Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Replacing of the following wornout fittings by providing and fixing of heavy quality CP brass fittings of make |
| 2 | 15mm CP brass long body Bib cock |
| 3 | 15mm CP brass Two way Bib cock |
| 4 | Providing and fixing 100mm dia Shower rose with arm \"ESSCO / PLATO\" or approved equivalent type and make all as per specifications and as directed by the Engineer-in-charge. (Sample to be got approved by the Engineer-in-charge) |
| 5 | Providing and fixing 15mm C.P. Brass Urinal spreader size with 1/2\" BSP thread and shapes, weighing not less than 60 gms of \"PLATO\" or approved make and type. |
| 6 | Replacing the wornout/damaged PVC connection by providing and fixing of 15mm x 450mm long PVC connection of make \"Prayag\"/equavalent confirming to IS specification both Cold and Hot water including PVC checknuts and nylon washers on both ends, fixing with GI Specials if required, returning the retrived wornout fittings tocivil section all complete as per specification and as directed by Engineer. |
| 7 | Replacing spares for CP brass fittings such as bib tap, stop cock, pillar cock, push cock, Concealed stop cock , etc., by supplying and fixing the following spares including removing the fittings without interrupting the water supply, servicing the fittings by replacing the wornout spares with new spares, refixing the same and returning the retrived spindles toCivil section all complete as directed by the Engineer-in-charge. |
| 8 | 15mm brass spindle suitable for \"Metro\" / \" Prayag\" Waterman\"/\"Peaco\" Parryware /equavalent etc |
| 9 | 20mm brass spindle suitable for \"Metro\" make/equavalent etc |
| 10 | Replacing the existing damaged IWC pan/Orissa pan by providing and fixing in position of approved make white glazed vitreous china ware ORISSAPAN WATER CLOSET of PARRYWARE or equivalent make with \"S\" or \"P\" trap with all jointing materials including removing the damaged IWC/Orissapan, chipping out the floor, concrete, brick wall, brick bat etc., making holes in masonry, fixing the new Orissapan, jointing the pipe & Trap with Lip ring of \"PRINCE\" or approved make, reconstructing the same, encasing the pan and trap with brick jelly concrete 1:2:4 and back filling extra space with river sand/brick jelly concrete, including disposal of debris within 2kms lead, cost of cement required for the work etc., all as per specifications and as directed by the Engineer-in-charge. (Note: Cost of floor finishing such as mosaic/IPS floor etc., will be paid extra under relevant item). |
| 11 | 580x440mm size ORISSAPAN |
| 12 | 500x400mm size ORISSAPAN |
| 13 | Replacing the wornout/damaged Health faucet supporting hooks by supplying and fixing wall hook of make \"Prayag (Drizzle)\" or approved make including removing the damaged wall hook, fixing the new hooks, finishing the surface, etc., all complete as per specification and as directed by the Engineer- In-Charge. |
| 14 | Replacing the wornout Elbow action tap by providing and fixing of heavy quality 15mm CP brass pillar cock with extended lever handles of make \"Jaquar (Medi series)\" or any other approved equivalent make including require GI special and returning the retrived wornout fittings to FRFCF Civil section all complete as per specification and as directed by the Engineer-in-charge. |
| 15 | Labour charges for removal of water choke inwash basin by removingthe waste coupling accessaries and removing the choke including refixing with required GI specials, connecting to the inlet and outlet connection by using the existing accessories without damaging the wash basing etc., all complete as directed by the Engineer-in-charge. |
| 16 | Labour charges for refixing the existing high / Low level flushing cistern along with telescopic pipe by removing the existing cistern with telescopic pipe and refixing the flushing cistern with necessary PVC brackets and support at required height including connecting the cistern and closet with suitable 40mm dia. PVC pipe with necessary specials, modifying the GI line if necessary, dismantling floor for removing the damaged telescopic pipe and restoring the same to its original condition etc., all complete as directed by the Engineer-in-charge. (Excluding cost of PVC pipe and GI pipe if required which will be paid separately under relevant item)Note: During the above process proper care shall be taken to protect the existing IWC/EWC if any damage is taken place in IWC/EWC contractor shall replace with new IWC/EWC free of cost. |
| 17 | Labour charges for refixing the following sizes of existing GI pipe line which have come out from its original position due to decay of teak wood plug/packing piece, rusted GI clamps including threading the existing GI pipe if necessary and fixing with new specials if required, providing new Teak wood plug/packing piece, fixing with new GI clamp with necessary screws, painting a coat of synthetic enamel paint etc., all complete as directed by the Engineer-in- charge. |
| 18 | 15mm and 20mm dia. GI pipe |
| 19 | 25mm and 40mm dia. GI pipe |
| 20 | Labour charges for rectifying the leakages in water supply pipe line of various sizes by removing the damaged portion of GI pipe and replacing with new GI pipes upto 500mm long including cost of medium class GI pipes of make \"Tata\" bearing ISI mark and GI specials such as Coupling, Nipple, Tee, bend, elbow, reducer, union, etc., cutting, threading and jointing with white lead, painting two coats of synthetic enamel paint over a coat of red oxide primer, making necessary opening/chasing of the wall, flooring, etc., fixing with GI clamps over Teakwook plugs, Teakwood packing pieces and screws wherever required and restoring same to its original condition, including cost of the cement required for the work etc. complete all as directed by the Engineer-in-charge. |
| 21 | Upto 25mm dia. GI pipe |
| 22 | Upto 40mm dia. GI pipe |
| 23 | Labour charges for removing the water line choke in GI pipe line by cutting, removing the choke from GI line and restoring the same including cutting, threading, jointing the existing pipe to its original condition, cost of specials required if any etc., all complete as directed all complete as directed by the Engineer-in-charge |
| 24 | Labour charges forremoving the water line choke / cleaning of chinaware European type water closet with \"P\" or \"S\" trap with or without vent including removing the existing EWC pan from its position and refixing the same with necessary plugs, screws and packing the joints with cement mortar 1:1, and connecting the flush pipe, seat cover etc., completed all as directed by the Engineer-in-charge. |
| 25 | Providing and fixing white / coloured solid plastic seat (Hindware / Parryware make or approved make suitable to existing EWC) with lid including CP Brass / SS bolts, screws etc. for pedestal type W.C. pan complete as per specifications and as directed by the Engineer-in-charge. |
| 26 | Labour charge for maintanance of wall urinals / sensor urinals including cleaning, removing chockes and cleaning the drainage pipe line at regular intervel without any interruption for usage, replacing the washer, nuts etc,. completed all as directed by the Engineer-in-charge. |
| 27 | Repairing the flushing cistern of \\Parryware -Slimline\\ or approved equivalent make by supplying and fixing the following spares to flushing cistern including removing the existing flushing cistern, replacing the worn out spares with new spares and refixing the same in original position with working condition etc., all complete as directed by the Engineer-in-charge |
| 28 | 15mm dia. PVC ball cock with suitable PVC float (Inlet Assembly) |
| 29 | 32mm dia. PVC syphon (Outlet Assembly) |
| 30 | 50mm dia. Sypon washer change |
| 31 | Flush bend for EWC |
| 32 | Ring Bush for EWC |
| 33 | Repairing the existing damaged ceramic tiles dadooing by chipping out / dismantling the damaged portion and providing new ceramic tiles by thoroughly removing the damaged tiles, plastering and hacking the plastered surfaces and laying ceramic tiles by using Premium quality (I Class) of SOMANY/ KAJARIA /JOHNSON or other approved equivalent make, size and colour confirming to relevant IS code for dadooing/ anti-skid flooring laid over bed of 12 mm thick in CM 1:3 for dadoo and 20mm thick in cm 1:4 for flooring, pointing the joints with white cement and matching colouring pigments including disposing the dismantled debris at suitable places shown at site within 2Km lead, etc., all complete as per specification and as directed by the Engineer-in-charge. |
| 34 | Attendingday to day complaints on minor repair inAluminium Door window, wooden Door windows, Steel Door door/windows/ cupboards/ various typesby servicing the fittings hinges, tower bolt, handle etc., excluding door closer & lockand replacing the worn out fittings if any re-fixing same and also other carpentry/plumbing related complaints if anyetc. complete all as perdirection of Engineer - in charge. (Note:-The workshall necessitate oneFitter (o )Carpenter (or) Plumberexecuting the works from 9.00 AM to 17.30 PM.) |
| 35 | Attending different type of door lock complient on cal on basis and when required by engageing qualified carpenter with helper including restoring the same / rectifying to all complete as per specification and as directed by the Engineer-in-charge. |
| 36 | Re -fixing of existing wash basin by removing the existing wash basin including removing the CI brackets, old decayed teakwood plugs, fixing new teakwood plugs to wall at required height, re-fixing with new MS brackets with necessary new screws after painting with two coats of synthetic enamel paint, refixing the wash basin and connecting to the inlet and outlet connection by using the existing accessories, providingGI specials if required etc., all complete as directed by the Engineer-in-charge. |
| 37 | Providing and fixing Viterious china white wash basin size 630x450mm (HINDWARE / PARRYWARE) with C.I. brackets, 15mm C.P. brass pillar taps of Jaquar / Parryware or approved equivalent make, 15mm x 600mm long PVC inlet connections, 15mm stop cock, 32mm Heavy quality C.P. brass waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls and testing complete all as per specifications and as directed by the Engineer-in-charge. |
| 38 | Providing and laying Indian Patent Stone Flooring with cement concrete 1:2:4; 20mm thick using 10mm and below size hard broken stones including dismantling the damaged portion of existing floor/dadoo, preparation ofsurface, consolidating, curing, rubbing the surfaces smooth, providing dividing strips, disposing the dismantled debris at suitable places as shown at site within 2Km lead, etc., all complete as per specification and as directed by the Engineer-in-charge. |
| 39 | Providing and fixing Cast Iron Nahani Trap / Floor Trap of 100mm inlet and 75mm outlet, (weighing 5.80 kgs each), jointing with Lead with the connection pipes, placing as per the drawings, including embedding in cement concrete 1:2:4 and making circular hole up to floor level using 110mm O/D PVC pipes of 6 kgs/sq.cm pressure and fixing 1 No 125mm dia C.P. Brass Grating, complete all as specifications and drawings and as directed by the Engineer-incharge. |
| 40 | Providing and laying plain cement concrete M20 grade using 300 kg/cum of PPC, 20mm maximum size graded aggregates and washed crushed stone sand including mechanical mixing, transporting and placing in required position, ramming, compaction, levelling, curing, shuttering, dewatering if any, complete all as per specification up to a height of0 to 17m for levelling courses inscreed concrete at terrace level, encasing pipes and other required works directed by Engineer-in-Charge complete all as per specifications. Dosage of PCE based admixture as per workability requirment at site conditions. Note: 1. The rate of concrete shall include all labour, equipment, charges for mixing & cost of admixture. Polycarboxylate ether (PCE) based chemical admixture confirming to IS 9103 shall be mixed in fresh concrete and prior permission from engineer-in-charge shall be obtained for dosage and compatibility2. Test certificate of cement, procured from dealer/company to be submitted for all cement related works by the Contractor.3. The rate shall be quoted on the basis of using minimum cement per cu.m. of concrete mentioned below for relevant grade of concrete. Any upward/ downward variation required to obtain the specified strength will be paid for or deducted at the rate of cement specified in Schedule F. |
| 41 | Supplying, fabricating, erecting and fixing in position at all levels, centering and shuttering to correct line and levels for transom & mullions including strutting, propping, etc., with necessary bracings in all axes to give a stable assembly with provision for making the joints in the shuttering fully leak proof and with provision for fixing coil nuts with tie rods along with suitable channel for lateral supports and for inserts, projecting dowels, anchor bolts or any other fixture, including staging, access and working platforms etc., all complete as specified and directed including dismantling and removing the aforesaid assembly after the concrete attains the sufficient strength to self-support itself without cracking and distortion all as per specification, including all materials and labour complete in all respects at all lifts. The measurement for the formwork will be the actual area of forms in contact with concrete surfaces. Shuttering with plywood panels alone will be permitted. |
| 42 | Providing and fixing 150mmdia, Cast Iron slotted gratings over the rain water down take pipes at roof level including chipping and grouting, painting two coats of anticorrosive paint complete all as directed by the Engineer-in-charge.Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 43 | Providing and fixing 5 inch dia SS slotted gratings Stainless steel Bathroom Floor Water Drain Grating complete all as directed by the Engineer-in-charge.Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 44 | Providing and fixing anodized aluminium (Anodised transparent or dyed to required shade according to IS: 1868 Minimum Anodic coating of grade AC 15) work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / Z Sections and other sections of approved make confirming to IS: 733 and IS: 1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P brass / stainless screws all complete as per architectural drawings and directions of Engineer-in-charge including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required. (fittings, Glazing and panelling shall be paid for under relevant item)Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF.NOTE: 1) The rates for aluminium is inclusive of all fasteners required for fabrication and fixing in the walls. 2) All joints shall be of mittered joints. 3) A long M.S rod threaded at both ends to be provided in all aluminium door shutters in Top & bottom Horizontal members internally connecting Vertical members and fixed with M.S washers & nuts. 4) Only Aluminium members alone shall be measured and paid for.Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 45 | Providing and fixing glazing with 5mm thick clear Float glass pane in aluminium doors, windows, ventilator shutters and partitions etc. with Neoprene gasket including cost of neoprene gasket complete as per the drawings and directions of the Engineer-in-charge. Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 46 | Providing and fixing glazing with 6mm thick clear Float glass pane in aluminium doors, windows, ventilator shutters and partitions etc. with Neoprene gasket including cost of neoprene gasket complete as per the drawings and directions of the Engineer-in-charge. |
| 47 | Providing and fixing Locks for Aluminium sliding window shutters with :GEETAVIN\" make as per cat. No. SS-004 (Over all size of 204mm x 23mm) or approved Equivalent Quality, make, type all as per specifications. Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 48 | Providing and fixing Single point Lock cum handle for Aluminium openable windows / Top Hung shutter as per cat No. SPL002 Right of GEETAVIN make or approved equivalent Quality and make complete all as per specifications.Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 49 | Providing and fixing IS: 12817 marked stainless steel butt hinges of size 75 x 50 x 2.5mm (heavy weight) \"GARG\" or equivalent approved make with suitable stainless steel screws etc. complete all as per specifications and as directed by the Engineer-in-charge. Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 50 | Providing and fixing Anodised Aluminium handles 125mm with 175 x 32mm including fitting with plate 175 x 32mm including fitting with necessary screws complete all as per specification and as directed by the Engineer-in-charge. Sample to be approved by the Engineer-in-charge.Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 51 | Providing and fixing Anodised Aluminium handles 100mm with 150 x 32mm including fitting with plate 175 x 32mm including fitting with necessary screws complete all as per specification and as directed by the Engineer-in-charge. Sample to be approved by the Engineer-in-charge. Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 52 | Providing and fixing AI hanging Heavy Quality floor door stopper ISI marked with Twin Rubber stoppers, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to req. colour or shade with necessary screws etc. complete all as per specification and as directed by the Engineer-in-charge. Sample to be approved by the Engineer-in-charge. Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 53 | Providing and fixing Swing type heavy quality top PIVOT for suspending aluminium door shutters of single or double leaf all as directed by the Engineer-in-charge. Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 54 | Providing and fixing double action floor spring of \"Hardwin\" or approved brand and manufacturer (confirming to IS: 6315) for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece of M.S. Sheet outer box with slide plate etc. complete as per directions of Engineer-in-charge with brass cover plate. Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 55 | Providing and fixing IS: 3564 marked AI die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. in wooden doors / steel doors with necessary bolts & nuts \"Everite Hardwyn\" or approved equivalent make complete as per specification and as directed by the Engineer-in-charge.Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 56 | Providing and fixing 4 Lever Dead /Mortice Lock \"Godrej/Everite\" or other approved equivalent make suitable for aluminium door with a pair of keys complete all as per specification and drawings.Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 57 | Providing and fixing 6 Lever Dead /Mortice Lock \"Godrej/Everite\" or other approved equivalent make suitable for flush door with a pair of keys complete all as per specification and drawings. |
| 58 | Providing and fixing Stainless steel \"C\" type Door handles 10mm dia SS 304 Grade solid Rod, 250mm long in Steel Doors / wooden Doors including SS screws / bolts etc. all as per drawings and specifications complete. Sample to be approved by the Engineer-in-charge.Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 59 | Providing and fixing Stainless Steel tower bolts of size 300 x 12mm \"GARG\" or equivalent approved make with necessary screws etc. all as per specifications and as directed by the Engineer-in-charge.Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 60 | Replacement ofIS: 12817 marked stainless steel butt hinges of size 125 x 64 x 2.5mm (heavy weight) \"GARG\" or equivalent approved make with suitable stainless steel screws etc. complete all as per specifications and as directed by the Engineer-in-charge.Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 61 | Providing and fixing 30mm thick factory made PVC door shutters with door frames of approved colour/shade \"Sintex / Akrosha\" or approved equivalent make and wall thickness 2mm + 0.2mm with inbuilt edging on both sides. The styles and rails mitred and joined at the corners, including all accessories & fittings like 3 nos. 100mm SS hinges, 2 Nos 125mm Grip aluminium Bow handles, 2 Nos of Aluminium 75m Baby latch for each door complete all as directed at by Engineer-in-charge.Note; Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 62 | Providing and fixing 150 x 200mm vision panelin door shutter using 4mm thick glass with teakwood lipping of 20x10mm size alround complete all as directed by the Engineer-in-charge.note. Including cost of removing the existing material if required. |
| 63 | Providing and fixing ISI marked 35mm thick non-decorative type flush door shutters (single or double leaf and size as per requirement) conforming to IS: 2202, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering, phenol formaldlehyde synthetic resin bonded, hot pressed with internal Teak wood lipping of 25mm depth on all sides and fixing with 4 Nos. 150mm stainless steel Hinges with suitable S.S. screws (8 Nos. 150mm Stainless steel Hinges with S.S. screws for double leaf), Brass aldrop 250mm long complete set with suitable brass screws (2 nos. complete set of brass aldrop 250mm long with brass screws for double leaf), 300mm long brass tower bolt with screws (2 nos. 300mm long brass tower bolt with screws for double leaf), 150mm long brass door handle set with brass screws (2 nos. 150mm long brass door handle set with brass screws for double leaf) complete at all lifts and all as directed by the Engineer-in-charge.Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 64 | Providing and fixing anodised aluminium Baby Latch of size 100x 10mm ISI marked (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete all as per specifications and as directed by the Engineer-in-charge. Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 65 | Providing and fixing anodised aluminium Baby Latch of size 75 x 10mm ISI marked (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete all as per specifications and as directed by the Engineer-in-charge.Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 66 | Providing and fixing in position White glazed vitreous chinaware Wall mounted European type water closet, `PARRYWARE\" make or approved equivalent comprising of i)White Glazed vitreous chinaware wall mounted European Water Closet of \"CascadeNXT\"range with P trap, ii) White Dual flush set along with dual flush fittings, cistern shell and dual flush cistern lid of \"Cascade NXT\" range, iii)White Antimicrobial solid seat cover of \"Cascade NXT\"range along with spring and bolt set, iv)Flush bend to suit with C.P.Cup. Note: i)The rate shall be inclusive of fixing of closet in wall using 16 mm dia rag bolt, 100 mm dia mouthwash bush, 32mm flush ring bush, etc complete. ii)The sample of sanitary fittings shall got approved by EIC. |
| 67 | Providing and fixing coloured vitreous china European type Water Closet with \\P\\ or \\S\\ Trap with ISI marked colour solid seat and lid of Hindware or Equivalent approved make, 10 litre low level colour PVC flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Flush bend , fixing EWC with C.P Brass screws, 15mm PVC heavy quality inlet connection of 600mm long, stop/angle cock, including testing, commissioning & cleaning etc. complete all as per drawings and specifications and as directed at site |
| 68 | Providing and fixing PVC low level / High level white colour flushing cistern 10 litres capacity (Hindware or approved equivalent make) with flush pipe with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures etc. complete as per specifications and as directed by the Engineer-in-charge. |
| 69 | Supply and fixing of Flush valve 32mm (73307A1) Spindle Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 70 | Supply and fixing Parryware 32mm Concealed Dual Flush Valve T3307A1Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 71 | Supply and fixing of Bibcock spindle for Metro\" / \" Prayag\" Waterman\"/\"Peaco\" Parryware etc Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 72 | Supply and fixing of Angle cock spindle Metro\" / \" Prayag\" Waterman\"/\"Peaco\" Parryware etc Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 73 | Providing and fixing Heavy Quality 15mm nominal bore C.P. Brass Angle cock of ‘Jaquar continental model’ or approved equivalent make for wash basin inlet / flush cistern etc. as per specifications and as directed by the Engineer-in-Charge (Samples to be got approved by the Engineer-in-Charge) |
| 74 | Supply & Installation /fixing of Ovel Shape counter type wash basin. Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 75 | Supply and fixing of CP Bottle trap 32mmfor wash basin. Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 76 | Supply & Installation / fixingFoot operated tap. Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 77 | Supply & Installation /fixingUrinal sensor(C0585DC) Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 78 | Supply & Installation /fixingUrinal connection hose Inlet /outlet. Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 79 | Supply & Installation /fixing angle cock spindle(G0253A1). Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 80 | Supplying & Installation /fixing Battary AA for sensor urinals.Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 81 | Providing and fixing 6mm thick Mirrors of size 600 x 460 x 6mm \"Modi Guard\" or approved equivalent make with bevelled edges complete with 6mm thick asbestos sheet back ground fixed to walls with C.P. brass screws and concealed washers complete all as per specifications and as directed by the Engineer-in-charge |
| 82 | Providing and fixing 5mm thick first quality mirror of required size with anodized aluminium section frame work of size 30 x 20mm, backing the mirror with 4mm thick AC plain sheet painting two coats of plastic emulsion paint over a coat of primer, fixing the entire unit on the wall surface with necessary screws etc. complete all as directed by the Engineer-in-charge |
| 83 | Providing and applying painting two coats on existing Structural steel members at a level of 8m height with Synthetic enamel paint (Asian or approved brand, colour and manufacturer) to give an even shade including preparation of the surfaces, scaffolding complete all as per specifications and as directed by the Engineer-in-Charge. |
| 84 | Providing and applying painting Two coats on existing internal and external wall surfacesupto a height of 7m with water proofing paint (Asian or approved brand, colour and manufacturer) to given an even shade including preparation of the surface, scaffolding complete all as specifications and as directed by the Engineer-in-charge. |
| 85 | Grouting at and around penetrations, construction joints and at all locations as specified in the drawingincluding necessary scaffolding, drilling holes of specified diameter, supply of grout material, PVC pipe nozzle, fixing, providing all necessary equipment like mixer and pump, manpower etc., allcomplete required to grout at specified pressure, cutting the pipes after setting of grout, sealing, finishing the surface to achieve required leak-tightness to the satisfaction ofthe EIC. Only quantity of grout injected shall be measured and paid for. This item is not intended for repair works falling under the scope of contractor for concreting works. |
| 86 | Using Cement based grouting suitable for pumping with addition of approved anti shrinkage compound @ 2% weight of cementwithwater reducing admixture as required and as directed by the EIC. |
| 87 | Using approved Polyurethane injection hydrophilic grouting comprising of two component high grade low viscosity material as per manufactures specification and as directed by the EIC |
| 88 | Providing and constructing at all floors and lifts 115mm thick brick work in cement mortar 1:4 using Fly ash bricks including providing and placing in position 2 nos of 8mm dia rods at every 4th layer, scaffolding, curing, racking out the joint on both faces etc. complete all as per specification and as directed by the Engineer-in-Charge. |
| 89 | for Basement and Ground Floor |
| 90 | Dismantling of RCC works at all levels by manually / by mechanical including Cutting and stacking of steel reinforcement bars and disposal of unserviceable materials within 50m lead, labour, tools required etc. complete in all respects as per specifications and directed by the Engineer-in-charge. |
| 91 | Dismantling brick works / Block works at all levels by manually / by mechanical including Cutting and stacking of steel reinforcement bars and disposal of unserviceable materials within 50m lead, labour, tools required etc. complete in all respects as per specifications and directed by the Engineer-in-charge. |
| 92 | Providing plastering in cement mortar 1:4, 20mm, thick at all elevations with 2% of water proofing compound or as per manufactures specification, \"lmpermo\" or approved equivalent make including hacking of concrete surfaces with pointed tool, scaffolding, finishing, curing, all as per specifications. |
| 93 | Providing and laying approved quality mirror polished Granite slabs for flooring & Skirting of required size & specified colour, pattem and free from cracks, fissures & flakes with straight edges & perfect corners laid at right angles as per pattern over a bedding of cement mortar 1:4, 20mm thick (or backing of cement mortar 1:3, 12mm thick as mentioned below) pointed neatly with white cement mixed with coloring pigment to match colour of slab and finished in all respects, including machine / hand cutting to required size and shape, moulding and polishing of exposed edges, fixingstone to level and plumb, anti-skid grooves for steps, curing, cleaning the surface neatly at the time of handing over the area, all materials and labour complete.Note: The sample Granite slab shall be got approved by the Architect/Engineer before procurement. |
| 94 | In steps/step thread, 18mm thick Granite slab with anti skid grooves of required pattering & moulding and polishing of exposed edges, fixing with 20mm thick bedding in cement mortar 1:4. The granite slab shall be single length to match step length. |
| 95 | Providing and fixing double Tubular scaffolding system using H-Frames / APS system or (cup lock type) on the exterior side upto seven story height made with 40mm dia M.S. tube 1.5m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S clamps and M.S staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runers, conection with building etc. wherever required for inspection of work at required locations with essential safely features for the workmen etc. complete as per directions and as approved by the Engineer-in-charge. The elevation area of the scaffolding shall be measured for payment purposes. The payment shall be made once irrespective of duration of scaffolding. |
| 96 | Providing and fixing Sensor tap for counter wash basin T7185A1,parryware Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 97 | Providing and fixing 20mm thick coloured marble stone slab of approved colour and shade, table rubbed, edges rounded and polished of size 750 x 500mm deep (or size as directed by the Engineer-in-charge) fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4, using 6mm nominal size aggregate and finished smooth complete all as per specification and as directed by the Engineer-in-charge |
| 98 | Providing and fixing 250mm long Anodised Aluminium aldrop. Rod thickness 16 mm. The anodic casting shall be not less than Grade AC 10 of IS 1868 : 1982 or as required by the purchaser. with necessary accessories and screws etc. in wooden doors / steel doors with necessary bolts & nuts complete as per specification and as directed by the Engineer-in-charge. |
| 99 | Providing and fixing of Sink cock G1921A1 PARRYWARE Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 100 | Providing and fixing liquid soap dispenser in CP brass container with all accessories and CP brackets including necessary screws for fixing complete all as directed by the Engineer-in-charge. |
| 101 | Providing and laying the following sizes PVC water supply line with \"Finolex / Varun / Truebore, or approved equivalent make PVC pipes suitable for 6 kg/sq.cm pressure and specials confirming & marked to IS: 4985 including jointing with PVC jointing compound, laying and fixing the pipes in the excavated trenches, cost of all types of specials such as tees, reduces, coupler, reducing bushes, threaded adaptor, elbow, tall pieces, caps etc. and testing the line as directed by the Engineer-in-charge. |
| 102 | PVC pipe 32 mm diameter |
| 103 | PVC pipe 50 mm diameter |
| 104 | PVC pipe 75 mm diameter |
| 105 | PVC pipe 110 mm diameter |
| 106 | Providing and fixing Venetian blinds vertical of Luxaflex make or VISTA LEVOLOR or approved equivalent makewith vanes of 100mm width made up of non woven polyester fabric which are suspended from the silt travelers by self aligning vanesof effective optimized system, vanes shall be coupled together by means of bead chain pivotally attach by closing to each side of each weight including the cost of blinds, fixing in Aluminium railing, other incidental charges, etc., all complete as per specification and as directed by Engineer-in-charge.Note:-1. The sample shall be got approved by the engineer before commencing the work. 2. Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 107 | Providing and fixing U-shaped rubber gasket also known as U-channel or edge trim, is a flexible sealing strip designed to fit over the edges of windows, doors, or panels and also replacement of existing damaged wheels on window frames.Note: Including cost of removing the existing material if required at site and same should be returned to Civil section of FRFCF. |
| 108 | Providing Melamine polishing on wood work (one coat) as per manufacturers instructions, Matt or Glossy finish as specified including preparation of the surfaces, complete all as per specifications and as directed by the Engineer-in-charge. |
| 109 | Removal and re fixing the aluminium partitioning along with Bason boards,glasses,clips etc including requisite materials for refixing like screws ,clips etc complete all as per specifications and as directed by the Engineer-in-Charge. |
| 110 | Removal and re fixing the existing cubicle cabins, transporting them, and then re-assembling and fixing them in a new location, including requisite materials for refixing the existing cubical components like panels,steel frames,storage units of drawers etc complete all as per specifications and as directed by the Engineer-in-Charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail