| 1 | Taking down Shutters of any description exc 1 sq. mand n exc 2 sqm each |
| 2 | Taking down Chowkat or frames with shutters(without taking off shutters from the frames)exc 1.5 but n.exc 4.00 sqm each |
| 3 | Taking down and romoving Chowkats or frames not exc. 1.5 sq.m with shutter (without taking off shutters from the frames)complete all as specified. |
| 4 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premise |
| 5 | Demolition of cement concrete (unreinforced) in ground floors and paving n. exc. 15 cm thickness (below or above ground level) complete all as specified. |
| 6 | Taking down cement plaster on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc.Note the area includs in this up to 4th stories building |
| 7 | S&F powder coating anodised aluminium section for shutter/frame for door, window and ventilator complete all as specified. |
| 8 | S & F powder coated frame sections for doors and windows approved and fixed all as specified and directed. (Note : (i) Paneling such as glass , Gauge etc will be measured and paid saperately.(ii)The rate quoted under this item deemed included for necessary jointing cleates, glazing clips, alluminium beading, screws, rubber packing and locking devices & in built handles for sliding windows. However, no element on account of weight will be taken into consideration for these item.(iii)Floor door spring/locks/tower bolts/ handles/ door closure/hinges for doors measured saparately.(iv) Size of door / windows shall be all as directed at site.(v)Grills will be measured saparately.(vi) Second class hard wood batten of appropriate size to be inserted inside the frame for fixing hinges and the same is included in the rate quoted.) |
| 9 | S & F plain sheet glass 5 mm thick tinted,fixed to aluminium doors/ windows / ventilators complete all as directed by Engr-in-Charge (Note:- Beading/rubber packing is included in the rates for aluminium sections above.) |
| 10 | M&L for Anodised aluminium grill (anodised transparent or dyed to requiredshade according to IS: 1868 with minimum anodic coating of gradeAC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainlesssteel screws @ 200 mm centre to centre, including cutting the grill toproper opening size for fixing and operation of handles and fixingapproved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge. |
| 11 | S & F in repairs 125x60mm size Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinge, lock strike plate, etc. complete as specified. |
| 12 | S & F in repairs 105x60mm size Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinge, lock strike plate, etc. complete as specified. |
| 13 | S&F factory made soild PVC moulded dorr shutter 28 to 30 mm thick(stiles), with 2,4 or 6 raised panel design with 2 mm thick moulded PVC sheet on the front face & 2 mm plain color pvc sheet on back face supplying and fixing in frame complete all as specified and directed |
| 14 | S&F PVC Door Frame for moulded door shutter of size 50mmx47mm made out of 5mm colour PVC sheet reinfoced with MS Square tub, suppling & fixing in opening as per specification and drawing. |
| 15 | S&F 125 mm Butt hinges, meduim weight, cold relled stainless steel and fixed complete all as specified and directed |
| 16 | S & F for aluminium anodised, barrel tower bolts of extruded section 150 mm long and fixed complete all as specified and directed |
| 17 | S&F 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified. |
| 18 | S&F 35 mm thich 2nd class Hard wood Glazed and skelton shutters, open rebated and prepared to receive glass, guaze etc, divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securiing glass etc, sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.20(a) and fitted to chowkats. |
| 19 | S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both side. |
| 20 | S & F for Galvanised mildsteelwire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples |
| 21 | S&F 250mm Aluminium alloy, anodised, sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of exctruded sections or cast aluminium alloy and fixed. |
| 22 | S & F for mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed |
| 23 | M&L Glazed coloured ceramic tiles in vertical surfaces 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick in cement mortar 1:3 on fair faces of brick work or concrete surface as backing coat coat of dado/skirting etc complete all as specified and as directed . |
| 24 | M&L Non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile 0.18 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick Screed bed or bedding layer of mortar for lying floor finished in Cement Mortar 1:4 complete all as specified and as directed . |
| 25 | M&L Non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick Screed bed or bedding layer of mortar for lying floor finished in Cement Mortar 1:4.. |
| 26 | M&L 25mm thick Cement concrete 1:2:4 type B-O(using 12.5mm graded aggregate) as in flooring, finished surfaces even and smooth without using extra cement. |
| 27 | M&L for rendering 15 mm thick in CM (1:3) mixed with water proofing compound @ 3% by weight of cement finishedeven and smooth without using extra cement in sunken portion of toilet etc complete all as specified and as directed Note: WPC will be measured and paid separtely |
| 28 | M&L for two coat of painting with Dr Fixit fast Flex (or equivalent) water proofing liquid including preparation of new plastered surfaces complete all as specified and as directed by Engineer-in-Charge. |
| 29 | M&L cement concrete 1:5:10 type E-2 using 20mm granded crushed Brick aggregates as in sunken portion of WC etc complete all as specified and as directed |
| 30 | Taking up or down steel tubing 15 mm bore, and connections, including cleaning for re-fixing or removal to store in repairscomplete all as specified. |
| 31 | Taking up or down steel tubing 20mm bore, and connections, including cleaning for re-fixing or removal to store in repairscomplete all as specified. |
| 32 | S&F 15 mm bore CPVC tubeswith all fittings and fixed complete to walls and ceilings or laid in floors. |
| 33 | S&F 20 mm bore tubes medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors. |
| 34 | S & F in repairs 15mm bore Bib taps, fancy type chromium plated cast copper alloy with crutch or butterly handle, screwed down, screwed with cupfor iron pipe or for brass ferrule and fixed complete all as specified and directed |
| 35 | S & F in repairs 15mm bore Stop Valve/ angle valve fancy type chromium plated , cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends with cup for iron pipe or for unions and fixed complete all as specified and directed. |
| 36 | S & F in repairs 15mm bore Pillar tapscentral hole Basin mixer with regular spout without popup waste system with 450 mm long braided hosedd 20 mm carttridge size fancy type,cast copper alloy,chromium plated, complete all as specified and directed. |
| 37 | S & F in repair single towel rall 450mm long fancy type chromium plated fixed with PVC plug and steel screw complete all as specified and directed. |
| 38 | S & F in repair towel ring round with round flange fancy type cromium plated fixed with PVC plug and steel screw complete all as specified and directed. |
| 39 | S & F in repair soap dish, vitreous China white, approximate size 160x 160x90mm complete all as specified and directed. |
| 40 | M & L in repair for hand shower (health faucet) with 18mm dia 1.20 m long(min) flexible tube and wall hook complete all as specified and directed. |
| 41 | S & F in repairfor PVC conection 15 mm size with PTMT nuts of length 450 mm long complete all as specified and directed |
| 42 | S & F in repair Swivel shower of PTMT any colour forfixing with 15mm pipe. (Minimum weight40gms complete all as specified and directed. |
| 43 | S&F in repair vitreous China wash basin white, flat back (min size 550x400 mm or as required) including S&F 32mm dia waste coupling, waste PVC pipe complete all as specified and as directed. |
| 44 | S&F in repair vitreous ChinaSquatting pan \"Orrisa\" pattren size(min size 580x440mm) white with integral foot rest, \"P\" or \"S\" trap cement concrete beddingcomplete all as specified and directed. |
| 45 | Supply only 10 Ltr capacity PVC valveless symphonic action type flushing cistern white low level with ball valve float, handle including bracket complete all as specified and directedwith glaged finish. |
| 46 | M&L for 15mm thick Rendering on fair faces of brick work or concrete sureces in Cement Moratar 1:6 finished surface even and smooth without using extra cement.Note the area includs in this up to 4th stories building |
| 47 | M&L for 15mm thick Rendering on fair faces of brick work or concrete sureces in Cement Moratar 1:4 finished surface even and smooth without using extra cement. Note the area includs in this up to 4th stories building |
| 48 | M&L for 10mm thick Rendering on ceiling surface fair faces of brick work or concrete sureces in Cement Moratar 1:3 finished surface even and smooth without using extra cement. Note the area includs in this up to 4th stories building |
| 49 | S& F in repair stain less steel decorative cutrain rod of 25 mm bore inluding 2 nos steel finale and bracket 02 nos etc and fixed to wall with plastic rowl plug and steel screw complete all as specified and directed. |
| 50 | S & F 600mm x 450mm mirror of thickness 5.0 mm with chromium plated brass spacers 25 to 30 mm in size in each corner including rounding the edges of the mirror and fixed-in-repairs complete all as specified |
| 51 | M & L for prepring old plaster surface by applying 1-2 mm thick wall care putty applying one coat Oil Bound distember on wall surface with roller brush complete all as specified and directed. |
| 52 | M&L for applying subsequent Coat of oil bound distemper complete all as specified and as directed. |
| 53 | M & L for newplaster surface applying two coat Oil Bound distember on wall surface with roller brush complete all as specified and directed. |
| 54 | M & L for prepring old plaster surface applying one coat of oil bound distemper on ceiling surface with roller brush complete all as specified and directed. |
| 55 | M&L preparing newly Plastered surfaces of Walls by applying Wall Putty 1 to 1.5 mm thick , cutting/rubbing to obtained a Smooth Surface and applying Two Coats of Weather Coat Exterior Paint with approved Tint over a coat of Primer (as per Manufacturer\"s i |
| 56 | M&L preparing old Decorated/Treated/roughPlastered surfaces of Wallsby brooming down or steel wire brushing and scraping downand applying one Coat of Weather Coat Exterior Paint (in Camuflage/Plain pattern as ordered) with approved Tint(as per Manufacturer\"s instructions), complete all as specified and as directed. |
| 57 | M&L applying subsequent Coats of Weather Coat Exterior Paint (in Camuflage/Plain pattern as ordered) with approved Tint(as per Manufacturer\"s instructions), complete all as specified and as directed. |
| 58 | M&L for preparing new wooden surfaces of any description, not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over pink primer. |
| 59 | M&L Preparing old painted surfaces of wood of any description, not otherwise described, over 10cm width or girth and one coat of synthetic enamel paint. |
| 60 | M&L for preparing old painted steel and iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying one coat of synthetic enemal paint complete all as specified and directed. |
| 61 | Taking down existing damaged APP membrane and clean the surface , frost, surface laitance and contamination and free from loose aggregate, iclean with water complete all as directed by Engr-in-Charge. |
| 62 | M&L for PCC 1: 2 :4 Type B-1 (using 12.5 mm graded stone aggregate) as in padding over roof slab laid to slope finished even and smooth, roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.(Note : Rates are included upto G+2 Storey) |
| 63 | M&L for 10 mm thick cement plaster with CM 1:4 smooth finish for application of waterproof coating primer the surface clean with water complete with making the corner plain and smooth all as directed by Engr-in-Charge.(Note : Rates are included upto G+2 Storey) |
| 64 | Supply only Integral Water Proofing Compound, ISI Marked, as approved, complete all as specified and as directed. |
| 65 | M&L for cleaning the newly plastered surfaces thoroughly with wire brushes and providing water proofing treatment all as specified here in after :- (a) Bituminous primer @ 0.30liter per sqm conforming to IS 3384-1986(b) 3mm thick APP polymeric membrane minimum weighing 3 Kg/Sqm laid by torch application method with over laps of 100 mm joints of traverse direction and 75 mm at longitudinal direction duly thermofused by flame torch all as specified in application manuel of the company(c) Applying two coat of aluminium paint @ 100ml/Sqm |
| 66 | Supply and fix Godrej pattern mild steel cup board with shutter made out of 1.00 mm thick M.S. sheet60cm depth sides incl with back & 3 shelves & vertical partition & mild steel door shutter two leaves with frame, incl necessary fittings with locking arrangement and handle etc all as per Godrej Pattern with duplicate keys including necessary fittings & two coats of spray painting over a coat of red oxide zinc chromate primer complete and dismantling of old/rusted cupboard frame and shelves. The cost of grouting them in CM (1:3) is deemed to be included in unit rates (Only front face of cupboard to be measured)complete all as specified and as directed . |
| 67 | M&L Steel Work in Tubular Trusses including Special shaped Washer etc. complete using ERW or Induction Butt Welded Tubes, confirming to IS-1161-1979 Grade-240, including dismantling old steel complete all as specified and directed |
| 68 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 69 | M&L Removing Complaint of Blockage (viz Blockage in Bath, Kitchen, WC & Drainage in Traps/Line from Trap to 1st Manhole, Blockage in Sewage Line from 1st Manhole to Septic Tank, Cleaning of Manhole) by deploying Trades Men as per Stipulated Time Frame from 9.00 AM to 5.00 PM (Complaints as per MES Complaint register), complete all as specified and as directed. |
| 70 | M&L Clearning Choked Sewer Lines of 100 mm dia and over upto any depth, Manually or thorough Mechanical Appliances and Making Sewer Line Functional complete including Working Under Foul Condition and depositing the sludge, rubbish, etc. off the Premises outside the MOD/AF Land or Sewage Treatment Plant, complete all as specified and as directed. |
| 71 | M&L Removing Manhole Cover and Desludging/Desilting/Cleaning of existing Manholes of varying depth filled with Sludge by means of Manually or through Mechanical Appliances complete, Working Under Foul Condition and resetting the Manholes Cover in same Position and depositing and removal of Sludge, Rubbish, etc. off the Premises Outside Defence Land, complete all as specified and as directed. |
| 72 | M&L Dewatering Sludge from Soakage Wells/ septic tank by Pumping out as required to keep the Complete Sewage System in order and as to avoid any Over flowing of Sewage Water including removing of Soak Well water pumped out as such out side of Defence Land by means of Pumps and Tankers (Capacity of Water Tanker shall be 5000 Litres) as required including Operating and Supervisory Staff(s) so as to keep the whole Station area Pollution Free, complete all as specified and as directed.NOTE : Each Trip of Tanker to be taken Out side of MOD/AF Land in presence of JE in-Charge.This includes deployment of necessary T&P and nothing shall be Paid Extra. |
| 73 | Cleaning of Sewage pipe line (RCC/SGSW) of Upto 300mm bore by means of sewage cleaning jet machine /Super sucker machine and clean out the sluge /liquid mud or any other obstruction material to any depth including nesesarry rodding, working in foul position and depositing of sludge/silt/liquid mud beyond the premises of MOD land etc complete with all specified pressure rating and complete all as directed by Enge-in-charge.Note :- All other arrangment of electricity, water, etc included in quoted cost.Also the jet machine/super sucker machine to be deployed and work for atleast 8 hours in oneday incl atleast 05 person of labour to carry out neccessary cleaning of manhole/sewer line at the time of deployment of machine in the station. |
| 74 | Taking down PVC (SWR) pipesof any description with fitting and making good to disterbed surfaces. |
| 75 | S&F in repair 110mm bore PVC(SWR) pipes single socketed in any lengthpressure rating 4Kg/Sq cmmedium Grade fixed to walls with clamps or laid to floor or trenches with dash through nut and bolt at every 2mtr length including)includingall fittings complete all as specified and directed by Engineer-in-charge.Notes : The Area includes in this items to working in shaft portion upto 2 storied building. |
| 76 | S&F in repair 110 mm bore PVC(SWR) pipes single socketed Pressure rating @4Kg/Sq cm medium grade in any length with rubber ring joint, fixed to walls or laid in floor or trenches including taking down eaves, gutters rain water pipes (any size or pattern) including all fittings(Tee, elbow etc) complete all as specified and directed by Engineer-in-charge. Notes : The Area includes in this items to working in shaft portion upto 6th storied building. |
| 77 | Taking up or down Steel Tubing 25mm bore (dia) and Connections, segregating the Serviceable Pipes and Connections, stacking properly at Site(s) and keep in Safe Custody for re-use, complete all as specified and as directed.Notes : The Area includes in this items to working in shaft portion upto 6th storied building. |
| 78 | S&F in repair 25 mm bore dia galvanized steel tubes medium grade with all fittings required etc and their making good, complete all as specified and direced. |
| 79 | Excavation in trenches n.exc 1.50 m wide and n.exc 1.50 m in depth for foundation or shafts,wells,cesspits,manholes,pier holes,cable laying,sewage/water lines etc complete and getting outin soft/loose soil complete all as specified and directed. |
| 80 | Demolition and breaking of drain pipes of 150 mm dia (Salt galzed ware, AC or Reinforced concrete set in cement mortar etc complete all asdirected |
| 81 | Demolition and breaking of drain pipes of 100 mm dia (Salt galzed ware, AC or Reinforced concrete set in cement mortar etc complete all asdirected |
| 82 | M&L for double wall corrugated drain pipes of 150 mm dia bore class SN-8, laid and jointed using rubber ring joints complete with collars etc complete all as specified and as directed. |
| 83 | M&L for double wall corrugated drain pipes of 100 mm dia bore class SN-8, laid and jointed using rubber ring joints complete with collars etc complete all as specified and as directed. |
| 84 | Returning filling in including spreading leveling watering and well ramming in layer not exc 25cm thick all as specified and directed |
| 85 | Removal of surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.50 mtr above the starting point complete all as specified. |
| 86 | Demolition of cement concrete (reinforced) in any description and in any postion not otherwise specifically provided for etc complete all as directed |
| 87 | M&L for Pre-Cast reinforced cement concrete 1:2:4 type B-1 with using 20 mm gradedcrushed stone aggregates as in cover slabs (for manholes etc) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plan faces set in cement mortar (1:4) including necessary use and waste form work etc complete all as specified and as directedNote - Reinforcement shall be measured and paid separetly |
| 88 | M&L for TMT bars upto 10mm diaas in reinforcement for concrete, cut to length, bent to shape required including cranking , bending spiraly for hooping for columns, hooking with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and as directed |
| 89 | Demolition of brickwork or stone boulder masonry, built in cement mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 90 | M&L for Cement concrete1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in bed of drain foundation, filling and mass concrete complete all as specified and directed. |
| 91 | M&L for Brick work with sub class \"B\" Old size bricks, straight or curved on plan to any radius in cement mortar (1:4) as in half brick wall and pointed flush in same mortar as work proceeds on one side complete all as specified. |
| 92 | M&L Brick work with sub class ‘B’ bricks(old size brick), straight or curved on plan exc 6 mtr mean radius built in cement mortar (1:4) and external face of brick work pointed flush in the same mortar as the work proceeds, complete all as specified and as directed |
| 93 | M&L Brick work with sub class ‘B’ bricks(old size brick), straight or curved on plan exc 6 mtr mean radius built in cement mortar (1:4) and external face of brick work pointed flush in the same mortar as the work proceeds except bricks, complete all as specified and as directed |
| 94 | M&L for plain cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone agggregate as in surface channel drain and bedding including necessary form work and weathering, slightly rounded or chemfered angles complete all as specified and directed. |
| 95 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds,mitred/stopped ends etc complete all as specified and as directed |
| 96 | M&L for cement concrete 1:2:4 type, B1 (using 20 mm graded crushedstone aggregates) as in copings including necessary use and waste offormwork, weathering, slightly rounded or chamfered angles and throating etc complete all as specified and as directed |
| 97 | Demolition of cement concrete in ground floors and paving not exceeding 15 cm thickness ( below or above ground level) and disposing the rubbish to a distance exceeding 50 Mtr but not exceeding 100 Mtr away to low lying areas complete all as specified and directed. |
| 98 | M&L for 40mm thick PCC 1:2:4 type D-2 (using 40mm graded stone aggregate) in sub base of floor or as in floor complete all as specified and as directed . |
| 99 | M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) in sub base of floor or plinth protection complete all as specified and as directed . |
| 100 | M&L for Rubber Pressed,Pre-Cast concrete interlocking coloured paving block of glass fibre reinforced vibro compacted any shape and size conforming to IS-15658:2006 of 60mm thickness made with M35 grade concrete match with grey cement and pigment etc including 20 mm thick sand cushioning complete all as specified and directed. |
| 101 | M&L for exterior grade coloured, glossy finished, rubber pressed precast chequered cement concrete tiles 30cmx30cmx20-25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigments complete including 20 mm thick sand cushioning all as specified and directed |
| 102 | M&Lfor preparation of old concrete surface as in kerb stone or hard standing and applying Two coat of synthetic enamel paint etc complete all as specified and as directed |
| 103 | M& L preparing old for rough cast plastered surfaces of walls and applying two coat of arcylic weather coat exterior paint with approved tint overa coat of primer (as per manufacturer instructions) ,complete all as per specified and directed |
| 104 | M&L for Framed work such asgate, grills, gratings with angle frames, flat plates etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walk ways; railings; framework of water tanksand similar work conforming to Fe.290.Gde-E-165 including dismantling of old steel works complete all as specified and directed |
| 105 | M&L for Applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cu. m. per sq. m complete all as specified and directed |
| 106 | S&F 30-35 mm thick RCC jali in wall/TRCC columns including dismantling old RCC Jali all as specified and directed |
| 107 | S & F for 8 mm dia or over MS bars as in strainers forchain link fencing including necessasary welding and fixing to angle iron complete all as specified and directed. |
| 108 | Dismantling fencing wire mesh, any type etc complete all as specified and directed |
| 109 | Fixing only chain link fencingincludingline wires, any mesh, size and any type of standards, rails, straining bolts etc. |
| 110 | S & F in repair galvanised 2 strand steel barbed wire 2 mm dia barbed with 2.3 mm dia barbs at 75 to 80 mm spacing and straining, fixed to fencing post tieing at crossing with and including galvanised mild steel wire complete all as directed. |
| 111 | Supply only Chain link MS galvanised fencing , any size or type all as specified and directed |
| 112 | Supply, febrication and fixing of stainless steel 304 grade letters smooth finish as per sample provided (Hindi/ English) on granite wall/Steel sheet made out of 1 mm thick stainless steel sheet (minimun size not less than 40mm thick, 100-150 mm in width and 300-600 mm hight) and 10 mm dia, 75mm long MS studs weld with back side of letters as per site requirement fix on granite wall/Steel sheet making holes by drilling machine and studs fix with epoxy adhesive/nut bolts complete all as directed by Engr-in-Charge. |
| 113 | M&L for type B0 1:2:4 (12.5 mm graded aggregate)Providing precastcement concrete louvres and jallies oftype B0 1:2:4 (12.5 mm graded aggregate),25mm thick set in 1:4 cement mortar including fixing in existing framecomplete all as specified and directed |
| 114 | M&L for 18-20 mm thick Granite (of any type) work (table rubbed and polished)for wall lining (veneering towall) 12mm thickin cementmortar (1:3) and pointing with white cement (1:2)using marble dust with admixture of pigment to match with shade of granite including dismantling of old stone slab/ wall tiles complete all as specified |
| 115 | S&F 150 mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor all as spd and directed |
| 116 | M&L for 1.25 mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required |