| 1 | Day to Day Maintenance of Path Lighting and Control/Feeder Panels including allied accessories as per Inventory and Terms & Conditions attached. |
| 2 | Operation of Sewage Submersible Pump Set/Water Filled Submersible Pump Set in Rainy Season as per Inventory and Terms & Conditions attached. |
| 3 | Supplying and Replacement of Street Light LED Fixture Powder Coated Pressure Die Cast Aluminum body with driver as per the requirement with Driver Efficiency>85%, Input voltage: 140-270 Volt AC, Frequency 50/60 Hz, Operating Temp range-5°C to 50°C, Internal Surge Protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency>85%, THD<10% as per IEC 61000-3-2 , PF≥0.95, IP- 66, IK-10, CRI>70, Under Voltage and Over Voltage Protection, EMI-EMC As per CISPR 15, Lenses for Beam Angle as per IESNA type I/II/III as per the width of the road and the project requirement, suitable to fit in up to 65 mm dia. pipe, life time (LED, Driver & Electrical Circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/4000°K/5700°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching)<5, Maximum Power Consumption should not more than the specified rating and Fixture shall be of relevant BIS Standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC Insulated Copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System Lumen Efficacy≥120<135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED Fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal Management: Heat Sink of Aluminum Housing such that LED Junction Temperature shall not rise above 90°C) including rebate for dismantle Fixture.45 Watt |
| 4 | Supplying Installation, Testing & Commissioning of Street Light LED Fixture Powder Coated Pressure Die Cast Aluminum body with driver as per the requirement with Driver Efficiency>85%, Input voltage: 140-270 Volt AC, Frequency 50/60 Hz, Operating Temp range-5°C to 50°C, Internal Surge Protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency>85%, THD<10% as per IEC 61000-3-2 , PF≥0.95, IP- 66, IK-10, CRI>70, Under Voltage and Over Voltage Protection, EMI-EMC As per CISPR 15, Lenses for Beam Angle as per IESNA type I/II/III as per the width of the road and the project requirement, suitable to fit in up to 65 mm dia. pipe, life time (LED, Driver & Electrical Circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/4000°K/5700°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching)<5, Maximum Power Consumption should not more than the specified rating and Fixture shall be of relevant BIS Standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC Insulated Copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System Lumen Efficacy≥120<135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED Fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal Management: Heat Sink of Aluminum Housing such that LED Junction Temperature shall not rise above 90°C).45 Watt |
| 5 | Supplying and Replacement of Flood Light, Powder Coated Pressure Die Cast Aluminum body with built in or separate driver as per the requirement with Driver Efficiency>85%, Input voltage: 140-270 Volt AC, Frequency 50/60 Hz, Operating Temp range-5°C to 50°C, Internal Surge Protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency>85%, THD<10% as per IEC 61000-3-2 , PF≥0.95, IP-66, IK-10, CRI>70, Under Voltage and Over Voltage Protection, EMI-EMC As per CISPR-15, Lenses for Beam Angle 30°-120° as per the application and the project requirement, suitable tilt able Fitting, life time (LED, Driver & Electrical Circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/4000°K/5700°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching)<5, Maximum Power Consumption should not more than the specified rating and Fixture shall be of relevant BIS Standard complete in all respect i/c connections with 1.5 sq mm FRLS/HFFR, PVC Insulated Copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System Lumen Efficacy≥120<135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED Fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal Management: Heat Sink of Aluminum Housing such that LED Junction Temperature shall not rise above 90°C) including rebate for dismantle Fixture.100 Watt |
| 6 | Supplying and Replacement of 4 mtr. high pole made out of 65 mm dia. NB, B-class GI pipe ISI marked duly welded with MS base plate of size 300 mm x 300 mm x 12 mm thick with stiffener of size 130 mm x 60 mm x 5 mm thick; top edge to be blunted with a horizontal flat>5 mm (No sharp edge), Supplying and Fixing of suitable size of Bracket for mounting the light fitting on the pole, suitable earth stud on base plate, making suitable size hole in pole at a height of 2.5 meter from base plate for cable entry/exit, painting & numbering of pole, making suitable size hole in base plate for cable entry/exit into the pole and fixing the pole on the existing foundation with the existing nuts-bolts, washers etc. complete as required including rebate for dismantle Pole. |
| 7 | Providing and laying in position, 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) reinforced cement concrete foundation of size450 mm x 450 mm x 1200 mm deep (900 mm below ground level and 300 mm above ground level) including excavation of earth, refilling, providing, cutting, bending and placing in position, reinforcement of cold twisted bars of 12mm dia.- 1200 mm long (approx.)- 8 Nos. and reinforcement ring of cold twisted bar of 8 mm dia.- 1400 mm long (approx.)- 6 Nos. (with suitable spacing) including centering & shuttering as required with providing, fixing and positioning of one set of foundation bolts comprising of 4 Nos., 16 mm dia. 750 mm long J-Type MS bolts (Threaded portion shall be galvanized) along with 3 Nos. GI nuts and 2 Nos. GI washers etc. per bolt and 1 No. anchor plate (3 mm thick) of suitable size and providing 63 mm (OD) DWC pipe ISI marked for cable entry & exit etc. complete as required. |
| 8 | Supplying and Replacement of Lycus 15-Watt LED Spike Light with Die Cast Aluminium housing for rugged outdoor usage Pendant or Surface mounting mounted with CCT-3000 K having Potted Driver, Symmetric Beam, Top Opening (TO) Driver Compartment, Toughened Glass with Environment friendly, decorative IP-66 LED Spike Light using COB LED as Light Source, IK>07 complete in all respect including connections with 1.5 sq. mm FRLS, PVC Insulated Copper conductor single core cable and earthing etc. as required including rebate for dismantle Fixture. |
| 9 | Supplying and Replacement of Adorn 6-Watt Monochromatic Buried Uplighter features with multiple optics & saturated tones of white with Die Cast Aluminium housing for rugged outdoor usage Surface mounting mounted with CCT-5700 K having Driver, Toughened Glass with Environment friendly, decorative IP-66, IK>07 complete in all respect including connections with 1.5 sq. mm FRLS, PVC Insulated Copper conductor single core cable and earthing etc. as required including rebate for dismantle Fixture. |
| 10 | Supplying of following sizes of XLPE (Cross Linked Poly Ethylene) Insulated PVC Sheathed Alumimium Conductor Armoured Power Cable of 1.1 KV grade including connection, testing etc. as required including rebate for dismantle material.2C x 16 sq. mm |
| 11 | 4C x 25 sq. mm |
| 12 | 4C x 50 sq. mm |
| 13 | Providing and Fixing 6 SWG dia. GI wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub-main wiring/cable as required. |
| 14 | Laying of one number PVC Insulated and PVC Sheathed/XLPE Power Cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required.Up to 35 sq. mm |
| 15 | Above 35 sq. mm and up to 95 sq. mm |
| 16 | Supplying and making straight through joint with Heat Shrinkable Kit including ferrules and other jointing materials for following size of PVC Insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV grade as required.2C x 16 sq. mm |
| 17 | 4C x 25 sq. mm |
| 18 | 4C x 50 sq. mm |
| 19 | Supplying and drawing of following sizes FRLS PVC Insulated Copper Conductor, Single Core Cable in the existing surface/recess steel/PVC conduit as required.3C x 1.5 sq.mm |
| 20 | 3C x 2.5 sq. mm |
| 21 | Supplying and Laying of following size DWC HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS: 14930, Part-II complete with fitting and cutting, jointing etc. direct-in-ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia. (OD-63 mm & ID-51 mm nominal) |
| 22 | Lifting Out of Sewage Submersible Pump Set/Veda Pump Set from the Existing Shallow Borewell up to the required depth along with existing accessories etc. including disconnecting of GI Pipe and disconnecting the Submersible Cable etc. complete as required. |
| 23 | Lowering and Commissioning of Submersible Pump Set in the Existing Shallow Borewell up to the required depth along with Replaced (if required)/Existing GI Pipe. Clamping (at appropriate distance), Water Proof Jointing of Submersible Cable. Replacement of required nuts, bolts, washers and packing, nipple, reducer etc. complete as required. |
| 24 | Repairing and Rewinding of following capacity Three Phase/Single Phase Sewage Submersible Pump Set/Veda Pump Set i/c cartage, dismantling, painting, reassembling and Supply & Replacement of mechanical seal, lubricant oil etc. i/c connection, testing complete as required.up to 3 HP |
| 25 | Supplying and Replacement of following Control Gear/accessories in the Existing Installation for Electric Panel Board/Feeder Pillar, Motor Starter complete in all respect including connections with appropriate size FRLS, PVC Insulated Copper conductor single core cable and earthing etc. as required including rebate for dismantle Fixture.6 A to 32 A ratings, DP MCB, “C” curve, 10 KA breaking capacity. |
| 26 | 6 A to 32 A ratings, TP MCB, “C” curve, 10 KA breaking capacity. |
| 27 | 6 A to 32 A ratings, TPN MCB, “C” curve, 10 KA breaking capacity. |
| 28 | 100 A, 30 KA, 4-Pole MCCB |
| 29 | Electronic/Analogue Timer of model FM1/Quartz Daily 110 VAC-240 VAC Base/DIN Mounting in the existing Panel. |
| 30 | 3-Pole Power Contactor of AC3 Rating 32 Amp, MNX 32 type. |
| 31 | 3-Phase DOL MK1 Starter suitable up to 7.5 HP Pump Set with Relay Range 13 to 22 Amp. |
| 32 | Thermal Overload MK1 Relay Range 13 to 22 Amp . |
| 33 | Standard Operating Coil (MK1), Coil Voltage (220-440 V). |
| 34 | Single Phase Submersible Pump Controller (MR-G2) up to 3 Hp with Relay Range 13 to 22 Amp, Start Capacitor 275 V, 50 Hz (200/250), Run Capacitor 440 V, 50 Hz MFD (2 x 50), Ammeter & Voltmeter. |
| 35 | 3-Phase Submersible Pump Controller (MU-G10) with Single Phase Preventer up to 10 Hp Pump Set, Relay Range 13 to 21 Amp. |
| 36 | Single Phasing Preventer (VSP2- Auto Reset, 40 Volts Unbalance) mounted on Panel Wall. |
| 37 | Supplying & Replacement of PVC Sheathed, PVC Insulated Copper Conductor Flat Submersible Cable of following size including connection, testing etc. complete as required including rebate for dismantle material.3C x 2.5 sq. mm |
| 38 | Providing and Fixing MV Danger Notice Plate of 200 mm x 150 mm, made of Mild Steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single Red colour on front side as required. |
| 39 | Supplying and Fixing of SS Enclosure for 3P/4P MCCB suitable to accommodate up to 3.5C x 70 sq. mm Aluminium Armoured Cable along with In-built Neutral Link for TPN System, IK08, IP-30 Protection, Space for Cable termination, Louvers for better heat dissipation, mounting holes for wall mounting i/c connection, testing etc. complete as required. |
| 40 | Supplying and replacement of Submersible Pump Set (Water Filled Motor) 10 cm (100 mm) (V4)-HC Series suitable for operation on 3-Phase, 220-415 Volts, 50 Hz AC supply of following specifications:a) Head Range: 63-15 Meterb) Discharge Range: 35-120 LPMc) Capacity: 1.5 Hp/1.1 KWd) No. of Stages: 12e) Pipe Size: 40 mmf) Capacitor Run: 50 μFg) Capacitor Start: 120/150 μFThe work shall also include Lifting and dismantling of existing Submersible Pump Set, Lowering and installation of new pump set in the existing bore well up to the required depth with existing GI pipes and Submersible Cable, Water-proof jointing of Submersible Cable,Replacement of necessary accessories (nuts, bolts, washers, packing, nipple, reducer, connections, etc.) and testing, commissioning etc. complete as required including rebate for dismantle Pump Set. |
| 41 | Supplying and Replacement of Sewage Treated Water Submersible Pump Set, duly coupled with suitable rating 3-Phase, 220-415 Volts, 50 Hz, 3000 RPM Submersible Motor, including Providing and Fixing of 6 meter long GI Chain of suitable strength for lifting the Pump Set from the UGR/Chamber/Pit etc. complete as required including rebate for dismantle Pump Set. The Pump Set shall be suitable for the following duties:a) Capacity: 3 Hp/2.2 KW (minimum)b) Discharge: 640-1000 LPMc) Head Range: 10-18 Meter or 33-59 ftd) Solid Handling Capacity: 35 mme) Outlet Pipe Size: 50 mmf) Suitable Size Cable: 10 Meter (minimum) |