| 1 | 1) Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing : |
| 2 | a) 1:5:10 (1 cement : 5 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 10 graded stone aggregate 40 mm nominal size Recycled Aggregate (RA)). |
| 3 | 2 )Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 4 | a) 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 5 | 3) Centering and shuttering including strutting, propping etc. and removal of form for : |
| 6 | a) Suspended floors, roofs, landings, balconies and access platform |
| 7 | 4) Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 8 | a) Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 9 | 5) Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in foundation and plinth in: |
| 10 | a) Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 11 | 6)Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in foundations and plinth in : |
| 12 | a) Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 13 | 7) Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.ird course of half brick masonry. |
| 14 | 8) Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 15 | a) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble |
| 16 | i) Area of slab upto 0.50 sqm |
| 17 | b) Granite stone slab colour black, Cherry/Ruby red |
| 18 | i) Area of slab over 0.50 sqm |
| 19 | 9) Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 20 | a) Marble work |
| 21 | b) Granite work |
| 22 | 10) Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete |
| 23 | 11) Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut granite for Counter top of approved size for fixing wash basins fixed to walls by making required chasis and brackets of approved size and make including grining of edges all complete as per the directions of Engineer Iin-charge at all levels. |
| 24 | 12) Providing and fixing Ist quality rectified ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 25 | 13) Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. |
| 26 | After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. |
| 27 | Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS:16231 shall be paid separately. |
| 28 | Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for: |
| 29 | (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3 |
| 30 | (ii) Sites with structure height more than 20m for all wind speeds. |
| 31 | a) Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. |
| 32 | i) Using R2 series with frame (40mm & above) x (40mm & above) & sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto 1.2 meter) |
| 33 | b) Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. |
| 34 | i) Using R3 series with frame (98mm & above) x (40mm & above) & both glazed and fly screen sash (30mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system, (Height upto 1.8m). |
| 35 | 14). Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 36 | a) Fixed to steel windows by welding |
| 37 | 15) Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 38 | 16) Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 39 | a) Double charge vitrified tile polished finish of size |
| 40 | i) Size of Tile 600 x 600 mm |
| 41 | 17) 12 mm cement plaster of mix : |
| 42 | a) 1:6 (1 cement: 6 fine sand) |
| 43 | 18) 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 44 | a) 1:6 (1 cement: 6 fine sand) |
| 45 | 19) Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 46 | 20) Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 47 | a) Two coats. |
| 48 | 21) Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-charge. |
| 49 | a) With cement mortar 1:4 (1 cement : 4 fine sand). |
| 50 | 22) Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer in-charge |
| 51 | 23) Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. |
| 52 | 24) Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge. |
| 53 | 25) Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer in-Charge. |
| 54 | a) Internal Work- Exposed on wall |
| 55 | 26) Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 56 | a) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 57 | 27) Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 58 | 28) Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. |
| 59 | a) In cement mortar |
| 60 | 29) Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 61 | a) Of area 3 sq. metres and below |
| 62 | 30) Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 63 | a) For thickness of tiles 10 mm to 25 mm |
| 64 | 31) Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50metres lead : |
| 65 | a) Thickness above 10 mm up to 25 mm |
| 66 | 32 Dismantling precast concrete or stone slabs in walls, partition walls etc. including stacking within 50 metres lead : |
| 67 | a) Thickness up to 40 mm |
| 68 | 33) Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : |
| 69 | a) 75 to 80 mm dia pipe. |
| 70 | 34) Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: |
| 71 | a) Up to 150 mm diameter |
| 72 | 35) Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 73 | 36) Providing and fixing white vitreous china counter top wash basin of Jaquar or equivalent make of approved size complete in all respect as per directions of Engineer-in-Charge. |
| 74 | 37) Providing and fixing Jaquar OPAL PRIME Series Table Mounted Regular BASIN MIXER (HOT & COLD MIXER) (Chrome) of Jaquar or equivalent make of approved size complete in all respect as per directions of Engineer-in-Charge. |
| 75 | 38) Providing and fixing Stainless Steelkitchen sink as per IS:13983 of approved brand and size with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 76 | 39) Providing and fixing Health faucet of Jaquar ALD-BCH-573-Black Chrome or equivalnet with flexible tube with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. |
| 77 | 40) Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 78 | 41) Providing and fixing 2 stage corner glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 79 | 42) Providing and fixing toilet paper holderof Jaquar make or equivalent as per the directions of Engineer -in-charge all complete |
| 80 | 43) Providing and fixing towel ring of jaquar make or equivalent as per the directions of Engineer -in-charge all complete |
| 81 | 44) Providing and fixing JAQUAR AKP-CHR-35735P Soap Dispenser of Jaquar or equivalent make of standard shape with bracket of the same materials with snap fittings of approved quality and colour. |
| 82 | 45) Providing and fixing china extended wall mounted water closet of Jaquar or equivalent approved brand shape, size and pattern including all fittings and fixtures with seat cover and fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. |
| 83 | 46) Providing and fixing water diverter of Jaquar or equivalent approved brand shape, size and pattern including all fittings and fixtures with fittings, nuts, bolts etc including making connection with the existing water closet, complete in all respect as per directions of Engineer-in-Charge. |
| 84 | 47) Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. |
| 85 | a) 20 mm nominal outer dia. Pipes. |
| 86 | 48) Providing and fixing Jaquar made or equivalent Tap for Kitchen sinkof approved quality. |
| 87 | 49) Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 88 | 50) Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: |
| 89 | (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. |
| 90 | (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. |
| 91 | (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. |
| 92 | (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). |
| 93 | 51) Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have minimum Humidity Resistance (RH) of 99%, minimum Light Reflectance = 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of minimum 0.30 mm thick (minimum galvanized @120 gsm) having rotary stitched double webbed white with 6mm reveal Silhouette profile (white/black) comprising of main T runners of minimum 15x38 mm of length 3000 mm, cross T of size minimum 15x38mm of length 1200 mm and secondary intermediate cross T of size minimum 15x38 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (minimum galvanised @ 80 gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, |
| 94 | spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size minimum 24x24X3000 mm made of minimum 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the Engineer-in charge. |
| 95 | a) With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC minimum0.55 to 0.60) |
| 96 | 52) Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, etc,all as per direction of Engineer-In- Charge. |
| 97 | a) 30 mm thick |
| 98 | 53) Providing and fixing unplasticised Rigid PVC floor trap conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, including cost of cutting and making good the walls and floors : (a) 100 mm inlet and 75 mm outlet |
| 99 | 54) Providing and fixing Jaquar or equivalent make two way bib cock 15 mm nominal bore. of approved quality of quality and make as approved by Engineer - in - charge. |
| 100 | 55) Providing & fixing Type BSWR PVC pipes by cutting, removing, replacingincluding jointing with \"T\" shaped seal/rubber ring conforming to IS : 5382 and with solvent cement or rubber lubricant as the case may be with pipes of outer dia (concealed pipe joints to be jointed with rubber ring and solvent cement and exposed joints to be jointed with rubber ring and rubber lubricant. |
| 101 | a) 75mm diameter |
| 102 | b) 100mm diameter |
| 103 | 56) Providing & fixing sanitary fittings/ accessories with new PVC SWR fittings / accessories including cutting, replacing, jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. |
| 104 | a) Plain Bend |
| 105 | i) 75mm diameter |
| 106 | b) Tee with door |
| 107 | i) 75X75X75 |
| 108 | c) Y- with door |
| 109 | i) 75mm diameter |
| 110 | 57) Providing and fixing Jaquar OHS-CHR-1667 Overhead Shower – 120x120mm Square Shape, Single Flow, Chrome Finish, Stainless steel or equivalent make as per site requirement and as directed by the Engineer in charge. |
| 111 | 58) Providing and fixing Jaquar Opal prime High Flow diverter Full brass set of hot and cold mixture or equivalent make as per site requirement and as directed by the Engineer in charge. |
| 112 | 59) Providing and fixing 32 mm dia PVC rigid pipe forsink as waste pipe. The pipe shall be of length upto 600mm including P.V.C. waste fittings, P.V.C bend, union etc and fixing the pipewith clamps on wall surface, etc., complete all as per site requirement and as directed by the Engineer in charge. |
| 113 | 60) Providing and fixing 50 mm dia rigid PVC pipe as drain pipe near sink. The pipe shall be fitted on the wall surface with necessary clamps at suitable intervals. Necessary diameter PVC \"TEE\" (REDUCER TEE) shall be fixed in this pipe line and arrangements shall be made such that the 32 mm dia waste pipe from the sink shall be fixed properly in this 50 mm dia pipe ensuring proper draining. All complete and as per directions of the Engineer - in - charge. The 50 mm dia pipe shall be measured for payment and nothing extra shall be paid on any account. |
| 114 | 61) Providing and fixing CP brass grating of approved quality and colour. (a)Circular type.(i) 100 mm nominal dia. |
| 115 | 62) Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 116 | 63) Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. |
| 117 | 64) Rebate for taking away the unserviceable water supply lines/fittings including removing from the existing position . etc., complete. |
| 118 | a) GI pipes 15mm/20mm/ 25mm/ 32mm /40mm |
| 119 | 65) Rebate for taking away the unserviceable SCI pipesand fittings etc., complete. |
| 120 | a) SCI pipes |
| 121 | i) 100mm |
| 122 | ii) 75mm |
| 123 | 66) Rebate for taking away the unserviceable wooden Doors, windows, ventilators etc., complete. |
| 124 | 67) Providing and fixing modular kitchen with the following broad specifications :(i) Kitchenbase unit countertop height is 750 mm from the floor - Type :, Box, Plywood : 16mm calibrated BWP ply - LAMINATE : HGL laminate (1mm) - LINER : 0.72mm liners - HINGES: Sleek SS hinges (Rust free) - HANDLES : G profile with end caps, STANDARD DEPTH - 600MM |
| 125 | ii) Kitchenwall unit upper cabinets to be placed 450 mm above the countertop- Type : Box, Plywood : 16mm calibrated BWP ply - LAMINATE : HGL laminate (1mm) - LINER : 0.72mm liners - HINGES: Sleek SS hinges (Rust free) - HANDLES : G profile with end caps, STANDARD DEPTH - 350MM |
| 126 | (iii) Kitchen Hardware - SS Thali & cup saucer inlet/cutlery inlet -500mm depth. |
| 127 | (iv) Sleek slim SS/tandem box - 4 inch/8 inch - 500mm depth |
| 128 | (v) SS Bottle pullout 3 tier 200mm |
| 129 | Average Rate shall be quotedper sqm for modular kitchen keeping in view the approved Architectural drawing.The rate shall be quoted for elevational area per sqm for modular kitchen having broad specifications as listed above and as per the instructions and approval of the Engineer-in-charge. |