| 1 | Supply ofPVC insulated and FR PVC Sheathed multicore copper conductor 1.1KV grade, conforming to grade IS 694 as required . 3*1.5 Sq.mm |
| 2 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories,andprovidingmasonryenclosurewithcoverplate having locking arrangement and watering pipe etc. (but withoutcharcoal/ coke and salt) as required. |
| 3 | Providing and Fixing 6 SWG dia G.I. wire on surface or in recess forloopearthingalongwithexistingsurface/recessed conduit/submain wiring/ cable as required. |
| 4 | LayingofonenumberPVCinsulatedandPVCsheathed/ XLPE powercableof1.1KVgradeoffollowingsizeinthe existing RCC/HUME/ METAL pipe as required.Up to 35 sq.mm. |
| 5 | LayingofonenumberPVCinsulatedandPVCsheathed/ XLPE powercableof1.1KVgradeoffollowingsizeinthe existing masonry open ductas required.Up to 35 sq.mm. |
| 6 | Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres lengthalong the pole for protection of under ground cable as required. |
| 7 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) includingexcavationandrefillingthe trenchbutexcludingsand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 8 | Fabrication, supply & erection of 5.0 mtr height, minimum 3 mm thick, bottom diaof 130mm& topdie of70mm, base plate of size 225 x 225 x 12 mm thick flange mounted hot dipgalvanized octagonalpolemadefromHTsteelplate, windowwithflash coverwithfullverticalwindowcoverat appropriate height from the base plate on existing cement concrete pedestal as required. Uc supplying and fitting of 6 mm thick laminated mounted sheet inside the window and I/cprovidingandwelding3nos.Gl strips4mmthickof suitablelengthandhavingsuitablesize tappedholesas reqd, terminal block suitable for 25 sq mm conductor 4 nos. & shorting links on DIN channel Uc providing and fixing DIN channel of suitable length,6 Amp.SPMCB \"C\" Curve characteristics, earth stud, cable support clamp suitable for upto4x25sqmmcable.Logo/Nameofmanufacturershall be either embossed or Riveted plate on the pole.Galvanization as per relevant lS code etc es required |
| 9 | Supplying,installation,Testing&CommissioningofStreetlight LED fixture powder coated pressure die cast aluminum body with driveraspertherequirementwithDriverefficiency>85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80, under voltage andovervoltageprotection,EMIEMCAsper CISPR-15,lenses forbeamangleasperIESNAtypeI/II/III asperthewidthofthe road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As perANSI (min),SDCM(Standard Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respecti/cconnectionswith1.5sqmmFRLS,PVCinsulated copper conductorsingle corecable andearthing etc.as required with Minimum 5 yearOEM warranty System lumenefficacy ≥120 <135lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housingsuchthatLED junctiontemperatureshallnotrise above 90°C). 72 watt |
| 10 | Supply of XLPE insulated and PVC Sheathed Alconductor armoured cable 1.1KV grade confirming to IS-7098. a) 2Cx10 sqmm. |
| 11 | Supply and fixing of 32mm dia X 1 meter long G.I. Pipe (Medium Class)bracketformountingofuorescent/HPMV/HPSVStreet Lightfittingonpoleincludingbendingthepipetothe required shape , 2 nos 25mm X 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd |
| 12 | Fabrication, supplying and fixing class B galvanised single overhang armbracket made out of250mmlong galvanised top tube with cap and 250mm long 32 mm dia galvanised pipe withtightening bolts complete as required. |
| 13 | Fabrication, supplying and fixing class B galvanised double overhang arm bracket made out of 250 mm long galvanized top tube with cap and 250 mm long 32 mm dia galvanized pipe with tightening bolts complete as required. |
| 14 | ProvidingandlayinginpositionM25gradereinforcedcement concrete foundation of size 450 mm (L) ×450 mm wide and 1000 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia- 960mmlong(approx)-8nos.andreinforcementofcold twisted barsof8mmdia-1400mm(approx)-6nos.(with150 mm spacing) as required with supplying and positioning of 4 nos. foundationbolts 16mmdia,600mmlong,Jtypei/c2nos. template anchor plates of size 225mm×225mm×3mm and providing DCW HDPE for cable entry and exit as required for 3 mand 5 mtr pole. |