| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including ,fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. all as specified and directed. |
| 2 | Taking down existing unserviceable MCB DB/TPN along with MCBs completeby disconnecting all as directed. |
| 3 | Taking down existing unserviceable sub main wiring 4/6/10 Sqmm aluminium cable all as directed. |
| 4 | Taking downold unserviceable light fittings any type and removal from site and making good disturbed surfaces of walls, ceiling etc complete all as specified and directed by Engineer-in-Charge to match with existing surface all as directed. |
| 5 | M&L for Point wiring for One light point controlled by one way 5 Amps switch with 1.5Sqmm copper conductor FRLS (multistrand) PVC insulated ISI marked unseathed cable PVC insulated ISI marked unseathed FRLS dolly concealed conduit in wall, modular MS Box, 1.6mm thick with modular cover plate with frame as required at site suitable for modular switch, socket, fan regulator, bell push, two way etc. complete all as directed by Enginer-in-charge.NOTE : (i) Modular switch socket fan regulator shall be measured and paid separately under respective items. (ii) Cost of mudular MS Box, codular cover plate an frame of any modules as required at site and as directed by engineer-in-charge is deemed to be included in the quoted rates. |
| 6 | All as per item No. 05 above but forOne fan point controlled by one way 5 Amps switch |
| 7 | All as per item No. 05 above but for One 3 pin socket outlet 5 Amps on independent board |
| 8 | All as per item No. 05 above but for one 3 pin 5 amp socket on same board all as directed. |
| 9 | All as per item No. 05 above but for One light point controlled by two way 5 Amps switches |
| 10 | All as per item No. 05 above but for One bell point controlled by one way bell push switches. |
| 11 | M&L for Point wiring for One light point controlled by one way 5 Amps switch with 2.5Sqmm copper conductor FRLS (multistrand) PVC insulated ISI marked unseathed cable in and including In stove enamelled steel conduit, modular MS Box, 1.6mm thick with modular cover plate with frame as required at site suitable for modular switch, socket, fan regulator, bell push, two way etc. complete all as directed by Enginer-in-charge.NOTE : (i) Modular switch socket fan regulator shall be measured and paid separately under respective items. (ii) Cost of mudular MS Box, codular cover plate an frame of any modules as required at site and as directed by engineer-in-charge is deemed to be included in the quoted rates. |
| 12 | M&L for Point wiring for One light point controlled by one way 5 Amps switch with 1.5Sqmm copper conductor FRLS (multistrand) PVC insulated ISI marked unseathed cable PVC insulated ISI marked unseathed FRLS dolly in existing concealed conduit in wall, modular MS Box, 1.6mm thick with modular cover plate with frame as required at site suitable for modular switch, socket, fan regulator, bell push, two way etc. complete all as directed by Enginer-in-charge.NOTE : (i) Modular switch socket fan regulator shall be measured and paid separately under respective items. (ii) Cost of mudular MS Box, codular cover plate an frame of any modules as required at site and as directed by engineer-in-charge is deemed to be included in the quoted rates. |
| 13 | All as per item No. 12 above but forOne fan point controlled by one way 5 Amps switch. |
| 14 | All as per item No. 12 above but for One 3 pin socket outlet 5 Amps on independent board. |
| 15 | All as per item No. 12 above but for one 3 pin 5 amp socket on same board all as directed. |
| 16 | All as per item No. 12 above but for One light point controlled by two way 5 Amps switches. |
| 17 | All as per item No. 12 above but for One bell point controlled by one way bell push switches. |
| 18 | M&L for point wiring using approved colour coding as per IS (For phase and neutral), with stranded copper conductor 2.5 Sqmm (nominal area), single core, multistranded, FRLS, PVC insulated and unsheathed cable 1100 volts grade, ISI 694 marked drawn in and including heavy duty PVC concealed conduit with fittings ISI marked, terminated in junction box incl 2.5 Sqmm (Nominal area) single core cable as earth continuity conductor to common earth and connected to earth dolly complete for one power point 15 Amps all as specified. |
| 19 | M&L for point wiring using approved colour coding as per IS (For phase and neutral), with stranded copper conductor 4.00 Sqmm (nominal area), single core, multistranded, FRLS, PVC insulated and unsheathed cable 1100 volts grade, ISI 694 marked drawn in and including heavy duty PVC concealed conduit with fittings ISI marked, terminated in junction box incl 4.00 Sqmm (Nominal area) single core cable as earth continuity conductor to common earth and connected to earth dolly complete for one power point 15 Amps all as specified. |
| 20 | Sub main wiring in replacement (with approved colour coding as per IS) with single core FRLS PVC insulated multistranded copper conductor cable 1.1 KV grade (main cable two runs of main cable)alongwith one run of single core FRLS PVC insulated flexible stranded copper Conductor 1.1 KV grade of earth for earthing drawn in suitable PVCconcealed conduits including Cutting chases in existing wall for laying of PVC conduits including making good disturbed surfaces with paintingof wall matching withexisiting colour after concealing the conduit in wall all as specified for size 2 run of 4 sqmm and one run of 4 Sqmm earth contuinity conductor. |
| 21 | All as per item No. 20 above but 2 run of 6 sqmm and one run of 6 Sqmm earth contuinity conductor |
| 22 | All as per item No.20 above but 2 run of 10 sqmm and one run of 10 Sqmm earth contuinity conductor |
| 23 | Supply and Fixing Ceiling rose 3 terminal 5 Amps 230 volts PVC/Polycarbonate, insulated body. |
| 24 | Supply and FixingDing Dong AC230 volts,single pole. |
| 25 | S&F ofModular snap switch SP one way 5/6 Amps suitable for 1 Module complete all as specified and directed. |
| 26 | S&F in replacement ofModular snap switch SP two way 5/6 Amps suitable for 1 Module complete all as specified and directed. |
| 27 | S&F ofModular bell push switch, SP one way 5/6 Amps suitable for 1 Module complete all as specified and directed. |
| 28 | S&F of Modular socket 3 pin 5/6 Amps suitable for 2 Module complete all as specified and directed. |
| 29 | S&F of Modular snap switch SP one way 15/16 Amps suitable for 1 Module complete all as specifiedand directed. |
| 30 | S&FofModular socket 3 pin 15/16 Amps suitable for 2 Module complete all as specifiedand directed. |
| 31 | Modular fan step regulator 120 watts for 48\"/56\" sweep ceiling fan 2 module complete all as specified. |
| 32 | S&F Switch flame proof rotary type with termination box inLM6 capacity, 16Amp, single pole 240V, 50 Hz complete all as specified. |
| 33 | Disconnection and removing the u/s casing caping conduit and S&F PVC casing caping of size 20mm including cut to shape and size to match the existing conduits suitable for LT electric supply along with necessary fixing arrangements complete all as specified and directed. |
| 34 | S&F MCB DB, SPN, 4 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed. |
| 35 | S&F MCB DB, SPN, 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed. |
| 36 | S&F MCB DB, SPN, 12 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed. |
| 37 | S&F MCB DB, TPN, 4 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed. |
| 38 | S&F MCB DB, TPN, 6 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed. |
| 39 | S&F MCB DB, TPN, 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed. |
| 40 | S&F MCB DB, TPN, 12 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed. |
| 41 | S&F MCB SP 6-30 Amps 230 volts 10 KA ISI marked. |
| 42 | All as per Item No 41 here in above but of capacity MCBDP 40 Amps |
| 43 | All as per Item No 41 here in above but of capacity MCBDP 63 Amps |
| 44 | All as per Item No 41 here in above but of capacity MCBSPN 63 Amps |
| 45 | All as per Item No 41 here in above but of capacity MCBTPN 32 Amps |
| 46 | All as per Item No 41 here in above but of capacity MCBTPN 40 Amps |
| 47 | All as per Item No 41 here in above but of capacity MCBTPN 63 Amps |
| 48 | Disconnection and removing the u/s MCB plug and socket unit and S&F Single pole and neutral Enclosure with a two pin earth plug and socket complete controlled by one single pole MCB 20 Amps 240 Volts, complete all as specified and as directed. |
| 49 | S&F in repair Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. |
| 50 | S&F in repair LED lamp 9 watts complete all as specified and directed. |
| 51 | Supply and fixing of LED (2X2) indirect light fitting circular shape 36 Watts 230 volts with internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size and colour compelte all as specified and directed. |
| 52 | Supply and fixing of LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 53 | Supply and fixing of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 54 | Supply and fixing of LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 55 | Supply and fixing of decorative Post top LED 40 Watt for 360* indirect light with IP 65 protection230 voltswith internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed. |
| 56 | Supply and fixing of Ceiling mounted Slim design LED recessed round Downlight with Superior light output and internal driver 15 Watts 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed by Engineer-in-Charge. |
| 57 | Supply and fixing of Ceiling mounted Slim design LED recessed Square Downlight with Superior light output and internal driver 12 Watts 230 voltswith internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed by Engineer-in-Charge. |
| 58 | Supply and fixing of batten LED 22 w inveter LED tube light complete fitting 230 volt energy saving, 04 hrs battery backup, CRI ≥80 ,PF > .90 more than, driver efficiency ≥ 85%,100 lumin/watt operating voltage 230 volt, 50hz operating temp (-10°C to 50°C) complete accessories internally pre wired and including connecting up with flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge. |
| 59 | Supply and fixing LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge. |
| 60 | M&L bus bar chamber size 40 cmx25cmx20cm with tin plated copper plated bus strip 4 nos and iron lead and suitable to accommodate 4 pole 63-100 Amps MCCB and provision of MS gland for cable entry with locking arrangement of cap 200 amps 415 volts 50 hz partly flushed to wall and including making good to disurbed potion and colour wash to match the existing surface .Note :MCCB shall be measured and paid separately |
| 61 | Supply and fix in repair MCCB 4 pole 100 Amps 25 KAcomplete with and including suitable size ofMS box with locking arrangementflushed in wall complete all as specified and as directed. |
| 62 | All as per Item No 61 here in above but of capacity MCCB 3 pole, 125 Amp, 36KA. |
| 63 | All as per Item No 61 here in above but of capacity MCCB3 pole 100 Amp, 25KA. |
| 64 | All as per Item No 61 here in above but of capacity MCCB 3 pole 63 Amp, 25KA. |
| 65 | Disconnection & taking down the unserviceable building light high wattage (25/30 Watts) street light fittings and Supply & fixing energy efficient Intergral type LED 25W ,IP 66,PF > 0.9,lumins 100/watt Street light luminaire comprising of epoxy powder coated hsg, enclosed with glass cover in frame mountedtesting compelte all as specified and directed. |
| 66 | Disconnection & taking down the unserviceable GI bracket of size 25/32 mm dia from the pole / building and M&L for street light bracket made out of25/32 mm dia GI tubing medium grade upto 1.5 mtr long including bending, welding ,drilling holes as required and fixing with flat iron clamps 50x6mm thick (02 Nos) with suitable nut, bolts and washers to steel tubular /concrete poles/building complete all as specified and as directed. |
| 67 | Earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected with and including galvanised iron or steel earth wire, 4mm dia (No. 8 SWG) by means bolts, nuts, check nuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SSR Part-I (2009) complete all asspecified and directed by Engineer-in-Charge.Note : The unit rate includes for protecton pipe 15mm and GI earth strip 4mm from top of earth plate upto 7.50 metre above ground level. |
| 68 | Taking down existing control board (Meter Box) and supply and fixing sheet metal board made of 1.6mm thick metal sheet and painting 2 coats with synthic enamel paint over a coat of primer including copper bus bar and fixed with wall for fixing meter complete with wiring, fitting and accessories, locking arrangements with handle (minimum size of box 65cmx75cm and adequate depth for the following equipments, internal wiring and termination of external cable, lugs and glands and conduits as required) comprising of following. (a) Incoming 100Amp 4 pole MCCB 25 KA-01 Nos. (b) Bus bar 100 Amp Aluminium(d) 10Amp DP MCB-01 No (Outgoing for stair case and garage) (c ) 40Amp DP MCB-04 Nos(for Qtr meters) (e) Fixing only arrangement for electronic type energy meters single phase 240Volt 40Amps 50HZ -04Nos. Note : Elect meter will be issued under Sch \"B\" free for fixing only. |
| 69 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed standard aluminiu conductor 2 core 6 sqmm in service connections suspen- ded by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and as directed. |
| 70 | All as per Item No 69 here in above but ofaluminium conductor 2 core 4 sqmm. |
| 71 | Supply and fix 3 module (gang box) plastic surface box with plate complete all as specified and directed. |
| 72 | Supply and fix 6 module(gang box) plastic surface box with plate complete all as specified and directed. |
| 73 | Supply and fix 8 module(gang box) plastic surface box with plate complete all as specified and directed. |
| 74 | Supply and fixModular metal flush terminal boxes with cover plate and frame suitable for 1 module complete all as specified and directed. |
| 75 | Supply and fix Modular metal flush terminal boxes with cover plate and frame suitable for 2 module. |
| 76 | Supply and fix Modular metal flush terminal boxes with cover plate and frame suitable for 3 module complete all as specified and directed. |
| 77 | Supply and fixModular metal flush terminal boxes with coverplate and frame suitable for 4-5 module complete all as specified and directed. |
| 78 | Supply and fix Modular metal flush terminal boxes with cover plate and frame suitable for 6 module complete all as specified and directed. . |
| 79 | Supply and fixModular metal flush terminal boxes with cover plate and frame suitable for 8 module complete all as specified and directed. |
| 80 | Supply and fixModular blank plate one module complete all as specified and directed. |
| 81 | Note: For the purpose of arriving at lumpsum amount, the amount of credit schedule i.e Sch \"A\" section II (i.e Rs 60,025.00 shall be deducted from the total amount arrived. |
| 82 | Total of Schedule \"A\" Rs. |