| 1 | Dismantaling of bottom wheels of size 200mm dia & 100 mm width for inspection of hangar\"s door panel and re-fixing after checking the serviceability of the wheels, bearings, shaft, nut bolts, wheel box etc complete all as specified and directed. Note:- (i)The work shall be carried out by the rep of manufacturer’s of Hangar Door as given below.(ii)Each panel consists two Nos of bottom wheels.(iii)All the welding work included for fixing of bottom wheel is deemed to be included in quoted rates.(iv)Cost of Necessary tools and plants such as ladders, hydra for repair/fixing etc shall be deemed to be included in the unit rate quoted.(v)The spare parts used for repair is measured and paid separetaly in appropriate item of schedule.Manufacturer’s :- RCC Eco-Build System Ltd/ Jugapro/ Anubhav Power & Control/ Kanti Automatics System. |
| 2 | Dismantaling of bottom wheels of size 200mm dia & 100 mm width for inspection of hangar\"s door panel and refixing after checking the serviceability of the wheels consist with teeth on peripheral of wheel and directly connected to gear box through chain pully arrangement, bearings, shaft, nut bolts, wheel box etc complete all as specified and directed.Note:- (i)The work shall be carried out by the rep of manufacturer’s of Hangar Door as given below.(ii)All the welding work included for fixing of bottom wheel is deemed to be included in quoted rates.(iii)Cost of Necessary tools and plants such as ladders, hydra for repair/fixing etc shall be deemed to be included in the unit rate quoted.(iv)The spare parts used for repair is measured and paid separetaly in appropriate item of schedule.(v)Damaged peripheral teeth of wheel will be replaced with new and rate is deemded to be included in quoted rates.Manufacturer’s :- RCC Eco-Build System Ltd/ Jugapro/ Anubhav Power & Control/ Kanti Automatics System |
| 3 | M & L for smoothing the outer rough surface of wheels by lathe work or electric machine work to enable wheels movement on rail track smooth and functional complete all as specified and directed. |
| 4 | Supply, fabricating and fixing sheet cladding near bottom wheels (2 Nos of wheels) Each of size 300mm x 100mm x 3mm of motorised hanger door panel complete all as specified and directed. |
| 5 | S & F in renewal of ball bearings of each bottom wheel for suitable size and strength as per existing complete all as specified and directed. |
| 6 | S & F in renewal of bottom iron wheel shaft of wheels as well as nuts, bolt etc. as per existing complete all as specified and directed. |
| 7 | M & L for repairing of existing upper roller of hangar motorised door panel of size 70mmX50mm for repair of unserviceable part and fixing after repair/servicing complete roller as per existing included the followings:-(i) The work should be carried out by authorised agency/ contractor which has completed work in provision of Hanger Door field.(ii) All the welding work included for fixing of upper roller is deemed to be included in quoted rates. (iii) Cost of Necessary tools and plants such as ladders, hydra for repair/fixing etc shall be deemed to be included in the unit rate quoted. (iv) The spare parts used for repair is measured and paid separetaly in appropriate item of schedule.Make :- RCC Eco-Build System Ltd/ Jugapro/ Anubhav Power & Control/ Kanti Automatics System. |
| 8 | M & L for smoothing the outer rough surface of roller by lathe work or electric machine work to enable wheels movements on upper track is smooth and functional complete all as specified and directed. |
| 9 | S & F in renewal of ball bearings of upper roller of suitable size and strength as per existing complete all as specified and directed. |
| 10 | S & F in replacement of top iron roller shaft of roller as well as nuts, bolt etc. as per existing complete all as specified and directed. |
| 11 | M & L for fixing MS supporting roller base plate of size 150 mm width, thickness 7.00mm at each door panel (7 Nos at each panel) complete all as specified and directed. Note :- (i) All the welding work included for reapir/fixing for top base plate is deemed to be included in quoted rates. (ii) The Hydra machine, Ladder, Tools etc are included in the quotated rates. |
| 12 | S & F in renewal of door support top and bottom made of MS Clamp fixed/ welded on door panel as per existing shape and size complete all as specified and directed. |
| 13 | S & F in renewal of bottom door Track cleaner brush fixed on bottom of door panel as per existing shape and size complete all as specified and directed. |
| 14 | Cleaning of door track with use of chisel/brush/Electric machine etc for smooth movements of door panels on the track of length approx 500 RM complete all as specified and directed.Note :-Cement concrete/PCC work whenever is required under above item, where the surface / track is damped/blocks or not smooth the same shall be repaired and the quoted rate of item shall be deemed to be inclusive of this aspect. |
| 15 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including Naintal or similar pattern roof coverings complete all as specified anddirected. |
| 16 | M & L for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm of sand colour having tensile strength of 550Mpa as in roof covering/cladding to wall, velley gutter fixed with self tapping screws as complete all as specified anddirected. |
| 17 | M&L for Cutting existing loose patches/spalled edges, widening of existing cracks of concrete pavement in true geometrical shapes to average depth of 50mm using diamond cutters operated with gen sets, cleaning the surface dry and free from dust/dirt with air compressor in order to achieve proper bond between elastomeric concrete and cement concrete surface and applying polyurethane based elastomeric concrete over a coat of approved primer as per manufacturer\"s instructions including supply and fixing masking tape on pavement surface to prevent accidental spillage of elastomeric concrete and removing the masking tape and cleaning the area of application after the application is over complete all as specified and directed. |
| 18 | M & L for alignment of guide rail including all necessary repair/replacement works complete all as specified and directed. |
| 19 | Dismantaling all the mechanical and electrical connection of hangars Door panel for opening of chain pulley and gear assembly from bottom wheels of hangars door panel for repair/replacement of unserviceable parts such as chain, gear box, rubber, washer, nuts, bolt, iron handle suitable for gear box, Manual shaft etc and fixing after repair/repalcement & complete servicing as per exixsting included the followings :- (i) The minor/major part of gear box for repair/replacement is deemded to be included in quotated rates. (ii) All the welding work included for reapir/fixing for bottom wheel is deemded to be included in quoted rates. (iii) Cost of Necessary tools and plants such as ladders, hydra for repair etc shall be deemed to be included in the unit rate quoted. |
| 20 | S&F inrenwaldouble door sheet metal enclosuremade out of CRCA mild steel sheet concealed surface mounting TPN, 4 way, 415 Volt, suitable for fixing MCBs, isolators etcincluding taking down old complete all as specified and directed. |
| 21 | S&F in renewal MCB TPN 63 Amps C curves MCB repturing capacity 10 KA etc complete all as specified and as directed. |
| 22 | S&F in renewal MCB TPN 40 Amps C curves MCB repturing capacity 10 KA etc complete all as specified and asdirected. |
| 23 | S&F in renewal MCB TPN 32 Amps C curves MCB repturing capacity 10 KA etc complete all as specified and asdirected. |
| 24 | S&F in renewal MCBSPN 40 AmpB curves MCB repturing capacity 10 KA etc complete all as specified and directed |
| 25 | &F in renewal MCBSP 6 to 32 AmpC curves MCB repturing capacity 10 KA etc complete all as specified and asdirected. |
| 26 | S&F in renwal aviation obstruction light die-cast aluminium alloy housing,red coloured polycarbonate dome and accessories complete all as specified and as directed . Note :- Cost of Necessary tools and plants such as ladders, hydra for repair/ fixingetc shall be deemed to be included in the unit rate quoted. |
| 27 | &L for making of surface for painting duly scrubing the existing paint and apply of two coats of existing synthetic enamel paint over a coat of red oxide primer for 3 Ph motor andgear box of hanger doorcomplete all as specified and directed |
| 28 | S&F in replacement of volt meter 0 --500 volt digital type square complete all as specified and as directed |
| 29 | S&F in replacement of Ammeter 0 --200 Amp digital type squarecomplete all as specified and as directed |
| 30 | S&F in replacement power contactor 415 volt, 50 Hz, 3 phase,MNX12 type suitable for fixing in Control board panel complete all as specified and as directed. |
| 31 | S&F in replacement power contactor 415 volt, 50 Hz, 3 phase,MNX A1 type25 Asuitable for fixing in automation board panel complete all as specified and as directed. |
| 32 | S&F in replacement of single phase preventer suitable for fixing in automation board panel complete all as specified and as directed. |
| 33 | S&F in replacement over load relay 14-23 A suitable for fixing in Control board panel complete all as specified and as directed. |
| 34 | S&F in replacement power contactor 415 volt, 50 Hz, 3 phase,MNX 9 type suitable for fixing in Control board panel complete all as specified and as directed. |
| 35 | S&F in replacement Indication lamp (RYB)complete all as specified and as directed. |
| 36 | Supply, installing, testing and commissioning in renewal of factory made main control board pane of size 1000mm x 500mm x 1000mm, indoor type, metal enclosed fixed type, free standing, floor mounting, compartmentalized, modular type and suitable for indoor installation, factory assembled in bolted design fabricated from 2.0mm thick CRCA sheet steel frame work and including painting with two coat of synthetic enameled paint, degree of protection IP-54 as per IS-13947, consisting high conductivity bus aluminium bus bar of suitable size with heat shrinkable sleeves & inculding multifunctional digital voltmeter with suitable cable of suitable size complete all as specified & directed and consiting of followings :- (i) MCB, TPN 63 Amp, \"C\" curve, 10 kA - 01 No (ii) MCB, TPN 40 Amp, \"C\" curve, 10 kA - 03 Nos(iii) Contactor, MNX 12, 415 V - 06 Nos(iv) Relay, 220-240 VAC - 03 Nos(v) Overload Relay (14 - 23 Amps), Direct Mounting on MNX 9-40 A - 1 No (vi) Single Phase Preventer - 01 No (vii) MCB-10 Amp,C Curve - 01 No(viii) Indicator (RYB)- 01 Set(ix) Digital Voltmeter (0-500 Volt) - 01 Set |
| 37 | S & F in renewal of factory made automation panel board, indoor type, of size 600mm x 600mm x 300mm metal enclosed fixed on wall or MS ploe with suitable arrangement like nut, bolt/welding etc suitable for indoor installation, factory assembled in bolted design fabricated from 2.0 mm thick CRCA sheet steel frame work and including painting with two coat of synthetic enameled paint, degree of protection IP-54 as per IS-13947, which controls the operations of 3 Nos of 3 HP existing electricalmotors, Limit switchs, hooters /blinker, Emergency switchs etc., and the automation panel board is directly connected with Main Control panel board through suitable size of cable and suitalble size of length complete all as specified & directed and comprises the followings:- (i) Forward switch - 03 Nos(ii) Reverse Switch - 03 Nos(iii) Stop switch - 03 Nos (iv) Forward switch indicator - 03 Nos(v) Reverse switch indicator - 03 Nos(vi) Stop switch indicator - 03 Nos(vii) Tripping indicator - 03 Nos (viii) Emergency switch - 01 No Note :- The Forward/reverse/Stop switches and indicators is directly linked with Limit switches and for operartion of electric driven three thase motor. |
| 38 | S & F in renewal, installing, adjusting Heavy Duty Limit Switches as existing with IP 67 degree of protection for Motor operated hangars Doors, complete all as specified and directed. |
| 39 | S & F in renewal, mounting and installing Hooter / Blinker on top of automation panel complete all as specified and directed. |
| 40 | M & L for disconnecting the unserviceable, burnt existing electric motor 3 HP capacity, 3 phase from gear box of hangars doors and re-winding with super enamelled copper wire of existing size & make and re-fixing the same complete all as specified and directed. |
| 41 | S & F in repalcement of copper cable confirming to IS 694:1990, FRLSH, 1100 Volt, 1.5 Sqmm, 2 core cable & including PVC conduit of size not less than 20 mm, heavy duty, (ISI marked), which is fixed to clamp with hangars door panel or fixed on cable tray etc complete all as specified and directed.Note :- (i) The cable is connected between limit switches and remote panel to Hooters/Blinker.(ii) Cost of Necessary tools and plants such as ladders, hydra for repair etc shall be deemed to be included in the unit rate quoted. (iii) The one unit length of PVC Conduit of size not less than 40 mm and one unit length of said 2 core cable is measured as one unit length. |
| 42 | S & F in repalcement of copper cable confirming to IS 694:1990, FRLSH, 1100 Volt, 2.5 Sqmm, 4 core cable & including clamping on cable tray/ Door panel etc complete all as specified and directed.Note :- (i) The cable is connected between Remote panel and Electric motor.(ii) Cost of Necessary tools and plants such as ladders, hydra for repair etc shall be deemed to be included in the unit rate quoted. |
| 43 | Supply and fixing in replacement of U/Sflood light luminaire of HPSV/MH,with LED flood light fitting consist of PDC aluminium houseing in powder coated dia costing power coted in gray finish,high power LED with IP 66protection, fins are provided on housing ,heat resistant tempered glass for protectionwith 5 kv surge protection of 150 W LED as specified and directed. |
| 44 | S&F in replacement of HPSV/MH High bay light fitting with highbay luminare LED light fitting 200 watts, system wattage: 200 W, Lumen package : 24000 Lm, luminaire efficacy:> 120 Lm/W, four stage electrical protection : over/under voltage protection, short circuit and reverse polarity protection, Over temperature protection, Die-cast aluminium housing with dedicated optics for excellant beam distribution, Life: 50000 Hrs @L70, color temperature : 5700K + 300K, surge protection of internal 4kV and external 4kV complete all as specified and directed. Note:- Cost of neccessary tools and plants such as ladders, hydra for repair of high raised high bay / medium bay / low bay luminaires, suitable hanging items such as clamps/hooks/down rod etc should be deemed to be included in the unit rate quoted. |
| 45 | M & L for earthing with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep below normal ground level), with top edge of the plate vertically to depth of not less than 1.5 m below normal ground level connected to and incl GI strip 25x4 mm and GI pipe 40 mm dia light grade for protection to the extent of 7.5 m as earthing lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Pt-I incl PCC cover and , watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit incl excavation and earth work in any type of soil and testing on completion etc complete all as specified and directed.Note: (i) Excavation earthwork charcoal PCC pit is covered under this item including taking out existing earth plate etc. complete all as specified and directed.(ii) The unit rate includes for protection pipe and GI strip 25 x 4mm from top of earth plate up to 7.5 meter above ground level.(iii)PCC chamber shall be constructed at least 1.5m away from earth pit pipe for watering shall be provided in slanting manner. |