| 1 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed. |
| 2 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated of any profile steel sheet corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified up to anyheight including all necessary scaffolding and safety measures complete all as specified and directed. |
| 3 | M & L forpre-paintedhot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specifiedany heightMtr height including all necessary scaffolding and safety measures complete all as specified and directed. |
| 4 | Dismantling Wrought Iron or Mild Steel Work, viz. Mild Steel Flat Iron, Mild Steel Bars, Bends, Straps and Similar Work including Mild Steel Bolts, Nuts, etc., fixing to RCC Fencing Posts, Struts, etc. complete all as specified and as directed. |
| 5 | S&F of Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 ® |
| 6 | S&F in repairs Turbo ventilator SS built with vane thickness 0.9mm with ball bearings, turbine dia 760mm with bottom ring dia 600mm, FRP base plate 2mm thick clear 1.02 mtr wide and 1.65m long matching the profile of existing sheet, weight approx 8.0 Kg complete all as per manufacturer instructions and as directed. |
| 7 | Taking downoflight fittings of any type size and modelcomplete all as specified and directed. |
| 8 | Taking downofbrackets of any type size and modelcomplete all as specified and directed. |
| 9 | Dismantling RCC/steel poles/struts, any size complete all as specified and directed. |
| 10 | Taking down/out unserviceable UG Cables of any Cross Sectional Area and Connections including Bricks, GI Pipes, etc. of any descriptions, laid in Trenches and/or fixing with Walls/Poles including Segregating of Serviceable Materials viz Bricks, Cables, GI Pipes, etc. and keep in Safe custody for re-use, complete all as specified and as directed |
| 11 | Material and labour for steel tubular poles complete with cast iron base palate, final taper plug bolts, nuts & screws as specified type 410 SP-22 8.50 meter long including painting all external exposed steel surfaces with two coats of aliminium paint over a coat of red oxide zinc chrome primer including marking pole numbers in a 15 cm dia yellow circle with number writting with blacksyenthic paint/ Stricker, includingpainting strips in alternate from top of coping upto 1.50m height, with three strips of black syenthaticpaint & two strips of Yellow/ Sky blue paint(as per existing pattern through out the circumference of pole), including and all internal surfaces and external surfaces upto the planting depth shall be painted with two coats of black bitumenous paint complete all as specified and as directed Note:- Earth work, PCC work, shall be measured and paid separately.(ii) Execution of swaged pole will be allowed only after submission of Purchase Voucher and Manufacturing Test Certificate, to the Engineer-in-Carge |
| 12 | S&F Cable Junction Box 155X210X92 mm in size, made out of thermoplastic, having IP 66 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32 -02 No & M-25 -01 No) fixed on poles with Aluminium clamps of size 25x3mm, nuts, bolts, washers etc. complete all as specified and as directed. |
| 13 | Supply and passing through steel tubler pole/service connection, 1100 volts grade multicore,FR, round insulated copper conductor and sheathed flexible cable,multistranded, three coreofnominal cross sectonal area1.5 Sq mm,for connection of security light from junction box through pole /conduit with all terminals complete all as specified and as directed. |
| 14 | M&L Street Light Fittings Bracket, fabricated from GI Pipe 40mm Bore (dia), Light Grade, 1.00 METRE long, bend to required shape and fixing with and including Mild Steel Flat Iron Clamps 40X5mm of suitable Length, 2 No. Nuts, Bolts, Washers, etc., to Pole, applying Painting with One Coat of Red Oxide Zinc Chrome Primer and over Two Coats of Aluminium Paint to Mild Steel Works including Taking down old unserviceable Street Light Fittings Bracket, complete all as specified and as directed. |
| 15 | Material andlabour for earthing complete with Galvanised steel earth plate electrode 600x600x6 mmmm buried directly in ground (Earthpit not less than2.25m below ground level) with top edge of theplate not less than 1.5m below normal groundlevel, connected to GI strip 32 x 6 mmasearth lead by means of bolt, nuts, check nutsandwashers of galvanised iron or steel, upto 7.5mlength, earth strip protected by andincluding 40 mm diaGI pipe (md grade) andconnected to main test point or body of pole/pannel or lightening arrester of main controlling switch as directed including concrete pit in PCC(1:3:6)type C1 , Precast RCC(1:2:4)TypeB1 coverslab of size 54x54x5 cm reinforced with 8 mm dia TMT bars @ 100mm C/C bothwayswith onehandle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20 mm boreGI Pipe (Medium Grade) for watering, Charcoal andsalt in alternate layers of 15 cm (Compacted Thickness) around the earth electrode including necessary excavation, earth work in any typeof soil anddisposal of spoil to a distance n.exc50 m andnecessary testing complete all asshown in Electrical Plate No 3 of SSRPart-I.NOTE : 1. The unit rare includes for protectionh GI pipe of 40mm and watering pipe of 20mm bore including excavation for earth pit in any type of soil/disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to acheive desired result as the soil resisitivity is very high. 3. The cost of GI wireincluding protection pipe,from top of earth plate upto 7.5 meter above/below ground level is deemed to be included in the unit rate. 4. All the joints in GI wire and connectgion with earth plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5.Costing of welding and nut bolts are deemed to be included in the unit rate |
| 16 | Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole, laying of cables, pipes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soilNote : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding. |
| 17 | Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed. |
| 18 | Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed. |
| 19 | M&L Sand Cushioning (dry) in trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE : For the purpose of Payment, Punned thick-ness of Sand Cushioning only shall be Measured and Paid ) |
| 20 | Supply and laying well burnt Bricks , locally available best quality (sub class \"B\" bricks) laid in trenches perpandicular to U/G cable for cable protection complete all as specified. |
| 21 | Laying only in trenches or passing through pipe, XLPE insulated,heavy duty,galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 50 sqmm 3.5 core.Note : Cable will be issued under Sch B free for laying only |
| 22 | Laying only in trenches or passing through pipe, XLPE insulated,heavy duty,galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 10 sqmm 4 core.Note : Cable will be issued under Sch B free for laying only |
| 23 | Supplying and fixingHigh density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 complete with all fittings of 40 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers as in cable/earth strip protection complete all as specified and directed. |
| 24 | S&F Galvanised Iron Pipe 40mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. |
| 25 | Labour only for Horizontal Boring for PassingProtection Pipe up to 80mm Bore (dia), under Road /Foot Path, not exc. 10.00 mtr in a Single Length, complete all as specified and as directed. Note : Pipe to be measured separately. |
| 26 | M&L for PCC (1:2:4)type B1 (using 20 mm gradedaggregate) as in coping for pole including form work and finishing the surfaces even and smooth,dismantling etc complete all as specified and as directed. |
| 27 | M&L for PCC 1:3:6 type C2 (using 40 mm gradedaggregate) as in foundation for pole etc complete all as specified and as directed. |
| 28 | Supply and fixing CRCA sheet steel duly phosphatized and powder coated with 7 tank process,wall/pole mounted/floor mounted,degree of protection IP 54,pre-wired,liberal terminal space,louvers provided on both sides for proper heat heat dissipation,manufactured by an ISO 9001 certified company,door locking by panel lock and provided for pad locking available,with auto/manual selection switch,astronomical programmable time switch( Operating voltage 220-240 Volt AC),three phase,MCB TPN 63 Amp(coil voltage 240 Volt AC) ,Power Contactor 65 Amp,TP,Astronomical timer,terminal blocks,maximun load 12KW, complete all as specified and as directed. |
| 29 | Fixing onlyLED street light fitting 100Watt 230 V AC outdoor type including necessary connection complete all as specified.Note : Street light will be issued under Sch B free for fixing only. |
| 30 | Fixing only LED Flood light fitting 200Watt 230 V AC outdoor typecomplete all as specified and directed.Note : Flood light will be issued under Sch B free for fixing only. |