| 1 | fo|qr Hk.Mkj dsUnz&ckxir@cM+kSSRk@esjB ls fuEufyf[kr lkexzh 33@11 ds0oh0 midsUnz@dk;ZLFky rd igqpkuk] ftlesa yksfMax ,oa vuyksfMax \"kkfey gSA |
| 2 | 33 KV Lightening Arrestor |
| 3 | 33 KV CT |
| 4 | 33 KV PT |
| 5 | Distribution T/F L.A |
| 6 | Earthing of pole by MS Erathing Road 20x2500mm & 6SWG Earthing wire etc. |
| 7 | 11 KV TPMO with Polymeric Insulator |
| 8 | 33 KV TPMO |
| 9 | 33 KV Post Insulator |
| 10 | 11 KV Fuse Set |
| 11 | 33 KV Fuse Set |
| 12 | 33 KV Bus Isolator |
| 13 | 3 Phase Distrubution Box |
| 14 | Bettery Set 24 Volt & Battery Charger |
| 15 | 33 KV Line Isolator |
| 16 | 33 KV VCB 800A,. 750A with CT 400/200/1-A with CT Structure |
| 17 | Control Cable 2x2.5 mm. sq. |
| 18 | Control Cable 4x2.5 mm. sq. |
| 19 | 33 KV Control Panel for Double T/f |
| 20 | fufonkdkj }kjk fuEufyf[kr lkexzh miyC/k djkuk ,oa lkbZV ij vko\";drkuqlkj yxkus dk dk;ZA |
| 21 | Water Level Earthing (GI Pipe -60 Feet With DIA 1.25 inch Copper Cone-750 Gram Copper Wire 6SWG 60 Feet) for CT PT Panel |
| 22 | Plinth |
| 23 | Fencing |
| 24 | Holding Clamp |
| 25 | Providing & Fixing 11 KV Triping Coil AC/DC |
| 26 | Providing & Fixing 11 KV Closing Coil AC/DC |
| 27 | Providing & Fixing 33 KV Triping Coil AC/DC |
| 28 | Providing & Fixing 33 KV Closing Coil AC/DC |
| 29 | Piercing Connector |
| 30 | winding Temparature indicator 6\" Dia Having range 0-120 cm with MRP pointer 5 mtr long PVCC Capillary and brass contact suitable for 33/811 s/s for 05/10 MVA T/f |
| 31 | Oil Temparature indicator 6\" Dia Having range 0-120 cm with MRP pointer 5 mtr long PVCC Capillary and brass contact suitable for 33/811 s/s for 05/10 MVA T/f |
| 32 | 11 KV numerical communicable Triple pole IDMT non Directional having 3 O/C+ 1E/F, O-C Element 50-200% of I.A. E/F Element (0-40% of m 0-10 sec. The Realy shall be draw out with CT shorting having inrush blocking and 1 open Circuit Spervision feature as per PVVNL Specification |
| 33 | 33 KV numerical communicable Triple pole IDMT non Directional having 3 O/C+ 1E/F, O-C Element 50-200% of I.A. E/F Element (0-40% of m 0-10 sec. The Realy shall be draw out with CT shorting having inrush blocking and 1 open Circuit Spervision feature as per PVVNL Specification |
| 34 | 33 KV Master Relay 03 No. 3 NC |
| 35 | 11 KV Master Relay 03 No. 3 NC |
| 36 | Earthing of Panel |
| 37 | Sundry Item |
| 38 | Hk.Mkj dsUnz lsa izkIr dh x;h fuEufyf[kr lkexzh miyC/k djkuk ,oa lkbZV ij vko\";drkuqlkj yxkus dk dk;ZA |
| 39 | 33 KV Lightening Arrestor |
| 40 | 33 KV CT |
| 41 | 33 KV PT |
| 42 | Distribution T/F L.A |
| 43 | Earthing of pole by MS Erathing Road 20x2500mm & 6SWG Earthing wire etc. |
| 44 | 11 KV TPMO with Polymeric Insulator |
| 45 | 33 KV TPMO |
| 46 | 33 KV Post Insulator |
| 47 | 11 KV Fuse Set |
| 48 | 33 KV Fuse Set |
| 49 | 33 KV Bus Isolator |
| 50 | 3 Phase Distrubution Box |
| 51 | Bettery Set 24 Volt & Battery Charger |
| 52 | 33 KV Line Isolator |
| 53 | 33 KV VCB 800A,. 750A with CT 400/200/1-A with CT Structure |
| 54 | Control Cable 2x2.5 mm. sq. |
| 55 | Control Cable 4x2.5 mm. sq. |
| 56 | 33 KV Control Panel for Double T/f |
| 57 | lkbZV ls mrkjh x;h fuEufyf[kr lkexzh dks lqjf{kr fo|qr HkMkj dsUnz cMkSr@ckxir igqpkus dk dk;Z ¼yksfMax vuyksfMax lfgr½ |
| 58 | Damage CT/PT |
| 59 | Bettery Set 24 Volt & Battery Charger old and use |
| 60 | 33 KV VCB Scrape |
| 61 | Iron Scrape |
| 62 | Fuse Set |
| 63 | TPMO Scrape |
| 64 | Isolator Scrape |
| 65 | Control Panel Scrape |
| 66 | uksV&1- leLr dk;Z jsLiksa ekudksa ds vuqlkj djuk gksxkA 2- mijksDr dk;Z dz0la0 01 ls 65 rd dh ek=k iw.kZr% vuqekfur gS ,oa dk;Z dh vo\";drkuqlkj fdlh Hkh dk;Z dh ek=k \"kwU; ls vf/kdre ¼fufonk /kujkf\"k dh lhek ds vUnj½ gks ldrk gSA3- mijksDr dk;Z esa vkbZVe okbZt izpfyr@ekfdZV jsV izkIr uk gksus dh n\"kk esa vkbZVe okbZt fuxksf\"k,slu djk;k tk;sxkA 4- mijksDr dk;Z l{ke vf/kdkjh }kjk Lohd`r iSdst ds vUrxZr djk;k tk;sxk rFkk mlh ds vk/kkj ij dk;Z dh ek=k ?kVk;h@c |