| 1 | Taking up/down of old U/S LT armoured cable and Supplying, laying, commisioning and testing of 1.1 KV grade XLPE insulated PVC sheathed steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 7098) ISI marked in trenches / ducts / through GI pipes under roads of size 16 sqmm 4 core complete all as specifed and directed. Note;- The earth work, GI pipe shall be measured and paid sepretely under appropriate item of Sch A |
| 2 | All as per Item No 1 here in before but Cable of size 50 Sqmm 3.5 Core complete all as specified and directed. |
| 3 | Excavation in trenches in soft/disintegrated soil not exc 1.5mtr wide and not exc. 1.5mtr depth for laying of UG Cable/foundation etc complete all as specified and directed |
| 4 | Returning filling in soft/disintegrated soil including spreading levelling watering and well ramming in layers n exc 25cm each layer complte all as pecified and directed. |
| 5 | Removal of excavated surplus soft/disintegrated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 6 | M&L for sand cushioning for under ground cable with layer of fine river dry sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed by Engg-in-Charge. Note:- Punned (consolidated ) thicness of sand will be measured and paid. |
| 7 | M&L for cable protection bricks common burnt clay sub class B designation 75 for protectioon of UG Cable laid in trenches complete all as specified and directed. |
| 8 | S&F in replacement of MCCB 4 pole, 415 volt , adjustable thermal and magnetic release type 250 Amp breaking capacity 36 KAcomplete all as specified and directed. |
| 9 | S&F in replacement of MCCB 4 pole, 415 volt , adjustable thermal and magnetic release type 160 Amp breaking capacity 36 KAcomplete all as specified and directed. |
| 10 | S&F in replacement of MCCB 4 pole, 415 volt , adjustable thermal and magnetic release type 100 Amp breaking capacity 25 KAcomplete all as specified and directed. |
| 11 | Supply and straingin replacement of over head ACSR conductor any size i.e weasel, Ferret and Dog and any type including binding/jointingthe conductor to insulator with binding wire complete all as specified and directed. |
| 12 | Dismantling insulators any type, any size complete all as specified and directed. |
| 13 | Supply & fixingpin type composite polymer insulator including one galvanised mild steel spindle , two galvanised iron washer and one galvanised iron nut,suitable for 1100V grade complete all as specified and directed |
| 14 | Dismantling and taking out old unserviceable/ broken PCC pole and struts of any size including clamps insulators, cross arms etc of any type complete all as specified and directed. |
| 15 | Supply, transporting, erection and fixing steel tubular swaged pole, 09 metres long, type 410 SP-31, complete with MS base plate 6 mm thick, pole cap, finial taper plug, bolts, nuts, washers etc includingnecessary earth work and excavation, PCC in foundation 1:4:8 type D-2, using 40 mm graded stone aggregate and PCC 1:3:6 type C-2, using 40 mm graded stone aggregate as in plinth block, disposal of surplus soil to a distance not exceeding 50 m, painting two coats of aluminium paint including 5 Nos band/straps with yellow and black colour in alternatete way (200mm wide each)paint two coat at a distance 300mm from plinth block and marking pole nos with black paint including tarring one coat on steel surface embedded in concrete complete all as specified and directed. Note : Required earth work, PCC foundation will be paid separetlyunder relevantitems of Sch A. |
| 16 | M&L for prepration of old treated surface of existing steel tubular poles 8/9 mtr long( upto 1.20 mtr from coping/ground level (whichever is on upper side) incl brackets, clamp cross arms etc with two coat of aluminium paint over one coat of red oxide primer incl writing MES No complete as specified and directed. |
| 17 | M&Lfor refixing of poles in same location or other place as directed after taking out pole from earth, incl transportation if required incl necessary earth work, coping and fixing of existing over headconductor and insulator complete all as specified and directed. |
| 18 | Dismantling stay assembly complete all as specifiedand as directed. |
| 19 | Supply & fixing of stay assembly complete with all accessories, such as stay plate 300x300x6mm, stay rod 215cm long and 16mm dia with nuts including GI Bow turn buckle etc, all as per Electrical Plate No 1 SSR-2009 Part-I complete all as specified and as directed. |
| 20 | M&L in replacement for loop type insulators vitreous porcelain white, brown or green large size with overall dimensions 90x140 mm clearance of hole 25.5mm complete all as specifiedand as directed. |
| 21 | Dismanlting and taking down bend/damaged mild steel work such as cross arms, bracing, supported, clamps & back plates etc complete all as specified and directed. |
| 22 | M&L for cross arms,bracings,supports,clamps and back plates fabricated from structural steel sections including nuts,bolts,washers welding,bending cold or hot drilling holes for bolts in any shape or size as indicated or directed including of one coat of primer and two coat of aluminium paint.complete all as specified and directed. |
| 23 | M&L PCC (1:3:6) type C2 (Using 40mm graded stone aggregte) as in mass concrete/foundation complete all as specified and directed. |
| 24 | M&lPCC 1:2:4, type B2, (using 40mm stone aggregate)in pole foundation bed complete all as specified as direccted. |
| 25 | M&lPCC 1:4:8, type D2, (using 40mm stone aggregate)in pole foundation bed complete all as specified as direccted. |
| 26 | M&L for in repairs 80 mm bore GI tube light grade laid under road/culvert/drain fixed to pole wall with help of flat iron clamps etcfor cable protection and making good surface of road with PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) complete all as specified & directed. |
| 27 | M&L for in repairs 40 mm bore GI tube light grade laid under road/culvert/drain fixed to pole wall with help of flat iron clamps etcfor cable protection and making good surface of road with PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) complete all as specified & directed |
| 28 | Supply and Fixingin repairs LED flood light fitting 150W,including connecting with 1.5 sq mm, 3 core, PVC insulated Copper conductor cable 1100 Volts grade from pole box to light fitting or from overhead conductor to light fitting complete all as specified and directed. |
| 29 | Supply and Fixingin repairs LED flood light fitting 200W,including connecting with 1.5 sq mm, 3 core, PVC insulated Copper conductor cable 1100 Volts grade from pole box to light fitting or from overhead conductor to light fitting complete all as specified and directed. |
| 30 | Supply and Fixingin repairs LED Stret light fitting 45W,including connecting with 1.5 sq mm, 3 core, PVC insulated Copper conductor cable 1100 Volts grade from pole box to light fitting or from overhead conductor to light fitting complete all as specified and directed. |
| 31 | Supply and Fixingin repairs LED Stret light fitting 60W,including connecting with 1.5 sq mm, 3 core, PVC insulated Copper conductor cable 1100 Volts grade from pole box to light fitting or from overhead conductor to light fitting complete all as specified and directed. |
| 32 | S&F in repair Wall Bracket light fitting (Bldg Security light) 20W housing made out of die cast aluminium alloy with tougned glass , IP 65 protection having clamp for mounting on building wall working on 240V AC 50 Hz , 20 Watts, wired with appropriate driver PF>0.90 having over voltage protection up to 400 volts, surge protection level 7 - 10 KV, thermal short circuit protection THD<10%, LED lumen efficiency >120 lumen Per watt, including fixed on wall with 02 Nos MS Clamps made of 40x6 mm FI and bracket made of 40 mm dia light grade GI Pipe bend to shape, not less than 1.2 m long including connecting with 02 single core PVC insulated copper conductor cable 1100 v grade size 1.5 sqmm complete all as specified and directed. |
| 33 | S & F in repair Loop in and Loop out FRP rectangular SMC junction box(Pole Box) front openable hinged from side of size 240x130x95 mm suitable for outdoor installation weather proof having 4 pole cable connector (for cable in and out junction) fixed inside box with insulator support complete for street light fitting with MS clamps of suitable size and GI nuts, bolts and washers complete all as specified and directed. |
| 34 | S&F in repair service cable 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathingof PVC tape and overall PVC sheathed in service connection suspended with insulating hanger not more than 1 mtr apart including 4 mm dia suspension wire alongwith 10 Sqmm twin core flat cable all as specified and directed. |
| 35 | M&L in repair for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required of size 4mm dia galvanised iron or steel wire. |
| 36 | M&L in repair for earth continuity GI Strip of 25 x 4 mm as earth conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required of size 4mm dia galvanised iron or steel wire. |
| 37 | M&L in repair for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground levelat any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 4mm GI wire with check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI strip upto 7.5 mtrs long with 40 mm dia medium grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighing not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items. |
| 38 | M&L in repair for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground levelat any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 25 x 4mm GI stip check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI strip upto 7.5 mtrs long with 40 mm dia medium grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighing not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI strip more than 7.5 mtrs will be measured and paid seperately under relevant items. |