| 1 | M&L for replacement of under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 120 sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testingincluding disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed.Note:- Excavation and earth, sand coushioning and protection for cable work shall be measured and paid separately. |
| 2 | All as per item No. 1 here-in-before but cross-sectional area 70 sqmm, 3.5 core complete. |
| 3 | All as per item No. 1 here-in-before but cross-sectional area 35 sqmm, 3.5 core complete. |
| 4 | All as per item No. 1 here-in-before but cross-sectional area 16 sqmm, 4 core complete. |
| 5 | All as per item No. 1 here-in-before but cross-sectional area 16 sqmm, 2 core complete. |
| 6 | M&L for GI pipe 80 mm dia \"light grade\" ISI marked, laid in trenches/ on floors/on, pole/road for cable protection including necessary joints / fittings including taking up / down and removing old unserviceable GI pipe complete all as specified and directed . |
| 7 | All as per Srl item No 6 here-in-before but 50mm dia |
| 8 | Excavation in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for Pole, shafts, cesspits, manholes, pier holes, etc and getting out of any type of soil complete all as specified and directed. |
| 9 | All as per Item No: 8 above but depth exceeding beyond 1.5mtr and not exc 3 metre all as specified and as directed |
| 10 | Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 11 | Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed. |
| 12 | Material and labour for sand cushioning with fine dry unwashed sand in trenches for protection of cables complete all as specified and directed. |
| 13 | Material and labour for well burnt bricks,Sub class \"B\" bricks, best quality locally available laid flat, dry in trenches for cable protection complete all as specified and as directed |
| 14 | M&L for PCC 1:4:8 type D-2using 40mm graded crushed stone aggregate as in foundation of poles etc including necessary form work, complete all as specified& directed. |
| 15 | M&L for PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as instay etc including necessary form work, complete all as specified & directed. |
| 16 | M&L for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as incoping of pole etc including necessary form work, complete all as specified & directed. |
| 17 | Supply, fixing and erection of steel tubular swaged pole 09 m long, type 410 SP-32, weight not less than 154 kgs, pole should be in one piece only and smooth finishing, ISI marked conforming to IS:2713-1980, complete with all accessories, such as cast iron base plate, finial taper plug, bolts, nuts, screws, washers and drilling of holes for continious GI earth wire as specified including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer and embedded portion shall be painted with two coats of black paint after preparation of surface including taking down old unserviceable pole complete all as specified and directed.Note:-Excavation and earth work shall be measured and paid separately. |
| 18 | Detecting the fault of LT 440 volt overhead/ underground system of any feeder/location with necessary safety,testing equipment, tools and plants and rectify the defects on top priority basis/ as and when required including testing on completion, complete all as specified & directed. |
| 19 | Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x600mm x 6mm thick buried dirctly in ground with earth pit not lesss than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 25 x 4 mm earthing lead by means of nuts bolts check nuts GI washers earth wire protected by GI pipe 32 mm bore, light grade, including concrete pit in PCC (1:3:6) type C1 of size 45x45x45 cm, precast RCC (1:2:4) type B1 as cover of size 40x40x10 cm with one handle for lifting made out of 8 mm dia MS bar, GI funnel wire mesh, 20 mm bore GI pipe, medium grade, for watering, charcoal or coke and salt packed all around in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part-I including testing on completion including demolition to existing one complete all as specifed and directed. (Note :- (i) PCC pit, RCC pit cover, GI earth protection & watering pipe, funnel, earth strip upto 7.5 Mtr etc shall deemed to be included in the unit rate. |
| 20 | M&L for replacement and testing moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, ,4 Pole,415 volts,50Hz,breaking capacity 16KA,rating 63Amp,complete as per OEM standard design,all as specified and as directed by the Engineer in charge. |
| 21 | All as per item No. 20 here-in-before but rating 100Amp & breaking capacity 16KA. |
| 22 | All as per item No. 20 here-in-before but rating 160Amp & breaking capacity 36KA. |
| 23 | All as per item No. 20 here-in-before but rating 200Amp & breaking capacity 36KA. |
| 24 | All as per item No. 20 here-in-before but rating 250Amp & breaking capacity 36KA. |
| 25 | M&L for replacement of stay assembly galvanised iron complete with accessories stay rod 20 mm dia, 180cm long with two nuts, stay bow 14mm dia and 38cm long with stay plate 300x300x6mm thick mild steel stay thimble and required length including binding to insulator stay bow and stay clamp galvanised iron stay strand wire 7/4mm dia, complete all as specified and shown in EP plate No 1 of SSR part-I, complete all as specified and directed.NOTE :- Excavation, earth work and concrete shall be measured and paid separatly |
| 26 | Material and labour for loop type insulator, vitreous porcelain green, white or brown with overall dimension 65mm x 90mm,clearence of hole 16mm complete all as specified and as directed |
| 27 | Taking down carefully ceiling fans at any height of any sweep/ make /model after disconnecting electric connection and dismantling andopening the body of ceiling fan and examine for repairs including servicing,overhauling, greasing etc and cleaning the complete body both internal & external parts with cleaning agent and renewal of minor spare parts such as split pins,cater pins,coupling bolt, capacitor holder,terminal adoptor, screws, nuts, spring washers for blade/body etc and replacement of components/accessories such as ball bearings, gun metal bushes, capacitor, canopy top & bottom, shackle clip assembly and assembling of all parts, remetalling of worn out shaft of fan cutting brazing machining and polishing to make the shaft suitable for fixing of new ball bearing and fixing ball bearing in replacement of bushing system in ceiling fan and assembling the same and testing to the engineer in charge to ensure smooth and noise free operation(bearing shall be measured and paid seperately) including hanging and fixing back in existing location and connecting of electrical connections and testing for its satisfactory performance complete all as specified and directed.(Note:- (i) Spare parts will be measured and paid separately under relevant item of schedule as supply only(ii)Rewinding of fan motor,painting will be measured and paid separetly under relevant item of schedule. (iii)Labour element for fixing of spare parts and removing old unserviceable items are deemed to be included in quoted rate.(iv) All repair works will be carried out at ON site/ workshop E/M yardas directed by EIC.(v)Repair works of fans should completed and refixed the same within 12 hours after receipt of complaint slip.If the complaint not attended /not completed on same day recovery will be done from RAR bill as follows: a) For first day Rs 200 b) For second day Rs 300 c) For next every day Rs 500 |
| 28 | All as per serial item No.01 here-in-before but for exhaust fan of size 300mm/450mm sweep |
| 29 | Material and labour for taking out and removing burnt copper winding, cleaning the armature, rewinding theceiling fan (1200/1400mm sweep) armature/motorwith new super enamelled copper wire of existinggauge including supply and fixing necessary E class insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing all as specified and as directed. |
| 30 | M&L for rewinding of heavy duty exhaust fan motorof300 mm sweep of any make/model/type with new supper enamelled copper winding wire ofsimilar gauge and number of turns and assembling of fan motor and rotor and testingincluding removing burnt out copper winding wire from fan motor complete all as specified and directed. |
| 31 | All as per Item No.30 above but 450mm. |
| 32 | Supply only gun metal bush suitableforceiling fan/Exhaust fan/Air circulator fan /wall mounted fan of any sweep/type of any size(Make - TATA/MSP). |
| 33 | Supply only Ball bearing No.6201/6202/6203/6204 for ceiling fan (Make - TATA/SKF /NBC/NRB). |
| 34 | Supply only fan condensor 2.5 mfd,230 volt,AC 50Hz confirming to IS 1709 for ceiling fan,exhaust fan,wall mounted fan and pedestal fan (Make - USHA/UNIVERSAL/Havells) |
| 35 | Supply only fan condensor 3.15 mfd (Make - USHA/UNIVERSAL/Havells) |
| 36 | Supply & fixing Electronic fan regulator stepped typewith five step ,two module, 100Watt 240 voltscomplete all as directed. |
| 37 | S&F in replacement of modular fan regulator, electronic step type heavy duty modular 2 module230 volts, 120 watt complete all as specified and as directed. |
| 38 | Supply & Replacement of thermostat(Adjustable type) ofRod/stem Type EST-11EM,20A resistive , 250Volt, opening on temperature riseof approved make and having ISI mark all as specified. |
| 39 | Supply & Replacement of steel inner tank suitable for storage type water heater (geyser) 25 litre capacity. |
| 40 | Supply & Replacementsteel siphon geyser assembly 6/9 hole suitable for 25 ltr capacity geysers any make as required at site of approved make complete with inlet and outlet and provision for thermostat pipe with drain pipes with drain plug, glass wool, gasket, screws, studs, clamps for fixing heating elements etc. including in quoted rates all as specified and as directed |
| 41 | Supply & Replacement heating elements of capacity 1.5/2 KW AC 240 volts suitable for storage type electric water heater as per site requirement (press type /screw type/triangular/circular base or ceramic cartige type),ISI marked all as specified and as directed. |
| 42 | Supply & fixingPVC connection pipe 15 mm dia, 450mm long with end nuts and washer, suitable for cold/hot water outlet of geysercompleteall as specified and directed. |
| 43 | Supply & fixing PVC connection pipe 15 mm dia, 600mm long with end nuts and washer, suitable for cold/hot water outlet of geysercompleteall as specified and directed. |
| 44 | S&F of Exhaust Fan plastic body, 250/300mm(8&12\") sweep, single phase, 230 volts 50 Hz AC,1200 RPM, energy saving, heavy duty totally enclosed, heavy duty motor with die-cast aluminiun rotor mounted on two ball bearings complete with louvers and shutters including cutting hole for fixing exhaust fan to wall and making good the disturbed surfaces (including making holes in wall,plastering, necessary brickwork and distempering) to match with the existing specification, connecting electrically using 3 core 0.75 Sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site and as directed.Make: Havells/Bajaj/Crompton |
| 45 | Deduction to be made from BOQ for schedule of credit (Sch \"A\" Part - II) Amount of ₹ 40,077.00during AOCNote:- Tenderers shall not quote for this Schedule |