| 1 | Demolition of brick work of any descriptionand in any positionnot otherwise specifically providedfor complete all asspecified. |
| 2 | M&L for brickwork with fly ash old size bricks straight or curved on plan exc. 6m mean radius built in CM 1:6 complete all as specified |
| 3 | Taking downcement plasteror cement lime plasterof any description including racking outjoints and hacking for key and scrubbing down withwater etc. |
| 4 | M&L for rendering10mm thick cement plaster 1:6, incl finishing even and smooth without using with out extra cement on internalfaces. |
| 5 | M&L for rendering 15 mm thick on fair faces of brick work in CM 1:4 finished even and smooth with using water proofing compound @3%, without using extra cement complete all as directed. (Note : WPC will be measured separately) |
| 6 | M&L for cement plaster 1:3,5 mm thick incl finishing even and smooth without using extra cement on ceiling. |
| 7 | Supply only Integral waterproofing compound |
| 8 | M&L for three coats of white wash to ceiling surfaces including preparation of new surfaces complete all as specified |
| 9 | M&L for preparation of old decorated surfaces of ceiling , spoiled by smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots by scraping and applying one coat of white wash , complete all as specified and directed by Engr-in-Charge. |
| 10 | M&Lforpreparationofnewplastersurfaceofwallandapplying two coatofwhitewashoveracoatofprimer complete all asspecifiedanddirected |
| 11 | M&L for preparation of old decorated surfaces of walls and cornices, spoiled by smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots by scraping and applying one coat of white wash , complete all as specified and directed by Engr-in-Charge. |
| 12 | M&L for preparation oftwo coat of cement base paintover a coat of alkali resistant primeron newely plastered surfaces of walls complete all as directed |
| 13 | M&L for preparation of old decorated surfaces of walls and cornices, spoiled by smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots by scraping and applying one coat of cement base paint , complete all as specified and directed by Engr-in-Charge. |
| 14 | M&L for preparation of old painted wood or wood based surfaces of any description over 10cm width or girth andapplying one coat of Synthetic enemal paint, complete all as specified and directed by Engr-in-Charge. |
| 15 | M&L for preparation of oldpainted steelsurfaces of any description over 10cm width or girth and applying one coat of Synthetic enemal paint, complete all as specified and directed by Engr-in-Charge. |
| 16 | M&L for preparation of old decorated surfacesof walls and cornices, spoiled by smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots by scraping and applying one coat of oil emulsion distemper, complete all as specified and directed by Engr-in-Charge. |
| 17 | Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above GL) |
| 18 | Dismantling Stone slabs and tiles laid dryandpointed of any description or thickness in floors, aprons etc all asspecifiedandasdirected. |
| 19 | M&L for 75 mm thick Cement concrete type D4, 1:4:8 (40mm graded aggregate)asinsubbase |
| 20 | M&L for 50 mm sand filling under floors or in foundations including watering and consolidation spread, rolled and consolidated to gradient and camber required |
| 21 | M&L forMachine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and pigment. |
| 22 | M&L for 20 mm thick screed bed or bedding layer of mortar in cementmortar 1:6 for lying floor finishes. |
| 23 | M&L chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick, set jointed and pointed in neat cement slurry with grey cement and pigments. |
| 24 | M&L fornonabrasive ( endura)tiles300mm x300mmx10 mm thick( square/rectangular )polished ,in floorsetcsetandjointedinnceatcementslurryandpointedinwhite orcolouredcementover& including15 mmscreedbedin CM 1:4atomatchcomplete all asspecifedanddirected Note :-the texture, colour , shadeoftiles& layingoftilesto any pattern& anydesign with oneormorecolour shallbeapprovedby GE completeall asspecifiedanddirected |
| 25 | Dismantling of floor, hearth or wall tilling incl cement mortar bedding (but not backing) and removing the rubbish off the premises complete all as specified and as directed by Engineer -in-Charge. |
| 26 | M&L for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tilescomplete all as specified and as directed by Engineer -in-Charge. |
| 27 | M&L for coloured Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tilescomplete all as specified and as directed by Engineer -in-Charge. |
| 28 | M&L for coloured Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles complete all as specified as directed by Engineer -in-Charge. |
| 29 | M&L for 15 mm thick screed bed or bedding layer of mortar in cementmortar 1:6 for lying floor finishes. |
| 30 | M&L for rendering 10mm thick in cement mortar 1:4finished rough to receive walltiles etc. |
| 31 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground |
| 32 | Dismantlingexistingbarbedwire fencingofany description, shapeetccomplete all asspecifiedanddirected. |
| 33 | Excavation in post holes each n exc 0.50m gatting out returning filling and remaining earth or broken rubble mixed with earth around in layers n exc 25cm getting out in hard/densesoil |
| 34 | S&F Mild steel angle iron as posts and struts in fencing including cutting tops to shape as directed, drilling hole including all necessary drilling, bolting or riveting etc and similar work conforming to Fe 290 Gde E 165 |
| 35 | M&L for PCC (1:3:6) type C2( using 40mm graded agg) as infoundation, filling and mass concrete etc. |
| 36 | Supply only chain link fenching of size 75x75 mm mesh of cages with 3.15 to 4 mm dia Mild Steel Galvanised Wire,complete all as specified and as directed. |
| 37 | Fixing only Chain Link Fencing 75X75mm Mesh or Cages with 3.15 to 4 mm dia Mild Steel Galvanised Wirelapped, Straining and Binding with including Mild Steel Wire (annealed) not less than 0.9 mm dia, complete all as specified and as directed. Note:- weight will be decided by BOO convayed by GE. |
| 38 | M&L for Mild Steel Flat (size=40x5 ) as Bands, etc. to Fencing Post with Ends of Bar shouldered and/or riveted or forged into Spikes, Framed Guard Bars and Similar Work, etc. conforming to Fe-410-0 or Fe-310-0 including all necessary drilling, bolting or riveting, etc., complete all as specified and as directed. |
| 39 | M&L for Mild Steel Screw Bolts (Machine Made) with Hexagonal Head at one End and screwed the other Ends, each screwed End to be fitted with Washers and One Hexagonal Nut, diameter of Shank 5 to 10mm Length of Bolt exc. 100mm but not exc. 150mm, complete all as specified and as directed. |
| 40 | M&L for preparation of new surface & applying two coats of synthetic enamel paint over a coat of red oxide zink chrome primer to steel surfaces exc 10 cm girth. |
| 41 | M&L forpreparation new steel surfaces of any description n exc10cm width or girth andapplyingtwo coatsyntheticenamel paintover a coatofredoxide when unconnectedwith other ainting orwhen painted in different tint complete all asspecifiedanddirected. |
| 42 | M&L forTMT bar 10 mm diaand over cut to length bent to shape required, including cranking, bending, spirally for hooping for column hooking ends and binding with and including mild steel steel wire (annealed ) not less than 0.90 mm dia or seccuring with clips quility confirming to Deformed or twisted bars. |
| 43 | S&F galvanised. 2 strand, steelbarbed wire 2.24mm diabarbed with 2mm dia barbs at75mm spacings and straining and fixing to any type ofstandard rails strain- ingbolts, including, securing ortying at crossings with and provision of galvanised mildsteel wire, staples or steelpins, etc. as directed (eachline wire to be measured) |
| 44 | S&F inrepairgalvanised. 2 strand, steelbarbed wire 2.24mm diabarbed with 2mm dia barbs at75mm spacings and straining and fixing to any type ofstandard rails strain- ingbolts, including, securing ortying at crossings with and provision of galvanised mildsteel wire, staples or steelpins, etc. as directed (eachline wire to be measured) |
| 45 | Taking down chowkhats of frames with shutter without taking taking off shutters from the frames not exc. 1.5 sqm |
| 46 | Taking down chowkhats of frames with shutter without taking taking off shutters from the frames n. exc 1.5 sqm but not exc. 04 sqm |
| 47 | M&L for Solid PVC door frame of size 50x47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube suppling and fixing in opening as per specification and drawing. |
| 48 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing in SSR complete all as specified and directed by Engr-in-Charge. |
| 49 | S&F 165x60mm pressed steel frames for door with one or more rebates including necessary fixing lugs,hinges ,lock ,strike plate etc |
| 50 | M&L for PCC 1:3:6type C-0 using 12.5 mmgragedcrushedstoneaggregateasinbackfillingofchowkat |
| 51 | M&L for35mm thick flush shutter,solid core construction with block board core and plywood face panels,commercials type on both sides complete all as specified and directeb by Engineer in Charge |
| 52 | S&F 35mm thick IInd class hard wood Glazed and skeleton shutters, for windows and ventilators and door open rebated and prepared to receive glass, gauze, etc., divided in to squares with plain, chamfered or rounded mitred and rebated sash bars any numbers, edges of framing plain, chamferesd or rounded, fitted with cut and mitred beads for securing glass etc., size of members of shutter as specified in SSR Part-I, Sec-8, Clause 8.24 aand fixed to chowkhats complete all as specified and directed. |
| 53 | S&F of steel window/ventilator factory made, made out of mild steel box type and shutter suitable for double shutter i.e. glazed and gauged shutter. Glazed shutter made out of hollow section with sash bar and gauged shutter made out of hollow section without sash bar including hinges, tower bolt, handle, grill 10mm sq bar including two coat of synthetic enamel paint over one coat of red oxide primer, atrred hold fasts, PCC bed blocks for fixing hold fast, including plain/ figured glass and stainless steel wire cloth 0.36mm nominal dia of wire & average width of aperture 1.18mm & fixed with stainless steel wire staples etc complete all as per drg No CEPZ/ TD-245/01Sheet No 1/1 & CEPZ/ TD-246/01 sheet No 1/2 & 2/2 including taking down old windows/ventilators, complete all as specified and directed. |
| 54 | S&Fstainless steel wire cloth, 0.56mm nominal dia of wireandaveragewidth of aperture 1.40mm and fixed with tinned tacks, orstainless wire staples etc.complete all as specified and as directed by Engineer-in-charge. |
| 55 | S&F in repairs stainless steel wire cloth, 0.56mm nominal dia of wireandaveragewidth of aperture 1.40mm and fixed with tinned tacks, orstainless wire staples etc.complete all as specified and as directed by Engineer-in-charge. |
| 56 | S&F 100 mm long SSbutt hingeswithgalvanisedmild steel hinge pin anodised andfixed complete all as specified |
| 57 | S&F 150mm long aluminium anodised, barrel tower bolts of extruded section |
| 58 | S&F aluminium handles 150mm long fabricated type anodised all as directed |
| 59 | S&F 300mm long MS ordinary rat tail rod pattern springs including roller and roller platefixing to door frame with welding or any means complete all as specifid and directed by Engineer in charge. |
| 60 | S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fix clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed |
| 61 | M&L for preparation of new wooden surfaces and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and directed. |
| 62 | Dismantling Asbestos cement (corrugated semicorrugated) sheet in roof coverings |
| 63 | S & F pre painted galvalume aluminium zinc coating GI based corrugated steel sheets 0.50 mm thick any colour having tensile strength 0f 550 Mpa ( AZ-150 gm/sqm) as in roof covering/wall cladding to walls, fixed with self tapping screws as specified and directed. |
| 64 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) or directed by Engr-in-Charge fixed with self tapping screws as specified |
| 65 | Dismantling structural steel work including doors, gates,etc all as specified and directed by Engineer in Charge |
| 66 | S&F Rolled mild steel in joist ,channel angle or tee section, flat ironfixed independently qualityconforming to Fe 410W(Gde-250) all as specified |
| 67 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets |
| 68 | S&F falseceilingwithfibrecement designer tiles ivory painted (high pressure steam cured) of 4 mm thickness (as per IS:14862) of size 595x595 mm and any one of the design (oceanic, lake & hill, cascade or electra) in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms, both side inclusive) consisting of main \"T\" runnerwith suitably spaced joints to get required length, and 15x32mm made if 0.30 mm sheet and cross \"T\" at 600 mm c/c to form a grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI soffit cleats fixed to existing ragter, purlin, etc with galvanised butterfly level slips, spaced at 1200 mm c/c along main T, bottom exposed width of 15 mm of all T-sections shall be centra black pre-painted with polyester paint, and having a load bearing capacity of 12 KG/spm, and refixed all existing electric wiring and fixture all complete at all heights as per direction of Engineer-in-Charge. |
| 69 | S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position, etc complete all as specificed and as per directed by Engineer-in-Charge. |
| 70 | S&F in repairs,10 litre capacity, low level PVC flushing cistern, syphonic action type white colour with in let ball valve float and handle, PVC flush pipe, brackets etc complete all as specified and as directed by Engr-in-charge |
| 71 | S&F in repairs Bib tap, cast copper alloy, 15mm dia long body with crutch or butterfly handle screwed down for iron pipes complete all as specified and as directed by Engineer-in-Charge. |
| 72 | S&F in repair vitreous china squattingpanofpattern , longpan, \"Orissa Pattern\", size 580x440 mmwhite withintegral foot rests ( excludingflushingcisternandflush pipe ) butincludingprovision of concrete beddingCI floortrap etccomplete |
| 73 | S&F in repairsvitreouschinawash basin , flat backwhite ofsize 550x 400 mm , including cutting for and pinning in ends of brackets or erecting standincluding 32 mmboreCPwastepipelongscrewthreadand32mm diaflexiblewastepipe includingfixingof pillartapsall as specified anddirected. |
| 74 | S&F in repairs 15mm bore Fancy type pillar taps, long shank (swan neck), Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed. |
| 75 | S&F in repairs Fancy type chromium plated 15mm bore Stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions. |
| 76 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads (ht up to 15 m) |
| 77 | S&F plain sheet glass ordinary quality and glazing with oil putty /wdn beads in square n.exc.0.50sqm in each pane 3 mm thick plain glass on new or old windows all as specified and directed by Engineer-in-Charge. |
| 78 | S&F 5 mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all asspecifiedanddirected |
| 79 | Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all asspecified anddirected. |
| 80 | M&L for 100 mm thick PCC typeB-1, 1:2:4 (using 20mm graded crushed stone aggregate) as in hard standing finishedeven and smooth withoutusing extra cement. With spike rolling to to surface or maing impressedof expanded metal. |
| 81 | Dismantling of1000 ltr water storage tanks and removed to store complete all as specified. |
| 82 | S&F 1000 ltr capacity ofrotational moulded PVC water storage tank (cylindrical vertical with closed top) hoisted and fixed in position including float valve, nipple, check nut etc. complete all as specified and directed. |
| 83 | Taking up or down, 15mm dia bore, GI tubing, medium grade, including removal from site, complete all as specified and as directed by Engineer-in-Charge. |
| 84 | Taking up or down, 20mm dia bore, GI tubing, medium grade, including removal from site, complete all as specified and as directed by Engineer-in-Charge. |
| 85 | S&F 15mm bore steel tubing medium grade galvanised with all fittings and fixedcomplete to walls or laid in floors complete all as directed by Engr-in-Charge |
| 86 | S&F in 20mm tubes medium grade galvanised with all fittings and fixed complete to walls or laid in floors bore of pipe complete all as specified and directed |
| 87 | Demolition of Lime concrete / Mud phuska / PCC of any description and in any position not otherwise specifically provided for renewal including removal of demolished material beyond the Md land to a distance exceeding 500mtr not exceeding 1.5KM completed all as specified and directed. |
| 88 | M&L for 25mm thick PCC (1:2:4) type B-0 using 12.5mm graded crushed stone aggregate as in padding concrete (levelling course) on roof complete all as specified and as directed by Engr-in-Charge. |
| 89 | M&L for liquid water proofing treatment to RCC roof slab including dismantling of existing roof treatment of any description such as worn-outtar felt, debris, mortar of any description & any thickness, surface cleaning of all foreign material such as shrubs/roots, fungus, moss, dust including plaster, APP membrane etc. including disposal of debris out of MoD land, in following procedure : (a) Prepare the surface by cleanining with concrete surface grinder/ wire brush and a high pressure water jet and ensure that it is free of dust, oil and loose particles. Damaged portions, hollow area must be repaired with epoxy mortar and repair cracks of old concrete by cutting \"V\" groove, corners and joints of drain pipes, channels etc. treated with epoxy mortar prepared with epoxy primer (as per manufacturer\"s instructions).(b) Laying 10mm thick rendering in Cement mortar 1:3 with liquid water proofing compound (as per manufacturer’s instructions) on fair faces of concreteroof surfaces, finished even and fair to receive treatment on roof Complete |
| 90 | Contd.....(c) Applying three coats of polyurea waterproofing coating as per manufacturer\"s instructions for maintaining minimum dry film thickness 1.5mm and elongation at break of free film of approx. 500% ± 50% and tensile strength at 14 days of 5MPa.(d)The materials shall be applied with brush or roller, complete in all respect as per the direction of Engineer-in-charge / Consultant. (Note:- minimum 6 hrs interval between two coat shall be maintained)(e) All auxiliary and accessories involved during application should be supplied by single manufacturer as a part of system.Note:- (i) Work to be carried out by authorized applicator and as per manufacturer’s instructions.(ii) Providing test with filling of water for continuous 48 hours if there is any leakage than entire treatment will be done again by contractor without any cost.(iii) The rate includes for filling cracks in existing roof with epoxy cement mortar using suitable bonding agent before laying cement plaster. |
| 91 | Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 60,778.00 and any other reduction if any from quoted amount. |