| 1 | Replacement of following faulty SDFU switchesby new onesafter dismantlingthe old defective ones, i/cfixing, connection & testing etc. as required. |
| 2 | 125 Amps 415 volts TPN SDFU in Sheet steel enclosure with DIN type HRC fuses. (Make: L&K FN type, /Havells / Siemens) . |
| 3 | 250 Amps 415 volts TPN SDFUin Sheet steel enclosure with DIN type HRC fuses, confirming toIEC 60947-3, IS/IEC60947-3 . (Make: L&K FN type, /Havells / Siemens) . |
| 4 | Replacement of following faulty / damagedelectrical accessories/components by new one suitable for operation on 230 volt 50 hz AC Suppyi/c testing etc. as required. |
| 5 | 20/22 watt6500K LED Batten Polycarbonate/Aluminiumbody |
| 6 | Angle/batten Holder |
| 7 | Ceiling Rose |
| 8 | 18 watt 6500KLEDpanel (Round/Square) (Trim Clipon LED panel of Havells/SS) |
| 9 | Calling bell / buzzer ( Cona or s.s. make) |
| 10 | 63 Amps HRC fue with fuse holder & fuse base. (M/s L&T or s.s. make) |
| 11 | 15/16 Amps 250 volt 3 pin plug Top ( M/s Anchore /Cona/ or s.s. make) |
| 12 | 5/6Amps 250 Volts 3 pin Plug top ( M/s Anchore /Cona/ or s.s. make) |
| 13 | 25 mm dia PVC flexible pipe |
| 14 | Replacement of the burnt out wires /wirings by thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 15 | 2 x 1.5 sq. mm |
| 16 | 3 x 1.5 sq. mm |
| 17 | 4 x 1.5 sq. mm |
| 18 | 2 x 4 sq. mm |
| 19 | Replacement of damaged conduits by the following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 20 | 20mm |
| 21 | 25mm |
| 22 | Replacement of following damaged PVC casing caping ( ISI Marked) by the new onewith accessories in surface as required. |
| 23 | 20 X12 mm Size |
| 24 | 25X12 mm Size |
| 25 | Replacement offollowing damaged SPN/TPN typesheet steel, MCB distribution board by new one suitable for operation on 240V /415 V, 50 hz, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Make-Legrand/L&T/Siemens/Schneider) |
| 26 | 8 way, Double doortype SPN DB |
| 27 | 10 way, Double doorSPN DB |
| 28 | 12 way, Double doorSPN DB |
| 29 | Supply and fixing4 way (4 + 12) horizontal type 3 phase and neutralMCB distribution board of sheet steel, IP-43 with metal door, suitable for flush mounting and surface mounting, with 100Amps copper bus bar for each phase with neutral bar, earth bar and cable ties for cable management, fully insulated busbar & shrouded neutral bars, pre-fitted masking sheet, reversible door with provision for fixing four pole MCB/Isolator /RCCB/RCBO as incomer and SPMCB\"s as outgoing etc. as per IEC 61439-3 and grouting in wall as required.(Make: Legrand/ L&T / Schneider Electric/ Siemens/ ABB) |
| 30 | Replacement of modular type switch boards by following size/ modules, GI box (at least 1.2mm thick) along with modular base & cover plate for modular switches in recess etc. as required. |
| 31 | 1 or 2 Module (75 mmX75 mm) |
| 32 | 3 Module (100 mmX75 mm) |
| 33 | 6 Module (200 mmX75 mm) |
| 34 | 8 Module (125 mmX125 mm) |
| 35 | 12 Module (200 mmX150 mm) |
| 36 | Replacement of faulty switches and sockets byfollowing modular switch/ socket on the existing modular plate/switch box including connections but excluding modular plate etc. as required. |
| 37 | 10 A One way Modular switch (ISI) |
| 38 | 16/20A Modular switch (ISI) |
| 39 | 6 A Modular socket (ISI) |
| 40 | 6/16A Modular twin socket (ISI) |
| 41 | Supply and fixing of following multi outlet power supply boards made of with suitable size PVC board with following combination of 5 Amps Piano type switch & 5 Amps piano type socket i/c interconnection with suitable size copper conductor cable as required. |
| 42 | Combination of4 nos 5 amps piano type switch & 4 nos 5 amps piano typesocket (ISI) |
| 43 | Combination of2 nos 5 amps piano type switch & 2 nos 5 amps piano typesocket (ISI) |
| 44 | Ceiling Fan hook made of withheavy duty mild steel with fasteners i/c drilling holes on concrete ceiling and fixing firmly to withstand the static and dynamic loads of the ceiling fans as required |
| 45 | S/F of PVC vinyle flooring mat of 1.5 mm thick on the lift floor with suitable adhesive with neat finising & cleaning etc completet as required. |
| 46 | Supplying of following Copper sockets ( Ring/Pin) for end termination in place of damaged ones. |
| 47 | 35 Sqmm Copper sockets ( Dowells/Lotus/ or SS make) |
| 48 | 25 Sqmm Copper sockets ( Dowells/Lotus/ or SS make) |
| 49 | 16 Sqmm Copper sockets ( Dowells/Lotus/ or SS make) |
| 50 | 10 Sqmm Copper sockets ( Dowells/Lotus/ or SS make) |
| 51 | 6 Sqmm Copper sockets ( Dowells/Lotus/ or SS make) |
| 52 | 4 Sqmm Copper sockets ( Dowells/Lotus/ or SS make) |
| 53 | Supplying of following Copper sockets ( Ring/Pin) for end termination in place of damaged ones. |
| 54 | 300Sqmm Aluminium sockets ( Dowells/Lotus/ or SS make) |
| 55 | 240 Sqmm Aluminium sockets ( Dowells/Lotus/ or SS make) |
| 56 | 185 Sqmm Aluminium sockets ( Dowells/Lotus/ or SS make) |
| 57 | 150 Sqmm Aluminium sockets ( Dowells/Lotus/ or SS make) |
| 58 | 120 Sqmm Aluminium sockets ( Dowells/Lotus/ or SS make) |
| 59 | 95 Sqmm Aluminium sockets ( Dowells/Lotus/ or SS make) |
| 60 | 70 Sqmm Aluminium sockets ( Dowells/Lotus/ or SS make) |
| 61 | 50 Sqmm Aluminium sockets ( Dowells/Lotus/ or SS make) |
| 62 | 25 Sqmm Aluminium sockets ( Dowells/Lotus/ or SS make) |
| 63 | Supply and Fixing of MCB protected Socket outlet 4 modules with metal box comprising of 01no. 25Amps socket and 01no. 25Amps Plug and 01no. 25Amps \"C\" series SPMCB for Split AC units’ i/c grouting in wall, connection, testing etc. as required. (Make: Legrand/ L&T / Schneider Electric/ Siemens/ ABB) |
| 64 | SITC of 12Vsealed maintenance free battery of not less than 18AH capacity with all accessoriesetc as reqd.(Exide /Amco/Superior) ( For lift operation) |
| 65 | Supply and fixing of following size PVC cable manager for protection of cable/ wires as required. |
| 66 | 75 mm X 150 mm size(ISI) |
| 67 | Replacement of following faulty electrical itemsby new ones suitable for operation on 230 volt, 1-ph /415 volt, 3 phase A.C supplyafter disconnection & removing the old defective ones, i/cconnection & testing etc. as required. |
| 68 | Replacement of old damaged 2X40 SMO type fittings by new 36 watt surface mounted square shape with low height CRCA housing & high transmitivity diffuseLED luminaires suitable for operation 230 volt 50 Hz AC supply etc completeas required.(Make : M/s Crompton LCTLSNE-36-FO-CDL or S. S make) |
| 69 | Replacement of old damaged 2X40 SMO type fittings by new 2X20 watt 4ft box type LED fittings suitable for operation on 230 volt 50 Hz AC supply etc completet as reqd.(Make : M/s Phillips, M/s Crompton or S. S make) |
| 70 | Replacement of damaged and life expired ceiling fans by new ones of 1200 Ceiling Fans for the Officers Quarters i/c installation, connection and testing etc. as required. (Havells Elegant White Or Equivalent of Usha/Bajaj/Crompton) |
| 71 | Providing 380 mm size exhaust fans for the toilet i/c installation, connection and testing etc. as required. (Havells Veltil Air DX HS Or Equivalent make of Usha/Bajaj/Crompton) |
| 72 | Replacement of burnt out energy meter by new(10 - 60) Amps range suitable for operation on single phase 230 volt 50 Hz AC supply etc completet as required . (M/s Secure or s,s make) |
| 73 | Replacement of unrepairable wall mounting fan by new 400 mm sweep wall mounting fansuitable for operation on 230 volt , single phase, 50 Hz AC supply , connection and testing etc. as required. ( M/s Usha/Bajaj/Crompton or s.s. make) |
| 74 | S/F of spot light light suitable for operation on 230 volt , single phase, 50 Hz AC supply , connection and testing etc. as required. ( M/s Phillips/ Usha/Bajaj/Crompton or s.s. make) |
| 75 | Replacement of faulty capacitor bank by following rating new heavy duty capacitor bank of box type suitable for operation on 440 volt 50 Hz AC supplyi/cconnection on loadand testing etc. as required. ( M/sor L & T or s.s. make) |
| 76 | 20 KVAR |
| 77 | 15 KVAR |
| 78 | Replacement of old & damagedstreet light fitting by new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with minimum IP65 protection and above and impact resistance of IK07 in place of existing faulty fittingsi/c connection, testing etc. as required. (Make:Havells / Phillips/Crompton/Bajaj) |
| 79 | 70 W LED street light fitting |
| 80 | Supply and laying of 2.0mm thick Rubber mat as per IS 15652:2006 having High electrical insulation resistance, 100% shock proof, fire retardant, moisture proof, washable type suitable for providing at electrical panels etc. as required. (Make- ISI) |
| 81 | Supply of the following sizesPVC insulated & PVC sheathed Aluminium conductor armoured cable 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988i/c transportation to respective sites etc. as required for replacement of faulty/burnt out cables. |
| 82 | 2 core 6 sqmm |
| 83 | 4 core 25 sqmm |
| 84 | 3.5 core 50sqmm |
| 85 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 86 | Up to 35sqmm |
| 87 | Above 35 sq. mm and up to 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 88 | Replacement of damaged MV cable end terminationswith brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 89 | 2 X 6 sq. mm (19 mm) |
| 90 | 4 X 25 sq. mm (28mm) |
| 91 | 3½ X 50 sq. mm (35mm) |
| 92 | P/F of M.S. angle,M.S. sheet& M.S. flat etc. on wall i/c cutting, welding,fabricating making good the damage complete as required. |
| 93 | 35mm x 35mm x 5mm Angle. |
| 94 | 25mm x 5mm Flat. |
| 95 | 18 SWGm.s sheet |
| 96 | Fault attending & repairing of 15 Litre capacity storage type gyser after dismentaling from the existing position, replacing thefaulty spares by new one, reassembling & refixing the sameetc as required. (Make: V-guard/ Cromptonor s.s make) |
| 97 | Replacing the following faulty spares of 15 litres of geser by new one,i/c testing etc as required.(Make: V-guard/ Cromptonor s.s make) |
| 98 | 2000 watt heating coil element |
| 99 | Thermostat |
| 100 | Thermal cut |
| 101 | Replacement of faulty 15 Litre capacity storage type gyser by new 5 litre capacity instant heating typeafter dismentaling the faulty one from the existing position & fixing the new one i/c connection testing etc completet as required. |
| 102 | SITC of 12Vsealed maintenance free battery of not less than 180AH capacity with all accessoriesetc as reqd.(Exide /Amco/Superior) ( For 100 KVA DG set) (Note : The old battery may be retaininedby the bidder) |
| 103 | Replacement of faulty pump starter by new one having 20Amps AC3 duty 3 pole contactor with wide band coil voltage varying from 190V to 400 Volts and bi-metallic thermal overload relay range phase losssensitive and ambient temperature compensated trip class 6, single phasing and unbalanced voltage protection, housed in a powder coated deep drawn sheet steel enclosure (IP54) enclosure with START and STOP push buttons, 0-500 volt AC volt meter and 0-30A AC Ammeter with selector switches, motor Run and Stop indicators etc. complied with auto switchi/c connection and testing etc. as required. |
| 104 | With Overload relay range (13.2 Amps-20. Amps) (Make BCH Shakti DOL , model CPEYSAGZ or or equivalent of Siemens/L&T/ABB) |