| 1 | Excavation in post holes (or similar holes) each n. exc. 0.5cum, getting out, n. exc. 25 cm, removing surplus soil to a distance n. exc. 50m and making good surface soft/loose soil complete all as specified and directed. |
| 2 | M&L for providing cement concrete 1:2:4 type B-2 using 40 mm graded crushed stone aggregate as in foundation ,filling and mass concrete complete all as specified and directed. |
| 3 | S & F angle for posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 4 | S & F12mm thick lead free, termite & moisture resistance and fire retardant PVC board as in view cutter fixed with using corrosion resistant screws into post complete all as specified and as directed. |
| 5 | M&L Cement concrete 1:4:8 type D2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete, complete all as specified and directed. |
| 6 | M/L brick work with flyash bricks old size straight or curved on plan to any radius exc 6m mean radius build in CM 1:6 complete all as specified and directed. |
| 7 | M&L for15mm thick in CM 1:4 rendering on brick or concrete surfaces finished fair and even withon wall complete all as specified and directed. |
| 8 | M&L for treatment of wall &applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004 , alkali & fungal resistance, dirt resistance exterior paint of required shade (Company depot tinted) with silicon additives@ 1.43 litre/10sqm over and including priming coat of alkali and fungal resistance exterior primer applied @ 0.90 litre/10 sqm including a coat of putty 1 mm thick plastered surface to prepare the surface even and smooth for smooth finish over new surfaces complete all as directed by Engineer in Charge. |
| 9 | M&L for preparation of surfaces of steel and iron of any description over 10cm in width or girth not other wise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 10 | M & L forpre-paintedhot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specifiedany heightMtr height including all necessary scaffolding and safety measurescomplete all as specified and directed. |
| 11 | E/M PORTIONTaking down carefully aluminium conductor point wiring (light,fan,socket or power) completeincluding fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing(except those to be reused shall be kept in safe custodyat the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified. |
| 12 | M & L for concealed point wiring for fan/light point controlled by one one way switchcomplete with 1.5 sq mm FRLSH,PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red/yellow/blue wires for phases and black wire for neutral),drawn into and including non metalic PVC rigid conduit medium grade of suitable size and conduit accessories fixed on wall, floor, roof etc. and including PVC FRLSH insulated 1.5 sq mm copper conductor for earth continuity (Green Colour)and connected to common earth dollyincluding sunken in GI terminal box2.8 mm thick bakelite hylam sheet cover, ISI marked with CM/L no. for mounting switch & sockets ect.Note : a) Note :- Cost of PVC conduit, cutting chases of wal/ceilingl, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surfaceare deemed to be included in the quoted rate. |
| 13 | All as per item No. 12.00 here-in-before but5 Amp socket on same boardwith other switches complete all as specified and as directed. |
| 14 | All as per item No. 12.00 here-in-before butone bell pointwith other switches complete all as specified and as directed. |
| 15 | All as per BOQ item No12.00 here-in-beforebut for one power pointtusing by2.50 sq mm FRLSH,PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red Colour use for Phase & Black Colour use for Neutral), and with and including FRLSH,PVC insulated multi stranded copper conductor single core 2.50 sq mmconductor for earth continuity (Green Colour) , on independent board( but Not below the switch board of light points in the same vertical plane). |
| 16 | All as per BOQ item No12.00 here-in-beforebut for one power pointtusing by4.00 sq mm FRLSH,PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red Colour use for Phase & Black Colour use for Neutral), and with and including FRLSH,PVC insulated multi stranded copper conductor single core 4.00 sq mmconductor for earth continuity (Green Colour) , on independent board( but Not below the switch board of light points in the same vertical plane). |
| 17 | Material & Labour forpoint wiringcomplete with 1.5 sq mm FRLSH, PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red Colour use for Phase & Black Colour use for Neutral),drawn into and including PVC casing- caping (double interlock type) ofnot less than 20mm width with accessories and fittingssuch as bends, elbows, tees, crosses, junction box etc, fixed on wall/ceiling with GI saddles, GI screws, rawl plugs etc. for one light/fan/ bell point controlled by one switch including pressed steel terminal box powder coatedof suitable size with 3 mm thick plastic laminated sheet cover of approved make for housing/mounting switches, sockets & regulators etc. and drawing1.5 sq. mm copper solid conductor PVC insulated, unsheated cable as earth continuity conductor, connected to common earth and earth dolly , all as specified and directed by Engineer-in-ChargeNote :- Cost of PVC casing & capping, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate. |
| 18 | All as per item No. 17.00 here-in-before but5 Amp socket on same boardwith other switches complete all as specified and as directed.. |
| 19 | All as per item No. 17.00 here-in-before butone bell pointwith other switches complete all as specified and as directed.. |
| 20 | All as per BOQ item No 17.00 here-in-beforebut for one power pointtusing by2.50 sq mm FRLSH,PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red Colour use for Phase & Black Colour use for Neutral), and with and including FRLSH,PVC insulated multi stranded copper conductor single core 2.50 sq mmconductor for earth continuity (Green Colour) , on independent board( but Not below the switch board of light points in the same vertical plane). |
| 21 | All as per BOQ item No 17.00 here-in-beforebut for one power pointtusing by4.00 sq mm FRLSH,PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red Colour use for Phase & Black Colour use for Neutral), and with and including FRLSH,PVC insulated multi stranded copper conductor single core 4.00 sq mmconductor for earth continuity (Green Colour) , on independent board( but Not below the switch board of light points in the same vertical plane). |
| 22 | Supply and fixed switch piano flush type, single pole , 5/6 Amps, one way complete all as specified. (Note : Item to be measured if executed under new point wiring) |
| 23 | Supply & Fixingsocketoutlets 2 in 1, 5/6 Amps, 230/240 V complete all as specified and as directed .(Note : Item to be measured if executed under new point wiring) |
| 24 | Supply and fix switch socket combination 2 in 1 multipurpose5 pin ,(6 Amps ) flush typecontrolled by one switch complete all as specified. (Note : Item to be measured if executed under new point wiring) |
| 25 | Supply and fixed switch socket combination5 in 1 , 6 pin ,(5/16 Amps ) flush typecontrolled by one switch complete all as specified. (Note : Item to be measured if executed under new point wiring) |
| 26 | Supply & fixed ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified. (Note : Item to be measured if executed under new point wiring) |
| 27 | Supply & fixed stepped type electronic fan regulator flush type 240 Volts ISI marked complete all as specified . (Note : Item to be measured if executed under new point wiring) |
| 28 | Supply & fixed Bell push, flush type , 5 amp complete all as specified. (Note : Item to be measured if executed under new point wiring) |
| 29 | Supply & fixed Buzzer, Ding dong, AC 230 Volts, single pole 230 volts all as specified and directed. (Note : Item to be measured if executed under new point wiring) |
| 30 | Supply & fixed lamp holder, PVC/polycarbonate type with back plate straight or anfular suitable for batten fittings complete all as specified. (Note : Item to be measured if executed under new point wiring) |
| 31 | Supply and fixing for surfacetype sub main wiring with two run of 4.00 Sqmm single core PVC FRLSH PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and including drawn into and including PVC casing- caping (double interlock type) ofnot less than 25mm width with accessories and fittingssuch as bends, elbows, tees, crosses, junction box etc, fixed on wall/ceiling with GI saddles, GI screws, rawl plugs etc. including one run of 4.00 Sqmm single core PVC FRLSH PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified.Note : (i) Note : 2 runs of line conductor,one run of earth continuity conductor, one run of PVCcasing caping shall be measured as unit length. (ii)Cost of PVC casing caping, conductors,making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate. |
| 32 | Supply and fixing for surfacetype sub main wiring with two run of 6.00 Sqmm single core PVC FRLS, PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and including drawn into and including PVC casing- caping (double interlock type) ofnot less than 25mm width with accessories and fittingssuch as bends, elbows, tees, crosses, junction box etc, fixed on wall/ceiling with GI saddles, GI screws, rawl plugs etc. including one run of 6.00 Sqmm single core PVC FRLS, PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified.Note : (i) Note : 2 runs of line conductor,one run of earth continuity conductor, one run of PVCcasing caping shall be measured as unit length. (ii)Cost of PVC casing caping, conductors,making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate. |
| 33 | S&F in repairs LED 9/10 Watt tube light fitting mirrorintregatedtype, includingLED retrofit tubelamp 9/10 W , LED tube light nominal power 9/10 Watt, L LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 115 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 extruded aluminium LED battenslife span of minimum 50000 working hours complete fittingincluding connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fittingincluding taking down old unserviceable complete all as specified & directed.. Note : Make of batten and LED tube lamp should be of same make. |
| 34 | S&F in repairs LED 20 Watt tube light fittingintregatedtype, includingLED retrofit tubelamp 20 W , LED tube light nominal power 20 Watt, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 110 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 life span of minimum 50000 working hours and LED batten with polycarbonate housing and polycarbonate diffuser complete fittingincluding connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fittingcomplete all as specified & directed..Note (i) Make of batten and LED tube lamp should be of same make. |
| 35 | S & F in repairs sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 8 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 , IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match asthe existing withall as specified and directed by Engr-in-charge. |
| 36 | S & F in repairs sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 12 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 , IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match asthe existing withall as specified and directed by Engr-in-charge. |
| 37 | S&F in repairs VTPN distribution boardIS as per IEC 61439-3 with provision for 4 pole MCCB up to 250A as incomer with three phase and single phase (TP/SP) MCB outgoing with and including insulated busbar (tinned electrolytic copper) arrangement, shrouded neutral bar and earth bars, Top and bottom removable gland plates with knockouts 4 way Double door enclosure made up of CRCA sheet steel,powder coated, IP 43, IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match asthe existing withall as specified and directed by Engr-in-charge |
| 38 | S&FMCCB 4 pole, 3 phase, 415 volt of capacity 63 Amp, 16 KA complete with proper copper thimbles, copper reducer etc all as directed. |
| 39 | Supply and fixing 240V, 10 KA \"C\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning. |
| 40 | Supply and fixedMCB SP 40 to 63 Amps,\"C\" series 10kA, 240 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed.(Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating) |
| 41 | Supply and fixedMCB SPN 32 Amps,\"C\" series 10kA, 240 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed.(Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating) |
| 42 | Supply and fixedMCB SPN 40 to 63 Amps,\"C\" series 10kA, 240 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed.(Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating) |
| 43 | S&F in repairs LED 20 Watt tube light fittingintregatedtype, includingLED retrofit tubelamp 20 W , LED tube light nominal power 20 Watt, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 110 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 life span of minimum 50000 working hours and LED batten with aluminium housing and polycarbonate diffuser complete fittingincluding connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fittingcomplete all as specified & directed..Note (i) Make of batten and LED tube lamp should be of same make. |
| 44 | Taking down and Repair/cheking and fixing only and connecting electric meters up to 25 Amp including cheking nutral phase ,earth wire etcall as directed by EIC. |
| 45 | Supply & fixed in repair bell , AC 230 Volts, single pole 230 volts all as specified and directed Make : anchor,Havells or eqvt. |
| 46 | Supply& fixed in repairswitch piano flush type, single pole , 5/6 Amps, one way complete all as specified and as directed. . |
| 47 | Supply& fixed in repair socket outlet 2 in 1 multipurpose3 pin , (6 Amps ) flush typecontrolled by one switch duly marked complete all as specified and directed. |
| 48 | Supply& fixed in repairr switch socket Combination6 A/16A,5 in 1 flush type with fuse & neon indicator controlled by one switch two hole type complete all as specified |
| 49 | Supply and fixed in repair socket Combination 2 in 1,3 pin , (6 and16 Amps ) flush type universal controlled by one switch four hole type complete all as specified |
| 50 | Supply& fixed in repair modular switch 1 way 6A one module., 240 vvlots complete al as specified and directed |
| 51 | Supply& fixed in repair Modular bell push 6A one module 240 volts complete all as specifiedand as directed |
| 52 | Supply& fixed in repair modular Socket6A 2/3 pin combined 2 module complete all as specified and directed . |
| 53 | Supply & Fixing in replacement switch modular type 15/16 Amp one way, two module, single phase, complete all as specified and directed. |
| 54 | S&Fin replacement socket outlet 15/16 Amps, 5 pin, modular type, 2 module , single phase complete all as specified and as directed engr-in-charge. |
| 55 | Taking down existing panel light fitting any type (600 mm x 600 mm) recess mounting/surface and S&F LED light fitting 36 watt recess mounting of size 600 mm x 600 mm , , LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz,lumen efficacy of minimum 115 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, ITHD below or less than 15%, WW available CCT of 3000K power factor of minimum 0.95, CRCA powder coated white after phosphochromate treatment housing, life span of minimum 50000 working hours including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmmx 3 core complete all as specified and directed by EIC. |
| 56 | S & Fin repair LED street/security lights nominal power 35/36 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumenefficacy of minimum 110 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hoursincluding fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed. |
| 57 | Assembling and Hanging only ceiling fan (M.D.supply) and connecting up including provision of cable from ceiling rose or connector to fan including Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store complete all as specified and as directed. Note : Ceiling fan including blade, rod and canopy will be issued under Sch B free for hanging/fixing only |
| 58 | Fixing only in repairs exhaust fan (M.D. supply) made of sturdy Engineering plasticwith necessary bolts including making necessary electric connectionfromceiling rose to the fan with PVC insulated flexible cord copper of size 0.75 sqmm and removing fan and blades to store complete all as specified and as directed. Note : Exhaust fan including louvers will be issued under Sch B free for hanging/fixing only |