 | 12 Module (200mmX150mm) |
| 1412 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required |
| 1413 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 1414 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 1415 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 1416 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 1417 | Upto 450 mm sweep |
| 1418 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 1419 | 8 way , Double door |
| 1420 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 1421 | Single pole |
| 1422 | Double pole |
| 1423 | Supplying and fixing single pole blanking plate in the existingMCB DB complete etc. as required. |
| 1424 | Earthing with copper earth plate 600 mm X 600 mm X3 mm thick including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 1425 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 1426 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 1427 | Upto 35 sq. mm |
| 1428 | LED Down lighter (COB Type) (System lumenefficacy ≥120 lm/Watt ) |
| 1429 | Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 1430 | Powdercoateddiecast/Extruded aluminium Body including trim with Aluminium Reflector |
| 1431 | 12 -15 watt |
| 1432 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value, (CM/M/W) minimum as below, 350 RPM (tolerance asper IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 1433 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 1434 | Supplyof following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armoured (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) (Nicco/ Havells/PG/CCI/Polycab/Gloster/ Finolex make) |
| 1435 | 3 Core A2XFY |
| 1436 | 16.00 Sq.mm.3 & 1/2 Core U.G.armoured cable |
| 1437 | Supplying of followingA.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. |
| 1438 | High Speed 225 mm sweep(Havellsmake) |
| 1439 | A. 14. Estimate of Services Block |
| 1440 | CIVIL WORKS |
| 1441 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 1442 | All kinds of soil |
| 1443 | Supplying and filling in plinth with sandy soil under floors including, watering,ramming consolidating and dressing complete. |
| 1444 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 1445 | 1:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 1446 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 1447 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 1448 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 1449 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 1450 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 1451 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 1452 | Suspended floors, roofs, landings, balconies and access platform. |
| 1453 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 1454 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 1455 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 1456 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1457 | Brick work with Ist class common burnt clay F.P.S.(non modular) bricks in superstructure above plinth level upto floor V level in all shapes and sizes in : |
| 1458 | Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 1459 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 1460 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1461 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 1462 | 15 mm cement plaster on rough side of single or half brick wall of mix:- |
| 1463 | 1:4 (1 cement: 4 fine sand) |
| 1464 | 20 mm cement plaster of mix |
| 1465 | 1:4 (1 cement: 4 fine sand) |
| 1466 | 12 mm cement plaster of mix : |
| 1467 | 1:4 (1 cement: 4 fine sand) |
| 1468 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws. |
| 1469 | Local best quality Teak wood |
| 1470 | 35 mm thick |
| 1471 | EXTERIOR PAINTS |
| 1472 | Finishing walls with textured exterior paint of required shade |
| 1473 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 1474 | INTERIOR PAINTS |
| 1475 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications : |
| 1476 | Two or more coats applied @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @0.75 ltr/10 sqm. |
| 1477 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to preparethe surface even and smooth complete. |
| 1478 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 1479 | Water thinnable cement primer |
| 1480 | STEEL REINFORCEMENT |
| 1481 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level & above plinth level. |
| 1482 | Thermo-Mechanically Treated bars |
| 1483 | Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. |
| 1484 | Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. |
| 1485 | Hot finished welded type tubes |
| 1486 | Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishng to |
| 1487 | a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers,cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with :plete. |
| 1488 | 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part I, |
| 1489 | Polishing on wood work with ready made wax polish of approved brand and manufacture : |
| 1490 | New work |
| 1491 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 1492 | 0.63 mm thick with zinc coating not less than 275gm/sqm |
| 1493 | Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. |
| 1494 | 0.63mm thick with zinc coating not less than 275gm/m2 |
| 1495 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 1496 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters ,window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 1497 | Granite of any colour and shade |
| 1498 | Area of slab over 0.50 sqm. |
| 1499 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required. |
| 1500 | In grating, frames, guard bar, railing, brackets, gates and similar works. |
| 1501 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 1502 | 300x16 mm |
| 1503 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 1504 | 300x10 mm |
| 1505 | Providing and fixing aluminium handles, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 1506 | 125 mm |
| 1507 | Providing and fixing IS : 12817 marked stainless steel butt hinges with steelscrews etc. complete : |
| 1508 | 125x64x1.90 mm |
| 1509 | Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : |
| 1510 | Local best quality Teak wood |
| 1511 | Providing and fixing fibre cement high impact polypropylene reinforced roofing accessories in all colour with polymer coated J or L hooks,bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete: |
| 1512 | Barge boards |
| 1513 | Providing and fixing factory made uPVC white colour sliding glazed windowupto 1.50 m in height dimension comprising of uPVC multi-chamberedframe with in-built roller track and sash extruded profiles duly reinforcedwith 1.60 ± 0.2 mm thick galvanized mild steel section made from rollforming process of required length (shape & size according to uPVCprofile), appropriate dimension of uPVC extruded glazing beads anduPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (whitepowder coated) touch locks with hook, zinc alloy body with single nylonrollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mmsize for fixing frame to finished wall and necessary stainless steel screwsetc. Profile of frame & sash shall be mitred cut and fusion welded at allcorners, including drilling of holes for fixing hardware\"s and drainage ofwater etc. After fixing frame the gap between frame and adjacent finishedwall shall be filled with weather proof silicon sealent over backer rod ofrequired size and of approved quality, all complete as per approveddrawing & direction of Engineer-in-Charge. (Single / double glass panes,wire mesh and silicon sealent shall be paid separately). Variation inprofile dimension in higher side shall be accepted but no extra paymenton this account shall be made. |
| 1514 | Note: For uPVC frame and sash extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. |
| 1515 | Three track three panels sliding window made of (big series)frame 116 x 45 mm & sash 46 x 62 mm both having wallthickness of 2.3 ± 0.2 mm and single glazing bead / doubleglazing bead of appropriate dimension. (Area of windowabove 1.75 sqm) |
| 1516 | B. Plumbing Work |
| 1517 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 1518 | Rectangular shape 1500x450 mm |
| 1519 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 1520 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 1521 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 1522 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. |
| 1523 | Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms |
| 1524 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 1525 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 1526 | 15 mm nominal bore |
| 1527 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: |
| 1528 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P.brass pillar taps |
| 1529 | Providing and fixing PTMT pillar cock of approved quality and colour. |
| 1530 | 15 mm nominal bore, 80 mm long, weighing not less than 46 gms |
| 1531 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge |
| 1532 | Concealed work, including cutting chases and making good the wall etc. |
| 1533 | 15 mm nominal outer dia Pipes |
| 1534 | 25 mm nominal outer dia Pipes |
| 1535 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 1536 | External work |
| 1537 | 65 mm nominal outer dia Pipes |
| 1538 | 100 mm nominal outer dia Pipes |
| 1539 | INTERNAL ELECTRICAL WORKS |
| 1540 | Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 1541 | Group A |
| 1542 | Group B |
| 1543 | Group C |
| 1544 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loopearthing as required. |
| 1545 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 1546 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 1547 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 1548 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 1549 | 25 mm |
| 1550 | 32 mm |
| 1551 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 1552 | 5/6 A switch |
| 1553 | 3 pin 5/6 A socket outlet |
| 1554 | Telephone socket outlet |
| 1555 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 1556 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 1557 | 1 or 2 Module (75mmX75mm) |
| 1558 | 4 Module (125mmX75mm) |
| 1559 | 8 Module (125mmX125mm) |
| 1560 | 12 Module (200mmX150mm) |
| 1561 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required |
| 1562 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 1563 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 1564 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 1565 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 1566 | 8 way , Double door |
| 1567 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 1568 | Single pole |
| 1569 | Double pole |
| 1570 | Supplying and fixing single pole blanking plate in the existingMCB DB complete etc. as required. |
| 1571 | Earthing with copper earth plate 600 mm X 600 mm X3 mm thick including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 1572 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brassnut bolt & spring washer spaced at 50mm) |
| 1573 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 1574 | Upto 35 sq. mm |
| 1575 | Above 35 sq. mm and upto 95 sq. mm |
| 1576 | LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 withdriver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range-5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not riseabove 90°C). |
| 1577 | 18- 22 Watt |
| 1578 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value, (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 1579 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 1580 | Supplyof following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armoured (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . |
| 1581 | 3 Core A2XFY |
| 1582 | 16.00 Sq.mm.3 & 1/2 Core U.G.armoured cable |
| 1583 | 95.00 Sq.mm.3 & 1/2 Core U.G.armoured cable |
| 1584 | Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical indoor type floor/wall mounting compartmentalize panel board of size 1.45M X 1.55MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and35mm X 35mm X 5mm size angle having 4 no legs at the bottom. The panel board is to be erected in 1 : 3 : 6 PCC foundation including brick soling / grouting etc. complete neatly Wiring done with provision for one no 315A 4pole MCCB or Switch Fuse Unit as incomer and provision for 8nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items: 1. 30mm X 5mm 4 strip copper Bus - Bar 1.45 M length each i20mm X 3mm 4 strip copper Bus-Bar 0.5M each 8sets 2. Digital 3 Phase Voltmeter Accuracy class 0.5- 1 no 3. Digital 3 Phase Ammeter Accuracy class 0.5- 1 no 4. Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 no 5. Voltmeter & Ammeter Selector Switch- 2 no 6. 2 A Slide fuse unit - 3nos |
| 1585 | A. 15. Estimate of Bird Watch Tower |
| 1586 | CIVIL WORKS |
| 1587 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 1588 | All kinds of soil |
| 1589 | Supplying and filling in plinth with sandy soil under floors including, watering,ramming consolidating and dressing complete. |
| 1590 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 1591 | 1:3:6 ( 1 Cement: 3coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 1592 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 1593 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 1594 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 1595 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 1596 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 1597 | Suspended floors, roofs, landings, balconies and access platform. |
| 1598 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 1599 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 1600 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 1601 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1602 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 1603 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1604 | 15 mm cement plaster on rough side of single or half brick wall of mix:- |
| 1605 | 1:4 (1 cement: 4 fine sand) |
| 1606 | EXTERIOR PAINTS |
| 1607 | Finishing walls with textured exterior paint of required shade : |
| 1608 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 1609 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to preparethe surface even and smooth complete. |
| 1610 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 1611 | Water thinnable cement primer |
| 1612 | STEEL REINFORCEMENT |
| 1613 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level & above plinth level. |
| 1614 | Thermo-Mechanically Treated bars |
| 1615 | Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. |
| 1616 | Hot finished welded type tubes |
| 1617 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 1618 | 0.63 mm thick with zinc coating not less than 275gm/sqm |
| 1619 | Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. |
| 1620 | 0.63mm thick with zinc coating not less than 275gm/m2 |
| 1621 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters ,window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 1622 | Granite of any colour and shade |
| 1623 | Area of slab over 0.50 sqm. |
| 1624 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 1625 | Providing and fixing fibre cement high impact polypropylene reinforced roofing accessories in all colour with polymer coated J or L hooks,bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete: |
| 1626 | Barge boards |
| 1627 | Applying priming coat:- |
| 1628 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works:- |
| 1629 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications : |
| 1630 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 1631 | Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishng to |
| 1632 | a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers,cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 1633 | 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part I, |
| 1634 | A. 16. i) Estimate of Trekking Route Development |
| 1635 | CIVIL WORKS |
| 1636 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 1637 | All kinds of soil |
| 1638 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 1639 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 1640 | STEEL REINFORCEMENT |
| 1641 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. |
| 1642 | Thermo-Mechanically Treated bars |
| 1643 | FORM WORK |
| 1644 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 1645 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 1646 | Providing and laying factory made chamfered edge Cement Concretepaver blocks of M-30 grade in footpath, parks, lawns, drive ways or light trafficparking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per requiredsize and pattern, finishing and sweeping extra sand. complete all asper direction of Engineer-in-Charge. |
| 1647 | 80 mm thick |
| 1648 | Granular Sub-Base with Close Graded Material (Table:- 400-1) |
| 1649 | Plant Mix Method Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant atOMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve thedesired density, complete as per clause 401 . |
| 1650 | Grading-I Material |
| 1651 | ii) Estimate of Intermediate Resting Shed - 5 Nos |
| 1652 | CIVIL WORKS |
| 1653 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 1654 | All kinds of soil |
| 1655 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 1656 | 1:3:6 ( 1 Cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 1657 | Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with : |
| 1658 | Cement mortar 1:6(1 cement: 6 coarse sand) |
| 1659 | Pointing on stone work with cement mortar 1:3 (1 cement :3 fine sand):: |
| 1660 | Raised and cut pointing. |
| 1661 | Pre Fabricated Wooden Gazebo |
| 1662 | A. 17. Estimate of Parking |
| 1663 | CIVIL WORKS |
| 1664 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 1665 | All kinds of soil |
| 1666 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 1667 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 1668 | STEEL REINFORCEMENT |
| 1669 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. |
| 1670 | Thermo-Mechanically Treated bars |
| 1671 | FORM WORK |
| 1672 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 1673 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 1674 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer. |
| 1675 | M.S. tube |
| 1676 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications : |
| 1677 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 1678 | Providing and laying factory made chamfered edge Cement Concretepaver blocks of M-30 grade in footpath, parks, lawns, drive ways or light trafficparking etc, of required strength, thickness & size/ shape, made bytable vibratory method using PU mould, laid in required colour &pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sandbedding layer through vibratory compaction by using plate vibrator,filling the joints with sand and cutting of paver blocks as per requiredsize and pattern, finishing and sweeping extra sand. complete all asper direction of Engineer-in-Charge. |
| 1679 | 80 mm thick |
| 1680 | Granular Sub-Base with Close Graded Material(Table:- 400-1) |
| 1681 | Plant Mix Method Construction of granular sub-base by providing closegraded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 . |
| 1682 | Grading-I Material |
| 1683 | Cutting road and making good the same including supply of extraquantities of materials i.e. aggregate, moorum screening, red bajriand labour required |
| 1684 | Water bound macadam |
| 1685 | Preparation and consolidation of sub grade with power road roller of8 to 12 tonne capacity after excavating earth to an average of 22.5cm depth, dressing to camber and consolidating with road rollerincluding making good the undulations etc. and re-rolling the subgrade and disposal of surplus earthwith lead upto 50 metres. |
| 1686 | A. 18. Estimate of Boundary Wall |
| 1687 | CIVIL WORKS |
| 1688 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 1689 | All kinds of soil |
| 1690 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 1691 | 1:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 1692 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 1693 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 1694 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 1695 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 1696 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 1697 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 1698 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 1699 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 1700 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1701 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 1702 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1703 | 15 mm cement plaster on rough side of single or half brick wall of mix:- |
| 1704 | 1:4 (1 cement: 4 fine sand) |
| 1705 | EXTERIOR PAINTS |
| 1706 | Finishing walls with textured exterior paint of required shade : |
| 1707 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 1708 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to preparethe surface even and smooth complete. |
| 1709 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 1710 | Water thinnable cement primer |
| 1711 | STEEL REINFORCEMENT |
| 1712 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level & above plinth level. |
| 1713 | Thermo-Mechanically Treated bars |
| 1714 | Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. |
| 1715 | Hot finished welded type tubes |
| 1716 | Applying priming coat:- |
| 1717 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works:- |
| 1718 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications : |
| 1719 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 1720 | A. 19. Estimate of Approach Road |
| 1721 | CIVIL WORKS |
| 1722 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 1723 | All kinds of soil |
| 1724 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 1725 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 1726 | STEEL REINFORCEMENT |
| 1727 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. |
| 1728 | Thermo-Mechanically Treated bars |
| 1729 | FORM WORK |
| 1730 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 1731 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 1732 | Providing and laying factory made chamfered edge Cement Concretepaver blocks of M-30 grade in footpath, parks, lawns, drive ways or light trafficparking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per requiredsize and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.: |
| 1733 | 80 mm thick |
| 1734 | Granular Sub-Base with Close Graded Material (Table:- 400-1) |
| 1735 | Plant Mix MethodConstruction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreadingin uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve thedesired density, complete as per clause 401 . |
| 1736 | Grading-I Material |
| 1737 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required |
| 1738 | Water bound macadam |
| 1739 | Prepration and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road rollerincluding making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 1740 | A. 20. Estimate of Landscaping including Internal Pathways |
| 1741 | CIVIL WORKS |
| 1742 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 1743 | All kinds of soil |
| 1744 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 1745 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 1746 | STEEL REINFORCEMENT |
| 1747 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. |
| 1748 | Thermo-Mechanically Treated bars |
| 1749 | FORM WORK |
| 1750 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 1751 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 1752 | Providing and laying factory made chamfered edge Cement Concretepaver blocks of M-30 grade in footpath, parks, lawns, drive ways or light trafficparking etc, of required strength, thickness & size/ shape, made bytable vibratory method using PU mould, laid in required colour &pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sandbedding layer through vibratory compaction by using plate vibrator,filling the joints with sand and cutting of paver blocks as per requiredsize and pattern, finishing and sweeping extra sand. complete all asper direction of Engineer-in-Charge. |
| 1753 | 80 mm thick |
| 1754 | Granular Sub-Base with Close Graded Material(Table:- 400-1) |
| 1755 | Plant Mix MethodConstruction of granular sub-base by providing closegraded Material, mixing in a mechanical mix plant atOMC, carriage of mixed Material to work site, spreadingin uniform layers with motor grader on prepared surfaceand compacting with vibratory power roller to achieve thedesired density, complete as per clause 401 . |
| 1756 | Grading-I Material |
| 1757 | LANDSCAPING |
| 1758 | Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mmthickness of existing ground prepared with proper level and ramming withtools wooden (Dhurmos) and than rolling the surface with light roller makethe surface smoothen and light waterning with sprinkler and maintenancefor 30 days or more till the grass establish properly, as per direction ofofficer-in-charge. |
| 1759 | Providing Circular Cement Concrete pots of specified size, cast with cementconcrete of nominal mix 1:2:4 (1 cement: 2 coarse sand: 4 graded stoneaggregate 6 mm nominal size), reinforced with 7 Nos ( 3 nos horizontal &4 nos vertical “ U “ shape) M.S. wires of 3.5 mm dia as per design, includingrequired form work, finishing with cement punning on exposed surface,curing for specified period and stacking in required rows & height, allcomplete as per direction of Officer-in-charge. |
| 1760 | Top inside dia 30 cm, outer bottom dia 20 cm, total height 30 cmwith wall thickness of 25.4 mm |
| 1761 | Providing and Displaying of Aglaonema Sam plant ht.30 cm well developedthree in one, having 18 to 20 fresh, healthy and attractive colorful leaves in35 cm size Earthen pot/Chali/Tray & as per direction of the officer-in-charge. |
| 1762 | Providing and displaying of Araucaria cookie having ht. 1.80 m to 1.95 m,straight, well developed, fresh and healthy with lush green leaves frombottom to top in 30 cm size of Earthen pot/Plastic pot & as per directionof the officer-in-charge. |
| 1763 | Providing and displaying of Areca Palm having ht. 2.40 m to 2.70 m with 12to 14 suckers, well developed, fresh and healthy with lush green foliage in35 cm size of Bucket type cement pots & as per direction of theofficer-in-charge. |
| 1764 | Providing and displaying of Croton Petra Bangalore (Specimen ) varietyhaving ht. 60 cm to 75 cm with 4 to 6 branches, well developed, fresh &healthy foliage approximately 60-65 leaves in 30 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. |
| 1765 | TREE PLANTS |
| 1766 | Providing and stacking of Bottle palm of ht. 270-300 cm bottom girth 40-50cm well developed in big HDPE bags as per direction of the officer-in-charge.Each |
| 1767 | Providing and stacking of Fishtail palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big size HDPE bags as per direction of theofficer-in-charge. |
| 1768 | Providing and stacking of Foxtail palm of ht. 180-210 cm bottom girth 25-30 cm well developed in big size HDPE bags as per direction of theofficer-in-charge. |
| 1769 | Providing and stacking of Foxtail palm of ht. 240-270 cm bottom girth 35-40 cm well developed in big size HDPE bags as per direction of theofficer-in-charge. |
| 1770 | Providing and stacking of Magnolia grandiflora of height 150-165 cm. in bigpoly bag of size 25 cm as per direction of the officer-in-charge.v |
| 1771 | Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm.with 3-4 branches and thick stem in big size HDPE bags as per directionof the officer-in-charge. |
| 1772 | SHRUBS |
| 1773 | Providing and stacking of Ficus blackii (F.vivion) (bushy) of height 150-165cm. with 8-10 branches and healthy foliage in earthen pots of size 30cm as per direction of the officer-in-charge. |
| 1774 | Providing and stacking of Ficus panda of height 60-90 cm, with 8-10branches, and healthy foliage, bushy in big size HDPE bag as per directionof the officer-in-charge. |
| 1775 | Providing and stacking of Ficus panda of height 90-105 cm. with 10-12branches and healthy foliage, well formed in cement pots of size 30 cm asper direction of the officer-in-charge. |
| 1776 | Providing and stacking of Hibiscus variegated of height 60-75 cm. with 8-10 branches and healthy variegated foliage in cement pots of size 35 cmas per direction of the officer-in-charge. |
| 1777 | Providing and stacking of Thuja compacta of height 75-90 cm., conicalshaped, well formed with healthy foliage in earthen pots of size 30 cm asper direction of the officer-in-charge. |
| 1778 | A. 21. Estimate of Entrance Gate |
| 1779 | CIVIL WORKS |
| 1780 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 1781 | All kinds of soil |
| 1782 | Supplying and filling in plinth with sandy soil under floors including, watering,ramming consolidating and dressing complete. |
| 1783 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 1784 | 1:3:6 ( 1 Cement: 3coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 1785 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 1786 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 1787 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 1788 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 1789 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 1790 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 1791 | Suspended floors, roofs, landings, balconies and access platform. |
| 1792 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 1793 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 1794 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 1795 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1796 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 1797 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1798 | 12 mm cement plaster of mix : |
| 1799 | 1:4 (1 cement: 4 fine sand) |
| 1800 | EXTERIOR PAINTS |
| 1801 | Finishing walls with textured exterior paint of required shade : |
| 1802 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 1803 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 1804 | Water thinnable cement primer |
| 1805 | STEEL REINFORCEMENT |
| 1806 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level & above plinth level. |
| 1807 | Thermo-Mechanically Treated bars |
| 1808 | Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. |
| 1809 | Hot finished welded type tubes |
| 1810 | Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishng to |
| 1811 | a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers,cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 1812 | 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part I, |
| 1813 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 1814 | 0.63 mm thick with zinc coating not less than 275gm/sqm |
| 1815 | Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. |
| 1816 | 0.63mm thick with zinc coating not less than 275gm/m2 |
| 1817 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement [email protected] kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 1818 | Double charge vitrified tile polished finish of size |
| 1819 | Size of Tile 600 x 600 mm |
| 1820 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 1821 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters ,window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 1822 | Granite of any colour and shade |
| 1823 | Area of slab over 0.50 sqm. |
| 1824 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 1825 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required. |
| 1826 | In grating, frames, guard bar, railing, brackets, gates and similar works. |
| 1827 | INTERNAL ELECTRICAL WORKS |
| 1828 | Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 1829 | Group A |
| 1830 | Group B |
| 1831 | Group C |
| 1832 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 1833 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 1834 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 1835 | 25 mm |
| 1836 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 1837 | 5/6 A switch |
| 1838 | 3 pin 5/6 A socket outlet |
| 1839 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 1840 | 12 Module (200mmX150mm) |
| 1841 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 1842 | 6 way , Double door |
| 1843 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 1844 | Single pole |
| 1845 | Double pole |
| 1846 | Supplying and fixing single pole blanking plate in the existingMCB DB complete etc. as required. |
| 1847 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 1848 | Upto 35 sq. mm |
| 1849 | LED Down lighter (COB Type) (System lumenefficacy ≥120 lm/Watt ) |
| 1850 | Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 1851 | Powdercoateddiecast/Extruded aluminium Body including trim with Aluminium Reflector |
| 1852 | 12 -15 watt |
| 1853 | 22 watt |
| 1854 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value, (CM/M/W) minimum as below, 350 RPM (tolerance asper IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 1855 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 1856 | Supplyof following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armoured (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . |
| 1857 | 10 00 Sq.mm 3 Core U.G.armoured cable |
| 1858 | A. 22. Estimate of Compound Illumination |
| 1859 | Supply with installation and commissioning of HAVELLS-ALL-IN-ONE SOLAR STREET LIGHT (30 WATT) WITH 7 METER POLE HEIGHT -All in one (AIO) Solar street light with high efficiency mono crystalline solar PV module, lithium ferro phosphate battery with in-built BMS technology, High Efficacy LED, MPPT Solar charge controller and aluminium extruded body. PIR motion Sensor for automatic controlling of dimming and brightness of light, which increase the backup time |
| 1860 | Havells VILLA solar gate/boundary wall light with inbuilt high efficency poly-crystalline solar module and maintenance free lithium battery with expected life of 1000 cycle and backup for two days and high efficiency long life LED housed in elegant looking die cast aluminium body with IP65 protection. |
| 1861 | Havells ‐FLORIO Solar Post Top Light (20 W) with inbuilt high efficency poly‐crystalline solar module and maintenance free lithium battery with expected life of 1000 cycle and backup for three days and high efficiency long life LED housed in elegant looking diecast aluminium body with IP65 protection. (including pole of length 3.5 meter). |
| 1862 | Havells ‐ BUDZ solar bollard light (1W) with inbuilt high efficency poly‐crystalline solar module and maintenance free lithium battery with expected life of 1000 cycle and backup for two days and high efficiency long life LED housed in elegant looking diecast aluminium body with IP65 protection. |
| 1863 | A. 23. Estimate of Site Development & Retaining Wall |
| 1864 | RETAINING WALL |
| 1865 | CIVIL WORKS |
| 1866 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 1867 | All kinds of soil |
| 1868 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 1869 | 1:3:6 ( 1 Cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 1870 | Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with : |
| 1871 | Cement mortar 1:6(1 cement: 6 coarse sand) |
| 1872 | Pointing on stone work with cement mortar 1:3 (1 cement :3 fine sand): |
| 1873 | Raised and cut pointing. |
| 1874 | A. 24. Estimate of RO Plant & Waste Management System |
| 1875 | R.O. Plant 1000 Liters / Hr |
| 1876 | WASTE MANAGEMENT |
| 1877 | Outdoor Twin Waste Bins, of capacity 120 |
| 1878 | FROSTY mobile container 1000 ltr (for Class B) Normal Type |
| 1879 | A. 25. Estimate of Signages |
| 1880 | Providing and installation of Retro-Reflectrorised Mandatory /Regulatory/ Informatory sign as per IRC: 67-2012 made of Omni Cube reflective sheeting Type XI(Make Avery Dennison or Equivalent) with Traffic Jet or equivalentReflective Printing vide clause 801.3 of MORTH, fixed over Aluminium composite material 3.20 mm thick fixed on SS (304Grade)square frame of size25x25x3 mm supported on SS(304 Grade)complete as per drawing and as per technical specification clause 801. 15 Years\" Warranty will be Provided on the Reflective Material in Type XI by the Manufacturer of Reflective Sheeting. The Ink used for printing on the all Logos/ Images in Sign Boards should be of the same make as of that of the Retro Reflective Sheeting Manufacturer. Reflective Sheeting Test Result and IRC Accreditation of Trafficjet Digital Printer or equivalent shouid be submitted having attested by OEM. |
| 1881 | 2400 mm x 1200 mm (To be installed by 2 Posts of length 3900 mm above ground level firmly fixed to the ground by means of properly designed depth of foundation with M15 grade cement concrete 60cmX60cmX90cm and painting etc. completed as per direction . ) |
| 1882 | 1800 mm x 1200 mm (To be installed by 2 Posts of length 3900 mm above ground level firmly fixed to the ground by means of properly designed depth of foundation with M15 grade cement concrete 60cmX60cm X90 cm complete. ) |
| 1883 | 1200 mmx 900 mm (To be installed by 1 Post of length 3600 mm above ground level firmly fixed to the ground by means of properly designed depth of foundation with M15 grade cement concrete 45cmX45cmX75cm and painting etc. completed as per direction . ) |
| 1884 | 800 mm x 600 mm (To be installed by 1 Post of length 3300 mm above ground level firmly fixed to the ground by means of properly designed depth of foundation with M15 grade cement concrete 45cmX45cmX75cm and painting etc. completed as per direction . ) |
| 1885 | A. 26. i) Estimate of Sub-Station Equipment & D.G. Set |
| 1886 | DELHI SCHEDULE OF RATES (E&M) (Volume-II) 2025 |
| 1887 | Supply, installation, testing and commissioning offollowing capacity (continuous loading) BEE 5 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, ONAN (Oil Natural Air Natural) copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better, suitable for out door/indoor applications with Offload Tap Changer/ On Load Tap Changer (OLTC) ( below 500 KVA offload and above 500 KVA On Load Tap Changer) on HV side havingAVR relay and Remote Tap Changer Control (RTCC)for automatic sensing of incoming voltage, automatic operation of OLTC andfacility for remote and manual operation of OLTC HV sidein range of +5% to -15% in steps of2.5%, having cable end boxes on HV side suitable fo |
| 1888 | 3x300 sqmm XLPE cable of 11 KV grade, including bus trunking arrangement on LV side including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as perrelevant IS Code including first filling of filtered dehydratedoil,i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 and duly ISI Marked and as per CPWD specifications complete in all respectsetc as required at site. The maximum flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux density with + 12.5 percent combined voltage and frequency variation from rated voltage and frequency does not exceed 1.9 Tesla. The permissible temperature-rise shall not exceed 35 dg.C for oil and 40 dg. C up to 200 KVA and 40 dg.C for oil and 45 dg. C for above 200 KVA for winding. Inside of tank shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shall be used. IS: 1180 (Part 3)shall be referred to for paint thickness for normal to medium corrosive atmosphere. For highly polluted atmosphere and special application external paint work shall be as per direction of Engineer-in-Charge. Design ambient condition : a) air temperature 50 deg C,b) Relative Humidity 90 % Max,c) Seismic Zone as per location of site, d) Altitude as per location/site. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA standard. The transformer should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location etc. Marking Each transformer shall be provided with rating plate made of anodizedaluminum/ stainless steel material securely fixed on the outer body, easily accessible,as per IS: 1180 Part-3. The entries on the rating plate shall be indelibly marked. |
| 1889 | Fitting and Accessories :The followingfittings shall be provided:-a) Two earthing terminals with the earthing symbol b) Oil level gauge indicating oil level at minimum, 30°C and maximum operating temperature;c) Air release device (for non-sealed type transformers) d) Rating and terminal marking plates; e) Silica gel breather f) Drain-cum-sampling valve (¾″ nominal size thread, IS 554) preferably steel with plug for three phase transformers; g) Thermometer pocket with cap; h) Oil filling holes having (1¼″ nominal size thread) with cover (for sealed type transformers without conservator); i) Lifting lugs for the complete transformer as well as for core and winding assembly; |
| 1890 | j) Pressure relief device or explosion vent above 200 kVA;k) One filter valve on the upper side of the tank (for transformers above 200 kVA); l) Unidirectional flat rollers (for transformers above 200 kVA); m) Inspection hole (for transformers above 200 kVA); n) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); o) Buchholz relay for transformers above 800 kVA. p) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. q) Bird guard; r) Oil temperature indicator and winding temperature indicators for transformers |
| 1891 | above 200 kVA with suitable tripping mechanism above permissible limit s) Jacking pads (for transformer above 1600 kVA); t) Additional Neutral separately brought out on bushing for earthing. u) Magnetic oil level gauge (for transformer above 1600 kVA) with low oil level alarm contact; v) Non return valve (for conducting pressure test); w) Pressure relief device or explosion vent x). Monogram Plate y) Inspection cover z). Detachable type radiators with top and bottom shutoff valve. aa) Oil Conservator with Oil level indicator, minimum level marking and drain plug for all transformers of capacity 50 KVA and above. bb)Necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers. |
| 1892 | 315 KVA |
| 1893 | Supply, installation, Testing & Commissioning of \"Silent Type Diesel Generating set as per CPCBIV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications,should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc.and consisting of the followings: |
| 1894 | (A) Diesel Engine: Turbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWDspecifications. (B) Engine mounted Instrument Panel fitted with and having digital display for following:Start-stop switch with key Water temperature indication Lubrication oil pressure indication Lubrication oil temperature indication Battery charging indication and Voltage indication RPM indication Over speed indication Low lubricantion Oil trip indication Engine Running Hours indication Fuel Level |
| 1895 | (C) Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation. |
| 1896 | (D) Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. E) FUEL TANK: Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class \"C\" pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. (F) Exhaust System: Dry exhaust manifold with hospitaltype exhaust silencer and catalytic convertor. |
| 1897 | (G) Starting System:12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acidSMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set. |
| 1898 | (H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCBIV + or better norms etc. and as per CPWD specifications. |
| 1899 | (I) AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminum) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM makeetc. as per approved by Engineering in charge and including the following: 1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip. 2. Auto/Manual/Test/Off selector switch3.Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay). |
| 1900 | 4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering 5.Energy analyser unit to indicate current, Voltage( L-N & L-L), kW, kVA (Phase & Total), Frequency, KWH, PF.6.LED Indicating lamps for load on mains and load on set. 7.Fuse/ MCB for instruments. 8.Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment. 9.Main supply failure monitor. 10.Supply failure timer. 11.Restoration timer 12.Control unit with three impulse automatic engine start/stop and failure to start lockout. 13.Impulse counter with locking and reset facility. 14.ON/OFF/Control circuit switch with indicator |
| 1901 | 15.Audio/Video annunciation for (i)High water temperature (ii)Low lubricating oil pressure (iii)Engine over speed (iv)Engine fails to start (v)Full load/maximum load warning 16.Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories 17.Maintenance notification based on Engine Run Hour & due date. 18.Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring. |
| 1902 | 100KVA |
| 1903 | Connecting Armoured Cable and Switch Gears |
| 1904 | A. 26. ii) Estimate of Furniture & Furnishing |
| 1905 | Furniture & Furnishing |
| 1906 | Sub-Head:- A. 26. iii) Estimate of CCTV System |
| 1907 | CCTV System |
| 1908 | A. 27. i) Estimate of Festival Ground - Performance Ground Improvement at Bakshi Festival Groundm |
| 1909 | CIVIL WORKS |
| 1910 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 1911 | All kinds of soil |
| 1912 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 1913 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 1914 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level & above plinth level. |
| 1915 | Thermo-Mechanically Treated bars |
| 1916 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 1917 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 1918 | Providing and laying factory made chamfered edge Cement Concrete paver blocks of M-30 grade in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. |
| 1919 | 80 mm thick |
| 1920 | Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. |
| 1921 | Hot finished welded type tubes |
| 1922 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications : |
| 1923 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 1924 | Granular Sub-Base with Close Graded Material (Table:- 400-1) |
| 1925 | Plant Mix Method Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 . |
| 1926 | Grading-I Material |
| 1927 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajriand labour required |
| 1928 | Water bound macadam |
| 1929 | A. 27. ii) Estimate of Boundary Wall at Bakshi Ground |
| 1930 | CIVIL WORKS |
| 1931 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 1932 | All kinds of soil |
| 1933 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 1934 | 1:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 1935 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 1936 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 1937 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 1938 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 1939 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 1940 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 1941 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 1942 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 1943 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1944 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 1945 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1946 | 15 mm cement plaster on rough side of single or half brick wall of mix:- |
| 1947 | 1:4 (1 cement: 4 fine sand) |
| 1948 | EXTERIOR PAINTS |
| 1949 | Finishing walls with textured exterior paint of required shade : |
| 1950 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 1951 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to preparethe surface even and smooth complete. |
| 1952 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 1953 | Water thinnable cement primer |
| 1954 | STEEL REINFORCEMENT |
| 1955 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level & above plinth level. |
| 1956 | Thermo-Mechanically Treated bars |
| 1957 | Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. |
| 1958 | Hot finished welded type tubes |
| 1959 | Applying priming coat:- |
| 1960 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works:- |
| 1961 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications : |
| 1962 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 1963 | PART B |
| 1964 | B. 1. Estimate of Amenities Block at Base of Phangrei Hill |
| 1965 | CIVIL WORKS |
| 1966 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 1967 | All kinds of soil |
| 1968 | Supplying and filling in plinth with sandy soil under floors including, watering,ramming consolidating and dressing complete. |
| 1969 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 1970 | 1:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 1971 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 1972 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 1973 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 1974 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 1975 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 1976 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 1977 | Suspended floors, roofs, landings, balconies and access platform. |
| 1978 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 1979 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 1980 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 1981 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1982 | Brick work with Ist class common burnt clay F.P.S.(non modular) bricks in superstructure above plinth level upto floor V level in all shapes and sizes in : |
| 1983 | Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 1984 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 1985 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1986 | 15 mm cement plaster on rough side of single or half brick wall of mix:- |
| 1987 | 1:4 (1 cement: 4 fine sand) |
| 1988 | 20 mm cement plaster of mix |
| 1989 | 1:4 (1 cement: 4 fine sand) |
| 1990 | 12 mm cement plaster of mix : |
| 1991 | 1:4 (1 cement: 4 fine sand) |
| 1992 | 12 mm cement plaster of mix :Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws. |
| 1993 | Local best quality Teak wood |
| 1994 | 35 mm thick |
| 1995 | EXTERIOR PAINTS |
| 1996 | Finishing walls with textured exterior paint of required shade : |
| 1997 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 1998 | INTERIOR PAINTS |
| 1999 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications : |
| 2000 | Two or more coats applied @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @0.75 ltr/10 sqm. |
| 2001 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to preparethe surface even and smooth complete. |
| 2002 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 2003 | Water thinnable cement primer |
| 2004 | STEEL REINFORCEMENT |
| 2005 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level & above plinth level. |
| 2006 | Thermo-Mechanically Treated bars |
| 2007 | Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. |
| 2008 | Hot finished welded type tubes |
| 2009 | Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishng to |
| 2010 | a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers,cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 2011 | 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part I, |
| 2012 | Polishing on wood work with ready made wax polish of approved brand and manufacture : |
| 2013 | New work |
| 2014 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 2015 | 0.63 mm thick with zinc coating not less than 275gm/sqm |
| 2016 | Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. |
| 2017 | 0.63mm thick with zinc coating not less than 275gm/m2 |
| 2018 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement [email protected] kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 2019 | Double charge vitrified tile polished finish of size |
| 2020 | Size of Tile 600 x 600 mm |
| 2021 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 2022 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters ,window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 2023 | Granite of any colour and shade |
| 2024 | Area of slab over 0.50 sqm. |
| 2025 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 2026 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required. |
| 2027 | In grating, frames, guard bar, railing, brackets, gates and similar works. |
| 2028 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 2029 | 300x16 mm |
| 2030 | Providing and fixing aluminium handles, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 2031 | 125 mm |
| 2032 | Providing and fixing IS : 12817 marked stainless steel butt hinges with steelscrews etc. complete : |
| 2033 | 125x64x1.90 mm |
| 2034 | Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : |
| 2035 | Local best quality Teak wood |
| 2036 | Providing and fixing fibre cement high impact polypropylene reinforced roofing accessories in all colour with polymer coated J or L hooks,bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete: |
| 2037 | Barge boards |
| 2038 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chamberedframe with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from rollforming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finishedwall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra paymenton this account shall be made. |
| 2039 | Note: For uPVC frame and sash extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. |
| 2040 | Three track three panels sliding window made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) |
| 2041 | B. Plumbing Work |
| 2042 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. |
| 2043 | Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete |
| 2044 | 10 litre (full flush) capacity-coloured |
| 2045 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively withutomatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 2046 | One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 2047 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: |
| 2048 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P.brass pillar taps |
| 2049 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P.brass pillar taps |
| 2050 | Kitchen sink with drain board |
| 2051 | 510x1040 mm bowl depth 250 mm |
| 2052 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 2053 | Rectangular shape 1500x450 mm |
| 2054 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 2055 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 2056 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 2057 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. |
| 2058 | Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms |
| 2059 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 2060 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 2061 | Concealed work, including cutting chases and making good the wall etc. |
| 2062 | 15 mm nominal outer dia Pipes |
| 2063 | 20 mm nominal outer dia Pipes |
| 2064 | 25 mm nominal outer dia Pipes |
| 2065 | 32 mm nominal outer dia Pipes |
| 2066 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 2067 | 15 mm nominal bore |
| 2068 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 2069 | 15 mm nominal bore |
| 2070 | Providing and fixing PTMT pillar cock of approved quality and colour. |
| 2071 | 15 mm nominal bore, 80 mm long, weighing not less than 46 gms |
| 2072 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 2073 | External work |
| 2074 | 40 mm nominal outer dia Pipes |
| 2075 | 65 mm nominal outer dia Pipes |
| 2076 | 100 mm nominal outer dia Pipes |
| 2077 | INTERNAL ELECTRICAL WORKS |
| 2078 | Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 2079 | Group A |
| 2080 | Group B |
| 2081 | Group C |
| 2082 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loopearthing as required. |
| 2083 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 2084 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 2085 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 2086 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 2087 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 2088 | 20 mm |
| 2089 | 25 mm |
| 2090 | 32 mm |
| 2091 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 2092 | 5/6 A switch |
| 2093 | 3 pin 5/6 A socket outlet |
| 2094 | Telephone socket outlet |
| 2095 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 2096 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 2097 | 1 or 2 Module (75mmX75mm) |
| 2098 | 4 Module (125mmX75mm) |
| 2099 | 6 Module (200mmX75mm) |
| 2100 | 8 Module (125mmX125mm) |
| 2101 | 12 Module (200mmX150mm) |
| 2102 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required |
| 2103 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 2104 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 2105 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 2106 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 2107 | Upto 450 mm sweep |
| 2108 | Supplying and fixing of following ways surface/ recessmounting, vertical type, 415 V, TPN MCB distribution board ofsheet steel, dust protected, duly powder painted, inclusive of200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 2109 | 12 way (4 + 36), Double door |
| 2110 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 2111 | Single pole |
| 2112 | Supplying and fixing single pole blanking plate in the existingMCB DB complete etc. as required. |
| 2113 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 2114 | 63 A |
| 2115 | Earthing with copper earth plate 600 mm X 600 mm X3 mm thick including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 2116 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brassnut bolt & spring washer spaced at 50mm) |
| 2117 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 2118 | Above 35 sq. mm and upto 95 sq. mm |
| 2119 | LED Down lighter (COB Type) (System lumenefficacy ≥120 lm/Watt ) |
| 2120 | Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 2121 | Powdercoateddiecast/Extruded aluminium Body including trim with Aluminium Reflector |
| 2122 | 12 -15 watt |
| 2123 | 18 watt |
| 2124 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value, (CM/M/W) minimum as below, 350 RPM (tolerance asper IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 2125 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 2126 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealedcopper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). |
| 2127 | Inverter Type - Cooling only |
| 2128 | 1.5 TRwith 5 Star BEE Rating |
| 2129 | Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET3 (Three Phase)with steel cable rope and submersible cable complete as directed and specified by the deptt. |
| 2130 | Three phase Submersible motor pump set(Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guarsuitable for 100 mm bore well and above. 3 HP STAGE 6 to 30 with MCB controlled Submersible motor pump setcontrol panel. |
| 2131 | Supplyof following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armoured (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . |
| 2132 | 3 & 1/2 Core A2XFY |
| 2133 | 50.00 Sq.mm.3 & 1/2 Core U.G.armoured cable |
| 2134 | 95.00 Sq.mm.3 & 1/2 Core U.G.armoured cable |
| 2135 | Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical indoor type floor/wall mounting compartmentalize panel board of size 1.45M X 1.55MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and35mm X 35mm X 5mm size angle having 4 no legs at the bottom. The panel board is to be erected in 1 : 3 : 6 PCC foundation including brick soling / grouting etc. complete neatly Wiring done with provision for one no 315A 4pole MCCB or Switch Fuse Unit as incomer and provision for 8nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items: 1. 30mm X 5mm 4 strip copper Bus - Bar 1.45 M length each i20mm X 3mm 4 strip copper Bus-Bar 0.5M each 8sets 2. Digital 3 Phase Voltmeter Accuracy class 0.5- 1 no 3. Digital 3 Phase Ammeter Accuracy class 0.5- 1 no 4. Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 no 5. Voltmeter & Ammeter Selector Switch- 2 no 6. 2 A Slide fuse unit - 3nos |
| 2136 | Supplying including installation, commissioning of Panel Board |
| 2137 | Supplying of followingA.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. |
| 2138 | High Speed 225 mm sweep(Havellsmake) |
| 2139 | Synthetic Thatch for Roofing |
| 2140 | B. 2. Estimate of Polycarbonate Dome Glamping Tent -10 Nos |
| 2141 | CIVIL WORKS |
| 2142 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 2143 | All kinds of soil |
| 2144 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 2145 | 1:3:6 ( 1 Cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 2146 | Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with : |
| 2147 | Cement mortar 1:6(1 cement: 6 coarse sand) |
| 2148 | Pointing on stone work with cement mortar 1:3 (1 cement :3 fine sand): |
| 2149 | Raised and cut pointing. |
| 2150 | Polycarbonate Dome Glamping Tent |
| 2151 | B. 3. Estimate of Tourist Amenities and Cafeteria |
| 2152 | CIVIL WORKS |
| 2153 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 2154 | All kinds of soil |
| 2155 | Supplying and filling in plinth with sandy soil under floors including, watering,ramming consolidating and dressing complete. |
| 2156 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 2157 | 1:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 2158 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 2159 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 2160 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 2161 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 2162 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 2163 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 2164 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 2165 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 2166 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 2167 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 2168 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 2169 | 12 mm cement plaster of mix : |
| 2170 | 1:4 (1 cement: 4 fine sand) |
| 2171 | STEEL REINFORCEMENT |
| 2172 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level & above plinth level. |
| 2173 | Thermo-Mechanically Treated bars |
| 2174 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters ,window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 2175 | Granite of any colour and shade |
| 2176 | Area of slab over 0.50 sqm. |
| 2177 | B. Plumbing Work |
| 2178 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 2179 | External work |
| 2180 | 65 mm nominal outer dia Pipes |
| 2181 | 100 mm nominal outer dia Pipes |
| 2182 | Earthing with copper earth plate 600 mm X 600 mm X3 mm thick including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 2183 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 2184 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). |
| 2185 | Inverter Type - Cooling only |
| 2186 | 1.5 TRwith 5 Star BEE Rating |
| 2187 | Supplyof following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armoured (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . |
| 2188 | 3 & 1/2 Core A2XFY |
| 2189 | 25.00 Sq.mm.3 & 1/2 Core U.G.armoured cable |
| 2190 | Wooden Log-Hut |
| 2191 | Synthetic Thatch for Roofing |
| 2192 | B. 4. Estimate of Hiking Track to Phangrei Lake |
| 2193 | CIVIL WORKS |
| 2194 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 2195 | All kinds of soil |
| 2196 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 2197 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 2198 | STEEL REINFORCEMENT |
| 2199 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. |
| 2200 | Thermo-Mechanically Treated bars |
| 2201 | FORM WORK |
| 2202 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 2203 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 2204 | Providing and laying factory made chamfered edge Cement Concrete paver blocks of M-30 grade in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. |
| 2205 | 80 mm thick |
| 2206 | Granular Sub-Base with Close Graded Material (Table:- 400-1) |
| 2207 | Plant Mix Method Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 . |
| 2208 | Grading-I Material |
| 2209 | B. 4. Estimate of Hiking Track to Phangrei Lake |
| 2210 | CIVIL WORKS |
| 2211 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 2212 | All kinds of soil |
| 2213 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 2214 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 2215 | STEEL REINFORCEMENT |
| 2216 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. |
| 2217 | Thermo-Mechanically Treated bars |
| 2218 | FORM WORK |
| 2219 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 2220 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 2221 | Providing and laying factory made chamfered edge Cement Concrete paver blocks of M-30 grade in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. |
| 2222 | 80 mm thick |
| 2223 | Granular Sub-Base with Close Graded Material (Table:- 400-1) |
| 2224 | Plant Mix Method Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 . |
| 2225 | Grading-I Material |
| 2226 | B. 5. Estimate of Panoramic View Watch Tower |
| 2227 | CIVIL WORKS |
| 2228 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 2229 | All kinds of soil |
| 2230 | Supplying and filling in plinth with sandy soil under floors including, watering,ramming consolidating and dressing complete. |
| 2231 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 2232 | 1:3:6 ( 1 Cement: 3coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 2233 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 2234 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 2235 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 2236 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 2237 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 2238 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 2239 | Suspended floors, roofs, landings, balconies and access platform. |
| 2240 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 2241 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 2242 | Stairs, (excluding landings) except spiral-staircases. |
| 2243 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 2244 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 2245 | Brick work with Ist class common burnt clay F.P.S.(non modular) bricks in superstructure above plinth level upto floor V level in all shapes and sizes in : |
| 2246 | Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 2247 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 2248 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 2249 | 15 mm cement plaster on rough side of single or half brick wall of mix:- |
| 2250 | 1:4 (1 cement: 4 fine sand) |
| 2251 | 20 mm cement plaster of mix |
| 2252 | 1:4 (1 cement: 4 fine sand) |
| 2253 | 12 mm cement plaster of mix : |
| 2254 | 1:4 (1 cement: 4 fine sand) |
| 2255 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws. |
| 2256 | Local best quality Teak wood |
| 2257 | 35 mm thick |
| 2258 | EXTERIOR PAINTS |
| 2259 | Finishing walls with textured exterior paint of required shade : |
| 2260 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 2261 | INTERIOR PAINTS |
| 2262 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications : |
| 2263 | Two or more coats applied @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @0.75 ltr/10 sqm. |
| 2264 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to preparethe surface even and smooth complete. |
| 2265 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 2266 | Water thinnable cement primer |
| 2267 | STEEL REINFORCEMENT |
| 2268 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level & above plinth level. |
| 2269 | Thermo-Mechanically Treated bars |
| 2270 | Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. |
| 2271 | Hot finished welded type tubes |
| 2272 | Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishng to |
| 2273 | a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers,cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 2274 | 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part I, |
| 2275 | Polishing on wood work with ready made wax polish of approved brand and manufacture : |
| 2276 | New work |
| 2277 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 2278 | 0.63 mm thick with zinc coating not less than 275gm/sqm |
| 2279 | Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. |
| 2280 | 0.63mm thick with zinc coating not less than 275gm/m2 |
| 2281 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 2282 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters ,window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 2283 | Granite of any colour and shade |
| 2284 | Area of slab over 0.50 sqm. |
| 2285 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 2286 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required. |
| 2287 | In grating, frames, guard bar, railing, brackets, gates and similar works. |
| 2288 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 2289 | 300x16 mm |
| 2290 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :: |
| 2291 | 300x10 mm |
| 2292 | Providing and fixing aluminium handles, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 2293 | 125 mm |
| 2294 | Providing and fixing IS : 12817 marked stainless steel butt hinges with steelscrews etc. complete : |
| 2295 | 125x64x1.90 mm |
| 2296 | Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : |
| 2297 | Local best quality Teak wood |
| 2298 | Providing and fixing fibre cement high impact polypropylene reinforced roofing accessories in all colour with polymer coated J or L hooks,bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete: |
| 2299 | Barge boards |
| 2300 | Applying priming coat:- |
| 2301 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works:- |
| 2302 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications : |
| 2303 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 2304 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 2305 | Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. |
| 2306 | Three track three panels sliding window made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) |
| 2307 | B. Plumbing Work |
| 2308 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. |
| 2309 | Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete |
| 2310 | 10 litre (full flush) capacity-coloured |
| 2311 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively withutomatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 2312 | One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 2313 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: |
| 2314 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 2315 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 2316 | Rectangular shape 1500x450 mm |
| 2317 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 2318 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 2319 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 2320 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. |
| 2321 | Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms |
| 2322 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 2323 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 2324 | Concealed work, including cutting chases and making good the wall etc. |
| 2325 | 15 mm nominal outer dia Pipes |
| 2326 | 20 mm nominal outer dia Pipes |
| 2327 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 2328 | 15 mm nominal bore |
| 2329 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 2330 | 15 mm nominal bore |
| 2331 | Providing and fixing PTMT pillar cock of approved quality and colour. |
| 2332 | 15 mm nominal bore, 80 mm long, weighing not less than 46 gms |
| 2333 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 2334 | External work |
| 2335 | 40 mm nominal outer dia Pipes |
| 2336 | 65 mm nominal outer dia Pipes |
| 2337 | 100 mm nominal outer dia Pipes |
| 2338 | INTERNAL ELECTRICAL WORKS |
| 2339 | Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as requiredS |
| 2340 | Group A |
| 2341 | Group B |
| 2342 | Group C |
| 2343 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required. |
| 2344 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 2345 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 2346 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 2347 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 2348 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 2349 | 25 mm |
| 2350 | 32 mm |
| 2351 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as require |
| 2352 | 5/6 A switch |
| 2353 | 3 pin 5/6 A socket outlet |
| 2354 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 2355 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 2356 | 4 Module (125mmX75mm) |
| 2357 | 6 Module (200mmX75mm) |
| 2358 | 8 Module (125mmX125mm) |
| 2359 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required |
| 2360 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 2361 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 2362 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 2363 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 2364 | Upto 450 mm sweep |
| 2365 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 2366 | 8 way , Double door |
| 2367 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 2368 | Single pole |
| 2369 | Double pole |
| 2370 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 2371 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 2372 | Upto 35 sq. mm |
| 2373 | LED Down lighter (COB Type) (System lumenefficacy ≥120 lm/Watt ) |
| 2374 | Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 2375 | Powdercoateddiecast/Extruded aluminium Body including trim with Aluminium Reflector |
| 2376 | 12 -15 watt |
| 2377 | Supplyof following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armoured (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) .ector |
| 2378 | 3 Core A2XFY |
| 2379 | 16.00 Sq.mm.3 & 1/2 Core U.G.armoured cable |
| 2380 | B. 6. Estimate of Boundary Wall |
| 2381 | CIVIL WORKS |
| 2382 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 2383 | All kinds of soil |
| 2384 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 2385 | 1:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 2386 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 2387 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 2388 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 2389 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 2390 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 2391 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 2392 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 2393 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 2394 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 2395 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: |
| 2396 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 2397 | 15 mm cement plaster on rough side of single or half brick wall of mix:- |
| 2398 | 1:4 (1 cement: 4 fine sand) |
| 2399 | EXTERIOR PAINTS |
| 2400 | Finishing walls with textured exterior paint of required shade : |
| 2401 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 2402 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to preparethe surface even and smooth complete. |
| 2403 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 2404 | Water thinnable cement primer |
| 2405 | STEEL REINFORCEMENT |
| 2406 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level & above plinth level. |
| 2407 | Thermo-Mechanically Treated bars |
| 2408 | Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. |
| 2409 | Hot finished welded type tubes |
| 2410 | Applying priming coat:- |
| 2411 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works:- |
| 2412 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications : |
| 2413 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 2414 | B. 7. Estimate of RO Plant & Waste Management |
| 2415 | R.O. Plant 1000 Liters / Hr |
| 2416 | WASTE MANAGEMENT |
| 2417 | Outdoor Twin Waste Bins, of capacity 120 |
| 2418 | FROSTY mobile container 1000 ltr (for Class B) Normal Type |
| 2419 | B. 8. Estimate of Compound Illumination |
| 2420 | Supply with installation and commissioning of HAVELLS-ALL-IN-ONE SOLAR STREET LIGHT (30 WATT) WITH 7 METER POLE HEIGHT -All in one (AIO) Solar street light with high efficiency mono crystalline solar PV module, lithium ferro phosphate battery with in-built BMS technology, High Efficacy LED, MPPT Solar charge controller and aluminium extruded body. PIR motion Sensor for automatic controlling of dimming and brightness of light, which increase the backup time |
| 2421 | Havells ‐FLORIO Solar Post Top Light (20 W) with inbuilt high efficency poly‐crystalline solar module and maintenance free lithium battery with expected life of 1000 cycle and backup for three days and high efficiency long life LED housed in elegant looking die cast aluminium body with IP65 protection. (including pole of length 3.5 meter). |
| 2422 | Havells ‐ BUDZ solar bollard light (1W) with inbuilt high efficency poly‐crystalline solar module and maintenance free lithium battery with expected life of 1000 cycle and backup for two days and high efficiency long life LED housed in elegant looking die cast aluminium body with IP65 protection. |
| 2423 | B. 9. Estimate of Signages |
| 2424 | Providing and installation of Retro-Reflectrorised Mandatory /Regulatory/ Informatory sign as per IRC: 67-2012 made of Omni Cube reflective sheeting Type XI(Make Avery Dennison or Equivalent) with Traffic Jet or equivalentReflective Printing vide clause 801.3 of MORTH, fixed over Aluminium composite material 3.20 mm thick fixed on SS (304Grade)square frame of size25x25x3 mm supported on SS(304 Grade)complete as per drawing and as per technical specification clause 801. 15 Years\" Warranty will be Provided on the Reflective Material in Type XI by the Manufacturer of Reflective Sheeting. The Ink used for printing on the all Logos/ Images in Sign Boards should be of the same make as of that of the Retro Reflective Sheeting Manufacturer. Reflective Sheeting Test Result and IRC Accreditation of Trafficjet Digital Printer or equivalent shouid be submitted having attested by OEM. |
| 2425 | 2400 mm x 1200 mm (To be installed by 2 Posts of length 3900 mm above ground level firmly fixed to the ground by means of properly designed depth of foundation with M15 grade cement concrete 60cmX60cmX90cm and painting etc. completed as per direction . ) |
| 2426 | 1800 mm x 1200 mm (To be installed by 2 Posts of length 3900 mm above ground level firmly fixed to the ground by means of properly designed depth of foundation with M15 grade cement concrete 60cmX60cm X90 cm complete. ) |
| 2427 | 1200 mmx 900 mm (To be installed by 1 Post of length 3600 mm above ground level firmly fixed to the ground by means of properly designed depth of foundation with M15 grade cement concrete 45cmX45cmX75cm and painting etc. completed as per direction . ) |
| 2428 | 800 mm x 600 mm (To be installed by 1 Post of length 3300 mm above ground level firmly fixed to the ground by means of properly designed depth of foundation with M15 grade cement concrete 45cmX45cmX75cm and painting etc. completed as per direction . ) |
| 2429 | B. 10. Estimate of Sub-Station Equipment & D.G. Set |
| 2430 | Supplying, installation, testing and commissioning of following capacity (continuous loading) BEE 5 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, ONAN (Oil Natural Air Natural) copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better, suitable for out door/indoor applications with Offload Tap Changer in range of +5% to -15% in steps of 2.5%, having cable end boxes on HV side suitable for 3x300 sqmm XLPE cable of 11 KV grade, including bus trunking arrangement on LV side including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant IS Code including first filling of filtered dehydrated oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 and as per CPWD specifications complete in all respects etc as required at site . The maximum flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux density with + 12.5 percent combined voltage and frequency variation from rated voltage and frequency does not exceed 1.9 Tesla. The permissible temperature-rise shall not exceed 35 0C for oil and 40 0C up to 200 KVA and 40 0C for oil and 45 0C for above 200 KVA for winding. Inside of tank |
| 2431 | shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shall be used. IS: 1180 (Part 3) shall be referred to for paint thickness for normal to medium corrosive atmosphere. For highly polluted atmosphere and special application external paint work shall be as per direction of Engineer-in-Charge. Design ambient condition : a) air temperature 500C, b) Relative Humidity 90 % Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA standard. The transformer should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location etc. Marking Each transformer shall be provided with rating plate made of anodized aluminium/ stainless steel material securely fixed on the outer body, easily accessible, as per IS: 1180Part-3. The entries on the rating plate shall beindelibly marked. |
| 2432 | Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Oil level gauge indicating oil level at minimum, 30°C and maximum operating temperature; c) Air release device (for non-sealed type transformers) d) Rating and terminal marking plates; e) Silica gel breather f) Drain-cum-sampling valve (¾″ nominal size thread, IS 554) preferably steel with plug for three phase transformers; g) Thermometer pocket with cap; h) Oil filling holes having (1¼″ nominal size thread) with cover (for sealed type transformers without conservator); |
| 2433 | i) Lifting lugs for the complete transformer as well as for core and winding assembly; j) Pressure relief device or explosion vent above 200 kVA; k) One filter valve on the upper side of the tank (for transformers above 200 kVA); l) Unidirectional flat rollers (for transformers above 200 kVA); m) Inspection hole (for transformers above 200 kVA); n) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); o) Buchholz relay for transformers above 800 kVA. p) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. q) Bird guard; r) Oil temperature indicator and winding temperature indicators for transformers above 200 kVA with |
| 2434 | suitable tripping mechanism above permissible limit s)Jacking pads (for transformer above 1 600 kVA); t)Additional Neutral separately brought out on bushing for earthing. u) Magnetic oil level gauge (for transformer above 1600 kVA) with low oil level alarm contact; v) Non return valve (for conducting pressure test); w) Pressure relief device or explosion vent x).Monogram Plate y) Inspection cover z). Detachable type radiators with top and bottom shutoff valve. aa) Oil Conservator with Oil level indicator, minimum levelmarking and drain plug for all transformers of capacity 50 KVA and above. bb) Necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers. |
| 2435 | 63 KVA |
| 2436 | Supply, installation, Testing & Commissioning of \"Silent Type Diesel Generating set as per CPCBIV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor,including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications,shouldhave QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc.and consisting of the followings: |
| 2437 | (A) Diesel Engine:Turbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous peration. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWDspecifications. (B) Engine mounted Instrument Panel fitted with and having digital display for following: Start-stop switch with keyWater temperature indicationLubrication oil pressure indicationLubrication oil temperature indicationBattery charging indication and Voltage indicationRPM indicationOver speed indicationLow lubricantion Oil trip indicationEngine Running Hours indicationFuel Level |
| 2438 | (C) Alternator:Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50%RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation. |
| 2439 | (D) Base Frame & Foundation:Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per commendations of manufacturer. E) FUEL TANK: Daily service fuel tank of suitable liters capacity as per CPWD Specifications,fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class \"C\" pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. (F) Exhaust System: Dry exhaust manifold with hospitaltype exhaust silencer and catalytic convertor. |
| 2440 | (G) Starting System:12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitablenumbers of batteries (180 AH capacity lead acidSMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set. |
| 2441 | (H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCBIV + or better norms etc. and as per CPWD specifications. |
| 2442 | (I) AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminum) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM makeetc. as per approved by Engineering in charge and including the following: 1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip. 2. Auto/Manual/Test/Off selector switch3.Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay). |
| 2443 | 4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering 5.Energy analyser unit to indicate current, Voltage( L-N & L-L), kW, kVA (Phase & Total), Frequency, KWH, PF.6.LED Indicating lamps for load on mains and load on set. 7.Fuse/ MCB for instruments. 8.Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment. 9.Main supply failure monitor. 10.Supply failure timer. 11.Restoration timer 12.Control unit with three impulse automatic engine start/stop and failure to start lockout. 13.Impulse counter with locking and reset facility. 14.ON/OFF/Control circuit switch with indicator |
| 2444 | 15.Audio/Video annunciation for (i)High water temperature (ii)Low lubricating oil pressure (iii)Engine over speed (iv)Engine fails to start (v)Full load/maximum load warning 16.Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories 17.Maintenance notification based on Engine Run Hour & due date. 18.Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring. |
| 2445 | 50 KVA |
| 2446 | Connecting Armoured Cable and Switch Gears |
| 2447 | Sub-Head:- B. 11. Estimate of CCTV System |
| 2448 | CCTV System |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy