| Sl. No. | Item Description |
| 1 | Supply of 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 2 | Supply of 2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 3 | Supply of 4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 4 | Supply of 6.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 5 | Supply of 25 mm iron staples/ saddles/ screws |
| 6 | Supply of 25 mm dia. ISI marked, PVC conduit |
| 7 | Supply of 25 mm PVC bends |
| 8 | Supply of 25 mm PVC couplers |
| 9 | Supply of 75 mm X 75 mm X 50 mm PVC box |
| 10 | Supply of Modular GI box for 3 module |
| 11 | Supply of Modular GI box for 6 module |
| 12 | Supply of Modular GI box for 8 module |
| 13 | Supply of S.P. 5/6 amps, one way modular switch, ISI marked |
| 14 | Supply of S.P. 15/16 amps, one way modular switch, ISI marked |
| 15 | Supply of 3 pin 5/6 amps modular socket outlet, ISI marked |
| 16 | Supply of 6 pin 15/16 amps modular socket outlet, ISI marked |
| 17 | Supply of Modular bell push, ISI marked |
| 18 | Supply of Stepped type Modular Fan regulator (2 module) |
| 19 | Supply of Modular blanking plate |
| 20 | Supply of 6 pin 25 amp modular type socket ISI Marked |
| 21 | Supply of Modular base & cover plate for 3 module |
| 22 | Supply of Modular base & cover plate for 6module |
| 23 | Supply of Modular base & cover plate for 8module |
| 24 | Supply of Call bell/ buzzer, single phase |
| 25 | Supply of PVC Batten/Angle Holder |
| 26 | Supply of 6 amps. to 32 amps. ratings , SP MCB, \"C\" curve, 10 KA breaking capacity |
| 27 | Supply of 6 amps. to 32 amps. ratings , SPN MCB, \"C\" curve, 10 KA breaking capacity |
| 28 | Supply of 6 amps. to 32 amps. ratings , TP MCB, “C” curve,10 KA breaking capacity |
| 29 | Supply of Single pole, Blanking plate |
| 30 | Supply of 63 amps., 4 pole isolator |
| 31 | Supply of 40 amps. rating, 4 pole RCCB, 30mA |
| 32 | Supply of 63 amps. rating, 4 pole RCCB, 30mA |
| 33 | Supply of 20 amps. SPN, industrial type socket outlet, with plug top and metal chained cover in sheet steel enclosure |
| 34 | Supply of Aluminium lugs for 16 sq. mm cable |
| 35 | Supply of Aluminium lugs for 25 sq. mm cable |
| 36 | Supply of Aluminium lugs for 35 sq. mm cable |
| 37 | Supply of Aluminium lugs for 50 sq. mm cable |
| 38 | Supply of Aluminium lugs for 70 sq. mm cable |
| 39 | Supply of Aluminium lugs for 95 sq. mm cable |
| 40 | Supply of Aluminium lugs for 120 sq. mm cable |
| 41 | Supply of Aluminium lugs for 150 sq. mm cable |
| 42 | Supply of Aluminium lugs for 185 sq. mm cable |
| 43 | Supply of Aluminium lugs for 225 sq. mm cable |
| 44 | Supply of Aluminium lugs for 240 sq. mm cable |
| 45 | Supply of Aluminium lugs for 300 sq. mm cable |
| 46 | Supply of 16 mm X 125 mm bolts and nuts with washers |
| 47 | Supply of 16 mm X 150 mm bolts and nuts with washers |
| 48 | Supply of GI saddles 19mm x 0.55mm for 25 mm conduit |
| 49 | Supply of 250 mm X 200 mm H.T. danger notice plate |
| 50 | Supply of 200 mm X 150 mm M.V. danger notice plate |
| 51 | Supply of Coke |
| 52 | Supply of Salt |
| 53 | Supplying of 36W Panellight 2x2 ft.,of following body materialand construction as per IS : 10322 withdriver as per the requirementwith Driver efficiency >85%,Operating voltage AC140-270 Volt,freq50/60hz,Operatingtemprange-15degto40degcentigrade,internalsurge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95,IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flickershould be 115 DELHI SCHEDULE OF RATES (E&M) Volume-II 2025below 5 %), life time (LED,Driver & electrical circuitary), of minimum50000 Burning Hours with, 70% of initial Lumenmaintained tilllife ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K/5700°K /6000°K / 6500°K(As perANSI Bin), SDCM(Standard Deviation Color Matching) <3,Maximumpower consumption should not more than the specified rating and Fixture shall be ofrelevant BIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. completeinallrespecti/cconnectionswith1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥105<120 lm/Watt output . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminiumhousing such that LED junction temperature shall not rise above 90°C). Powdercoateddiecast/Extruded aluminiumBody (Thickness > 1.20 mm) LED Panellight 2x2ft. (System lumen efficacy ≥105 <120 lm/Watt) |
| 54 | Supplying of 18 Watt LED Recessed/surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching)LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt ) |
| 55 | Supplying of 18- 22 watt LED surface mounted Batten light of following body materialand construction as per IS : 10322 withdriver (Replaceable)as per the requirement with Driver efficiency >85% ,Operating voltage AC140-270 Volt,freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20,CRI>80, Flicker free, (flickershould be below 5 %), life time (LED,Driver & electrical circuitary), ofminimum 50000BurningHourswith,70%ofinitial Lumenmaintained tilllife ends, CCT3000°K/ 4000°K / 5700°K/6000°K/6500°K(AsperANSIBin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BISstandard andtrade markcertificate(T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. completeinallrespecti/cconnectionswith1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy≥105 <120lm/Watt output . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement |
| 56 | Supply ofceiling fan with Brush LessDirectCurrent (BLDC)Motor,classofinsulation:B, 3 nos.metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based)for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019fan Supply, earthing etc. complete as req (1200mm, BEE 5 star rating, service value≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)) |
| 57 | Supply of 7W / 9W LED Bulb Make:Havells/Philips/Crompton/Wipro |
| 58 | Supply of 15W LED Bulb Make:Havells/Philips/Crompton/Wipro |
| 59 | Supply ofAC Exhaust Fan 300mm (12”) Sweep (Light Duty) |
| 60 | Supply of 300mm Sweep WALL MOUNTING FAN |
| 61 | Supply of Surface Box [Supply ofSURFACE MOUNTING BOXES (PLASTIC) - HIGHER END]- 3 Module |
| 62 | Supply of Surface Box [Supply ofSURFACE MOUNTING BOXES (PLASTIC) - HIGHER END]- 4 Module |
| 63 | Supply of Surface Box [Supply ofSURFACE MOUNTING BOXES (PLASTIC) - HIGHER END]- 6 Module |
| 64 | Supply of Surface Box [Supply ofSURFACE MOUNTING BOXES (PLASTIC) - HIGHER END]- 8 Module |
| 65 | Supply of Surface Box [Supply ofSURFACE MOUNTING BOXES (PLASTIC) - HIGHER END] 8 (2 row x 4) Module |
| 66 | Supply of 5 Amps 3 Pin Top |
| 67 | Supply of 10 Amps MC Plug with 3 Pin Top |
| 68 | Supply of 20 Amps MC Plug with 3 Pin Top |
| 69 | Supply of PVC /cotton tape Role (8 Mtrs) |
| 70 | Supply of 12 / 15 MS plain rod fan hook |
| 71 | Supply of 19 / 20 mm Steel tube fan down rod |
| 72 | Supply of Concealed box PVC / MS with hook for fan |
| 73 | Supply of Ammeter selector switch |
| 74 | Supply of Voltmeter selector switch |
| 75 | Supply of 400mm High speed pedestal fan Oscilating with High Speed & Air Thrust | Aerodynamic Blades with cutting edge design | 100% Copper Winding Motor | 2 Years Warranty (heavey Duty) |
| 76 | Supply of 6A, flush type Neon Indicator |
| 77 | Supply of 3 Core 2.5 Sqmm with ISI marked Flat Copper cable of ISI for Submersible Motors confirming to IS: 694:1990.Makes:Finolex/RRKabel/Polycab/Havells/KEI/ Gloster/ Goldmedal / GM/ Finecab/ Million/ APAR(Anushakthi) |
| 78 | Supply of 155 X 210 X 92 Sizes thermo-plastic cable junction boxes with IP66/67 weatherproof, for outdoor installation with knockouts for cable entry including terminals etc., complete (sizes in mm).Make : Hensel/Sadhrish |
| 79 | Supplyof 230V/ 275V, 50Hz rating of 2.5/3.15/4.0/6.0 micro farad Running capacitor. |
| 80 | Supply of 25A Modular PVC Box type Wall Socket with C-20A/C-25ASingle Pole MCB protected AC socket with Plug TopMake : Havells/orbit/anchor/MK/Legrand |
| 81 | Supplyof 2 Pin/ 4 Pin LED PL-L-4P Round/squared 9W LED bulb/lamp suitable for existing panel light Make: Havells/Philips/Wipro/Crompton |
| 82 | Supply of 4 Pin LED PL-L-4P Round/squared 18W LED bulb/light suitable for existing panel lights-Make:Havells/Philips/Wipro/Crompton |
| 83 | Supplyof 3W/5W Led Mini Downlighter Recessed Ceiling Lampsuitable as per required.Make: Havells/Philips/Wipro/Crompton |
| 84 | Supplyof Rewirable Fuse (Kit-Kat) with Fuse base & Fuse carrier are made of high grade porcelain These are available from 32A and Rated voltage: 415V, 50Hz Standard: IS 2086:1993 |
| 85 | Supplyof Rewirable Fuse (Kit-Kat) with Fuse base & Fuse carrier are made of high grade porcelain These are available from 63 A and Rated voltage: 415V, 50Hz Standard: IS 2086:1993 |
| 86 | Supplyof Rewirable Fuse (Kit-Kat) with Fuse base & Fuse carrier are made of high grade porcelain These are available from 100A Rated voltage: 415V, 50Hz Standard: IS 2086:1993 |
| 87 | Supply of HRC FUSE LINKS 6 to 35 Amp (DIN/BOLTED TYPE ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2 |
| 88 | Supply of HRC FUSE LINKS 45 to 63 Amps (DIN/BOLTED TYPE ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2 |
| 89 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 90 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm |
| 91 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 35 sq.mm and upto 95 sq.mm |
| 92 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 93 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 94 | LED Streetlight fixture 50 watt, powdercoatedpressurediecastaluminumbody(Systemlumen efficacy >135 lm/Watt) Supplying,installation,Testing&Commissioningof 50 watt StreetlightLEDfixture, powdercoated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage:140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-45, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95,IP66,IK-10,CRI>80,undervoltageandovervoltageprotection,EMIEMCasper CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry)ofminimum 50000BurningHourswith70%ofinitial Lumenmaintained tilllife ends as per LM80 extrapolation IES TM-21-11 report,CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be ofrelevant BIS standard ompleteinallrespecti/cconnectionswith1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy>135lm/Watt output . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminumhousing such that LED junction temperature shall not rise above 90°C). |
| 95 | LED FloodLight 150 watt, powdercoatedpressurediecastaluminium(Systemlumen efficacy ≥120 and <135lm/Watt) Supplyingof 150 watt FloodLight, powdercoatedpressuredie cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%,Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95,IP-66,IK-10,CRI>80,undervoltageandovervoltageprotection,EMI-EMCasper CISPR-15,lenses for beam angle 30 deg-120deg as per the application and the project requirementdeg, suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumenmaintained tilllife ends as per LM80 extrapolation IES TM-21-11 report , 124 DELHI SCHEDULE OF RATES (E&M) Volume-II 2025 CCT 3000°K / 4000°K/ 5700°K/6000°K/6500°K(AsperANSIBin) , SDCM(Standard Deviation Color Matching) <5,Maximumpowerconsumptionshouldnotmore than the specified rating and Fixture shall be ofrelevant BIS standard completeinallrespecti/cconnectionswith1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy≥120 and <135lm/Watt output . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminiumhousing such that LED junction temperature shall not rise above 90°C). |
| 96 | Rewinding of ceiling fan motor (starting and running winding) including all necessary material. The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enameled wire with \"E\" class insulation material and making connections etc. as required. (New model ceiling fan) 900/1200 mm sweep |
| 97 | Providing and Replacement of ball bearing of ceiling/ exhaust fan as required. (NBC/ SKF) |
| 98 | Rewinding of Heavy-duty Exhaust fan motor including all necessary material, The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enameled wire with \"E\" class insulation material and making connections etc. as required.450 mm sweep |
| 99 | Rewinding of 400 mm table fan/pedestal fan motor including all necessary material, the motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enameled wire with \"E\" class insulation material and making connections etc. as required. |
| 100 | Supply and transportation of 16 Sq mm X 4 core coreXLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLES Makes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 101 | Supply and transportation of 25 Sq mm X 4 core XLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 102 | Supply and transportation of 35 Sq mm X 4 core XLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 103 | Supply and transportation of 50 Sq mm X 4 core XLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 104 | Supply and transportation of 70 Sq mm X 4 core XLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 105 | Supply and transportation of 95 Sq mm X 4 core XLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 106 | Supply and transportation of 120 Sq mm X 4 core XLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 107 | Supply and transportation of 240 Sq mm X 4 core XLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 108 | Supply and transportation of 300 Sq mm X 4 core XLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 109 | Supplyof DOL Starter in sheet steel enclosure type MN/ML, AC , 3 Phase, 415 Volts, 50 Hz suitable forUpto 10 HP Motor all as required at site and as directed by the Engr-in-Charge. |
| 110 | Supplyof Fully automatic Star Delta Starter in sheet steel enclosure type MN/ML, AC , 3 Phase, 415 Volts, 50 Hz suitable forUpto 17.5 HP Motor all as required at site and as directed by the Engr-in-Charge. |
| 111 | Supplyof 4.0 KVA 1-phase, automatic Electronic Voltage Stabilizer.Makes:V-Guard / Real Guard / Uni Stab / ITL |
| 112 | Rewinding of 5.0 H.P.- three phase motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original withrequired size of super enameled wire \"E\" class insulation material and testing etc. as required make it in perfect working condition. |
| 113 | Rewinding of 7.5 H.P.- three phase motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original withrequired size of super enameled wire \"E\" class insulation material and testing etc. as required make it in perfect working condition. |
| 114 | Rewinding of 10.0 H.P.- three phase motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original withrequired size of super enameled wire \"E\" class insulation material and testing etc. as required make it in perfect working condition. |
| 115 | Rewinding of 15.0 H.P.- three phase motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original withrequired size of super enameled wire \"E\" class insulation material and testing etc. as required make it in perfect working condition. |
| 116 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A,30KA,FPMCCB |
| 117 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.250 A,36KA,FPMCCB |
| 118 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board includingdrilling holes in cubicle panel, making connections, etc. as required. 400 A, 50KA, FPMCCB |
| 119 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 630 A, 50KA, FPMCCB |
| 120 | Supplyof 230V/ 275V, 50Hz rating of 20-60 micro farad.Starting capacitor |
| 121 | Removing of existing Split Air Conditioners without damaging to copper pipe. |
| 122 | Repairs and Installation of existing PCB in 1.0 / 1.5 /2.0 Ton Split A.C. Unit |
| 123 | Servicing the Split type 1/1.5/2.0 Ton AC Machine by Cleaning through the water jet pump with condenser cooling Coil etc., by blower and oiling the Fan Motor for the indoor and outdoor units and Cleaning all parts and putting the machine in working condition and charging the refrigeranet gas if required basis only at site all as directed by the Engr-in-Charge.(Note :1. If requirement of refrigerent gas is essential basis will be measured and paid under separate item. ie.for methodologyby weighing the gas cylinder before and after charging for how much gas have been charged.2. Otherwise servicing only accounted for this item). |
| 124 | Fabrication, Transportation and supply of 1.0 Mtr Length Single Arm Bracket made with MS galvanized 40mm / 50mm dia Pipe. (The design should be approved from field Engineers)POLE BRACKETS |
| 125 | Supplyof (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required.Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec Analog type (96 mm x 96 mm) |
| 126 | Supplyof (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required.Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec Digital type |
| 127 | Supplyof CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Below 500 A /Above 500AMake: Conzerve/Elmeasure/Meco/HPL/L&T/ socomecAnalog type (96 mm x 96 mm) |
| 128 | Supplyof CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Below 500 A /Above 500A Make: Conzerve/Elmeasure/Meco/HPL/L&T/ socomec: Digital type (96 mm x 96 mm) |
| 129 | Supplyof 240/220 V, LED (22.5 mm dia) Pilot lamp with integral circuit, terminal block, including connection etc. as required : Red/yellow/Green colour |
| 130 | Supplyof 240/220 V, LED (22.5 mm dia) Pilot lamp with integral circuit, terminal block, including connection etc. as required:Blue colour |
| 131 | Supplyof push button actuators and integral contact block of dia. 22.5 mm including making connection etc. as required.Make:Seimens/ ABB/ Schneider/L&T/C&S/HPL : Non-luminous type |
| 132 | Supplyof push button actuators and integral contact block of dia. 22.5 mm including making connection etc. as required. Make:Seimens/ ABB/ Schneider/L&T/C&S/HPL : luminous type |
| 133 | Routine maintenance of transformer, including testing of insulation resistance, oil breakdown strength. Reconditioning / replacement of silica zel,cleaning of transformer and topping upto oil level ifrequired (extra cost will be paid for oil). |
| 134 | Testing of Transformer oil for dielectric breakdown strength. |
| 135 | Supply of new and tested transformer oil as per IS-335 - 1972 (per Ltr) |
| 136 | Filtration of transformer oil as per ISS specifications filters to dielectric strength above 40KV …….at site. (Per Ltr) |
| 137 | Supplyincluding Transportation of 5 HP Three phase open well ISI submersible motor pumpset confirms to IS 14220: 1994. .Makes: Kirloskar / Crompton / Texmo / CRI /KSB/Lubi/ PSG/ ARYEN VARSHA /Falcon/Prithvi |
| 138 | Supplyincluding Transportation of 7.5 HP Three phase open well ISI submersible motor pumpset confirms to IS 14220: 1994. .Makes:Kirloskar / Crompton / Texmo / CRI /KSB/Lubi/ PSG/ ARYEN VARSHA /Falcon/Prithvi |
| 139 | Supplyof stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT |
| 140 | Supply and Transportation of 7.5 HP,5star rated submersible motor pumpset, confirming to IS 8034 and motor confirming to IS 9283 with waterproof winding, Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415V ± 10%, Three Phase 50 Hz AC supply etc complete for6\" Bore well.Makes: Kirloskar / Crompton / Texmo / CRI / KSB/Lubi/ |
| 141 | Supply Installation Testing and commissioning of self-healing MPP/MP type shunt capacitor Heavy duty Three phase 440 V, 50 Hz capacitor (Bank)conforming to IS:13340-41 / IEC :831-1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.5 Watt per KVAR. including making connections with suitable capacity conductors/cables testing as required. |
| 142 | Supplyof 440 Volt 3 pole capacitor (AC 6 B) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current, conforming to IS:13947-4-1/IEC:947-4-1, Din rail mounting type including making connections, testing etc. as required. suitable for 21 to 25 KVAR capacity capacitor bank. |
| 143 | Supplyof 440 Volt 3 pole capacitor (AC 6 B) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current, conforming to IS:13947-4-1/IEC:947-4-1, Din rail mounting type including making connections, testing etc. as required. suitable for 50 KVAR capacity capacitor bank. |
| 144 | Refilling-6 Kg ABC Stored Pressure type Fire Extinguisher IS 2190 Incluing tranportation and Refixing in good condition as directed by Engineer In-charge |
| 145 | Refilling- 4.5Kg CO2type Fire Extinguisher as per IS 2190 Incluing tranportation and Refixing in good condition as directed by Engineer In-charge |
| 146 | Taking down the indoor and outdoor units by pumpdown the refrigerent gas & Overhauling and servicing the Split type 1/1.5/2.0 Ton AC Machine by Cleaning through the water jet pump with condenser cooling Coil etc., by blower and oiling the Fan Motor for the indoor and outdoor units and Cleaning all parts and putting the machine in working condition for the indoor and outdoor units if required at site all as directed by the Engr-in-Charge(Note: The rate deems to be inclusive of replacement of filter, charging of refrigerent gas, Starting/running capacitors, Electrical wiring intacts, condensing water line intacts & performance test andif any minor parts required at site) |
| 147 | Supply and filling of R-22 / R-32 Refrigerant Gas for AC Units |
| 148 | Supplyof 12V 180 AH SMF battery with 3 years warranty, including wire leads, connections etc complete on Buy back basis. Makes: Quanta / Racket / Exide. |
| 149 | Supplyof 12V 18 AH SMF battery with 3 years warranty, including wire leads, connections etc complete. Makes: Quanta / Racket / Exide. |
| 150 | Supplyof 12V 9 AH SMF battery with 3 years warranty, including wire leads, connections etc complete. Makes: Quanta / Racket / Exide. |
| 151 | General servicing & preventive maintenance of 100 HP electric pump motor including IR test, terminal check, lubrication, alignment verification, cleaning, and test runby authorized technician etc.. In the presence |
| 152 | General servicing & preventive maintenance of 25 HP electric pump motor including IR test, terminal check, lubrication, alignment verification, cleaning, and test run. |
| 153 | General servicing & preventive maintenance of diesel engine-driven fire pump (DG set type), including inspection and servicing of the fuel system (tank, lines, sedimenter), battery terminals & charger, cleaning of air/oil/fuel filters, lubrication check, radiator cleaning, and full test run of pumpto be done by OEM authorized agency or experienced diesel mechanic . Excludes cost of consumables like filters, oil, and spares. |
| 154 | General servicing & preventive maintenance of 630A, 11 kV VCB, including internal cleaning, lubrication, inspection of vacuum interrupters, tightening of terminations, interlock & mechanism check, insulation resistance test, manual/electrical operation testing of Relay,CT, PT,Breaker Electrical Testing and submission of report. Work to be carried out with approved tools and as per IS/CEA safety norms. |
| 155 | Supply and Fix pressure switch in MS pipe line including all connections with siphon all as directed by the Engr-in-Charge. |
| 156 | Sipply &Fixing of high performance Butterfly Valve of size 200 mm carbon steel body with stainless steel spindle including necessary SS bolts & Nuts, flanges, cutting and welding all as required at site including taking down the u/s one and as directed by Engr-in-Charge. |
| 157 | Sipply &Fixing of high performance Butterfly Valve of size 150 mm carbon steel body with stainless steel spindle including necessary SS bolts & Nuts, flanges, cutting and welding all as required at site including taking down the u/s one and as directed by Engr-in-Charge. |
| 158 | Sipply &Fixing of high performance Butterfly Valve of size 100 mm carbon steel body with stainless steel spindle including necessary SS bolts & Nuts, flanges, cutting and welding all as required at site including taking down the u/s one and as directed by Engr-in-Charge. |
| 159 | Sipply &Fixing of high performance Butterfly Valve of size 80 mm carbon steel body with stainless steel spindle including necessary SS bolts & Nuts, flanges, cutting and welding all as required at site including taking down the u/s one and as directed by Engr-in-Charge. |
| 160 | Sipply &Fixing of Steel wire mesh strainer suitable for 200 mm \"Y\" type strainer. |
| 161 | Sipply &FixingPressure Gauge0-10 Kg/Cm2 with swiphon including taking down the old one as directed by Engr-in-Charge. |
| 162 | Servicing and cleaning of existing Smoke detector and fire alarm system to made fully functional the visual indication, monitoring system including connections, interconnections and made functional for the locking arrangements with key including proper checking for loop connections and fixing new batteries as required at site etc all as directed by the Engr-in-Charge. Note:- Batteries will be measured and paid under separate items. |
| 163 | Servicing of CI Sluice valve of size 200 including necessary rubber gasket all as directed by the Engr-in-Charge. |
| 164 | Servicing of CI Sluice valve of size 150 all as directed by the Engr-in-Charge. |
| 165 | Supplyof Shunt Release (SR) [8538] coil for existing L & T ACBs |
| 166 | Supplyof Under Voltage Release (UVR) [8538] coil for existing L & T ACBs |
| 167 | Quarterly preventive maintenance of 5000 LPH RO Plant including inspection and servicing of high-pressure pump/motor, cleaning of dosing pumps, NRVs, and pipelines, backwashing of multimedia and activated carbon filters, checking of control panel and safety interlocks, testing of water quality, replacement of pre-filters (sediment, carbon, and PP cartridges), replenishment of antiscalant (~5 L) and membrane cleaning chemical (~1 kg citric acid), supply of service consumables, deployment of one service engineer, one technician and one helper for one full day, and inclusive of local conveyance/ travel as applicable, complete in all respects (excluding major spares like membranes, pumps, motors or rewinding, which shall be charged separately). |
| 168 | Painting ofstreet light pole (MS tubular/swaged type) including thorough surface cleaning with wire brush/emery paper to remove rust, dust & loose paint, application of one coat approved anticorrosive metal primer and two coats of approved synthetic enamel paint of specified shade, including thinning, provision of brushes/consumables, and all lead, scaffolding/ladder work, complete as directed by Engineer-in-Charge. |
| 169 | Carrying out minor welding works on existing street light poles/pipes/structure including surface preparation by cutting/grinding, welding with suitable electrodes (E6013 or equivalent) using portable welding set, rectification of cracks, base plate, brackets/fittings as required, finishing the welded portion with grinding, application of primer, and one coat of synthetic enamel paint of approved shade, complete as directed by the Engineer-in-Charge. |
| 170 | Testing of earth pit including measurement of earth resistance using digital 3/4-wire earth resistance tester (fall-of-potential method or clamp/three-wire as applicable), providing site test certificate, signed by authorized technician, and submission of soft/hard copy report, complete as directed by Engineer-in-Charge. |
| 171 | Servicing and repair of 7.5 HP submersible motor including site inspection, hoisting/lowering, dismantling, supply and replacement of bearings, complete rewinding with super enamelled copper wire (approx. 12 kg, Class F insulation) with varnishing and baking, reassembly, alignment, insulation resistance test, load test and commissioning at site, including labour, transport and handling charges complete as directed by Engineer In-charge. (6 month warranty for Re-winding) |
| 172 | Servicing and repair of 7.5 HP submersible pump including dismantling, cleaning, lubrication, supply and replacement of mechanical seals, impellers or diffusers as required, major overhauling with shaft alignment and balancing, reassembly, testing for flow/pressure and commissioning at site, including labour, hoisting/lowering, transport and handling charges complete as directed. |
| 173 | Supply, installation, testing and commissioning of Single Phase Preventer suitable for 3-phase starter panel, designed to protect motor against single phasing, phase reversal and phase unbalance. The device shall operate on 415 V, 50 Hz, automatically disconnecting the motor starter under fault condition and allowing restart only under healthy phase sequence. The unit shall be panel-mounting type with LED indication, suitable for continuous duty, complete with necessary wiring, connections, fixing arrangements, accessories and as directed by engineer In-charge.Make : Minilec / L&T / Siemens / ABB. |
| 174 | Dismantling of existing 100 HP, 415 V, 3-phase squirrel-cage induction motor of fire pump set, removal of worn-out bearings, supply and replacement of new heavy-duty antifriction bearings of suitable size , cleaning of housing and shaft, proper mounting of new bearings using press fitting, greasing with recommended grade lubricant, re-assembly of motor, alignment with pump, testing and commissioning for satisfactory operation, including labour, tools, tackles, consumables, and transportation if required, complete as directed by engineer In-charge. SKF / NTN / Timken / FAG or equivalent ISI-marked |
| 175 | Dismantling of existing 25 HP, 415 V, 3-phase squirrel-cage induction motor of fire-pump set, removal of worn-out bearings, supply and replacement of new heavy-duty antifriction bearings of suitable size (SKF/NTN/Timken/FAG or equivalent approved make), cleaning of housing and shaft, proper mounting of new bearings using press-fit method, greasing with recommended lubricant, re-assembly of motor, alignment with pump, testing and commissioning for satisfactory operation, including labour, tools, tackles, consumables, and transport if required, complete as directedby engineer In-charge.SKF / NTN / Timken / FAG or equivalent ISI-marked. |
| 176 | Supply and fixing of premium RO membrane elements, size 8040, Thin Film Composite (TFC), suitable for brackish water / industrial RO plant of 5000 LPH capacity, make: Filmtec / Dow / Hydranautics / equivalent approved, with minimum 99% salt rejection and rated flow of ~10,000–11,000 GPD per element, complete with manufacturer’s test certificate and warranty. |
| 177 | Credit for dismantled materials old battery upto 18 Ah |
| 178 | Credit for dismantled materials Ceiling Fan (Old, complete set) |
| 179 | Credit for dismantled materials Wall Mount Fan (Old) |
| 180 | Credit for dismantled materialsExhaust Fan (Old) |
| 181 | Credit for dismantled materialsStreet Light Fitting (LED/HPSV – Old) |
| 182 | Credit for dismantled materialsLED Tube Light / Panel Light (Non-working) |
| 183 | Credit for dismantled materials LED Bulb (Non-working) |
| 184 | Credit for dismantled materials CFL Fitting – 2 Pin / 4 Pin (Old) |
| 185 | Credit for dismantled materials Fluorescent Tube Fitting (Old) |
| 186 | Credit for dismantled materials Fan Capacitor (Old) |
| 187 | Credit for dismantled materials Miniature Circuit Breaker (MCB – Old) |
| 188 | Credit for dismantled materials Distribution Board (MCB Box – Old) |
| 189 | Credit for dismantled materials Electrical Switches (Various) |
| 190 | Credit for dismantled materials 5A / 15A Sockets (Old) |
| 191 | Credit for dismantled materials Call Bell / Buzzer |
| 192 | Credit for dismantled materials Old Copper Wiring (Mixed Gauge, Insulated) |
| 193 | Credit for dismantled materials Aluminium Wiring (Scrap) |
| 194 | Credit for dismantled materials PVC Conduits / Flexible Pipes (Scrap) |
| 195 | Credit for dismantled materials Armoured UG Cable (Aluminium Core) – Scrapped |
| 196 | Engaging of 1 No \"C\" Licence Holder (Supervisor)of day to day maintenance of Electricalmaintenance works and to monitor these works are properly attended and to take care of complaints arised related to repairs / replacement of damaged fittings / fixtures in the campus such as switches, sockets, switch boards, HT/LT Panels , MCBs, MCB DBs, MCCBs, SFUs, FSUs etc., andall types of fans / light fittings,UG cables etc., complete all as directed by the Engineer-in-charge. ( 01 No.) (Qualification: Diploma in Electrical Engineering with 10 years related experience/ITI with 12 years or experience (supervisory) in maintenance job)(Qualification: ITI certificate with 03 years experience in operation of 11KV / 415V Substation and equipment and DG Sets along with valid 11KV /415V Supervisor permit /C- certificate/grade C-License Holder) (Higly Skilled).He is resposonsible to maintain & update the all logbook of preventive maintenace E&M equipment(Lifts,panels,Substation,DG sets,Fire equipment,RO,STP&ETP etc...) with respective staff.[1 No \"C\" Licence Holder ( Highly Skilled)]. Note:-1.He is the responsible for maintain the day to day complaint Register, Preperation of Duty Roster, Material Consumption Register, Log Book/Log sheets and to up keep the neat & Tidy of installations with installed plants & machinaries as per the direction of Engineer-in-Charge 2.He is the responsible for HT Metering cubicle to monitor & maintain all parameter readings.3.He is the responsible for timely calibration of HT VCB\"s, LT ACB\"s/MCCBs and Earth Fault Relays and Over Current Relays.4.He is the responsible for HT Panels, Transformers, ACBs, MCCBs,APFC Panels with connected Capacitor Banks,Power Contactors & Relays, Up Keep & maintain records for earth results in the HT & LT installations as per the direction of Engr-in-Charge.5.During Main EB supply failure to monitor the running of stand by DG Sets and maintain the Plant Running Record Book with all parameters.6.To maintain the EB Shutdown Register & obtain the necessary signature from EB authorities . (It should be talley with Stand By DG Set PRRB) |
| 197 | Engaging an Substaion attendant Cum DG Operator cum Panel opearator for day to day operation of Substation, DG sets, LT Panels , MCBs, MCB DBs, MCCBs, SFUs FSUs etc andall types of fans/ light fittings,UG cables etc complete all as directed by the Engineer-in-charge.andalso Preventive maintenance of above mentioned equipment as per standerd check list and maintain logbooks along with shift register to be updated daily etc to be maintained as directed by engineer-incharge.. Skilled (ITI Certificate with 3 Years Experience)- 4 NosNote: 1.During Gen Shift, DG Opr cum Panel Board Operator can do the Electrical day to day complaints/maintenance work as per the direction of Engr-in-Charge. |
| 198 | Engaging an Lift operator for day to day ( 4 Nos)Lift Operator is responsible for the safe operation of elevators and lifts. Here are some common duties and tasks associated with this role:Loading and Unloading: Lift Operators assist passengers in safely loading and unloading ski lifts or other types of elevators.Safety and Comfort: They ensure the safety and comfort of passengers during lift operations.Maintenance: Operators maintain the lift area, keeping it clean and organized. They also implement emergency procedures when necessary.Evacuation: In case of disabled lifts or emergencies, Lift Operators evacuate passengers as per established protocols.[Supervision: Some operators supervise the lift operations ] (Semi-Skilled-4 nos) ITI with 1Year experience Operation & maintain of Lifts. |
| 199 | RO Operator-1No:RO Plants operator for day to day RO PlantOperator is responsible for the safe operation of Plants. Operate and monitor RO Plants equipment and machinery.Operate and monitor water treatment equipment and processes to ensure the delivery of clean and safe drinking water ,Document operational data and report any rregularities.Troubleshoot and resolve operational issues promptly.Ensure safe work practices and compliance with safety regulations.Coordinate with maintenance personnel for repairs and upgrades etc..as directed by Engineer In-Charge. ( Semi-Skilled-1 NO) ITI with 1Year experience Operation of RO plant & Maintenance. |
| 200 | Engaging a Fire FightingTechnician for day to day maintenance and operation of Fire pump houseby operating of Diesel Engine,Jockey pump,Boosterpump, presurization pump, terrace pump, diesel pumpmaintenance of fire panels and other equipments pertains to fire fighting system etcto maintain required water pressure atall times in External and internal fire hydrants, Hose reelsetc complete all as directed by Engineer in charge. ( 3 No - Fire fighting technician- skilled) (ITI Certificate with 3 Years Experience in Fire Safety). |
| 201 | Engaging an Electrician for day to day maintenance of Electricalworks like repairs to internal and external electricsupplyby replacing the worne out fittings/fixtures , reparing the unserviceable fittings/ fixtures such as switches, sockets, switch boards, LT Panels , MCBs, MCB DBs, MCCBs, SFUs FSUs etc andall types of fans/ light fittings, OH lines, UG cables, DG Setetc complete all as directed by the Engineer-in-charge. (2 nos Electrician- Skilled)(ITI Certificate with 3 Years Experience). |
| 202 | Helper toElectrician for day to day maintenance of Electricalworks like repairs to internal and external electricsupplyby replacing the worne out fittings/fixtures , reparing the unserviceable fittings/ fixtures such as switches, sockets, switch boards, LT Panels , MCBs, MCB DBs, MCCBs, SFUs FSUs etc andall types of fans/ light fittings, OH lines, UG cables etc ...complete all as directed by the Engineer-in-charge. ( 2 nos Un Skilled) |
| 203 | Engaging a Helper to assist technical staff such as HT/LT Panel Operators, Fire Pump Technicians, RO Plant Operators, and Electrical Pump Operators in routine operations and preventive/corrective maintenance activities likeAssisting in electrical fault isolation and repair, Supporting maintenance of LT/HT panels, control wiring, MCCs, etc.Handling tools, material shifting, and cleaning of electrical panels,Support during routine RO plant checks and backwashingbincluding water supply and Coordinating during shutdowns, emergency operations, and safety drills complete all as directed by the Engineer-in-charge. ( 2 nos Un Skilled) |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail